Loading...
HomeMy WebLinkAboutEngineer Plan - Revised 27 Holly Ln Septic Upgrade PETER MCENTEE <peter.mcentee@gmail.com> Thu 12/22/2022 10:14 AM To:Gardiner, Jay <JGardiner@yarmouth.ma.us>;Slack, Christine <CSlack@yarmouth.ma.us> Attention!: This email originates outside of the organization. Do not open attachments or click links unless you are sure this email is from a known sender and you know the content is safe. Call the sender to verify if unsure. Otherwise delete this email. Jay & Christine, Attached is a revised plan for the subject property. The contractor pointed out a typo on the profile section, sheet 2. The revised plan has been corrected to show the 18' field width noted in all other sections and calculations on the plan. How many hard copies would you like for your files? Peter Peter T. McEntee PE - Principal Engineering Works, Inc. 12 West Crossfield Road Forestdale, MA 02644 Tel/fax (508) 477-5313 don ne'`'.( e ,� jm x 100.98 EXISTING SPOT GRADE — — 101 — — EXISTING CONTOUR 02 PROPOSED CONTOUR N Croy 5 —W— EXISTING WATER SERVICE - BK 145-PG 5 — O.I+ W, — OVERHEAD WIRES NYV,v.;, ; p 4 x�e,• sf TEST PIT aye , s. cWmrec sf Yarmouth Health Depa men BENCHMARK D�nhW.r APPROVE � z � eda•Si LEGEND r— ! 3fiore Irfi ' c� Hrarktack 5f Name •Date Q,t�ry Poiol Pr S 02' 1 7' 30- E - _ _ __-. 27 Holly h, Mouth LHEAH Yarmouth, MA 02664 101.37 Wara0p 9Rd 1.20' 22 g WamlwomV101,D6LOCUS MAP x TP----25------{ 12' PT._.w_.. PROPOSED SEPTIC TANK f -- - _ --PROPOSED S.A.S, GENERAL NOTES: PUMP CHAMBER Iifl1,12. 18' x 25' LEACH FIELD 1500/500 CAPACITIES H-10 v--- �a0 ( ) b SHED �- W/3 DISTRIBUTION LINES 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL x EXISTING SHED 2. ALL WORK ANDD OFLTH MATERALS S ALLAND THEI CONFORM TO THE REQUIREMENTS 31' L._.__... J REMOVE & RELOCATE OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 77 _ LOCAL RULES AND REGULATIONS. except as requested below: �s x 01,67 BENCHMARK -310 CMR 15.405(1)(b)&(h): CONTENTS OF LOCAL UPGRADE APPROVAL EXISTING CESSPOOL �in 2 BULKHEAD CORNER a 1) A 5' variance, S.A.S. to bulkhead corner, for a 15' setback. TO BE REMOVED 1 BB 1 4 ~ N EL.=101.70 2) A 1' reduction to the required separation between adjusted (SEE NOTE 11) 1 x --- high groundwater and bottom of S.A.S., for 4' of separation, 1 PAT/O PATIO AL 1 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR to ti X PROPOSED SEWER CONNECTION TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE OD \ shed si BH 101.55 z INV.=100.1t(FIELD VERIFY} DESIGN ENGINEER. � N EX. SEWER00 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 1NV.=) ?.2:� o oe FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN �j % on ENGINEER BEFORE CONSTRUCTION CONTINUES. 0 10;0 �7 %EXISTING• � N 5. ALL ELEVATIONS BASED ON AN ASSUMED DATUM. m ` ,SUN HOUSE/, 27) 101,30otl 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF .� l� ' "ROOM T.O.F.=1t7012.03i X THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF + HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. I CELLAR �FL.