Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDE-21-005353
Commonwealth of Official Use Only Permit No. BLDE-21-005353 E Massachusetts BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:3/18/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to pertorm the electrical work described below. Location(Street&Number) 22 SHEFFIELD RD Owner or Tenant Kenya West Telephone No. Owner's Address 22 SHEFFIELD RD,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system. (28 Panels 9.1 KW) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Lloyd R Smith Licensee: Lloyd R Smith Signature LIC.NO.: 15688 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:30 1ST ST, MELROSE MA 021764010 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $150.00 (Wom' at) MOZ11104 (ris6q -17,1120 c13 ll � . 1 ? e( � �t 1.7.-/ �'� Commonwealth,o/c�/77Yla&sachudelts //Oficial Use Only ` u , department o/_tire Serviced Permit No. C/ —5 353 c �'- t Occupancy and Fee Checked � . BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC).527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 2-i`) .OIv01 City or Town of: yormpUt-h To the Inspector of Wires: By this application the undersigned gtvesAgtice o `or h r iniztAn to perform the electrical work described below. Location(Street&Number a!�)1( 1. (7 tel I Owner or Tenant 1 ' a $ , Telephone No., B-5 y-9092 Owner's Address Is this permit in conjunctio with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building .J V,1 l i w Utili Authorization No. Existing Service 100 Amps la) /a1-1() Vo s Overhead Undgrd❑ No.of Meters 1 New Service Amps / Volts Overhead n Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: ` t ; Ille I _S C IIprdantiOIC Dior 5(,..(irr5) qoi 8 f6 s Completion of the following table may be waived by the Inspector of Wires. No. ran No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA - No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners �FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices Total No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW I No.of Self-Contained Totals: I Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ ther O Connection i No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water Kms, No.of No.of Data Wiring: _ Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eq_uivalent OTHER: � (y�Work: l O t ol�s�t Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical (When required by municipal policy.) Work to Start:y -1`1-OIrI7l\ Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such cover office. ge is in force,and has exhibited proof of same to the permit issuing CHECK ONE: INSURANCE [VBOND ❑ OTHER ❑ (Specify:) I certify,under IN,painsand penalties of per' ry,that the information on this ap• 'cation is true and complete. FIRM NAME: v _ , (CL., LIC.NO.: t Licensee: ,, Si II , Signature t Itl, Oji LIC.NO.: NO E8121- (If applicable. enter "exempt"in the license number Bus.Tel.No.: L cki • • Address: irlS 4KilnSt 41Sa1 a l dQLX} \ 0-2,TE0 Alt.Tel.No.:3 J •-iA '•-1-1-' *Per M.G.L. c.,147,s. 57-61,security work requires Department of Public Safety"S"License: Lic. No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below, I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent I Signature Telephone No. 1 PERMIT FEE:$ • GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: 2015 INTERNATIONAL RESIDENTIAL CODE 2020 NATIONAL ELECTRICAL CODE 2015 NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION SHEET INDEX PV 0.0-COVER SHEET PV 1.0-SITE PLAN S 1.0-MOUNT DETAILS E 1.0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS E 5.0-BONDING DETAILS GENERAL ELECTRICAL NOTES GENERAL STRUCTURAL NOTES 1.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL 1.THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE MEANS DESIGNED AND LISTED FOR SUCH USE.FOR ROOF-MOUNTED SYSTEMS- ROCK-IT RAIL-LESS SYSTEM BY ECOFASTEN.THE MOUNTING FEET ARE TO BE WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SPACED AS SHOWN IN THE DETAILS-AND MUST BE STAGGERED TO ADJACENT SURFACE. FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 2.ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE 2.UNLESS NOTED OTHERWISE SEES 1.0-MOUNTING ANCHORS SHALL BE 5116'LAG CORRECTED ON INSTALLATION. SCREWS WITH A MINIMUM OF 2.1/2"MIN PENETRATION INTO ROOF FRAMING. 3.SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE 3.THE PROPOSED PV SYSTEM ADDS 3.0 psf TO THE ROOF FRAMING SYSTEM 4.RAPID SHUTDOWN INITIATION TAKES PLACE WITHIN THE FIRMWARE OF THE 4.ROOF LIVE LOAD=20 psf TYPICAL-0 psf UNDER NEW PV SYSTEM. INVERTER.RAPID SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE 5.GROUND SNOW LOAD=30 psf VOLTAGE. 6.WIND SPEED=140 mph 5.SEE*E 1.0 AND'E 2.0 FOR DIAGRAMS-CALCULATIONS-SCHEDULE AND 7.EXPOSURE CATEGORY=B •22 Sheffield Rd, SPECIFICATIONS vivint.Solar' West Yarmouth,MA.. A SUI1fUT1 COMPANY 1800 ASHTON BLVD.LEHI,UT,84043 1877.404.4128 PHOTOVOLTAIC SYSTEM SPECIFICATIONS A MA Lia 17osbe 1sse6A SYSTEM SIZE-9.1 KW DC 17.6KW AC WEST RESIDENCE SHEFFIELD RD Sheffield Rd MODULE TYPE&AMOUNT-(28) JINKO SOLAR JKM325M-60HBL WITH SOLAREDGE P370 OPTIMIZERS WEST YARMOUTH,MA 02673 Sheffield Rd MODULE DIMENSIONS:(LIW/H)66.3/39.5/1.4 UTILITY ACCOUNT:1430 866 0183 INVERTER:(1)SOLAREDGE TECHNOLOGIES SE7600H-US METER:2283286 INTERCONNECTION METHOD(GRID-TIED):SUPPLY TAP Slt S43539796 ROC:MA-03 PV 0 O DRAWN BY:DIN DATE:03/1112021 u REVISION:0 PV STRINGS: ROOF SECTIONS: SYSTEM LEGEND VA PV STRING 1=14 MODULES ROOF PLANE 1 SLOPE=28° PV SYSTEM SIZE: PV STRING 2=14 MODULES ROOF PLANE 1 AZIMUTH=231° (N)9.100kW DC 7.600kW AC ROOF 1 MAT=COMPOSITION SHINGLE ROOF PLANE 2 SLOPE=28° ROOF PLANE 2 AZIMUTH=51° POINT OF INTERCONNECTION W O ROOF 2 MAT=COMPOSITION SHINGLE E EXISTING INTERIOR MSP TIED TO O UTILITY METER 2283288. A© ` ©((N)SMART METER.LOCATED WITHIN 10' MI O % % ` \ ` ®(N)PV SYSTEM AC DISCONNECT. \ ` (N)100 STRING INVERTER: OSE7600H11S / /\ 16, ISI MOUNTED O TEE OF EACH HBL MODULENS WITH P370 0PTNIIZERS MOUNTED ON THE BACK OF EACH MODULE. ' ' ' i X. • • \` , , , ®(MOUNTED WITlk. ( NCTION HSOLADECK) A A A A .0. L. i,.. . A A 4 A k ki. 6. 