Loading...
HomeMy WebLinkAboutEngineer PlanSEE TRENCH DETAIL USE 4' STONE OVER PIPE 36" MAX — 12' MIN. COVER 4' MIN. LOAM & SEED DRILL PERFORATIONS _91111fiflaoU ELBOW• • mg %,OWA w, k- 6y, IN ON NOW Fm �i �i �i �� �i �� �i �� �� �i �� �: �� �: is �• �i �• �i � � sir ♦� •sr •� '� •� •� iir ^ir sir •� ..� •� '� •ir �� �� •sr •m WzV1w AP OP AV a ^� �: �i �i �� �i �i 1i s•� �i �i �: �� ii �i �� �i 1• �• �1 • �� 'ir ^� •� ►� '� '� ^� �� •ir � ^� �� •it ^� �� • t: •� •� sir �� '�•i�'�•�'�. .�. .�. .�. i_. ice. i_. ._. .�. ice. .�-`—'�'�'�'��.•�������.•�. .�. ._. .�. .�. .�. .�. .�. .�. ,�. .�. .�������.•�•��•�.•�.' 11mmmolm 0-MIR: AM I lb" [ea I a 4*bl NO SCALE 6" THICK 18" DIA. HEAVY DUTY MANHOLE COVER CONCRETE PAD BROUGHT TO FINISH GRADE WEARING COURSE BINDER COURSE 1 /8" TO 1 /2" •. _ .. PAVEMENT BASE WASHED STONE = .-~ — : - • . - 18" 3/4" TO 1-1 /2" ° DOUBLE WASHED — v STONE (NO FINES) - - SCH. 40 PVC PIPE FROM SAND TO ABOVE PEASTONE (NO STONE IN PIPE) TO BE USED AS A VISUAL INSPECTION PORT SAW CUT PIPE 3" OC W/2" LONG SLOTS ON ONE SIDE ONLY INSPECTION PORT DETAIL UNDISTURBED EARTH PLAN - TEE AND PLUG n L OR Y PLAN - HORIZ. AND VERT. BEND . o . tBED EARTH TYPICAL SECTION TEES. BENDS AND PLUGS SIZE OF BRANCH J K L I M N 0 3" THRU 8" 10' 10" 1 V-0' 2'-0" 90 & 45 BENDS D 4"T08" 0"TO18 24' X 1'-8" 3'-4" 3'-6 Y V-2" V-8" 2'-4 TEES AND PLUGS BENDS NOTES: 1. PROVIDE CONCRETE THRUST BLOCKS AT ALL BENDS, DEAD ENDS, & TEES UNLESS OTHERWISE DIRECTED. CONCRETE FOR ALL THRUST BLOCKS TO BE PLACED AGAINST FIRM, UNDISTURBED SOIL. PROVIDE APPROVED ANCHOR HARNESS RODS & SOCKET CLAMPS AS SPECIFIED & IN ACCORDANCE WITH PIPE MANUFACTURERS RECOMMENDATIONS WHERE SOIL HAS BEEN DISTURBED OR THRUST BLOCKS CANNOT BE USED, AS DIRECTED BY THE ARCHITECT. 2. ALL SOCKET CLAMP METAL SHALL BE COATED WITH BLACK ASPHALTUM OR OTHER WATER DEPARTMENT APPROVED COATINGS. 3. CONCRETE THRUST BLOCKS POURED BEHIND 3-WAY TEE & HYDRANT SHOE TO BE USED WITH SOCKET CLAMPS. 4. NO CONCRETE SHALL COVER PIPE JOINTS, FITTING JOINTS, BOLTS OR HYDRANT DRAINS. THRUST BLOCK DETAILS FINISHED GRADE 6" LOAM & SEEDED IN GRASS SEWER & FORCE MAIN AREAS. IN ROADWAY/WALKWAYS AREAS DEPTH AND MATERIALS TRENCH SECTION AS REQUIRED TO MATCH EXISTING NOT TO SCALE PAVEMENT/ AND SUBGRADE. ELECTRIC, AND PUMP CONTROL WIRE CONDUIT (P.V.C.) (WHEN REQUIRED) v-EXISTING GROUND PAVEME 8" GRA 3-MAX. SCREENED GRAVEL PLACED TO 12" OVER PIPE + N i i s rp N EARTH N 0 MUSHROOM VENT WITH INSECT SCREENS AND CHARCOAL FILTER " PVC VENT