Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 14.5 Lot $ Zone of Contribution: In Out Acreage /g 47_5-D Street: Commercial: Residential: � Village: Floor Plan: )/ #Bedrooms: 3 3 Owner: Installer: 13 CV/3 Address: Phone: Phone: Builder: Engineer: I:4 g-41 e r Address: Phone: / Phone: N/A YES NO 1. Required#of copies received l---- 2.Date of soils exam and percolation test not older than 2 years 1 - 3. 4-5 ft of naturally occurring pervious material,above water table r/ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands i 7. Septic tank minimum 10 ft from foundation, deck Var.: j 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: G/ 15. System not in top or subsoil (A,B horizons)or 5' removal 16.Proposed contours are suitable . 17. System meets slope requirements-min. 1/8", '''A"preferred vl f 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee `� 20. Sewage is under 10,000 gpd for parcel v 21.No garbage disposal 22. System adequately sized for its intended use k"--. 23.Minimum 6"stone or compacted below tank and dbox i ' 24. Manhole covers within 6"of grade,pump chamber cover to grade v 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed 1/ 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber -/ 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater v 34.Title V Application and permit fee,installer signature // 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd ' 37. Check area lots for groundwater/Label groundwater in Assessor's Map -� Plan reviewed by: /��?n,...,�q,y� _ 6 o:o: f--- 5 at-3