HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. 37 Lot /ig Zone of Contribution: In Ou Acreage
Commercial: S- Residential:
Street: y
Village: (,,e/ ` ze,i-A4 U2 Floor Plan: # Bedrooms:
Owner: 27k its' 2G ✓ Q{G*- Installer: ✓"
Address: l/ Phone:
Phone:
Builder: Engineer: CK-
Address: / Phone: 7 - i
Phone:
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years .....---
3. 4-5 ft of naturally occurring pervious material,above water table
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5. Water line 10 ft from septic components Var.: L
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.: ‘/,
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 4/
9. Leaching minimum 100 ft from wetlands Var.: t7.-
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/ /
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: ✓
13. Uses adjustment for maximum high groundwater Var.: �JVtu4< ✓
14. Leaching set 4-5 ft above adj. water or botto hole` Val./YU ✓
15. System not in top or subsoil(A,B horizons or 5' removal ✓/
16. Proposed contours are suitable 1f
17. System meets slope requirements-min. 1/8", '/"preferred
18. System meets breakout requirements PVC liner: Wall: L✓
• 19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal :,b,
22. System adequately sized for its intended use ',,/
23.Minimum 6"stone or compacted below tank and dbox ✓
24.Manhole covers within 6"of grade, pump chamber cover to grade ly
25. Inspection port on plastic chambers/leach field ✓/
26. Electrical permit for pump chamber/Separate meter for duplexes ✓/
27. Pump system-2" line,weep hole,check valve,tee in dbox, pump size ✓�
28.Septic tank/pump chamber to be factory waterproofed ✓f
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber V
31. Engineer to inspect and certify soils: wall: commercial: / /
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓/
33. H-20 loading is subject to vehicular traffic, groundwater \.
34. Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd t�
37.Check area lots for groundwater/Label groundwater in Assessor's Map V
Plan reviewed by: ( 6/03/03
. . ,.
..
I /57A
ii - )(
� 7
9