Loading...
HomeMy WebLinkAboutMA6-218 - South Yarmouth - v3 - 230112THIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKOffice: (972) 771-60381629 Smirl Drive, Suite 200, Heath, Texas 75032www.gmr1.comBank of AmericaEXTERIOR LIGHTING PROGRAMDRAWING INDEX: -COVER SHEETLU-1GENERAL NOTESLU-2LUMINAIRE SCHEDULELU-3OVERALL SITE PLANLU-4FULL SITE PHOTOMETRICS PLAN AT GRADELU-5FIXTURE REMOVAL PLANLU-6DIMENSIONING PLANLU-7LANDSCAPING PLANLU-8ATM COMPLIANCE AREA PHOTOMETRICS PLAN -FOR BANK USE ONLYLU-9ELEVATIONSv3 230112MA6-2181326 Main StSouth Yarmouth, MA 02664SMVICINITY MAPSCOPE OF WORKCOUNT NOTES17 REPLACE EXISTING FIXTURE1 REMOVE POLE, BASE & FIXTURE - ADD NEW POLE, BASE & FIXTURE1 REMOVE AND PATCH7 OUT OF SCOPE2 ADD NEW POLE AND FIXTURE1 ADD NEW FIXTURE Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMAWDKRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASGENERAL NOTESLU-1 SITE ABBREVIATIONS: PL = PROPERTY LINEAFG = ABOVE FINISHED GRADE FC = FOOTCANDLECBO = CONTROLLED BY OTHERSAHD = AFTER HOUR DEPOSITORYCONTRACTOR RESPONSIBILITY NOTES:1. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING, INCLUDING COORDINATION WITH THE LOCAL JURISDICTION AND ANY ASSOCIATED PERMIT FEES OR PROCESSING. CONTRACTOR SHALL NOTIFY GMR UPON RECEIPT OF PERMIT. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING DOCUMENTS THAT ARE NOT INCLUDED IN THE LIGHTING DESIGN PACKAGE. THESE INCLUDE, BUT ARE NOT LIMITED TO, STAMPED ELECTRICAL DRAWINGS, STAMPED POLE BASE DRAWINGS, AND PROFESSIONAL SURVEYS.3. SHOULD STAMPED PHOTOMETRIC DRAWINGS BE REQUIRED, CONTRACTOR SHALL ENGAGE LOCAL ENGINEER OR LIGHTING DESIGNER AS REQUIRED TO PROVIDE STAMP ON GMR PHOTOMETRIC DESIGN DOCUMENTS.4. CONTRACTOR SHALL PROVIDE THE BANKING CENTER NOTIFICATION AT LEAST ONE WEEK IN ADVANCE OF VISITING SITES OR STARTING WORK.5. CONTRACTOR SHALL VERIFY VOLTAGE REQUIREMENTS FOR FIXTURES PRIOR TO PLACEMENT OF FIXTURE ORDERS.6. CONTRACTOR TO VERIFY LIGHTING CONTROLS PRIOR TO BEGINNING CONSTRUCTION. SEE LIGHTING CONTROL NOTES.7. CONTRACTOR SHALL RECEIVE FORMAL APPROVAL FROM GMR ON ANY FIXTURE MODIFICATIONS OR VARIATIONS FROM THE LUMINAIRE SCHEDULE. 8. CONTRACTOR SHALL VERIFY EXISTING AND PROPOSED FIXTURE MOUNTING CONDITIONS IN FIELD. ANY SPECIAL MOUNTING HARDWARE NEEDED FOR PROPOSED FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9. CONTRACTOR SHALL SUPPLY ALL NEW LIGHT POLES. NEW LIGHT POLES SHALL MATCH EXISTING CONDITIONS ON SITE FOR POLE TYPE AND PAINT COLOR.10. CONTRACTOR SHALL ORDER ALL FIXTURES FROM BORDER STATES IN ACCORDANCE WITH BANK OF AMERICA