Loading...
HomeMy WebLinkAboutEngineer Planrn 39 Oi 0 0 Ki N 0 N I v v 0 m M rn 0 r`> L 0 0 0 of m v 0 M i N N O N 0 U v a U 0 f= 0 m v a 0- U a 0 SURVEY WITH EXISTING TOPOGRAPHY, UTILITIES AND PROPERTY BOUNDARIES PROVIDED BY DEMAREST LAND SURVEYING, PLS DATED 20 DECEMBER 2022. ZONEi UNpPFz'fi' L a 3 WATER GATE MAP 59 PCL 160 LOT 30 / 11,621± S.F. X SOF��'3 00 G 10' 10.5' 28. LEGEND - O a (0 SOIL TEST PIT C + EXISTING CONTOUR �oln PROPOSED CONTOUR MAP �59 $_� OVERHEAD ELECTRICAL PCL 162 W~ BURIED ELECTRICAL MUNICIPAL WATER G \ NATURAL GAS LINE 38 DAMS RD ASSESSORS MAP 59 PARCEL 161 SITE PLAN - SCALE: 1"=20' I 0 20 40 9" MIN. e* _ 3" MIN. .:A 6" MIN. 10" MIN. 12" MAX. 3" MIN. 6" MIN. ZABLE FILTER 2 12" MAX. -v PROPOSED 1,500 GALLON 1- COMP. SEPTIC TANK (H-10) 98.5 ± 111110A,"�r�JJrt 8 =�M • r MAP 59 PCL 153 N p 4 j � N'' tiO�j -- BENCHTVIARK TOP OF CONCRETE BOUND EL=100..0' (ASSUMED) / EXISTING CESSPOOLS. SEE NOTES. PROPOSED H-10 1-COMPARTMENT 1,500 GALLON SEPTIC TANK PROPOSED H-10 DISTRIBUTION BOX MAP 59 11.6 PCL. 152 \ SAS: 5 INFILTRATOR 3050 CHAMBERS 1 3.5' STONE ON SIDES, VON ENDS \ 11.25'W x 37.58'L x 2.5' H 1 4" PVC INSPECTION \ PORT f H10 RISER AND COVER TO WITHIN 6" OF FINISHED GRADE FILTER FABRIC PLACED ON TOP AND SIDES OF SAS �- BOTTOM ON LEVEL, STABLE BASE MECHANICALLY COMPACTED WITH 6" CRUSHED STONE LEGEND WATER SURFACE ELEVATION C GAS BAFFLE MAP 59 PCL. 151 VARIANCES ! SITE NOTES 1. PROPOSED SYSTEM COMPONENTS ARE NOT LOCATED IN A FLOOD ZONE. 2. THE PROPERTY IS LOCATED WITHIN A ZONE 11. 3. NO DRINKING WATER WELLS WITHIN 100 FEET OF PROPOSED SYSTEM. - r l VICINITY MAP LOCUS NOT TO SCALE 38 DaviS Rd GENERAL NOTES 1. THIS PLAN IS INTENDED FOR THE DESIGN OF THE SEWAGE DISPOSAL SYSTEM ONLY AND IS NOT TO BE USED TO ESTABLISH NEW OR EXISTING PROPERTY LINES OR DWELLINGS. 2. LOCATION OF WATER, GAS AND ELECTRIC UTILITY LINES IS APPROXIMATE. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING DIGSAFE AT 1-888-344-7233 AND THE YARMOUTH WATER DEPARTMENT PRIOR TO CONSTRUCTION. 3. INSTALLATION SHALL BE IN ACCORDANCE WITH THE STATE ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.000), THE LOCAL BOARD OF HEALTH REGULATIONS, THE MICROFAST 0.5 UNIT MA DESIGN AND INSTALLATION MANUAL, AND THE CULTEC SEPTIC MA DESIGN AND INSTALLATION MANUAL 4. THE CONTRACTOR MUST HOLD A VALID INSTALLER LICENSE IN THE TOWN OF YARMOUTH. 5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND THE LOCAL BOARD OF HEALTH OF ANY CHANGES TO THESE PLANS. 6. CONTRACTOR SHALL CALL FOR INSPECTIONS AND APPROVALS FROM THE BOARD OF HEALTH AND THE ENGINEER AFTER: 6.1. EXCAVATION OF SAS AREA EXPOSING THE BOTTOM OF SYSTEM. 6.2. INSTALLATION OF SYSTEM COMPONENTS PRIOR TO BACKFILL. 7. ALL PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE SPECIFIED. 8. FINISHED GRADE OVER THE SAS SHALL HAVE A MINIMUM 2% SLOPE. 