Loading...
HomeMy WebLinkAboutBLDE-22-000738 RAlt Commonwealth of Official Use Only Massachusetts Permit No. BLDE-22-000738 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT/N INK OR TYPE ALL INFORMATION) Date:8/9/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 405 STATION AVE Owner or Tenant HAGERTY JAMES F Telephone No. Owner's Address 26620 AUGUSTA SPRINGS CIR, LEESBURG, FL 34748-1226 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters New Service Amps Volts Overhead 0 Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system.(5.04 KW 14 Panels) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. TTotal No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Eauivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: JAMES E PRECOURT Licensee: James E Precourt Signature LIC.NO.: 12418 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address:244 S WORCESTER ST,APT 3,NORTON MA 027663445 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature pp Telephone No. PERMIT FEE: $150.00 +mac 00-61*J01,1(.* q/1617-4 c /7 /2 t LCEIVED �G 0 � 2021 --.... • . _......_ _.� _.......... . • .- _ Omai�tv�eodb BUILDING DEPARTMEN 1. �? aAt sit 7� . c� �s PermkNo. t:�--(073 g ' re�.rii+a Jersimer • B_Oepomy and Fee Choked BOARD OF FIRE PREVENTION REGULATIONS .1107) Ileaebhodal • APPLICATION FOR PERMIT•T�PERFORM ELECTRICAL WORK work b AB work bepeetr eeaaed le aeo.'danes with BJeatrlod Code Goa 327 CM 12.00 (MUSS Data 08-05-2021 . City or Town of: Yarmouth Tb the (Prim: • By this applioadon the vad ed des'Dodos clbls of kr ismreknit to knat die�wae dausNnd Mrs. Locution Wrest 4*Number)405 Station AVE jjr • Thant ant James Hagerty • Telephone Na 774-810-1321 I Owner's Address 405 Station AVE Yarmouth MA 02664 t Jr this psrmft eoajtmedonwith a btelldogpawettt Yes Q No 0 (Omit ApprepAcsb0 I fe pees ofBvBdind Residential Willy Authorised=Ni. I _datha_Service. 100 Amp. itro 090Yelts Overbilled® Resign!0 N..et'ldm u: i ' • ifteiworise100 Asp /ao/syn Vas Overhead© Ondkrd 0 Ne.efM Lets 1_ Number of leaders and Aapadty • Localism and Nature of?reposed Zlsutrieul Wett:Rooftop Installation of Solar Panels 15.04 kW 1 14 modules • ONIIIIilan ifs*l6Soeelta ay l woke r Os .` afrfraa. • I + OLa Recessed mahrdr ee I K (Pada*Nes ! :. . • i:Laminaire OM1ete .. etRdTubs • Osasaters XVI • • of Lenafnaires • swims*,Peel Absa ❑ '•y ❑ 11 rna Outlets , S , ALAVA Oben . aidr Cbud. , Odlertbj Dentia t: .' p IL-71710171111111A" ,' . :^;l.--r,'r- , I • • ofDtyats ,: digA.ppli" ' lit -===-r 0 e +.�z.. K�iQRI�t a e:17eni l r' b iejj . • . .asea,,SeBathtubs I '. ofMotors •. • Total ap Ne.!Mobs /e']ia �t • oz> $1500:(f0d amidal rishiproemial, Piker. _ _ Wait to Start: 08-18-2021 b spaotbae to be requested is adootebaoe with MBC Rads 10.and epos eau phiee. INSURANCE COVERAGE: Unitas Itnived by the owner.so permit 1hr the pedbommes oddeeairetwedt req blue stubs tbo.gmuneprovides peoad'ofliability i sursuceboiodio mpleledopentiodon m or itssebliatbdegairtiuet.Ms • • andataigned oertMos•tbit such coveralls is in taus,and bet edtbited prolamine to the ponds iambs aloe e CHECK ole: INSURANCE ®.BOND 0 OTFER 0 Iare,wrier the paha aalpeardtia d thetas b lkaseat.n mak cppl edea k rue and esapbdq ! MN NAM!: StJ - y c u LIC.NO.: Kjl b ill . Licensee: 1 • stew L W.NO.:'r. , ; : • tralvTlaeik aerr 9aaeaa B. Maaeert J� . TIL �rT "�'_4 s •P�OL a. 47 a.3I.security work re4 s D irtmrto<Pa a sex Q� Liu:.Na. ' °WM'S DNSURANCt WAIYYR: I es aware