Loading...
23-A008 12 Dundee DriveRECERVED ° T� TOWN OF YARMOUTH ,x 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 JA N 17 Telephone (508) 398-2231 Ext. 1292-Fax (508) 398-0836 Eb K NG'S HIGHWAY HISTORIC DISTRICT COMMITTEE _ YARMo u ; �. APPLICATION FOR CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMIT 4 copies OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Catenories That Apply: Indicate type of Building: Commercial Residential 1) Exterior Building Construction: New Building Shed —Af-golar Panels Other: Addition Alterations Reroof Garage 2) Exterior Painting: Siding Shutters Doors _"rim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work: %� C.Jtiil� PI''; _ Map/Lot # `t 3,�s Owner(s): C P Phone M-281 ISY 0 C711 All applications o Y1� must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: '112 ,4Pke y"t- V10y%!2�- 00 C�t G�,�� S Year built: / � y Email: ot�ye �. ,S itcd : rcl } ClioriAg-I.&Iek Preferred notification method: Phone Email Agent/contractor: }�'.� irYs���, L Phone #: 9 Mailing Address: ' c X %f o cag631 Email:-Z16/&, e S tj1 ,,4d4j- �_� 6o Preferred notification method: Phone mail '©ascription of Proposed -Work: ` S.G ���. ������� �r} ���� S�vA% -t(fGr.-t Avfl� 4 f'l-e-. y':1"1� Q.�d � �) ��lai` �6r/�ULS a,.l 1i.� P�t-!fi �� r•� R'e'OL�_ � axe f U Signed (Owner or agen _ / i1 �-z ➢ Owner/contractor/agent is aware that a permit is required from the Building Department. (Check other departments, also.) ➢ If application is approved, approval is subject to a 10-day appeal period required by the Act. ➢ This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. ➢ All new construction will be subject to inspection by OKH. OKH-approved plans MUST be available on -site for framing 8 final inspections. For Committee use oniv: Rcvd Date: 17 -3 Amount' CashICK #:. &q Rcvd by: L3 5 45 Days: Date Signed: Approved Reason for Denial; Signed: Approved with Modifications Denied APPLICATION #: 23 - &Ck GENERAL SPECIFICATION SHEET Project Address: FOUNDATION: Material: Exposure (Not to exceed 18"): CHIMNEY: Material/Color: GUTTERS: Material/Color: ROOF: Material: Pitch (7/12 min) Height to Ridge: Color: SIDING: Material/Style: Front: Sides/Rear: Color: Front: Sides/Rear: TRIM: All windows & doors to be trimmed with: 1x 4 1x6 (Circle one.) Material: Color: DOORS., Qty: Material: Color: Style/Size (if not listed/shown on elevations): STORM DOORS: Qty: Material: Color: GARAGE DOORS: Qty: MatT Style: Color: WINDOWS: !side:: Front: Left: Right: Rear: Color: Manufacturer/Series: Material: Grilles (Required): Pattern (6/6, 2/1, etc.) Grille Tvae: True Divided Lite: Snap -In: Between Glass: Permanently Applied: Exterior Interior STORM WINDOWS: Qty: Material: Color: SHUTTERS: MatT Style. Paneled Louvered Color: SKYLIGHTS: Qty: Fixed Vented Size Color: DECK: Size: Decking Mat'l: Color: Railing MatT Style: Color: WALLS/FENCES* (Max 6' height): Height: Mat'I: Style: Color: COLOR CHIPS RECEI Y EV JA N 1 7 2023 YAH1vtUU7 r; (Show running footage & location on plot plan.) *Finished side of fence must face out from fenced in area. UTILITY METERS/HVAC UNITS. Location: Screening: LIGHTS: Qty: I Style: Color: Lo ation(s): L-111iT Pl:?f S:-Qty. Material: Color: Location(s): Additional information: 4 6� —. �7 S' `� A.Iz Cl� �' $ c'/t l" r%ac+�[ �J" _ 2-General , f�" _ ,� APPLICATION #: 4 _ ram., ' e Y SIGN SPECIFICATION SHEET Project Address; _ Year Built: Check one: New Sign Addition/Alteration to Existing Sign COLOR CHIPS Freestanding Affixed to Building For Affixed Slans: Style of mounting fixture: Color: Size of sign: Material: Lettering: Style