NATIONAL ACCOUNT. CONTACT NATIONAL ACCOUNT QUOTES DEPARTMENT AT BOA@BORDERSTATES.COMOR 704-372-3040.11. CONTRACTOR SHALL PERFORM ALL NECESSARY PATCHING OR REPAINTING FOR ADDED, REMOVED, OR REPLACED FIXTURES.12. CONTRACTOR SHALL REPAIR ANY DISTURBED AREAS BACK TO EXISTING CONDITION INCLUDING PAVED AREAS, LANDSCAPED AREAS, ETC. 13. CONTRACTOR SHALL VERIFY AND DOCUMENT COMPLETED WORK DURING NIGHT HOURS. ALL FIXTURES MUST BE FUNCTIONAL DURING NIGHT HOURS PRIOR TO SCHEDULING A FINAL SURVEY WITH GMR.14. CONTRACTOR SHALL PROVIDE BEFORE AND AFTER NIGHT TIME PHOTOS OF THE SITE.15. CONTRACTOR SHALL UTILIZE THE “BOA ELP INCENTIVE SITE SURVEY FORM”TO DOCUMENT THE EXACT DETAILS OF EACH FIXTURE BEING REMOVED FOR REBATE AND ENERGY SAVINGS CALCULATION PURPOSES.16. CONTRACTOR SHALL RECEIVE A PUNCHLIST FROM GMR UPON FINAL SURVEY FOR ANY REMAINING ITEMS TO BE COMPLETED.FIXTURE CLARIFICATION NOTES:1. OUT OF SCOPE-EXISTING FIXTURES TO REMAIN ON SITE WITHOUT MODIFICATION. NO ACTION REQUIRED UNLESS NOTED OTHERWISE.2. REMOVE AND PATCH-EXISTING FIXTURES TO BE FULLY REMOVED AND ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY CONTRACTOR. 3. REPLACE EXISTING FIXTURE-EXISTING FIXTURE TO BE FULLY REMOVED AND REPLACED IN THE SAME LOCATION WITH A NEW FIXTURE. CONTRACTOR TO VERIFY IF POLE AND/OR POLE BASE IS SUFFICIENT FOR THE NEW FIXTURES. ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY CONTRACTOR.4. ADD NEW FIXTURE-NEW FIXTURES TO BE ADDED.ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED TO BE ASSESSED AND PERFORMED BY CONTRACTOR. 5. ADD NEW POLE & FIXTURE-A NEW POLE AND FIXTURE TO BE ADDED. CONTRACTOR TO SPECIFY POLE TO MATCH EXISTING STYLE AND COLOR AND, IF NOT PROVIDED, POLE BASE DATA FOR NEW POLE LOCATIONS. CONTRACTOR TO VERIFY IF POLE AND POLE BASE IS SUFFICIENT FOR THE HEIGHT, LOCATION AND FIXTURE SPECIFIED.6. GMR DOES NOT SPECIFY MOUNTING HARDWARE FOR ANY SPECIFIED FIXTURES. CONTRACTOR IS TOWORK WITH DISTRIBUTOR AND/OR MANUFACTURER ON A CASE BY CASE BASIS TO IDENTIFY AND ORDER REQUIRED MOUNTING HARDWARE.7. CONTRACTOR TO VERIFY WHETHER EXISTING WIRING LOCATIONS OR THE ADDITION OF WIRING FOR NEW FIXTURE LOCATIONS IS SUFFICIENT FOR THE DESIGNATED FIXTURE LOCATION.8. CONTRACTOR TO SPECIFY POLE COLOR AND TYPE PRIOR TO ORDERING.9. ALL FIXTURES ARE ASSUMED BRONZE IN COLOR UNLESS NOTED OTHERWISE IN THE LUMINAIRE SCHEDULE. CONTRACTOR TO CONFIRM PRIOR TO ORDERING.GENERAL NOTES:1. EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED ON A LIMITED AMOUNT OF INFORMATION AVAILABLE TO THE ENGINEER. ALL SUCH CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO SUBMITTING THE BID AND ADJUSTED IF NECESSARY. NO ADDITIONAL COMPENSATION SHALL BE GRANTED AFTER AWARDING A BID FOR ANY EQUIPMENT, MATERIAL OR LABOR REQUIRED TO REWORK OR OTHERWISE MODIFY EXISTING CONDITIONS.2. THIS LIGHTING DESIGN IS BASED ON A COMBINATION OF STATE STANDARDS, THE BANK'S CURRENT SECURITY POLICY FOR EXTERIOR ATM AND AFTER-HOUR DEPOSITORIES AND BANK GUIDELINES FOR NON-SECURITY COMPLIANCE ZONES.3. TRIM ALL TREES/LANDSCAPING TO MINIMIZE IMPEDING LIGHT FROM ANY LIGHT FIXTURES THAT IMPACT THE 60' RADIUS AROUND ALL ATMS AND A RADIUS OF 50' AROUND ALL AFTER-HOUR DEPOSITORIES. CONSIDERATION MUST BE GIVEN TO TREES/LANDSCAPING IN A STATE OF FULL FOLIAGE/BLOOM AND FUTURE GROWTH. ALL LANDSCAPING WORK WILL BE PERFORMED BY OTHERS WITH A SEPARATE PERMIT (IF REQUIRED).4. ALL MOUNTING HEIGHTS ARE INTENDED TO THE BOTTOM OF THE FIXTURE.5. CONTRACTOR TO FIELD VERIFY FIXTURE PLACEMENT DIMENSIONS PRIOR TO CONSTRUCTION.6. DIMENSIONING PROVIDED IS FOR PROPOSED FIXTURE LOCATIONS ONLY, UNLESS OTHERWISE NOTED ON THE DRAWING.7. THE CONTRACTOR SHALL ATTEMPT TO ELIMINATE THE USE OF EXPOSED CONDUIT WHERE POSSIBLE. IF EXPOSED CONDUIT IS NECESSARY, THE CONTRACTOR SHALL VERIFY USE WITH PROJECT MANAGER.8. ALL EXISTING LIGHTS WILL BE REPLACED WITH LED LIGHTS AND ALL PROPOSED LIGHTS WILL ALSO BE LED, UNLESS OTHERWISE NOTED.9. ALL FIXTURES ARE TO BE MOUNTED ABOVE FINISH GRADE. UNLESS OTHERWISE NOTED, MATCH EXISTING POLE BASES.THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.CONTROLS & ADDITIONAL NOTES:LIGHTING CONTROL NOTES:THE CONTRACTOR SHALL VERIFY THE CONTROLS FOR ALL EXTERIOR LIGHTING AND ATM/AHD INTERIOR LOBBIES ON THE SITE (EXCLUDING SIGNAGE) AND ADJUST ACCORDING TO THE FOLLOWING:● IC3 CONTROL: CONTRACTOR SHALL VERIFY THAT EXTERIOR LIGHTING CIRCUITS ARE CONTROLLED BY THE CORRECT IC3 CIRCUIT. WHERE EXTERIOR LIGHTING IS INCLUDED ON CONTROL CIRCUITS FOR INTERIOR SYSTEMS, INTERIOR LIGHTING, OR EXTERIOR SIGNAGE, CONTRACTOR SHALL ADJUST EXTERIOR LIGHTING TO THE CORRECT CONTROL CIRCUIT AS REQUIRED.● PHOTOCELL CONTROL: CONTRACTOR SHALL REPLACE EXISTING PHOTOCELLS WITH NEW AND INSTALL IN A LOCATION BEST SUITED TO PROVIDE APPROPRIATE LIGHT EXPOSURE SUCH THAT EXTERIOR LIGHTS ARE ON DURING DARKNESS.● TIME CLOCK CONTROL: CONTRACTOR SHALL VERIFY LOCATION OF TIME CLOCK. IF TIME CLOCK IS IN ELECTRICAL ROOM ALONG WITH IC3 CONTROLS, CONTRACTOR SHALL ADJUST CIRCUIT TO BE CONTROLLED BY IC3 EXTERIOR LIGHTING CONTROLS. IF TIME CLOCK IS IN A REMOTE LOCATION NOT IN CLOSE PROXIMITY TO THE IC3 CONTROLS, CONTRACTOR SHALL VERIFY TIME CLOCK IS SET PROPERLY AND LEAVE CIRCUIT ON TIME CLOCK CONTROL.