that the Limns dors Nit have the Milky iteenera coven"auMlly required Abyyelaw.at . By my below,Mak waive this requirement.I ass the(allude see)0 your D owes spat. gwt Tdephoae K._., �...1'�PERMI2771z$ i ,• DIRECTORY NEW PV SYSTEM: JAMES F HAGERTY NOTES ,7---PV2 NOTES �, PVt PROJECT 405 STATION AVE YARMOUTH, MA 02664, USA PV3 PLOT PLAN PV4 SITE PLAN 41.683182, -70.205833 �,_______-! PVNS ATTACHMENT DIAGRAM PV8 THREEATTACHMENTDIAGRAM ELEVATION PV SYSTEM RATING (DC): 5.04 KW PV7 THREE UNE DIAGRAM PV8 BILL OF MATERIALS SUMMIT PV9 WARNING LABELS PV10-PV13 DATA SHEETS ENERGY SYSTEM INFORMATION slt % - Veit DC SYSTEM SIZE 5.04 KW Na, /"/ z ,�\ ;r ti ti "'sr i- 9' EPC COMPANY: AC SYSTEM SIZE 3.8 KW k.' l I 't - '",r Y r ,�; Y }� *•_.. s • SUMMIT ENERGY GROUP DC/AC RATIO 1.33 ``#� / \� „,,,t,„,-. a -r.S ..T.:.,^w 'i:�'�- - REC THAN PEAK SERIES BLACK / _ ,+ '° h'�' y I* •1r. . a- p� 4�k, ,, * °' 1i 293 ULINIT Y2 INDUSTRIAL PKWY, MODULE 360TP4 360W R;.. ! r UNIT 0.189,USA , . ` 0^ 40V , - ,; T, `,w � � ..S a''il'r`R �,kil,,, MA 02189.USA SOLAREDGE TECHNOLOGIES, �” • 888578-8848 MLPE/INVERTER �.. ® _ - www.summitsolarenergy.com P401,SE3800H-US .. aS " �t - CUSTOMER DETAILS RACKING IRONRIDGE a, y `( <.,"�. ATTACHMENTS FLASH FOOT 2 f.,.j 5* j �) � I p• .. _ Q TOTAL ARRAY AREA 265 SOFT. III...„-;..14,; . - f } NO.OF MODULES 14 �,. r '.L.. - F n <7 Mi ARRAY 1 AZIMUTH 224° � . - W W O O ARRAY 1 PITCH 32' I t (D Z ry�1 Q o Z ARRAY 2 AZIMUTH - II. 3..' 1F r,L b -� .. i , -4`.6", LL w >c� F ARRAY2PITCH - -. �� ,•. • " �'4". ",,.-� ARRAY 3 AZIMUTH - - -fes' - CO O: Q N .. ARRAY 3 PITCH - ,f. A lja, 4. ..._ ZO Z ARRAY 4 AZIMUTH - H- _ W ARRAY 4 PITCH - � a Cn i ARRAY 5 AZIMUTH - M) o ARRAY 5 PITCH - Y UTILIAVERTY - O AERIAL VIEW © STREET VIEW UTILITY NAME EVERSOURCE PROJECT ID:MAEVE5.04-850 • REMOTE YES NOT TO SCALE NOT TO SCALE PREPARED ON:08/05/2021 MONITORING DRAWN BY: V.N. SITE DETAILS /� INTERCONNECTION DETAILS I CHECKED BY: S.T. ASHRAE EXTREME LOW 3.2°F(-18°C) % ` NEW SUPPLY SIDE AC STAMPED BY: S.W. ASHRAE 2%HIGH 82.4°F(28°C) ,\ DESIGN ENGINEER POINT OF CONNECTION CONNECTION PER NEC UTILITY:EVERSOURCE CLIMATE DATA BARNSTABLE MUNI BOA, / ,\ SIDDHARTH TEMBURNI ARTICLE 705.12(A) 1 PE STAMP WITH SIGNATU _ (WMO:725087) • NABCEP PVIP CERTIFIED UTILITY SERVICE 120/240V1 SOURCE MA,USA SID@SUMMIT.SOLAR 100A MAIN BREAKER,100A VMND SPEED 133 MPH(ASCE 7-10) ,\ ELECTRICAL PANEL PANELIBUSS RISK CATEGORY I . / PROFESSIONAL ENGINEER IN OF `1 MODE OF INTERCONNECTION BTM,20A BACK FEED '.�p� ,\ , / ■ SCOTT WYSSLING � + ' WIND EXPOSURE B t W CONSULTING SERVICE ENTRANCE OVERHEAD ®[ °t CATEGORY ,\ I P.E.STRUCTURAL,PP,CME Te wv.sc.� '' GROUND SNOW LOAD 30 PSF L A `� / (0):a01)8743463 ! \I' DOCUMENT DESCRIPTION ,\ N'f, ti : APPLICABLE CODES&STANDARD ` THIS DOCUMENT WAS BEEN PREPARED FOR THE PURPOSE OF �\,y a`:, .!- -FS✓� MASSACHUSETTS BUILDING SYSTEM WITH EDESCRIBING HNOUGH DETAIL O DEMONSTRATEE DESIGN OF A PROPOSED COMPLIANCC EWIRTH / N/'OV,,C';% BUILDING CODE,9TH EDITION,AS AMENDED SCOPE OF WORK APPUCABLE CODES AND REGULATIONS.THE DOCUMENT SHALL NOT UQ80 CMR) THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS.THE BE REUED NSTALLAO TI IN INSTRUCTIONS AS A .CONTRACTITUTE FOR TOR SHALL INSTALL MASSACHUSE ITS ELIC TRICAL SOLAR PANELS WILL BE RACKED USING A PRE-ENGINEERED RACKING EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS ELECTRICAL CODE(527 CMR 12.00)NFPA 70E (i) PLOT MAP THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC AND NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY PAGE DESCRIPTION TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL PV 1 (2017NEC) THAT OVERRIDES THEM.CONTRACTOR IS RESPONSIBLE FOR MASSACHUSETTS COMPREHENSIVE NOT TO SCALE UTILITY USING MEANS AND METHODS CONSISTENT OATH THE RULES VERIFICATION OF ALL CONDITIONS,DIMENSIONS,AND DETAILS IN THIS FIRE FIRE SAFETY CODE(527 CMR 1.00) ENFORCED BY THE LOCAL UTIUTY AND PERMITTING JURISDICTION. DOCUMENT. PROJECT SUMMARY 2.1.1 SITE NATES. LEGENDS 2.1.2 A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 2.4.9 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 REGULATIONS. THROUGH 250.106.IF EXISTING SYSTEM IS INACCESSIBLE,OR INADEQUATE,A 2.1.3 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250.NEC 690.47 UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. AND AHJ. A 2.1.4 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING,MECHANICAL OR 2.4.10 ACCORDING TO NEC 690.47(C)(3),UNGROUNDED SYSTEMS INVERTER MAY SIZE DC A JUNCTION BOX BUILDING ROOF VENTS. DEC ACCORDING TO EGC REQUIREMENTS OF NEC 250.122.HOWEVER.DC DEC TO BE -Ca- 2.1.5 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED UNSPLICED OR IRREVERSIBLY SPLICED. LOi ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 2.4.11 IN UNGROUNDED INVERTERS,GROUND FAULT PROTECTION IS PROVIDED 2.1.6 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN BY"ISOLATION MONITOR INTERRUPTOR,'AND GROUND FAULT DETECTION rU S U M M i T ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURERS PERFORMED BY'RESIDUAL-CURRENT DETECTOR.' INSTRUCTIONS SUCH THAT T THE ROOF COVERING SERVES TO PROTECT THE 2.5.1 RCONNECTION NOTES: BUILDING OR STRUCTURE. 25 2 OADSIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 690.647: ENERGY 2.2.1 EQUIPMENT LOCATIONS (BA 2.2.2 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.5.3 THE SUM OF THE UTILITY CCPD AND INVERTER CONTINUOUS INPUT MAY NOT 2.2.3 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)1. PV INVERTER EPC COMPANY: OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31(AMC)AND NEC TABLES 2.5.4 WHEN SUM OF THE PV SOURCES EQUALS>100%OF BUSBAR RATING.PV } L 310.15(B)(2SA)AND 310.15(B53SC). DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE SUMMIT ENERGY GROUP 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES BUS FROM THE UTILITY SOURCE OCPD[NEC 705.12(D)(21(311 ACCORDING ACCORDING TO NEC 690.34. 2.5.5 AT MULTIPLE INVERTERS OUTPUT COMBINER PANEL TOTAL RATING OF ALL 40 .°83 it 2.2.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. 293 LIBBEY INDUSTRIAL PKWY, WITHIN SIGHT OF THE AC SERVICING DISCONNECT. HOWEVER.THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED UNIT 250,WEYMOUTH, 2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC 705.12(D)(2535C1. LINE MA 02189,USA ACCORDING TO NEC APPLICABLE CODES. 2.5.6 FEEDER TAP INTERCONECTION(LOAD SIDE)ACCORDING TO NEC 705.12 888578-6848 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR (D)(2)(1) ,O NON FUSIBLE USAGE WHEN APPROPRIATE. 2.5.7 SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12(A)WITH \ AC DISCONNECT www.summitsolarenergy.com 2.3.1 STRUCTURAL NOTES: SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.3.2 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED ACCORDING TO 2.5.8 BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS LOAD CUSTOMER DETAILS CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(DX5)I. DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A 2.6.1 DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, 2.6.2 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH ACCORDING TO RAIL MANUFACTURERS INSTRUCTIONS. IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO LINE O O = _ S 2.3.3 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS'SPECIFICATIONS. THE TERMINALS MARKED'LINE SIDE'(TYPICALLY THE UPPER TERMINALS). 