=96.7f CHU L JR.7. WATER SUPPLY PROVIDED BY TOWN WATER SUPPLY. i 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM. x 101,34 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS X101.35 AGREED 'UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE y DIRECTED BY THE APPROVING AUTHORITIES. 100. 100,79 LOT 69 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING 1 8, 556 f S, F. CONSTRUCTION. l x 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS j t� i 101,23 IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 11 101,0'�1. - r� ��� OF M�Ss9 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE I Wtfl__ 81 00'- ��P �yG INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 1 L1 SrOl'43'40- W w IP FND o PETER T. 13. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED EXISTING MCENTEE SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. CIVIL "' 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 99.76 r No. 35109 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. PK SET i0016 100.31 100.55 100,74p�� 15. AN ELECTRICAL PERMIT SHALL BE OBTAINED PRIOR TO CONSTRUCTION. 100.00 SS/ ROLL Y LA AW PROPOSED SEPTIC SYSTEM UPGRADE PLAN 27 HOLLY LANE, SOUTH YARMOUTH, MA MACOMBER, PAULINE (LIFE EST) OWNER RECORD Prepared for: Quinn's Excavotion, P.O. Box 599, Forestdale, MA 02649 FLOOD ZONE DESIGNATION 46 SOUTH MAIN ST, APT. 213 Engineers: Surveyors: SCALE DRAWN JOB. NO. MAP NUMBER: 25001 CO5889J ATTLEBORO, MA 02703 Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 328-22 EFFECTIVE DATE: JULY 16, 2016 12 West Crossfield Rood 2854 Cranberry Hwy. ZONE AE(EL1 1) MAP ID:334-153 Forestdole, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET No. (508) 477-5313 (508) 273-0377 11/14/22 P.T.M. 1 Of 3 PROPOSED SEPTIC TANK/PUMP CHAMBER PROVIDE RISERS WITH =RAMES & COVERS OVER EACH ACCESS MANHOLE AND SET TO FINISH GRADE. MANHOLES BROUGHT TO GRADE SHALL BE SECURED TO PREVENT UNAUTHORIZED ACCESS. 7- T.O.F.=102.03t rF.G. EL.=101.7t F.G. EL.=102.3t PROVIDE ENOUGH WIRE EXISTING SLACK TO REMOVE PUMP NOTE: TO PREVENT BREAKOUT, INSTALL A 40 MIL POLY LINER AS SHOWN ON SHEET 1. TOP OF LINER, EL.=103.2 BOTT. OF LINER, EL.=100.7 PROPOSED D-BOX INSTALL WATERTIGHT RISER & PROPOSED S.A.S. COVER SET TO 6" OF GRADE INSTALL INSPECTION PORT OUTSIDE DRIVEWAY FOOTPRINT / F.G. EL.=104.0f F.G. EL.=104f OVER FIELD f /MAINTAIN 2% GRADE (MIN.) OVER S.A.S. L=8'(MAX) 18' x 25' LEACHING FIELD W/3-4" S=1% (Mw.j L =18 PR 'vlD CTHR40 PVC 4"SCH40 avc NCH 44 PERF, PVC DISTRIBUTION LINES . 3 S=Vi (MIN.) tOP EL.--IUU.1 4 4"SCH40 PVC AT ALL 8EN05 EFF.DEPTH s INV.=102.97 I NV. =102.8 TW'S ARE TO BE ` ADJ. GW EL. 4 SCH 40 PVC PROPOSED D-BOX EFFFLUENT 98.1 3 OUTLETS (MIN.) INVERT BABE Ia7RER:a STDG. GW EL. =99.75 80TT, EL.=95.17 95.6 INV.=99.8t INV. =102.73-� CONNECT TO EXISTING INV.=99.50 SEWER PIPE EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET INV.