Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 37 Lot /ig Zone of Contribution: In Ou Acreage Commercial: S- Residential: Street: y Village: (,,e/ ` ze,i-A4 U2 Floor Plan: # Bedrooms: Owner: 27k its' 2G ✓ Q{G*- Installer: ✓" Address: l/ Phone: Phone: Builder: Engineer: CK- Address: / Phone: 7 - i Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years .....--- 3. 4-5 ft of naturally occurring pervious material,above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: L 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: ‘/, 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 4/ 9. Leaching minimum 100 ft from wetlands Var.: t7.- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t/ / 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: ✓ 13. Uses adjustment for maximum high groundwater Var.: �JVtu4< ✓ 14. Leaching set 4-5 ft above adj. water or botto hole` Val./YU ✓ 15. System not in top or subsoil(A,B horizons or 5' removal ✓/ 16. Proposed contours are suitable 1f 17. System meets slope requirements-min. 1/8", '/"preferred 18. System meets breakout requirements PVC liner: Wall: L✓ • 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal :,b, 22. System adequately sized for its intended use ',,/ 23.Minimum 6"stone or compacted below tank and dbox ✓ 24.Manhole covers within 6"of grade, pump chamber cover to grade ly 25. Inspection port on plastic chambers/leach field ✓/ 26. Electrical permit for pump chamber/Separate meter for duplexes ✓/ 27. Pump system-2" line,weep hole,check valve,tee in dbox, pump size ✓� 28.Septic tank/pump chamber to be factory waterproofed ✓f 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber V 31. Engineer to inspect and certify soils: wall: commercial: / / 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓/ 33. H-20 loading is subject to vehicular traffic, groundwater \. 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd t� 37.Check area lots for groundwater/Label groundwater in Assessor's Map V Plan reviewed by: ( 6/03/03 . . ,. .. I /57A ii - )( � 7 9