● MANUAL CONTROL: CONTRACTOR SHALL VERIFY THAT NO EXTERIOR LIGHTING IS CONTROLLED MANUALLY. IF ANY EXTERIOR LIGHTING IS ON A MANUALLY CONTROLLED CIRCUIT, CONTRACTOR SHALL ADJUST TO BE CONTROLLED BY PHOTOCELL OR IC3, WHICHEVER IS MOST ECONOMICALLY ACCOMPLISHED.ADDITIONAL CONTRACTOR NOTES:CONSTRUCTION COMPLETION VERIFICATIONUPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL PROVIDE VERIFICATION IN WRITING TO THE BANK OF AMERICA PJM THAT ALL WORK IS COMPLETE ACCORDING TO THE CONSTRUCTION DOCUMENTS, AND THAT ALL EXTERIOR LIGHTING IS FUNCTIONING DURING NIGHTTIME HOURS. COMPLETION PHOTOS, TAKEN AT NIGHT, SHALL BE PROVIDED IN THE FOLLOWING FORMAT:PROVIDE A SINGLE DOCUMENT CONTAINING THE FOLLOWING:● SITE PHOTOS FROM ALL SIDES OF BUILDING● MINIMUM OF 3 PHOTOS OF EACH COMPLIANCE AREA (ATM(S), AFTER-HOUR DEPOSITORIES, ASSOCIATE ENTRY) FROM DIFFERENT ANGLES● MINIMUM OF 2 PHOTOS OF ALL NON-COMPLIANCE AREAS FROM DIFFERENT ANGLES Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMAWDKRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASTHIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.LUMINAIRE SCHEDULELUMINAIRE SCHEDULESYMBOLTOTALFIXTURECOUNTTYPENEW POLECOUNTMANUFACTURER MODEL MODEL NUMBER NOTES MOUNTING HEIGHT MOUNTING ACCESSORYBUGRATINGMOUNTINGTOTALWATTAGE5 BA1 - CREE CPY CPY250-C-2L-40K7-F-UL-DM-WH REPLACE EXISTING FIXTUREMATCH EXISTINGCANOPY HEIGHT- B1-U0-G0 SURFACE CANOPY MOUNT 70 W1 BA2 - CREE CPY CPY250-C-2L-40K7-F-UL-DM-WH ADD NEW FIXTUREMATCH EXISTINGCANOPY HEIGHT- B1-U0-G0 SURFACE CANOPY MOUNT 14 W4 DC1 - CREE CDR CDR-8-ALS(2500L)-9ACK(40K)-10V5-WH-UNV REPLACE EXISTING FIXTUREMATCH EXISTINGCANOPY HEIGHT- B1-U2-G0 RECESSED CANOPY MOUNT 116 W4 EK1 - CREE ZR22 ZR-22-40L-840-10V5-UNV REPLACE EXISTING FIXTUREMATCH EXISTINGCANOPY HEIGHT- B2-U0-G1 RECESSED CANOPY MOUNT 128 W1 GY1 1 CREE OSQ OSQ-L-B-22L-40K7-5N-UL-NM-BZ REMOVE POLE, BASE & FIXTURE - ADD NEW POLE, BASE & FIXTURE 20' AFG OSQ-ML-B-DA-BZ B5-U0-G3 POLE MOUNT 132 W2 GY2 2 CREE OSQ OSQ-L-B-22L-40K7-5N-UL-NM-BZ ADD NEW POLE AND FIXTURE 20' AFG OSQ-ML-B-DA-BZ B5-U0-G3 POLE MOUNT264 W4 SG1 - CREE SECURITY EDGE SEC-EDG-3M-WM-04-E-UL-BZ-350-40K REPLACE EXISTING FIXTURE MATCH EXISTING - B1-U0-G1 WALL MOUNT 184 W1 WB1 - - - - REMOVE AND PATCH - - - FLOOD 0 W3 YH1 - - - - OUT OF SCOPE - - - FLOOD 0 W4 YK1 - - - - OUT OF SCOPE - - - WALL MOUNT 0 WGRAND TOTAL WATTAGE 908 WLU-2**SEE FIXTURE CLARIFICATION NOTE #9****CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** ATM1LOBBY