Color(s): RECcIVEn Please note sign placement on elevation(s) and attach full -color mockup(s) of proposed i� LA sign(s) including artwork and colors. JAN Y 7 2023 YAh-MOU f-f i OLD KfNG'S HIGHWAY For Freestanding Suns: Style of signboard: Material: Size: Color(s): Lettering: Style Color(s): Posts: Material Color(s): Height to crossbar (not to exceed 6'): Single -faced: Double-faced: Please note sign placement on plot plan and attach full -color mockup(s) of proposed sign(s) including artwork and colors. For All Signs: Lighted: Yes No Type/placement of lighting: Screening of Lights: Additional information: b 14 %1r,�&Lz •f �e �/'P� t S'ii1C_ `� 'f"tJ A?")V,M/z-. r4o Vj'.S' /. d 2-Sign APPLICATION M g_�_ _Aw Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 45-DAY TIMEFRAME WAIVER Application #: Project Address: �-e 0- a �e Application Received Date: vd 3 45 Day Decision Deadline: RECEI VED JA N 17 2023 �tvjuu-1 r-, I/We, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: Date: Signed: �- ��r �►� Owner Owner Contract /Agent TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 2023 MEETING SCHEDULE g3 --fU(k TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE W CEFIV E) ABUTTERS' LIST JAN Z 7 2023 rAhwivU'i t, Applicant's (Owner) Name: �-xzaA z Property Address/Location.- Hearing Dates Notices must be sent to the Applicant and abutters (including owners of land on any public or private street or way) who's property directly abuts or is across the street from the Applicant Please provide the Assessor's Tax Man and Lot numbers only. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list Note. Instructions for obtaining the abutters Map and Lot numbers car, be found on the Old King's Highway Department page on the Town website www..yarmouth.ma.us Applicant Information, Abutter Information- Map Number Lot Number 4 L3 43 I L6 3 ✓� 5-41 �3 "3� l&a-3-q i i 82018 Application #: ` j -?� 1/17/23, 2:42 PM abouttlank 12 Dundee Drive W- i43.68 14, 3.71 143,86.5 14390 143.65 *43.89 143. 143.67 _ _ 143.86.4 143,86.6 LIVERPO(X DRIVE 1Y3.� O� 143:72 143.87 G� lGF 143.86.7 — --- 143.52 D P$ > 143.86.3 Q*14 143.5 1 143.86.2 A143.51 1 4 � 1`3.85 / 143'S3 143. 4",._ _ 143t,. 58 2��c, . 143 „143.86.1 14333 143 34 1 4�1W 143.54 143 4 041 'C}�4�77 � 32 143.35 140 57 3 �0� 1', 14 7,8 f43.'40 143.31 14 36 i P .39 �143.42 143.� 1 �� 143.56 143.55 8`a 143143.39 F 143.83 January 17.2023 RECEIVED JAIL 17 2023 Y Hh MVU i n #::'ti7 6 300 R -.X—s r GA +fame t[1ri Ciii a+]ins'!s'G'er.�,nL i�'Y. Ti p'0+W44Y.^QT.VS]YWiRpP.'NiMi �rfxo-, Ea+aomcwy; about:blank SUNWINDLLC + o< Rgsi„ ential Solar Roof Mount System Proposal To: Susan Porter 12 Dundee Drive Yarmouthport, MA 02675 November 30. 2022 300 Cranbem Highway Orleans, MA 02653 PO Box 700 Brewster, MA 02631 888-997-8694 ww•w sunwindllc.com GCGIVED JAN 1 7 2023 rHhIvIUU I h ll KFl�in 111— We propose to install a solar photovoltaic (PV) system at the above listed address to reduce annual electrical costs by generating onsite electricity. Sunwind recommends installing the system detailed below to optimize solar energy production: Scope of Work • Install a 10.5 kW (10,500 Watt) photovoltaic system using (28) LG 375 Watt or equal solar panels. • Install Enphase iQ7A microinverters to convert solar panel DC power into AC. • The system shall be installed on black Snap N' Rack aluminum racking. • Install components for data monitoring via the existing internet connection. • SMART meter socket and AC disconnect to be located on the exterior per utility company requirement. • InstalI solar ►varning placards per code. Installed Cost We propose to install the solar photovoltaic system as outlined above far .................. goo Price is valid for thirty days from the date of this proposal. Cost -Based htsentiyes_(First Year) Federal Investment Tax Credit (30% of the installed cost) .......................................... saw MA Residential Renewable Energy Income Tax Credit ........................................... S 1.00(7 Total value of incentives............................................................................................ 