2.6.3 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE FUSIBLE IN IF ROOF-PENETRATING TYPE,IT SHALL BE FLASHED&SEALED PER LOCAL _ Ni REQUIREMENTS. LOCKABLE,AND BE A VISIBLE-BREAK SWITCH. AC DISCONNECT (.9 W 0 Q o CD- Z 2.3.4 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND 2.6.4 BOTH POSITIVE AND NEGATIVE PV CONDUCTORS ARE UNGROUNDED. ,j SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED THEREFORE BOTH MUST OPEN WHERE A DISCONNECT IS REQUIRED, LOAD �e =LLIQ }] a Q CONTRACTOR. ACCORDING TO NEC 690.13. C 2.3.5 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 2.6.5 DC DISCONNECT INTEGRATED INTO ROOFTOP DC COMBINER OR INSTALLED LI- y r W SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. WITHIN 6 FT.ACCORDING TO NEC 690.15(C). W CO Q N lil F- 2.3.6 WHEN POSSIBLE.ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.6.6 RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY 0 Z 0 STAGGERED AMONGST THE ROOF FRAMING MEMBERS. OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS.CONTROLLED Z 2.4.1 GROUNDING NOTES: CONDUCTORS 630V AND 1240VA[NEC 690.12].LOCATION OF LABEL UTILITY/NET METER -> 0 = W 2.4.2 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND ACCORDING TO AHJ. BIDIRECTIONAL Q GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH 2.6.7 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8,690.9, N O. Z USE. AND 240. u1 U 2.4.3 AS IN CONVENTIONAL PV SYSTEMS.UNGROUNDED PV SYSTEMS REQUIRE AN 2.6.8 BOTH POSITIVE AND NEGATIVE P/CONDUCTORS ARE UNGROUNDED. ..1/OtapAl lb. O 0 EQUIPMENT GROUNDING CONDUCTOR.ALL METAL ELECTRICAL EQUIPMENT AND THEREFORE BOTH REQUIRE OVER-CURRENT PROTECTION.ACCORDING TO STRUCTURAL COMPONENTS BONDED TO GROUND,IN ACCORDANCE WITH 250.134 OR NEC 6 24 REQUIRED BY AHJ, YSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION M0/1.(SEE EXCEPTION IN NEC 6902) ,� UTILITY ELECTRIC PROJECT ID:MAEVE5.04-850 2 4 4 PV EQUIPMENT ONLY THE HDLLBE CONDUCTORSOUNARE UNGROUNDED.TO ACCORDING TO NEC 690.11 AND UL1699B. 2.4.4 P7 SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM ' GRID PREPARED ON:08/05/2021 NEC TABLE 250.122. 2.7.1 WIRING 8 CONDUIT NOTES: P, 2.4.5 METAL PARTS OF MODULE FRAMES.MODULE RACKING,AND ENCLOSURE 2.7.2 ALL CONDUIT AND WIRE WILL BE USTED AND APPROVED FOR THEIR PURPOSE. DRAWN BY: V.N. CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE CHECKED BY: S.T. W 2.4.6 EACH MODULE WILL BE GROUNDED USING WEEK GROUNDING CLIPS AS SHOWN IN REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. / M STAMPED BY: S.W. MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ.IF EEBS ARE 2.7.3 ALL CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT USED,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED 2.7.4 EXPOSED UNGROUNDED PV SOURCE AND OUTPUT CIRCUITS SHALL USE WIRE \ / UTILITY:EVERSOURCE GROUNDING LUG HOLES PER THE MANUFACTURERS'INSTALLATION LISTED AND IDENTIFIED AS PHOTOVOLTAIC(PV)WIRE[690.35(DI].PV V UTILINMET METER PE STAMP KITH Sit+ --umREQUIREMENTS. MODULES WIRE LEADS SHALL BE LISTED FOR USE WITH UNGROUNDED ,��(II���,// BIDIRECTIONAL - 2.4.7 THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT SYSTEMS.ACCORDING TO NEC 690.35(DX3). WITH METER MAIN THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO 2.7.5 PV WIRE BLACK WIRE MAY BE FIELD-MARKED WHITE[NEC 200.6(A56)]. ,- ANOTHER MODULE. 