9. EXISTING SYSTEM TO BE PUMPED DRY, CRUSHED AND FILLED WITH SAND. IF ANY COMPONENT LIES WITHIN S OF THE PROPOSED SYSTEM, THE COMPONENTS SHALL BE CRUSHED, REMOVED AND REPLACED WITH TITLE 5 FILL. 10. NO GARBAGE GRINDER SHALL BE INSTALLED AT THE EXISTING DWELLING. GARAGE 113R\NEAEY E I KITCHEN I BATH I BED LIVING ROOM BED FLOOR PLAN (UNFINISHED BASEMENT) Design Tie -out Table (in feet) LOCATION X Y A (SAS corner 27.5 42.7 B SAS corner 55.9 29.6 C (SAS corner) 61.7 40.6 D (SAS corner) 37.9 5i.0 9" MIN. TO 36" PERFORATED - MAX. COVER - SAS PIPING - - - - - - - - - - - - - - - - - - - - - 51NFILTRATOR 3050 UNITS 37.58' -- SOIL ABSORPTION SYSTEM (SAS): 5 INFILTRATOR 3050 CHAMBERS 3.5' STONE ON SIDES, 1 FT ON ENDS 11.26 W x 37.58'L x 1.83'H 41NCH INSPECTION PORT TO GRADE. TOS BOS SYSTEM PROFILE NOT TO SCALE Yarmouth Health Department APPROVED a e-5 Date SOIL EVALLLATION TEST PIT LOGS Address: 38 Davis Rd Yarmouth, MA Test Date: 12/29/2022 Soil Evaulator: Speakman Test Hole 1 DEPTH (inches) HORIZON / LAYER TEXTURE(USDA) COLOR (Munsell) 0-5 A Loamy Sand 10YR3/1 S-26 B Loamy Sand 10YR6/8 26.126 C Medium Sand 10YR7/4 Notes: No gioundwaterobserved. Percolation Test Location: Depth Results Rate THl I QI, could notsaturate e2 min/inch. DESIGN CALCULATIONS 4 Bedrooms x 110GPD/Bedroom 440 GPD SEPTIC TANK (Per 310CMR15.233) Single Compartment: 2 Days Flow 880 gallons Mi numum Total Volume: 1500 gallons SOLI ABSORPTION SYSTEM: loading Rate (310CMR.15): 0.74 GPD/sq It Area =440GPD/0.74GPD/sgft 594.6 sgft Select S Infiltrator 3050 Chambers: 3.5 ft stone on sides and 1 ft stone on ends Bottom Area = 11.25 ft x 37.58 ft 422.8 sq ft Side Wall Area = 2 x (11.25ft +37.58ft) x 1.83 ft 178.7 sgft Total Leaching Area = Bottom + Side Wall Area 603-5 sgft Allowable Flow =Area x 0.74 GPD/sq ft 445.1 GPD Schedule of Invert Elevations Location Design As -built 4" @ sewer invert @ foundation 96.70 4" @ septic tank in 4" @ septic tank out 96.30 96.05 3" @ D-boxin 95.77 3" @ D-box out 95.60 3" @ SAS Chamber in 95.34 Top of Units (TOS) 96.01 Bottom of System (BOS) 93.51. JAN `I 'I 'JU'Z3 HEALTH DEPT. RQbIAL WATER LTD ENGINEERING SERVICES 85 Courtland Street Providence, RI 02909 P: +1 (508) 954 0677 E: jay@robialwater.com CONSULTANTS: SPEAKMAN EXCAVATING LLC 235 Great Western Rd Dennis, MA 02660 P: +1 (508) 432 5565 E: info®speakmanexcavating.com I I I I I N OF M q,, o� JAY THRASHER CIVII_. u No. F I I I I I i I I I I �LSN OF MAgsq I DN A oyG I SPEAKMAN N No. I A P� I 7gND SURVE C)4 I I I I-------------J No. REVISION/SUBMISSION DATE COPYRIGHT 2022 - Robial Water Ltd. This document, and the ideas and design concepts incorperated herein, as an instrument of professional service, can not be used, in whole or in part for this or any other project, without the written authorization of Robial Water Ltd. PROJECT No. t5s.2022.051 SHEET TITLE: SITE LAYOUT SYSTEM DESIGN SHEET SIZE: 18 IN. X 24 IN. (ARCH C) DATE: 9 January 2023 _ SHEET NUMBER: SHEET 1 of 1 PROJECT: RESIDENTIAL ONSITE WASTEWATER TREATMENT SYSTEM NEW CONSTRUCTION 38 Davis Rd Yarmouth, MA