HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 5 Lot /4 / Zone of Contribution: In Out %� Acreage //C.-1
Commercial: Residential: 1----
Street: 6 R D G i S R.4 ---
Village: Floor Plan: {------ #Bedrooms: /
Owner: Installer: _5 l�e.,...k �,�t r L"7X e . v��%A..
Address: Phone:
Phone:
Builder: Engineer: R o b i c l (.,3��e LTD
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received
2.Date of soils exam and percolation test not older than 2 years 10
3. 4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands Vr-
7. Septic tank minimum 10 ft from foundation, deck Var.: 1
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 17 -
9. Leaching minimum 100 ft from wetlands Var.: 1
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 'A"preferred
18. System meets breakout requirements PVC liner: Wall: f V
19. Specified tee sizes are proper, gas baffle on outlet tee .
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal V.
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox t j
24. Manhole covers within 6"of grade, pump chamber cover to grade ,/
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed dV-
29. Vent provided if leaching below 3 feet,under driveway/parking
lr-
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall- -commercial: -- l '
•
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature f r.------
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee,installer signature t .
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: -� c o:oa