2.7.6 MODULE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY. '-.014 OF 2.4.8 GROUNDING AND BONDING CONDUCTORS,IF INSULATED.SHALL BE COLORED 2.7.7 ACCORDING TO NEC 200.7,UNGROUNDED SYSTEMS DC CONDUCTORS -"L'o' GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.1191 sc. V ' , WY L COLORED OR MARKED AS FOLLOWS: .. illj FIRE SETBACK •• pl FLASHING DC/DC POWER it, . I '` �:•:5G i H' DC POSITIVE-RED,OR OTHER COLOR EXCLUDING WHITE,GREY AND 0 ATTACHMENT OPTIMIZERS ,.\.9 SP, `y-- �,..% • GREEN GREY SOLAR MODULES _STRINGS EGC 8 GC � �N=„=4N�7 DC NEGATIVE-BLACK,OR OTHER COLOR EXCLUDING WHITE, . ON THE __ BONDED AND AND GREEN ROOF/GROUND _BLACK RAIL = GROUNDED 2.7.8 AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR LI-BLACK BACK FEED "NE RESIDENTIAL PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE -I _ BREAKER SMART/ TESLA PHASE C OR L3-BLUE,YELLOW,ORANGE',OR OTHER CONVENTION r I_I PRODUCTION BATTERY OPTION PAGE DESCRIPTION NEUTRAL-WHITE OR GREY .. -- O ELECTRIC 1 1 METER •IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE WIRE TAPS PV 2 TO BE MARKED ORANGE[NEC 110.151. L.. GEN RA PROJECT NOTES D• NOTE:THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN \ ^.� OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WTH ENOUGH DETAIL TO \ DEMONSTRATE COMPLIANCE WITH AU.APPLICABLE CODES AND REGULATIONS.THE w 777----/ ..s '/�//�\\ \` DOCUMENT RER INSTALLATION NOT TIE RELIED UPON I AS A SUINSTALLER SHALL FOR FOLLOWINGLLE ` ` Cl r.._. ] MANUFACTURER INSTALLATION MANUALS.INSTALLER SHALL INSTALL ALL EQUIPMENT IN ,\v\\ ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS.NOTHING IN THIS �� DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS. //\• SUMMIT /ill ENERGY 0EPC COMPANY: SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, C / 1 mitsolarene Oi �//.� wwwsummitsolarenergy.com /<\• e <1(1\ CUSTOMER DETAILS i 7 x gF- m N ,n U1- 2 0 Z o Z S. Q W j P \`\ LL N co uj r W S. W IY <R, w is S. 0 O gWg ``� ° I- d Q S. Cl) Z ,/r�9// o o `� s/OA*, O S, PROJECT ID:MAEVE5.04-850 S. O F 'L PREPARED ON:08/05/2021 c/, ` CAA DRAWN BY: V.N. CHECKED BY: S.T. S. I I�yiL '9� STAMPED BY: S.W. S. lPA_II, �C UTILITY:EVERSOURCE v9Q'79,QT?, N PE STAMP WITH SIGMA �r& \`. 1 ♦ 0 li /AI F 4--;,-g-'!'of , , , ,flic : .1* 4 cy 12%; '<l's to;9041, S 0 PLOT PLAN PAGE DESCRIPTION SCALE:1'0"=1'0" PV 3 PLOT PLAN NOTE 1:EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM Z2\_ WORKING CLEARANCES PER NEC 110.26. L� NOTE 2:CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. NOTE 3:CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL RELATED ' EQUIPMENT,CABLES,ADDITIONAL CONDUITS,BOXES, RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. SUMMIT NOTE 4:THE SYSTEM SHALL COMPLY WITH NEC ARTICLE 690,ALL ENERGY MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. NOTE 5:WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN — EPC COMPANY: INSIDE THE BUILDING,THEY SHALL BE CONTAINED IN METAL RACEWAYS,TYPE MC METALCLAD CABLE,OR METAL SUMMIT ENERGY GROUP ENCLOSURES FROM THE POINT OF PENETRATION INTO THE �I BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING I 293 LIBBEY INDUSTRIAL PKWY, MSrI MEANS,PER NEC 693.31(G) UNIT 250,WEYMOUTH, NOTE 6:ABOVE DIMNSSIONS ARE FOR THE RESPECTIVE ROOF PLANESO MA 02189,USA MEASURED BETWEEN THE ROOF RIDGE TO THE EVE AND RAKE TO RAKE 888578-8648 www.summitsolarenergy.com LEGENDS: _ p CUSTOMER DETAILS OUTILITY METER _ O 4 WI MAIN SERVICE PANEL oI c7i vi (ACDF AC DISCONNECT I �i --ARRAY 1 w- 0 i; I I #14,REC 360W i w %cn o i jFIRE CLEARANCE e rn b #14,SE P401 u is w El INVERTER TILT 32° w it Z o ui JB JUNCTION BOX I AnMUTH O O a- EJ REC 360W I I < a _STRINGS,MINIMUM 8 MODULES i ° $ ® Z AND MAX 5700W PER STRING o o ....