4449 I. 0 vivint.Solar° A sunrun coMTA\v 1800 ASHTON BLVD.LEHL UT,84043 1.877.404.4129 MA LIC:170848I 15688A 22 SHEFFIELD RD WEST RESIDENCE 22 SHEFFIELD RD FRONT OF HOUSE. WEST YARMOUTH,MA 02673 UTILITY ACCOUNT:1430 866 0183 a METER:2283268 SITE PLAN SNS 796 PV 1.Oz 4 ROC:IAA-03 DRAWN/11 DIN 1' SCALE:1/4"= -0" DATE:0341 1/2021 REVISION:0 9 • MOUNTING NOTES ROCK-IT COUPLNG MID CLAMP ROCK-IT CWPLNG Ak MW CWAPIV It AiROCK-IT 3.0 COUPLING `I ROCK-ITI ROCK-IT SLIDE MD CLAMP PEDESTAL ^ METAL ROCK-IT HEX FIANCE BOLT :�— FLASHING ® COUPLING SMELT '>1 300 SERIES SS Y ROCK-IT COUPLING SHELF ' _ \— ,— �� ISOMETRIC VIEW \\j __.:,..... CORP SHNGLES 1:1111$111.11".- SSIAG FT-LBS. �3 TORQUE=1312 FT-LBS. _ _ SIDE VIEW 5/16-x7 1T TIE PLATE HEX FLANGE BOLT SIDE VIEW300 SERIES SS 1 ROCK-IT 3.0 MOUNT DETAIL 8 ILSCO SGB-4 GROUNDING LUGS O 51.0 NOT TO scut s 1 "OT'O U.LLISTYIGFOR ECOFASTEN.2703 2 ROCK-IT 3.0 COUPLING ASSEMBLY _ ...__ WEAIHT.23o s 1.0 mro TOP VIEW MAX MOUNT SPACING LANDSCAPE MOUNT SPACING=64" CLAMP*ATTACHMENT,TYP LANDSCAPE CANTILEVER=21" CUMP•ATTACHMENT,TYP PORTRAIT MOUNT SPACING=48" CWPLMG,TYP PERMITTED COUPLNG,TYP PORTRAIT CANTILEVER=16" EVER SEE MOUNTING NOTES I I CLAMP SPACNG MOUNT SPACING SEE ROCK-IT SLIDE MOUNTING NOTES CLAMP FRAMING,TYP MODULE,TYP MIE = Immar MODULE METAL I'I MODULE,TYP FLASHING I r EPOM BONDED WASHER -.---FRAMING, TVP FRAMING,TYP - yjll FORMS WATERTIGHT SEAL ' I I L=UMVSCAPE CLAMP SPACNG MIENZENZEREEK- 4 PV SYSTEM MOUNTING DETAIL s MODULES IN PORTRAIT/LANDSCAPE i 1 L=PORTRAIT COMP SHINGLES S 1.0 AST TO SVAE s 1.0 NOf TO CLAMP SPACING 2-12" 3"MIN AND 6"MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE MM 5/18"OHM ONE HOLE STEEL STRAP CONDUIT SSLAG FT-LBS. PV RMAIN000 ESUTAG a �TORWE=1362 FT1B5. TO FRAMING OF EXBTING ® i4/ ROOF TYPE,PARALLEL c �y WITH PLANE OF ROOF CONDUIT MOUNT BRACKET vivint.Sola r 6" — __ I t 1T Asunrun COM PAN V SECTION VIEW /•'" 1800 ASHTON1.BLVD.877.401.4LEHI,129 LIT,84043 FLASHING OR TILE STRAP �� MA LIC:1708481 15688A --------------- - �.,.'t ....mr WEST RESIDENCE ,MA 02673 3 SECTION VIEW ——_—_—_—_—_—_—_—_ 22 SHEFFIELD RD EST s 1.0 NOTTOsule A PV ARRAY TYP.ELEVATION 7 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT:TT14308660183 51.0 N.T0F S 1.0 NOT TOS METER:2283288 g MOUNT DETAILS RO03 S 1.0 ROC:MA-03 DRAWN BY:DIN SCALE:NOT TO SCALE DATE 03/11/2021 = REVISION:0 .'u Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 9100 Tag Description Wire Gauge K of Conductors/Color Conduit Type Conduit Size m AC System Size(Watts) . 7600 1 DC-to-DC Converter Output(PV Wire) 10 AWG 2(V+,V-)B/R Free Air N/A m o Total Module Count 28 1 EGC(Bare) 6AWG 1 BARE Free Air N/A u ¢ N mo 2 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R FMC 1/2" y p Q M 2 EGC 12AWG 1(GRN) FMC 1/2" NW 2 'A' 3 DC-to-DC Converter Output(THWN-2) 12 AWG 4(2V+,2V-)B/R EMT 1/2" cc w 3 EGC(THWN-2) 12AWG 1(GRN) EMT 1/2" u N E 8 4 Inverter Output(THWN-2) 8 AWG 3(L1,L2,N)B/R/W EMT 3/4" ry A Q 4 EGC(THWN-2) 10AWG 1(GRN) EMT 3/4" Y 5 Service Feeder(THWN-2) 6 AWG 3(L1,L2,N)B/R/W EMT 3/4" 5 S GEC(THWN-2) 8AWG 1(GRN) EMT 3/4" s, Y Q z 150 Q V''^^ it / F, U C C > C � + Q m lo ar m as V O1 N Q Sole rEdge SE7600H-US g ooq Conforms to ANSI 0 C12.1-2008 vs K PV System SMART Meter Z m Point of Interconnection,Supply Side 7 External Rapid Shutdown MURRAY LCOO2GS 705.11 > Z Square W ,-ill' �p Disconnect Sare D 240V/60A 2 POLE W —m DU222RB 240V/60A BREAKER BOK WITH 75'C Co Infused,NEMA3R,with TERMINATIONS Existing Bryant .1 STRING 2:14 PV 0 Q 14 �/ 75Y terminations 0 240V/1O0A Service Panel, Z Z r` MODULES Single Phase,with lOOA SHEET W/OPTIMIZERS . 