=100.1 t TEE AS MANUFACTURED BY ZABEL OR EQUAL. FILTER ESTABLISH VEGETATIVE COVER SHALL BE INSPECTED AND CLEANED ANNUALLY OR AS AS DIRECTED BY THE SANDWICH REQUIRED TO PREVENT SEWAGE BACK UP TO HOUSE. CONSERVATION COMMISSION (See Pump Detail, Sheet 3 of 3) 1500/500 GALLON SEPTIC TANK/PUMP CHAMBER PERFORATED IN S.A.S.,G�RAD ABOVE S.A.S., WITH SC SET TO WITHIN 3' OF T'CAPPED ENDS SLOPE OF PERF. PIPE = 0.51 25' EFFECTIVE LENGTH SOIL ABSORPTION SYSTEM (PROFILE) H-10 TANK •_:' NOTES: BREAKOUT ELEV.=103.1 - 1) SEPTIC TANK/PUMP CHAMBER & D-BOX SHALL BE SET LEVEL & TRUE TO GRADE ON A MECHANICALLY COMPACTED BOTTOM ELEV.=102.10 STABLE BASE OR SIX INCH CRUSHED STONE BASE AS 4' MIN. SEPARATION TO G.W. SPECIFIED IN 310 CMR 15.221(2). (WITH VARIANCE) AND 4' OF NATURALLY 2) INSTALL INLET & OUTLET TEES AS REQUIRED, OCCURRNG PERVIOUS SOILS 3) MAX. COVER OVER TANK, D-BOX & S.A.S. SHALL BE 36". EST. HIGH G.W. EL: 98.1 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PR'OR TO CONSTRUCTION. SEPTIC SYSTEM PROFILE DESIGN CRITERIA NUMBER Or BEDROOMS: 2 SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 GPD DESIGN FLOW: 330 GPD GARBAGE GRINDER: NO LEACHING' AREA REQUIRED: (330 GPD) = 445.9 SF . i'+ Lru/ �r PROPOSED SEPTIC TANK/PUMP CHAMBER: 1500/500 GAL CAPACITY PROPOSED D-BOX: 1 INLET, 3 OUTLET (MIN.), H-10 INSTALL A 18' x 25' LEACH FIELD SIDEWALL AREA: NOT APPLICABLE BOTTOM AREA: 18' x 25' = 450 S.F. TOTAL AREA: .................I...........1......450 S.F. LEACHING CAPACITY = 0.74 GPD/SF x 450 SF = 333.0 GPD EL.= 1 02.60(END) FINISH GRADE --I r-APPROVED FILTER FABRIC - L.=104. ci 16' EFFECTIVE WIDTH SOIL LOG DATE: OCTOBER 20, 2022 SOIL EVALUATOR: PETER McENTEE SE#1542 WITNESS: JAY GARDINER HEALTH AGENT ELEV. T P DEPTH 101.1 A 0" LOAMY SAND 100 4 10YR 3/1 B 8„ LOAMY SAND 10YR 5/6 PERC F1 27" 98.5 31" C MED. SAND 2.5Y 6/4 98.1 ADJ. GW ;W 48" 95.6 STG. GW 66" '9 94.1 84" PERC RATE G2 MIN/IN. "B" HORIZON STANDING GW, EL.=95.5 INDEX WELL MIW-29, WATER LEVEL=9.4 (OCT 2022) ZONE A ADJUSTMENT=2.5', ADJ. GW, EL.=98.0 3/4"-1 1/2" DOUBLE WASHED STONE PROPOSED S.A.S. 18' x 25' LEACH FIELD W/3 DISTRIBUTION LINES shr, I I BN 7. INV.; 100.2f / EXISTING ,suN HOUSE(#927) ROOM T.O.F. =102.03f' %CELLAR I FL.=96.7t �s S.A.S. LAYOUT HEALTH DEFT Index Well Readings 2019 2020 2021 )aviary FeMvnry Ma % AD R May line lJy kr ,t Sepl.Ib. 2022 WNI f0 "6 Reading Zone A Z.- B Zone C Zane D Tone F 3 W 41 Bm%table 23' AIW231 27.5 1.7 2.3 3.4 4.5 5.1 learncure 231 Barnstable 247 AIW247R 2. 27.1 3.5 52 6.9 8.7 ehlltaWe:a- 2ourna 198 BMW198 13.8 r cb8o:rcm "-'a BreWrter 21 BMW21R % 123 3.3 4.9 '2 '20 l8rcvr1tat 21 Chatham 38 CGW138R 28.8 3.1 4.7 63 7.8 S !c!,x.m '.sa Meshpee 29 MIW29 9A 2.5 5.7 4.9 6.2 S-d,lch 153 SDW253R +% 49.1 3.6 3A 7.2 Truro 89 TSwB9 11.9 1.7 2.6 3A Wetifleet:7 WNW17R 13.= L6 3A 5.1 lsrdAm 2s3 I lTa+ro 39 M-th PROPOSED SEPTIC SYSTEM UPGRADE PLAN 27 HOLLY LANE, SOUTH YARMOUTH, MA Prepared for: Quinn's Excavation, P.O. Box 599, Forestdole, MA 02649 Engineers: Engineering Yforks, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Surveyors: ,IC Engineering, Inc. 2854 Cranberry Hwy. E.Warehom, MA 02538 (508) 273-0377 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 328-22 DATE 11/14/22 CHECKED P.T.M. SHEET NO. 2 Of 3 PROVIDE WATERTIGHT RISER, FRAME & SECURED COVER SET TO GRADE HOISTING CABLE 7x19 STAINLESS STEEL 1/8" DIAMETER. % 1,760 LB. STRENGTH INV.