- 50.30'- H• 1"MODULE CLEARANCE PROJECT ID:MAEVE5.04-850 PREPARED ON:08/05/2021 SM MA SMART METER DRAWN BY: V.N. SYSTEM INFORMATION CHECKED BY: S.T. STAMPED BY: S.W. DC SYSTEM SIZE 5.04 KW UTILITY:EVERSOURCE `i' -''. -3.42' AC SYSTEM SIZE 3.8 KW hEGTAMP WITH SIGNA ,11 REC TWIN PEAK MODULE SERIES BLACK 360TP4, in of I 360W #`„ .;. I d OPTIMIZER 8 SOLAREDGETECHNOLOGIES,P401, i!'i• �, INVERTERNo"�:' REC TWINPEAK 4 BLACK SE3800H-US o�\` c SERIES,REC365TP4,365W TOT TOTALARRAY265SO.FT. \\p:s EflG4,' NOTE:THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN ♦ • TOTAL NO.OF • OFA PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO \/ 14 DEMONSTRATE COMPUANCE WITH ALL APPLICABLE CODES AND REGULATIONS.THE MODULES DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING 0 SITE PLAN ARRAY 1 AZIMUTH 224° ACCORDANCEEWIINSTALLATION TH MANUFACTURERMANUALS. INSTALLER ALLATION MANHUALS.NOTHIINSTALL NG IN THIS IN /1\ PAGE DESCRIPTION SCALE:1'0"=1'0" ARRAY 1 PITCH 32° DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN PV 4 MANUFACTURER INSTALLATION MANUALS. UTILITY NAME EVERSOURCE SITE PLAN - ° ar i Jam._ (,,,,,A) SUMMIT ENERGY EPC COMPANY: SUMMIT ENERGY GROUP 293 LIBBEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, MA 02189,USA 888-578-6648 www.summitsolarenergy.com CUSTOMER DETAILS A } g FS N .•. • ----ARRAY 1 a? co o p #14, REC 360W LL o '� r a a a s #14, SE P401 CO it z o w g iv TILT 32° ° z W LEGENDS ® a a ra i a a Ld IRONRIDGE XR100 BLACK O -- ---�- I o 0 0 v IOJ IRONRIDGE FLASH FOOT 2 - - -- -T---T--T-- — PROJECT ID:MAEVE5.04-850 ■ I I PREPARED ON:08/05/2021 TT I I I I I DRAWN BY: V.N. DEAD LOAD CALCULATIONS - --48"MAX MOUNT SPACING I CHECKED BY: S.T. LOAD QTY. LBS. TOTAL LBS L2X6 RAFTERS @16"O.C. STAMPED BY: S.W. UTILITY:EVERSOURCE MODULES 14 45 830 OPTIMIZERS 14 1.70 24 PE STAMP WITHSICNA •=' LINEAR FEET OF RAIL(ft.) 100 0.4 40 _ FLASH FOOT 2 30 0.09 3 `.h 1 OF + SIMPLE GRIP-SQ 0 0.09 0 sa MID CLAMPS 24 0.09 2 �`vr.' END CLAMPS 8 0.09 1 0. ti GROUND WEEBS 4 0.09 0 \?\' ^, 9 Q, • MISC.HARDWARE 0 NOTE 1:DIMENSIONS IN RED INK MEASURES THE HORIZONTAL � �- Nti�1)io`N TOTAL ARRAY WEIGHT 700 DISTANCE BETWEEN RIDGE AND THE SIDE WALL •AREA NAME QTY. SOFT. TOTAL SQ.FT. NOTE 2:MOUNTS/ATTACHMENTS SHOULD BE INSTALLED AS PER \I/ - MODULES 14 19 288.00 ' MANUFACTURERS INSTRUCTIONS ATTACHMENT PLAN TOTAL ROOF AREA - - - NOTE 3:FLASHINGS ONCE INSTALLED SHOULD BE SEALED TO %OF ROOF AREA COVERED BY SOLAR PV(-/-) - WATER TIGHT /'\ SCALE:1'0"=1'0" PAGE DESCRIPTION POINT LOAD(TOTAL ARRAY WT./ATTACHMENTS),Lbs/Sq.ft. 23 NOTE 4:IF THE ROOF IS DETERMINED TO BE WEEK AT THE PV 5 - INSTALL,STOP THE WORK AND NOTIFY THE PROJECT ENGINEER DIST.LOAD(TOTAL ARRAY WT./TOTAL SO.FT.),Lbs/Sq.ft. 2.63 ATTACHMENT DIAGRAM 1 (----.... IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE IRONRIDGE UNIVERSAL IRONRIDGE UNIVERSAL FASTENING OBJECT / PV MODULE FRAME PV MODULE FRAME FASTENING OBJECT ► Cir IRONRIDGE UNIVERSAL PV