ENTRYAHDATM2EK1DC1BA1BA1BA2YK1YK1YK1YK1BA1SG1BA1BA1SG1SG1SG1GY2GY2GY1YH1WB1YH1YH1OVERALL SITE PLAN--EXISTING POLES -DECORATIVE -STEELEXISTING POLE BASES -DECORATIVEEXISTING DRIVE THRU CEILING - HARD, DROP INSITE NOTES:EXISTING CONDITIONS:1.2.3.Massachusetts Route 28LU-3TOTALFIXTURECOUNTTYPE NOTESMOUNTINGHEIGHT5 BA1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 BA2 ADD NEW FIXTURE MATCH EXISTINGCANOPY HEIGHT4 DC1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT4 EK1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 GY1 REMOVE POLE, BASE & FIXTURE -ADD NEW POLE, BASE & FIXTURE20' AFG2 GY2 ADD NEW POLE AND FIXTURE 20' AFG4 SG1 REPLACE EXISTING FIXTURE MATCH EXISTING1 WB1 REMOVE AND PATCH -3 YH1 OUT OF SCOPE -4 YK1 OUT OF SCOPE -Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCAS1/16" = 1'-0"1OVERALL SITE PLAN 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.10.10.10.10.10.20.30.30.20.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.10.20.20.20.10.20.30.50.91.00.60.30.20.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.10.30.50.60.40.20.40.81.75.25.82.30.50.20.10.10.10.00.00.00.00.00.00.00.00.00.00.00.00.00.10.00.20.41.41.80.20.51.33.05.529.02.00.80.30.20.10.10.10.00.00.00.00.00.00.00.00.00.00.00.10.00.00.30.63.24.00.20.51.64.56.318.923.56.11.50.40.20.20.10.10.10.00.00.00.00.00.00.00.00.10.00.10.00.00.40.94.14.63.80.40.30.20.20.10.10.10.00.00.00.00.00.00.00.00.00.10.10.20.61.63.23.71.40.20.50.40.30.20.10.10.10.00.00.00.00.00.00.10.10.10.20.51.53.64.85.60.10.80.60.40.30.20.10.10.00.00.00.00.00.00.10.10.20.30.51.57.615.013.70.01.51.20.80.40.30.10.10.10.00.00.00.00.10.10.10.30.51.02.25.43.90.01.51.71.30.70.40.20.10.10.00.00.00.00.10.10.20.30.71.42.33.43.92.62.41.01.50.90.50.30.10.10.00.00.00.00.10.10.20.40.81.72.13.13.02.74.32.010.119.836.73.63.12.92.00.00.00.50.30.20.10.00.00.00.00.10.10.20.50.91.72.13.53.56.76.18.36.86.06.38.15.95.04.64.03.22.11.41.10.60.30.20.10.00.00.00.00.10.10.20.50.91.82.33.84.46.19.28.16.85.85.35.34.74.53.83.42.60.81.60.80.50.30.20.10.00.00.00.00.10.10.20.40.71.52.63.24.14.85.35.64.93.83.64.24.43.43.12.92.52.21.40.80.40.20.10.10.00.00.00.00.00.10.10.20.50.91.72.22.12.32.93.22.82.42.82.62.62.72.42.22.11.51.00.50.30.20.10.10.00.00.00.00.00.10.10.20.30.50.91.31.51.71.51.51.31.21.11.11.11.10.21.21.10.80.50.40.20.10.00.00.00.00.00.00.00.10.10.10.20.30.50.60.70.80.80.80.80.70.70.60.60.60.60.60.50.00.00.10.10.00.00.00.00.00.00.00.00.00.10.10.10.20.30.40.40.50.50.40.40.40.40.40.40.40.40.30.30.20.10.10.10.00.00.0ATM1LOBBY ENTRYAHDATM2EK1DC1BA1BA1BA2YK1YK1YK1YK1BA1SG1BA1BA1SG1SG1SG1GY2GY2GY1YH1YH1YH1 FULL SITE PHOTOMETRICS PLANCALCULATION SUMMARY FULL SITECalculation Points Name Average Maximum Minimum Ave/MinMax/MinFULL SITE @ GRADE 1.1 fc 36.7 fc 0.0 fc 0.0 0.0LU-4NOTES:1.THE SCOPE OF WORK FOR THIS PROJECT IS LIMITED TO EXTERIOR LIGHTING RENOVATIONS AS SHOWN ON THE PLANS. 