HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: AM (vi LOT // Date of Subdivision Approval T7) S 7 S�- gStreet /t � ;z� ( d / Zone of Contribution: In Out Village % !rl�G2 '�// Commercial Residential -" Owner: /#4 _, /,e' f ,/,/ll' 7 /'s-"" Installer Builder: Engineer �/ � � "M k..2 Z S S-/O�G � N/A YES NO 1. Required number of copies received. 2. Date of soils exam and percolation test not older than 2 years. 3. 4 feet of naturally occurring pervious material, above water table(new construction) ►l 4. Foundation 2 feet above high point of fronting road for new construction. 5. Water availability letter from Water Department for new construction. ►/ 6. Benchmark indicated and shown- NGVD if near wetlands. ✓ 7. Building sewer does not exit center of house. 8. Septic tank a minimum of 10 feet from house and deck. ,/ 9. Leaching a minimum of 20 feet from house and 10 feet_from deck. ,....---- 10. Leaching a minimum of 100 feet from wetlands. �--- 11. Leaching a minimum of 150 feet from drinking wells/25 feet from irrigation wells. �" 12, System meets all other setback requirements. 13. Uses adjustment for maximum high groundwater. ./ 14. Leaching 4 -5 feet above adjusted water table or bottom of test pit. i/ 15. System not in top or subsoil or 5 foot removal. t l 16. Proposed contours are suitable. t/' 17. System meets slope requirements - min. 1/8"L 1/4" preferred. t_/. 18. System meets breakout requirements- peastone elevation carried out 15 feet minimum. 1../- 19. Specified tee sizes are proper. gas baffle on outlet tee. 20. Sewage flow under 10.000 gpd for parcel. ✓ 21. No garbage disposal. L/ 22. System adequately sized for its intended use, ►l 23. Minimum 6" stone or mechanically compacted below the tank and d-box. 1 24. Manhole covers within 6" of grade - septic tank and pump chamber. 1 25. Electrical permit for pump chamber. ,/ 26. Pump system - 2" line, weep hole, check valve_sanitary in d-box, alarm on separate circuit. ,. 27. Septic tank and pump chamber to be Factory waterproofed. f 28. Vent provided if leaching below 3 feet or under driveway or parking. ✓ 29. Engineer to inspect and certify : A. clay removal c./ b. wall construction schedule c. commercial system 30. Engineer and Land Surveyor stamp and signature, 1_,---'-- 31. H2O loading when system subject to vehicular traffic. ,/ 32. Title V application and fee signed by a licensed installer. t 33. Foundation footing 2 feet above adjusted water table. 34. Lot subdivided prior to July 31,_1986 - Nitrate Loading, 35. Subdivided prior io April 7, 1989 - Phosphorus Zone 300'. Plan reviewed by: 0