MODULEFRAMEAdip� PV MODULE FRAME ,' IRONRIDGEUNRSALSUMMIT � FASTENING OBJECT IRONRIDGE RAIL 1 _ FASTENING OBJECT ENERGY IRONRIDGE STOPPER r IRONRIDGE RAIL)l� SLEEVE WOO , _ EPC COMPANY: _ r- I SUMMIT ENERGY GROUP 293 UBBEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, MA 02189,USA 888-578-6648 www.summitsolarenergy.com CUSTOMER DETAILS IRONRIDGE FLASHING—\ = S D h 2< o 2 IRONRIDGE RAIL—N N �� o >-co v- g 110 wrx a, w I- w CL � 0 a 2 SHINGLE _ o 0 100 PROJECT ID:MAEVE5.04-850 \ PREPARED ON:08/05/2021 VARIES \ DRAWN BY: V.N. 11 ��\ CHECKED BY: S.T. � t STAMPED BY: S.W. tt ��\ UTILITY:EVERSOURCE \t \ \ ‘ —44 STAMP MMTN SI ATURE r 7 \ 0 7 ' �.`S.OP; SATL fi�'����4' ": a , PAGE DESCRIPTION L J PV 6 ATTACHMENT DETAILS NOTE 1:ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 8 690 NOTE 8:INSTALLATION SHOULD BE NEC 2020 CODE COMPLIANT \, NOTE 2:PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED NOTE 9:EQUIPMENT SHOULD BE SERVICE RATED j� \ GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION.ALL OTHER EXPOSED METAL PARTS SHALL BE NOTE 10:WIRE SIZING SHOULD BE AS PER 690.31(NEC 2020) //V \\ 1 GROUNDED USING UL-USTED LAY-IN LUGS. NOTE 11:NEUTRAL AND GROUND SHOULD BE BONDED ONLY ONCE NOTE 3:GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE NOTE 12:A SEPARATE GROUND ROD MUST BE INSTALLED FOR SOLAR PV AS PER l-----_--� NOTE 4:AC SYSTEM GROUNDING ELECTRODE CONDUCTOR(GEC)SHALL BE A MINIMUM SIZE#8AWG WHEN 250.52 A(1)THROUGH A(8)TO MEET NEC 2020 REQUIREMENTS. THE ADDITIONAL INSULATED,#6AWG IF BARE WIRE. GROUND ROD IS NOT REQUIRED AS PER 250.53 A(2)EXCEPTION WHICH READS IF A -� NOTE 5:EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45,AND BE A SINGLE ROD,PIPE,OR PLATE GROUND ELECTRODE HAS A RESISTANCE TO EARTH S U ^^ T MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG v SHALL BE USED WHEN EXPOSED TO DAMAGE OF 25 OHMS OR LESS. , NOTE 6:GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN,OR MARKED ENERGY GREEN IF#4AWG OR LARGER NOTE 7:DISCONNECTING MEANS SHOULD BE ACESSIBLE WTHIN 10'OF THE SUPPLY SIDE CONNECTION,IT CAN BE A FUSED DISCONNECT OR A MANUALLY OPERATED CIRCUIT BREAKER EPC COMPANY.' WIRE SIZING SCHEDULE SUMMIT ENERGY GROUP WIRE ID GUAGE DESCRIPTION A 293 LIBBEY INDUSTRIAL PKWY, 8 AWG THWN-2 COPPER EGC WIRE FROM JUNCTION BOX-GEC.#6 BARE CU WIRE ON THE ROOF BETWEEN THE RAILS UNIT 250,WEYMOUTH, B 10 AWG PV WIRE COPPER MODULES AND DC OPTIMIZER WIRE TO JUNCTION BOX MA 02189,USA C 10 AWG THWN-2 COPPER JUNCTION BOX TO INVERTER 888-578-6648 D,E 10 AWG THWN-2 COPPER LINE AND NEUTRAL WIRES FROM INVERTER-SMART METER-AC DISCONNECT - `W"W.summitsolarenergy.com F 10 AWG THWN-2 COPPER AC DISCONNECT-BACK FEED BREAKER-MAIN SERVICE PANEL-GRID _ CUSTOMER DETAILS SYSTEM SUMMARY COMMUNICATION DIAGRAM 1 STRING 1 STRING 2 STRING 3 SINGLE INVERTER MULTIPLE INVERTERS 5g OPTIMIZER MAXIMUM OUTPUT CURRENT 15A 15A - OPTIMIZERS IN SERIES 14 a Z �w O vi NOMINAL STRING VOLTAGE 480Vdc wil —� ` �}� ligIrg v I Q o zDC OPERATING CURRENT 11.32A - !EY Eta" ►ilThe;;�1 =o - w TOTAL ARRAY STC POWER 5,040 WdC i.:1 S u e C ISS' Eta" CLfLrL` .