11. 5' �% Main Disconnect Yf { NAME: } ■ -v t, 4 _.- LINE m c L ._ 100A c 3 STRING 1:14PV 0 © 14 \ { = N MODULES NEMA 3R lunch on Box /y� 4 LO Q M D W/OPTIMIZERS . . \l SHEET ttr r 4 Q 40A Q NUMBER: ! -.. — - 1 - 28 PV MODULES PER INVERTER=9100 WATTS s e nife'AC Y STC a e Minimum GEC size 6 Disconnect AWG copper W • Inverter/Optimizer Specs PV Module Rating @ STC Conductor Calculations m Optimizer SolarEdge P370 Module Make/Model Jinko Solar JKM325M-60HBL c Wire ampacity calculated from 310.16&17 as appropriate with ambient temperature o rn DC Input Power 370 Watts Max.Power-Point Current(Imp) 9.68 Amps e calculations from Table 310.15(6)(1)&310.15(6)(2)and raceway fill adjustments from 310.15(C) .. m N m DC Max.Input Voltage 60 Volts Max.Power-Point Voltage(Vmp) 33.6 Volts c o 0 DC Max.Input Current 13.75 Amps Open-Circuit Voltage(Voc) 41.1. Volts (1).Conduit on the roof shall be installed no less than 1"above the roof deck. W PV Circuit conductor ampacity is constrained using the 75T column with the continuous duty DC Max.Output Current 15 Amps Short-Circuit Current(Isc) 10.2 Amps uprating or the 90T column with the relevant ambient temperature and raceway fill adjustments cc LLC Max.string rating inverter dependent.See SE documents. Max.Series Fuse(OCPD) 20 Amps without the continuous duty uprating per 690.8(B),whichever results with a larger wire size. a+ " ° ou Inverter Make/Model SolarEdge SE7600H-US Nom.Max.Power at SIC(Pmax) 325 Watts Non-PV Circuit conductors use the ampacity in the 75"C column or the 90'C column with the N E a CEC Efficiency 99 % Max.System Voltage 1000 VDC(UL/IEC) relevant ambient temperature and raceway fill adjustments,whichever is less(110.14(C)& Y AC Operating Voltage 240 Volts Vac Temperature Coefficient -0.28 1 %/C 310.14(A)(2)).The rating of the conductor after adjustments shall be greater than,or equal to, j Cont.Max Output Current 32 Amps the continuous duty uprated current. DC Max Input Current 20 Amps ASHRAE 2017-BARNSTABLE MUNICIPAL More information about conductor calculations can be provided upon request. Input Short Circuit Current 45 Amps Highest Monthly 2%D.B.Design Temp.:29.5'C Calc.Ex:Wire Ampacity x Ambient Temp.Corr.Factor s Conduit Fill Adj.Factor>=Output Current Max Output Fault Current 40 A/20 ms Lowest Min.Mean Extreme D.B.:-19.2'C (Tag 1 Under Array): DC-to-DC Converter Output:10 AWG rated 30 A, 30 A>=18.75 A s_. > (Tag 2 Attic): Power Source(s)Output Calc:705.11 DC-to-DC Converter Output:12 AWG rated 30 A, 30 A x 0.76 x 0.8=18.24 A>=15 A O as (Tag 3 On Roof): CO Service Rating:100 Amps DC-to-DC Converter Output:12 AWG rated 20 A, 20 A>=18.75 A } u (Tag 4 Exterior): PV Breaker Rating:40 Amps C Output: C 4OA<=100A,OK Inverter 8 AWG rated 50 A, 50 A>=40 A _ (Tag 5 Exterior): e> C C Service Feeder:6 AWG rated 65 A, 65 A>=60 A • ` .. > Q m fat e U I N elC I Other Notes •Designed according to and all code citations are relevant to the 2020 National Electrical Code. g N •All interior raceways carrying DC current shall be metallic. CI ., N d' Voltage and OCPD Calculations(690.7,690.9) >Z > Zu PV Source Max Circuit Voltage:Module Voc x(1-(6T x Voc Coeff))[art.690.7(A)) — JKM325M-60HBL:41.1 V x(14(25 C—-19.2 C)x-0.28%))=46.19 V<=60 V 4 4 g m IA IA rn Inverter Output Circuit(s):Listed Output Current x 1.25[art.690.9(6)] SHEET Inverter 1:SE7600H-US Max Output=32 A x 1.25=40 A<=40 A(OCPD) NAME: System output current w/continuous duty=40 A<=40 A(System OCPD) 4e co m 2 o. SHEET NUMBER: N W i • All AC Disconnecting Means-AC Disconnect(s), Conduit,Raceways,and 1-Boxes(Labeled Every 10')and Installed within 3 ft of Rapid Shutdown Switch,Reflective,and shall be placed on Combiner Panels and Load Centers•er 690.54 Inverter 1 DC Disconnect•er 690.53 both Panel Exterior&next to Main Disconnect•er•er 690.56(C 2 0 MAXIMUM DC VOLTAGE Reflective•er690.31(D)(2) PHOTOVOLTAIC AC DISCONNECT m RAPID SHUTDOWN SWITCH OF PV SYSTEM: 480 V PHOTOVOLTAIC POWER SOURCE MAXIMUM AC OPERATING CURRENT: 32 A W Q rn FOR SOLAR PV SYSTEM NOMINAL AC OPERATING VOLTAGE: 240 V 73 LL 7! & Wry s PV 5 tern Disconnects per 690.13(B PV with Rapid Shutdown Switch,Installed within 3 ft of Service Disconnecting 3 n E a PV SYSTEM DISCONNECT Means with min.3/8"black capitalized text on yellow background&3/16" r .Z- black ablack ca•italized text on white bac :round•er 690.56 C - .P µ T' Lr TURN RAPID SHUTDOWN 0 Q SWITCH TO THE (I) SHUTDOWN/SY8 M � 4z J C AND REDUCE _ D • L SHOCK HAZARD . ` c N IN ARRAY •�` N Plaque/Directory at Service Disconnecting Means per 690.56(6),&705.10 ' < ' v Ili All Disconnecting Means-AC&DC u` CAUTION: MULTIPLE SOURCES OF POWER Disconnect(s),Load Centers,and Combiner POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Panels per 690.13(3)&690.15(C) 01 FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS g ELECTRICAL SHOCK HAZARD SHOWNTERMINALS ON THE LINE AND cc rz,. o LOAD SIDES MAY BE ENERGIZED m s IN THE OPEN POSITION r m Z _ -- Power Source Output Connection,Adjacent to z III AT: Back-fed Breaker•er 705.12 B 3 2 a a - ---- z z ^ 0 METER AND MAIN POWER SOURCE OUTPUT CONNECTION SHEET / SERVICE DO NOT RELOCATE NAME: THIS OVERCURRENT PROTECTION DEVICE ro / AC DISCONNECT Dual Power Sources in Main Service Panel E =" w y DC DISCONNECT and Sub Panel s ••er 705.12 C ••SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER 3 La a 1, LOCAL AH1 REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS• SHEET --— --- DUAL POWER SOURCE SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING NUMBER: --IREQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS SOURCES:UTILITY GRID OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR AND PV SOLAR ELECTRIC SYSTEM WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO M WITHSTAND THE ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W i WARNING SITE PLACARD SHOWING ADDITIONAL POWER SOURCE m o MAXIMUM DC VOLTAGE RAPID SHUTDOWN SWITCH DUAL POWER SOURCE CO,y OF PV SYSTEM •••V 4 7 AND DISCONNECT LOCATIONS.PLACARD SHALL BE 10 FOR SOLAR PV