(IN)=99.50 ALARM ON EL: 97.17 PUMP ON EL: 96.67 BOTTOM OF PUMP OFF EL: 96.17 204' PUMP CHAMBER 8 ELEV.= 95.17 PROVIDE 2— WIDE ANGLE FLOATS: 45q FLOAT NO.1: PUMP ON/OFF—SJ RHOMBUS (PROVIDED WITH PUMP) FLOAT NO.2: ALARM ACTIVATION FLOAT —PROVIDED WITH ALARM PANEL 'CN SEPARATE CIRCUIT FROV PUMP SPECIFIED) 4" KNOCKOUTS (TYP. ) 12'-2" - NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID —TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT. USE SJE RHOMBUS—JB PLUGGER OR EQUAL. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL OVICK DISCONNECT FOR EASY REMOVAL) 2"SCH. 40 DISCHARGE (THROUGH RISER —SEE PROFILE) 2" 90' ELBOW W/ 1/4" WEEP HOLE FOR SELF —DRAINING FORCE MAIN 2" SWING CHECK VALVE 2" SCH. 40 PVC DISCHARGE PIPE ADDITIONAL 3/16" VENT HOLE (MIN.) ABOVE PUMP FLANGE (TO PREVENT PREMATURE PUMP BURNOUT) LIBERTY LE40 SERIES PUMP .4 H.P. 115 V WITH 2" DISCHARGE, OR EQUAL PUMP AND ACCESSORIES AVAILABLE AT: CAPE COD WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. I ! I t I 1 I I 1 1 I I ii II \ / ! 1 1 ! I I I f I 1 A I I I i—.—LL----I—t--- PI AN X/11=U1/ PUMP DETAIL N. T. S. 20" DIA. (TY( P) --- "{) COVERS , $„ 4» 20" DIA. COVERS (TYP.) A 5'-8" f 4" OUTLET 4" INLET KNOCK 4» KNOCKOUTS 3 4'-3" SUPPORT LIQUID (SEE NOTE 3)' I COMPARTMENT,.' BEAMS LEVEL ;TYP1 ALL AVAILABLE J 5 — 4" CROSS SECTION A -A SPECIFICATIONS WT of H-10: 18.852 LBS. 1.) CONCRETE 4,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. 3.) TONGUE & GROOVE JOINT SEALED W/ BUTYL RESIN & WRAPPED 4.) REINFORCEMENT PER ASTM C1227-93. 5.) ALSO AVAILABLE IN H-20 LOADING. &) PROVIDE POLYMER WATERPROOF COATING H-10 SEPTIC TANK/PUMP CHAMBER 1500/500 WIGGIN PRECAST CORP., BOURNE MA. (800) 564-6774 4' SJR ROOM HER�� shed Shr.f BH KIT./DIN. BATH BEDROOM LIV. RM. FLOOR PLAN FOR SCHEMATIC PURPOSES ONLY BUOYANCY CALCULATIONS H-10 SEPTIC TANK/PUMP CHAMBER BOTTOM OF UNIT EL.= 95.17 HIGH GROUNDWATER EL.=98.1 BUOYANCY FORCE PER FOOT OF DEPTH: 12.2' x 6.7' x 1' x 62.4 Ibs./cu.ft. = 5100.6 lbs. MAX. DISPLACEMENT = 98.1' — 95.17' = 2.93' MAX. UPLIFT PRESSURE = 2.93' x 5100.6 Ibs/ft = 14,944.7 lbs. WEIGHT OF UNIT EMPTY = 18,852 lbs. 18,852 LBS. > 14,945 LBS. O.K. DOSING & STORAGE REQUIREMENTS DESIGN FLOW: 330 GPD DOSING REQUIRED: 4 CYCLES/DAY (RECOMMENDED) 330 _ 4 = 82.5 GALLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 82.5 GAL/CYCLE _ 125 GAL/FT = 0.66 FT/CYCLE (USE 6") STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: iNV.(IN) EL: 99.50 — PUMP ON EL: 96.67 = 2.83' STORAGE PROVIDED = 2.83' x 125 GAL/FT = 353.8 GALLONS PROPOSED SEPTIC SYSTEM UPGRADE PLAN 27 HOLLY LANE, SOUTH YARMOUTH, MA Prepared for: Quinn's Excavation, P.O. Box 599, Forestdale, MA 02649 Engineers: Engineering Works, Inc. 12 West Crossfield Road Forestdale, MA 02644 (508) 477-5313 Surveyors: JCEngineering, Inc. 2854 Cranberry Hwy. E.Warehom, MA 02538 (508) 273-0377 SCALE N.T.S. DRAWN P.T.M. JOB. NO. 328-22 DATE 11/14/22 CHECKED P.T.M. SHEET NO, 3 Of 3