�. LL y n TOTAL AC SYSTEM SIZE 3800 Wac I DaSVc0*N DAISxawN 0110) w ce Q N w I- COMMUNICATION SE 5 YR-GSM CELL KIT giter. SOLAREDGE TAL E I 2 G o 0 INVERTER MAX INPUT DC/MAX OUTPUT AC 10.5Adc/16Aac dak NOW F a a INVERTER MAX INPUT DC POWER 5890Wdc Z ALLOWABLE MIN/MAX STRING POWER MIN 8 MODULES IN SERIES/MAX 5700W IN A STRING 0 BIDIRECTIONAL 'i 0 60A,240V AC NON FUSIBLE UTILITY METER DISCONNECT 120/240V PROJECT ID:MAEVE5.04-850 LOCABLE,NEMA 3R, METER#2370039GRID MA SMART UL USTED © PREPARED ON:08/05/2021 METER SOCKET. GANG OPERATED, DRAWN BY: V.N. FORM 2S,200A OPEN BLADE CHECKED BY: S.T. 120/240V READILY ACCESSIBLE SOLAREDGE TECHNOLOGIES NEMA 3R 3'WTHIN UTIUTY METER STAMPED BY: S.W. SE3800H-US,NEMA 3R,UL LISTED, UTILITY:EVERSOURCE INTEGRATED GFDI AND DC DISCONNECT. I-Drcn -- EQUIPPED WITH RAPID SHUT DOWN I _t PE STAMP WITH SIGNATURE SOLAR EDGE E F N P401 OPTIMIZER ti ueE EINE LOAD SIDE 14-REC 360W 1 OPTIMIZER PER MODULE �y..y f--Cr INTERCONNECTION zSn f--MAIN BONDING JUMBER ONO \ AS PER 705.12(B) JUNCTION BOX Ir. o O b z LI D AD 100A MAIN SERVICE PANEL. 1 2 3 13 14 BooV,UL LISTED A -1- EF, 100A MAIN BREAKER LA A 120240V __ __ ----.^-13--I—i.—--— 20A BACK FEED BREAKER. MAX BREAKER SIZE CALC. -- "� (100A X 1.2)=120A-100A _20,4 SQUARED COMPANY PAGE DESCRIPTION B C D PV 7 ELECTRIC DIAGRAM 1 BILL OF MATERIALS CATEGORY MAKE&MODEL QTY DESCRIPTION0 MODULE REC TWIN PEAK SERIES BLACK 360TP4,360W 14 REC 360W,MONO-CRYSTALLINE BOB INVERTER SOLAREDGE TECHNOLOGIES SE3800H-US 1 HD WAVE SETAPP INVERTER SE3800H-US W/RGM&CONSUMPTIUON METER POWER OPTIMIZERS SOLAR EDGE P401 14 SOLAR EDGE 401W DC OPTIMIZERS(ONLY WITH SE INVERTERS) EM WITH 5 YRS FOR ESIDENTIAL SETAPP COMMUNICATION CT CLAMPS ELL KIT SOLAREDGE CELL-B-R05-US-S-S2 CELL SOLAR EDGE SEACT0750-200NA 20 200 CT 2 MOD SOLAR EDGE Ts ONLY FOR UNNOVA PROJECTS ERS SUMMIT AC COMBINER PANEL 100A COMBINER EATON OR EQUI. - 60A,240V 3W 1PH AC COMBINER PANEL,NEMA 3R AC FUSIBLE DISCONNECT SQUARE D DU222NRB OR EQUIV. 60A,OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2020 EPC COMPANY: AC NON FUSIBLE DISCONNECT SQUARE D DU222RB OR EQUIV. 1 60A,OVER CURRENT PROTECTION DEVICE AS LISTED IN NEC 2020 SUMMIT ENERGY GROUP JUNCTION BOX EQUIVALENT JUNCTION BOX 1 _ DC COMBINER ENCLOSURE,600VDC,120A,UL1741,NEMA 3R,CSA C22.2 FUSES BUSS FUSETRON OR EQUI. - 20A,240VAC FUSES 293 LIMEY INDUSTRIAL PKWY, UNIT 250,WEYMOUTH, BACK FEED BREAKER/BREAKERCAIV MAIN EATON OR EQUI. 1 20A,2P MODE OF INTERCONNECTION,MAX RATED VOLTAGE:24OVAC MA 02189,USA MA SMART METER/GENERATION METER SQUARE D OVERHEAD OR UNDERGROUND METER SOCKET 1 200A,120/240V,NEMA 3R SMART METER SOCKET 888578-6648 www.summitsolarenergy.com CONDUIT RUN EMT TBD ONSITE i"OR 1"EMT CONDUIT RUN SHOULD BE INSTALLED AS PER THE CODE CUSTOMER DETAILS TRENCH RUN RIGID PVC SCHEDULE 80 TBD ONSITE TRENCH SHOULD BE AT LEAST 18"DEEP.USE WARNING TAPE DURING BACKFILL E zzi “i COMPONENT SPECIFICATIONS Z F cn m a=o >_ g wW ac r w MODULES UJ cc o 0 o g MAKE&MODEL QTY. PMAX PTC LSC VOC VMP TEMP.COEFF. FUSE i= _ OF VOC RATING r o to Z REC TWINPEAK 4 BLACK 14 360W 272W 11.26A 40.6V 33.9V -0.26%/°C 25A v p SERIES PROJECT ID:MAEVE5.04-850 POWER OPTIMIZERS PREPARED ON:08/05/2021 RATED INPUT MAXIMUM MAXIMUM DC MAXIMUM DC WEIGHTED DRAWN BY: V.N. MAKE&MODEL POWER QTY. OUTPUT INPUT VOLTAGE EFFICIENCY CHECKED BY: S.T. CURRENT CURRENT STAMPED BY: S.W. SOLAR EDGE P401 401W 14 15A 11.75A 60V 98.8% UTILITY:EVERSOURCE PE STAMP WITH SIGNATURE INVERTER MAX CEC MAKE& OTy AC GROUND RATED OUTPUT MAX INPUT MAX INPUT WEIGHTED MODEL VOLTAGE POWER CURRENT CURRENT VOLTAGE EFFICIENCY SOLAR EDGE 1 240V FLOATING 3800W 16A 10.5A 480V 99% 3800 H-US RAIL AND MOUNTS RAIL RAIL MOUNTS TYPE LENGTH #OF RAILS #OF #OF MID #OF END #OF MODEL MOUNTS CLAMPS CLAMPS GLUGS PAGE DESCRIPTION IRONRIDGE XR100 FLASH ALL 14'EACH 7 30 24 8 4 BLACK FOOT 2 BLACK PV 8 BILL OF MATERIALS