1� Balanceafter incentives............................................................................................. Prod- uction-Based Incentives Net Metering: Massachusetts laws allow for all solar enerw- facilities to be interconnected to the electrical service provider, The excess energy produced bN. a net -metered facility is exported to the electrical grid and system owners are credited for all energy exported at a value roughly equal to the prevailing price per kWh. SMART Program: The state of Massachusetts SMART (Solar Massachusetts Renewable Target) program is designed to help customers reduce their electrical energy costs with an added incentive. The SMART program pays you monthly via check for the power generated by your solar system at a set rate per kWh produced, for a term of 10 years. [`9:CEIVFV,} JAN 17 2023 G 1 � fARIViUU i r, ; i�r J KING'S HIGHiNA' System DC Size: 10.5 kW Annual Energy Offset: 95% System AC Size: 9.77 kW Annual Electric Consumption: 13,000 kWh Est. Financial Gain Year 25: $96,344 Annual System Production: 12,285 kWh Annual Revenue/Savings (First Year): Net Metering Value: SMART Revenue: 12.285 kWh x $0.26/kWh = 12,285 kWh x $0.035/kWh (current SMART rate) = $3,194 S430 Total annual value of energy: Annual Net Metering + SMART Revenue = $3,624 Return on Investment: Balance after first year sayings and revenue: Balance after cost -based Annual savings Balance after incentives - & revenue = first year jow - $3,624 = Balace after cost -based Annual savings Simple R01 incentives — and rei-entie = - $3,624 — 6.1 Years System Payback Graph $100.000 $ 75.000 CD U S50,000 m m tr v $25.000 $0 -S25,000 5 10 15 20 25 Year This graph represents the data contained in the table on the following page. g3 �-/Vz System Luout Proposed Solar Panel Layout 20 solar panels on the garage roof R panels on the rear of the main house Total of 1-8 solar panels on roof RECEIVED JAN 17 2023 1, ]�. F{ R� � p� i• X F � � ,S a4lh. �r(�i m f a I Q LG375N 1 K-A6 375W The LG NeON® 2 is LG's best selling solar module and one of the most powerful and versatile modules on the market today. The ce are designed to appear O-black at a distance, and the performan warranty guarantees 90.6°% of labeled power output at 25 years. AffAfade in USA Features Enhanced Performance Warranty ` LG Ni 2 Black has an enhanced performance warranty. After 25 years, LG Nsi 2 Black is guaranteed at least 90.6% of initial performance. Solid Performance on Hot pays LG Ni 2 Black performs well on hot days due to its low temperature coefficient. RFC- ` 1� U JAN 17 2023 l 25-Year Limited Product Warranty zs,:= The NeON° 2 Black is covered by a 25-year limited product warranty. In addition, up to $450 of tabor costs will be covered in the rare case that a module needs to be repaired or replaced. + Roof Aesthetics LG NeONO 2 Black has been designed with aesthetics in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA, Inc. LG Electrnnics is a gk hal Wade, in electronic products in the ciean energy markets by atEanng solar pV panels and energy storage systems. The company first embarkedon a solar nergy sacra rarch eseprogram in 1995, supported by LG Group' .