STACK SUPPORT AS REQUIRED) 2" LAYER 1 `8"-3/8" WASHED STONE 6" TOPSOIL 2" PVC LATERAL 2 CU.FT. CEMENT CONCRETE 4" PVC 90' ELBOW 4 ' MIN COVER ON FORCE MAIN - SEWER OR FORCE MAIN PIPE (P.V.C.) \-4" PVC HEADER 0%0 00 CAP END OF LATERAL (TYP.) / OR CLEANOUT 0 00 3/4"-1 1 /2" WASHED CRUSHED STONE 4" PERF. PVC VENT (INVERT VENT PIPE TO MATCH INVERT LATERAL) TYPICAL VENT SYSTEM OVER LEACHING FIELDS CAP 6'-0" (T1PA LEACHING FIELD F31x3'xr TEE 3'x3"x2TEE 3'x3'x2' TEE 3'x3"x2" TE 3' PVC 3' PVC 3' 3' 3" PVC . . SET LEVEL SET LEVEL LEACHING FIELD . . . 3' PVC DOSING CHAMBER INFLOW 2'x2"x2' TEE—\ NOTE: ALL PFWG TO BE SOLVENT WELDED SCHEDULE 40 PVC LATERAL 3"x3'x2e* TEE MANIFOLD CROSS-SECTION 3" MANIFOLD PRESSURE DOSE HEADER MANIFOLD NO SCALE 36" MAX .COVER FINISHED GRADE NOTE: PERFORATIONS TO BE DRILLED SMOOTH AND PIPES TO BE BRUSHED TO PREVENT CLOGGING. AND SET AT 5 & 7 O'CLOCK IN AN ALTERNATING PATTERN. CAP/ C.O. SEE DETAIL DISTAL PERFORATION IN CAP ON SHEET 3 NEAR CROWN OF PIPE q p I I • e • O • • • + a q0 % q0�c 0% O • I1 • O + O Sq• ' O • O q• A O • • o +ti :'► ate° 4°►t bb 8"" EFFECTIVE e • • • • • • e •+ •+ • e • •+ s •+ • • •+pjap� • • DEPTH LEVEL BOTTOM 72' (36' EITHER SIDE OF MANIFOLD) PVC MANIFOLD - SEE DETAIL PROFILE 36" MAX. - 12" MIN. COVER 2" SCHL 80 PVC (SEE MANIFOLD/AJIL FOR PERFORATIONS 4" MIN. LOAM & SEED 2% MNSH GRADE /OR PAVE TO MATCH EXISITNG PAVEMENT 34 MAXI" 13' MIN • • : - J�1 t 2" MIN. OF 1 /8" TO 1 /2" 6• ORIFICE DOUBLE WASHED STONE • . + '� +4 . • �� SHIELD T� TO DOUBLE WASHED ED STONETONE ( (NO FINES) CROSS-SECTION LEACHING TRENCH DETAIL: NOT TO SCALE 22,000 GALLON SEPTIC TANK (TUNNEL TANK): BUOYANCE FORCE _ (3.04') X 62.4 Ib/cf X 44.33 x 11.0' = 108,123 LBS WEIGHT OF TANK = 158,600 LBS WEIGHT OF SOIL = (1' X 44.33 x 11.0 ') X 85 Ib/cf = 41,448 LBS 158,600 LBS + 41,448 LBS = 200,048 LBS > 108,123 LBS NOTES: 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK TO WITHSTAND H-20 LOADING 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. 12"x24" CONCRETE FOOTING W/ 4- { 4 - 24" DIA C.I. HEAVY DUTY MANHOLE COVERS BROUGHT TO FINISH GRADE TEE TO BE UNDERF 12" MIN. M.H. OPENING -1 COVER lolv~ ,ov RAISE M.H W� \ SEWER BRICK & MORTAR NORMAL WATER LEVEL INV. IN 12.43 3" I e INLET TEE 7'-8" e ADJ. GW. 7.8 z W-s• MIN LIQUID LEVEL # _ N I BOTTOM TANK - ee. a A: ; 6.:-�_: e�-• -_ : •. -e•.eo.. EL 4.76 5. INLET AND OUTLET TEES TO BE CAST IRON, SCHED. 40 PVC OR CAST -IN -PLACE CONCRETE. TEES TO BE CENTERED UNDER MANHOLE COVER. 