Loading...
HomeMy WebLinkAboutEngineer PlanTOP OF FOUNDATION EL. 57.0' EL. 56.0' 4" CAST IRON or EQUIVALENT MIN. PITCH 1/4" PER FOOT 4" SCHEDULE 40 PVC PIPE LEGEND 0 6 G 6 GAS LINE W W W- WATER LINE E E E E E EXIST, ELECTRIC 99 EXIST. CONTOURS — — — — — 99 PROP, CONTOURS W,%1j,/E—U,/E UNDERGROUND UTIL. COVERS TO BE WATERTIGHT AND SEPTIC SYSTEM PROFILE BROUGHT TO WITHIN 6" OF FINAL GRADE FLOW LINE 14" 4" SCHEDULE 40 PVC PIPE (not to scale) 2" of 8" to Z" DOUBLE WASHED PEASTONE OR GEOTEXTILE FILTER FABRIC (first 2' to be level) —5' 1% EL. 52.53' EL. 52.5' (H-20 D-BOX) Flaherty Environmental Services INSR PORT W/I 3" OF GRADE CLEAN SAND P.O. Box 331 EL. 56.0' Harwich, MA 02645 . 774.994.1166 [� 6" CRUSHED STONE OR MECHANICALLY COMPACTED 1000 GALLON SEPTIC TANK (EXISTING) 3" to 11" DOUBLE WASHED STONE CAUTIONI 22,0' SEE NOTE #9 — 34.0' — TH-1 DRIVEWAY 0 0 0 BENCHMARK: TOP OF FNDN EL. 58.0' 56 86,54' r 11,2' It GARAGE (SLAB) -. O EXISTING DECK 2 BR DWELLING LOT 18 18,750 SF± MAP 45 LOT 8 EXIST. LP 54 1 52 100' TO WETLAND EXIST. 1000 GST 54 50 52 VENT IF REQUIRED u U U u u U;� U U '� U 00000008c 0 000o0C 2.0' '0 --a 0 �1"1'r' ��L.� a 000000 o C- .d. e.e 00000000C 0 d e.: 00000o°oC EL 50 5' SOIL ABSORPTION SYSTEM (2) 500 GALLON H-20 CHAMBERS WITH STONE AROUND AND BETWEEN IN A 50' 13, 01 X l5, D' X 2' CONFIGURATION (SEE DIAGRAM PG. 2) BOTTOM OF TEST HOLE EL. 45.5' USGS ADJUSTMENT: N/A ROUNDWATER ELEV: N/A Yarmouth Health I)epartment APPROVED ame , Date_ DEC 222022 H E-,gt_.TH D E PT. SCALE: 1" = 30' REF.- PB 264 PG 94 REQUIRED: 5' REMOVAL OF UNSUITABLE MATERIAL LATERALLY AND BENEATH SAS TO EL. 52.5' LOCATION MAP N TH Buck f land Rd. LOCUS 3 Z G' �Z\A OF AU Fi' 9p o� EDWAFcD A. U ST No. 9 D T NAL 2- DATE: 1212012022 1 REVISED: NTS SITE AND SEWAGE PLAN FOR B & R EXCAVATION, INC,/ PAUL CARRIJOHN SMALLS 10 SOUTH HAWE'S RUN ROAD (WEST) YARMOUTH, MA GENERAL NOTES 1. ALL PRECAST COMPONENTS TO BE H-10 RATED UNLESS OTHERWISE SPECIFIED. DISTRIBUTION BOX AND ANY COMPONENTS WITH ANYANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OFA GARBAGE GRINDER. 3. MUNICIPAL WATER IS AVAILABLE. 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS. 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITY. 6. INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. 7. ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH. 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000 UNLESS SHOWN PER PLAN. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRY AND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND. 10.ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11.ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT. 12. NO KNOWN WETLANDS OR WELLS WITHIN 150 FEET OF PROPOSED LEACHING OTHER THAN SHOWN. 13, THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES. 14. LOT IS SHOWN AS ASSESSOR'S MAP 45 LOT 8 . 15. LOCUS PROPERTY IS LOCATED WITHIN AN AQUIFER PROTECTION DISTRICT (ZONE 11). 16, NO FOUNDATIONS WITHIN 20' OF PROPOSED SAS OTHER THAN SHOWN. DESIGN CALCULATIONS NUMBER OFACTUAL BEDROOMS 2 DESIGN FOR 3 GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (110 GAL/BR/DAYX 3 BR) 330 GAL./DAY REQUIRED SEPTIC TANK CAPACITY 660 GAL, SIZE OF SEPTIC TANK 1000 GAL. (EXISTING) SOIL CLASSIFICATION 1 DESIGN PERCOLATION RATE <2 MIN./INCH EFFLUENT LOADING RATE 0.74 GAL./DAY/FT2 LEACHING AREA (2) x (25.0' + 12.83 )(2) = 151 SF 25.0' x 12.83' _ 471 SF x 0.74 = 348 GPD USE (2) 500 GALLON H-20 CHAMBERS WITH STONE INA 12.83' X 25.0' CONFIGURATIONAS DIAGRAMMED RESERVE LEACHING CAPACITY N/A GPD SOIL EVALUATION TEST HOLE #1 Evaluator.- DavidD. Flaherty Jr., RS SE # 2755 BOH Witness: Jay Gardiner, RS Date: December 14, 2022 TH-1 ELEV. 56.0' 0" - 20" 20" - 23" 23" - 40" 40"-126" G.W. ELEV. N/A BOTTOM TH-I ELEV. 45.5' FILL A/E LS 10YR 312 B LS IOYR 516 C MS 2.5Y 6/4 SYSTEM DETAIL Flaherty Environmental Services 2 5' (NTS) J 12 3t3TE 0 NITAR1 "I certify that on November 12, 2002, l have passed the examination approved by the Department of Environmental Protection and that the above analysis has been performed by me consistant with the required training, expertise, and experience described in 310 CMR 15.018(2). " P. 0. Box 331 Harwich, MA 02645 774.994.1166 5' REMOVAL REQUIRED LATERALLY AND BENEATH PROPOSED SAS TO "C" LAYER ELEV. 52.5'. 5' REMOVAL SITE AND SEWAGE PLAN FOR B & B EXCAVATION, INC./ PAUL CARR/1OHN SMALLS 10 SOUTH HAWE'S RUN ROAD (WEST) YARMOUTH, MA PAGE 2 OF 2 DATE: 1212012022