—,, -pern— .,the semi-conducmr, LCO, chemistry and matanals industries. In 2010. LG w Sot cressfupy ased it reles first MomXe series to the ma i which is new avati an 32 countries. The Nii (previous Mooa7P NeON), Ne0Na2. Ni ailra—I won the "Intersolar AWARD' m 2013. 7015 and 2016, which demonstrates LG's leadenshipand innovation in the solar industry ® LG Lifes Good LG375N1K-Ai 1 6117/21 10:56 AM LG NeON'2 Black LG375N1K-A6 Genera[ L]ata Ceti Propertles{MateriaUType) I MonpuystalhreJN-type Ceti Maker i LG Ceti Configuration Number of Busbars 12FA Moci Dimenstans(L x Wx Hi I 1740mn xl047mmx 40 min Weight .. __._..... .. .. 18.6 kg ........_- _. . .. Glass (Material) 1 Tempered Glass with AR mating -_-_ 81 (Color) ....._-.-_._..-_..._-.. _....... - Black ... .. Frame (Material) Anodimd Alum Junction Box (Protectian Degree) 3 IP 68 with 3 Bypass Diodes Cables (length) 1,100ni 2EA Conrlectar (TypelMaker) MC 4AAC Certifications and IEC61215-1l-1-1/2:2016,IEC61730-1/2:2016, UL 61730-t . 2017, Ui 2017 150 9001, ISO 14001, 150 50001 ' OHSAS IB001 S41ttMist CarrosinnTest IEC 61701 2012 Seventy 6 Ann rronm Corrosion Test lK 62716.2013 Module Fire Performance: Type 2(UL61730) Fire Rating ! class C(UL 790, ULUOM C. 1703) Solar Module Product Warranty 25 Year IJmibed Solar Module output Warranty linear Warranty` •fmpraved 1=gar 9859E from 2-24thyear-033%lyeardawR 906%atyar25 Temperature Characteristics NMOTa ['C] 4233 Prni [VIC] fi35 Voc , NMI -0,26 Ise --- -[VIC] 0.03 -NMOT (N.,mal Moc4rle Operatingf—peramrey Irradianm 800 Wtri Ambient temperature 20°C, Wind speed 1 m1% Specu uan AM 1.5 Electrical.--___perties (NMOTZ _` Model Maximum Power(Pmax) MPP voltage(Viri IV] MPP Cunent(Inni (A] Open Circuit Voltage Short circuitctri(hc) - (A) IN Ctwves 1,4375141 K-A6 201 ....... � ......... .......--.... 8.33 395 8.84 0,0 0.0 5.0 t0.0 15.0 20,0 25.0 3Q0 350 40.0 4S6 WMMrm (9 LG Life's Good JAN 1 1 '3 Electrical Properties (STC•) U9 �r� `7 Model _. .....,... 1.13375NIWA6 Mmdmum Power(Prnax) [WJ 375 MPP Voltage (Viri ! [V) 359 MPP Ctrrent(iri [A] : 10A5 --. ..-- 0 C.kcWt Voltage ___. - - _ .._. 42,0 .-.-.-.- __.- .. Short Grcult current(Isc t5%) [R] _- - 11.00 ..... .. _. Ma" Efficiency --- i [%] .....__._ 20.07 Pomrlllbk Ke - [96) - 0- 3 'STC (stardardTest Condition) Irrediantt 1000 wpm ;cell teiaperature 2s'C. AM 1.5 Measurement Tot..— of Pmax: r 3% Operating Conditions operating Temperaun rC] -40--+85 Maximum Systemvattage [Y] 1000(UL71EC) Maxknum Serfes Fuse Rating [A) 20 Loi _ 5,400 Mecharrrai Test Load•(Aear)) i_ psf [Palpsf] 4,000 •Rued anIEC 61215-2 2016 (Test Enact - Design Load x Safety Factor (1,5)) Mechamical7 t loads 6,000Pa15,400Pa dosed on IEC 612152005 Packaging Configuration Nunber of Modules per Pallet [FA] 25 Number of Modules per 40' Container (EA] 650 Ntrnber of Modules per 53' Container (EA] 050 Packaging Box Dimen6ws(Lx WxH) __. fmm] 1,790x1,120x1,213 ......._..-._..-..... .......... _ Packaging Box Oimersaws(L x W x H) [in} 70.5 x 44.1 x 47,8 Packaging Box Gross Weight [kg] 530 Packagng Box Gross Weight 11bi 1.102 Dimensions (mmlinch) r002.0/34.4 (6�sta eb.drem Gar69 6 A4*^t^9 �leksl 175.0Id9 16-fl4 ale l0.3x0.1 triisklcs 8 �0/3lQ2 1 1 (•) liawvan eoa Cru. *R 1e� e-BSx12el03.05 tt." Kam Gde esglli C.W L `g A 4 4 8 N LG Electronics USA, {nc. Prodvet specifications are subject to change without notice. Solar Business OfviAan tG3751Y1 K-A6 AUS.pdf 2000 Millbrook or. 051721 {incolnshire, IL 60069 ® 2021 LG Elettronics USA, Inc. All rights reverted 40A 11.5T LG375N1K,A6_AUS.inOtl 2 5117121 10:56AM