2.ALL PROPOSED LIGHTS WILL BE FULL CUTOFF LED LIGHT FIXTURES.3.ALL EXISTING LIGHTS WILL BE REPLACED WITH FULL CUT OFF LED LIGHT FIXTURES.4.REFERENCE THE LUMINAIRE SCHEDULE (SHEET LU-2) FOR ADDITIONAL LIGHT FIXTURE INFORMATION.Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASMassachusetts Route 281/16" = 1'-0"1FULL SITE PHOTOMETRICS PLAN ATM1LOBBY ENTRYAHDATM2WB1FIXTURE REMOVAL PLANLU-5TOTALFIXTURECOUNTTYPE NOTESMOUNTINGHEIGHT5 BA1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 BA2 ADD NEW FIXTURE MATCH EXISTINGCANOPY HEIGHT4 DC1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT4 EK1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 GY1 REMOVE POLE, BASE & FIXTURE -ADD NEW POLE, BASE & FIXTURE20' AFG2 GY2 ADD NEW POLE AND FIXTURE 20' AFG4 SG1 REPLACE EXISTING FIXTURE MATCH EXISTING1 WB1 REMOVE AND PATCH -3 YH1 OUT OF SCOPE -4 YK1 OUT OF SCOPE -Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASMassachusetts Route 281/16" = 1'-0"1FIXTURE REMOVAL PLAN ATM1LOBBY ENTRYAHDATM27'-1"1'-8"2'-10"2'-1"EK1DC1BA1BA1BA2YK1YK1YK1YK1BA1SG1BA1BA1SG1SG1SG1GY2GY2GY1YH1YH1YH11'-5"1'-4"DIMENSIONING PLANLU-6TOTALFIXTURECOUNTTYPE NOTESMOUNTINGHEIGHT5 BA1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 BA2 ADD NEW FIXTURE MATCH EXISTINGCANOPY HEIGHT4 DC1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT4 EK1 REPLACE EXISTING FIXTURE MATCH EXISTINGCANOPY HEIGHT1 GY1 REMOVE POLE, BASE & FIXTURE -ADD NEW POLE, BASE & FIXTURE20' AFG2 GY2 ADD NEW POLE AND FIXTURE 20' AFG4 SG1 REPLACE EXISTING FIXTURE MATCH EXISTING1 WB1 REMOVE AND PATCH -3 YH1 OUT OF SCOPE -4 YK1 OUT OF SCOPE -Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASMassachusetts Route 281/16" = 1'-0"1DIMENSIONING PLAN ATM1LOBBY ENTRYAHDATM2LS1LS1LS1LS1LS1EK1DC1BA1BA1BA2YK1YK1YK1YK1BA1SG1BA1BA1SG1SG1SG1GY2GY2GY1YH1YH1YH1LANDSCAPING PLANLANDSCAPE SCHEDULESYMBOL QTY NOTELS1 5 TRIM LANDSCAPING DOWN TO 36"LU-7Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASGC TO VERIFY WITH LOCAL AUTHORITY HAVING JURISDICTION ON TREE TRIMMING AND/OR REMOVAL PRIOR TO COMMENCING WORKMassachusetts Route 281/16" = 1'-0"1LANDSCAPING PLAN 