SYSTEM SOURCES:UTILITY GRID n MOUNTED ON EXTERIOR OF ELECTRICAL PANEL AND PV SOLAR ELECTRIC SYSTEM 2 p.,11 R w f 'a C WARNING MAIN BREAKER DE-RATED y u 2 PHOTOVOLTAIC POWER SOURCE ( ` SOLAR PV SYSTEM EQUIPPED TERMINALS ON THE LINE AND q DUE TO SOLAR CIRCUITS _ �—+� WITH RAPID SHUTDOWN \�/O LOAD SIDES MAY BE ENERGIZED 1 ***AMPS MAX ALLOWED 3 N E a IN THE OPEN POSITION DO NOT UPGRADE ',F. - WARNING PHOTOVOLTAIC AC DISCONNECT POWER SOURCE OUTPUT CONNECTION 3 PV SYSTEM DISCONNECT ( ' MAXIMUM AC OUTPUT CURRENT:•••A ® � J� NOMINAL AC OPERATING VOLTAGE:***V DO NOT RELOCATE THIS OVERCURRENT PROTECTION DEVICE L > 0 _ ROOFTOPARRAV O z 4 • � } U C C > C ^' .i •� O ®IF APPLICABLE ' Q M I m w 1 4 Op V s INSIDE 0 0 N © n PANEL i P �J• O O � O O 9 O 4 5 � VERY10'AND O,o,y s °§ WITHIN 1'OF ELBOWS 'e P� ON .7 Ci 4-...',..- O > j ao M > Z � DC iiw -. 0 9,pAi O _. _. —w M °° 01 e. DISCONNECT a a �`''• INSIDE ZZrI _____ ___ ___, -__4 SHEET ROOFTOP O COMBINER PANEL VISIBLE/LOCKABLE A/C VIVINT SOLAR METER VISIBLE/LOCKABLE A/C SUB PANEL MAIN SERVICE DISCONNECTNAME: JUNCTION BOX 2 SOLAR INVERTER (WHEN USED) DISCONNECT(WHERE (WHERE REQUIRED) REQUIRED) (WHEN REQUIRED) DISCONNECTPANELbe E 2 d •••-value calculated for each 3 3 a TYPICAL SOLAR GENERATION INSTALLATION account,for specific value see the (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) previous warning label page SHEET NUMBER: •SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705,UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS•SIGNS/LABELS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B)AS REQUIRED PER ARTICLES 690 AND 705 AND SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY SIGNS AND LABELS•SIGNS/LABELS SHALL BE REFLECTIVE IF REQUIRED TO BE SO PER ARTICLE 690•SIGNS/LABELS MEETING REQUIREMENTS OF ARTICLE 690 SHALL HAVE NO SMALLER THAN 3/8"WHITE TEXT ON RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED•SIGNS/LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN•SIGNS/LABELS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE Q ENVIRONMENT INVOLVED•SIGNS/LABELS SHALL NOT COVER EXISTING MANUFACTURER LABELS W i ��=BONDING PATH MODULE FRAME -�,. ROCK-IT COUPLING „ \,i v� _�. , i MID CLAMP Ij, ,. .antra, .- - 1 .A - , ■a �� �� (iIMODULE � II 1 - L �.j" ' ROCK-IT ROCK-IT SLIDE UL2703:2015 LISTED PEDESTAL n- - BONDING CLIP ' NI- m all iii e., BONDS SOLAR MODULE 1 -1. : r FRAME TO OPTIMIZER r OR MICRO-INVERTER !'''- OPTIMIZER MOUNTED I1 TO MODULE FRAME 0 ROCK-IT INTEGRATED BONDING WITH UL2703 - : 1 NOT TO SCALE j •1 ©OPTIMIZER BONDING DETAIL WITH UL2703 NOT TO SCALE PV MODULE TO ACT AS AN ACTIVE GROUNDING COMPONENT TO EGC ii II•lig.mili in mils 1 EN 0 GROUNDING LUG(SEE S1.0 DETAIL#2) •---• E-W BONDING PATH. mII N-S BONDING PATH,SEE DETAIL#1. EI ROCK-IT COUPLING VIV111t.Solar` I p -11 -11 11 Asunrun COM'ANY 1800 ASHTON BLVD.LEHI,UT,81043 1.877248"1 28 ❑ ROCK-IT COUPLING MHO 170848 EHI,UA WEST RESIDENCE 11 = 11 11 11 22 SHEFFIELD RD WEST YARMOUTH,MA 02873 UTILITY ACCOUNT:1430 888 0183 METER 2283288 1 OSio SYSTEMSCABONDINGLAYOUT WITH UL2703 BONDING DETAILS '� E 5.0 E DRAWN BY:DIN SCALE:NOT TO SCALE DATE:03/11/2021 REVISION:03.