HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 5 Lot /4 / Zone of Contribution: In Out %� Acreage //C.-1 Commercial: Residential: 1---- Street: 6 R D G i S R.4 --- Village: Floor Plan: {------ #Bedrooms: / Owner: Installer: _5 l�e.,...k �,�t r L"7X e . v��%A.. Address: Phone: Phone: Builder: Engineer: R o b i c l (.,3��e LTD Address: Phone: Phone: N/A YES NO 1. Required#of copies received 2.Date of soils exam and percolation test not older than 2 years 10 3. 4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands Vr- 7. Septic tank minimum 10 ft from foundation, deck Var.: 1 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 17 - 9. Leaching minimum 100 ft from wetlands Var.: 1 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 'A"preferred 18. System meets breakout requirements PVC liner: Wall: f V 19. Specified tee sizes are proper, gas baffle on outlet tee . 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal V. 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox t j 24. Manhole covers within 6"of grade, pump chamber cover to grade ,/ 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size 28. Septic tank/pump chamber to be factory waterproofed dV- 29. Vent provided if leaching below 3 feet,under driveway/parking lr- 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall- -commercial: -- l ' • 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature f r.------ 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee,installer signature t . 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: -� c o:oa