0.10.10.10.10.20.20.10.10.10.20.20.30.30.30.10.10.10.20.30.40.60.70.80.60.60.10.10.10.20.30.40.71.21.62.01.71.30.80.40.20.20.30.40.50.81.32.85.36.75.73.11.30.60.30.20.20.40.50.81.11.31.94.814.623.119.85.71.00.50.50.30.20.20.30.61.11.82.84.15.05.731.442.736.60.22.11.00.50.30.20.10.10.20.40.71.52.85.18.310.113.930.642.634.314.03.61.40.60.30.20.10.10.20.30.71.63.26.78.19.413.922.229.322.410.13.71.70.80.40.20.20.15.64.85.16.312.631.233.423.018.54.42.23.43.75.54.86.17.79.24.822.114.016.84.54.94.43.57.26.87.57.67.17.610.69.47.25.35.64.75.36.55.53.511.511.510.69.98.77.15.95.86.06.46.76.35.65.45.75.24.95.44.813.010.89.08.37.36.66.36.15.85.75.75.75.25.25.24.73.73.99.68.87.97.16.25.85.55.25.05.05.55.74.94.74.85.04.86.86.85.64.94.34.14.14.24.74.94.94.64.13.93.93.75.24.74.23.83.63.73.83.73.53.43.83.83.43.13.33.13.13.02.92.72.72.3COMPLIANCE AREA50' RADIUSATM1LOBBY ENTRYAHDATM2COMPLIANCE AREA50' RADIUSEK1DC1BA1BA1BA2YK1YK1YK1YK1BA1SG1BA1BA1SG1SG1SG1GY2GY2GY1YH1YH1YH1 ATM COMPLIANCE AREA PHOTOMETRICS PLANNOTES:1. READINGS ARE MEASURED AT 36" (3') ABOVE GRADE.2. THE SCOPE OF WORK FOR THIS PROJECT IS LIMITED TO EXTERIOR LIGHTING RENOVATIONS AS SHOWN ON THE PLANS.3. REFERENCE THE LUMINAIRE SCHEDULE FOR ADDITIONAL LIGHT FIXTURE INFORMATION.4. GC TO VERIFY WITH LOCAL AUTHORITY HAVING JURISDICTION ON TREE TRIMMING AND/OR REMOVAL PRIOR TO COMMENCING WORK.LU-8CALCULATION SUMMARY COMPLIANCECalculation Points Name Average Maximum Minimum Ave/MinMax/MinAHD & LOBBY ENTRY 50' @ 36" 6.5 fc 33.4 fc 2.2 fc 3.0 15.2ATM2 50' @ 36" 4.3 fc 42.7 fc 0.1 fc 0.0 0.0Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMBLUE = NEW FIXTUREGREEN = EXISTING FIXTURE LOCATION TO BE REPLACEDORANGE = EXISTING FIXTURE TO REMAINTURQUOISE = FIXTURE TO BE REMOVEDPINK = REPLACE WITH NEW POLE AT NEW HEIGHT= PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATIONAWD= INDICATES NEW SECURITY FENCE__-_-THIS LIGHTING PLAN ILLUSTRATES ILLUMINATE LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICAN (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINAIRES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS.KRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASMassachusetts Route 281/16" = 1'-0"1ATM COMPLIANCE AREA PHOTOMETRICS PLAN Bank of AmericaSMTHIS PLAN SET IS PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE BANK AND THE USE OF THIS DESIGN IS PROHIBITED WITHOUT THE EXPRESS PERMISSION OF THE BANKSHEET NO.REVIEWED BY:DESIGNED BY:DRAWN BY:APPROVED BY:123REVISIONNO.DESCRIPTIONREVISED BYKRMAWDKRMSouth Yarmouth1326 Main StSouth Yarmouth, MA 02664MA6-218v3 230112CASCASELEVATIONSLU-93/32" = 1'-0"1ELEVATION 13/32" = 1'-0"2ELEVATION 23/32" = 1'-0"3ELEVATION 33/32" = 1'-0"4ELEVATION 4