6. TANK TO BE MADE WATERTIGHT AT SITE. 7. TWO 12 D "x24 W FOOTINGS AREA TO BE SET UNDER TANK. 8. ANY WATER IN BOTTOM OF HOLE TO BE PUMPED DURING INSTALLATION OF TANKS. PLAN VIEW 24" DI . 24" DIA. u�awo �c 30' I'-0" 8' TOP 12 30" 8'-op" 9 s...,.,... . I '- 4" j 011TitOL OUTLET NJ) LI I i,000-dwL-O.8 I I OUTLET IM � = (GAS CONTROL) e- =: a e: - eel:: '.e 8.: ;tee c',:: a :.: : - ..� .: `: -;tee: 6"30T. 6" MIN. 3/4" TO �-ALL. .! /ilh�'.1�� /itC�1/�C./.Il�1lA�ilC��R`i'�N'/r1lC����C�►.�lC��/�C�/'�C� 1 1/2" STONE BOTTOM ON LEVEL STABLE BASE CROSS-SECTION VIEW 22,000 GALLONS PRECAST SEPTIC TANK N.T.S. REVISIONS NO. DATE DESCRIPTION 1. 2/2/04 BOH. EDITS 2. 12/9/04 G. WATER ADJ. p S CIVL No.32112 A, AL �t- t•- v y FSC GROUP 557 Main "4t7eett, (RT. 28) Unit 6 W. Yarmouth h Massachusetts ®2573 508 778 99 � 9 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM REPAIR "CAPE COD SUPER BUFFET" 228 ROUTE 28 WEST YARMOUTH M ASSACH U SETTS PREPARED FOR: Mr. ZHANG ZI QIAN CAPE COD SUPER BUFFER, INC. 228 ROUTE 28 WEST YARMOUTH MA 02673 (508) 775-8110 DATE: JANUARY 27, 2004 COMP. DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 8608SEP1.DWG DWG NO. 5490-02 SHEET 2 OF 3 JOB NO. 4-8608.00 BITUMINOUS CONCRETE - 1 " TOP COURSE BITUMINOUS CONCRETE - 2" BINDER COURSE 12" COMPACTED GRAVEL BORROW BASE TOP JOINT TO BE SEALED WITH AN EMULSION AND SAND MIX EXIST. BITUMINOUS EXIST. GRAVEL BASE CUT EXISTING BITUMINOUS PAVEMENT IN A NEAT LINE USING JACKHAMMER OR SAW COMPACTED SUBGRADE CUT METHOD. CUT TO PASS THROUGH ENTIRE DEPTH OF EXISTING PAVEMENT • APPLY TACK COAT OF RS-1 EMULSION TO VERTICAL FACE OF EXISTING PAVEMENT PRIOR TO THE PLACEMENT OF THE NEW BITUMINOUS BITUMINOUS CONCRETE PAVEMENT SECTION TOP COURSE - BINDER COURSE EXIST. GRADE I1 BIT CONIC. BERM COMPACTED SUBGRADE CAPE COD BERM 6" WALLS (TYP.) I 6" SEWER 21 FROM SEPTIC TANK LOCATE TEE UlIBER MANHOLE 0 0 PRECAST PUMP CHAMBER b 'o, DUPLEX AL70MIM GOULDS SUBMERSWE PUMPS MODEL NO. 1GD11CIDA (2 H.P.) DUPLEX DOSING CHAMBER PIPING DETAIL DOSING CALCULATIONS: 3" 90' BENDS DESIGN FLOW TO CHAMBER - 7000 GPD REQUIRED EMERGENCY STORAGE = 7000 GALLONS EMERGENCY STORAGE PROVIDED = 7000 GALLONS NUMBER OF DOSING CYCLES = 4 TIMES PER DAY 1eH HANDLH'.S TIMES TWO SETS = 8 DOSES PER DAY STMMM SMIL VOLUME PER DOSE = 875 GALLONS 3" 90' BENDS DUPUN SURE "a srsim DEPTH PER DOSE - 9 INCHES 9' x 16' x 0.8 ' x 7.48 gal/cf = 861 GAL/DOSE JUNCTIO�f / DESIGN TDH = 15.5 FEET BOX DESIGN GPM = 105 GPM 3" GAl E ,.. 10" 2" PVC CONDUIT 2" TO 3" TO CONTROLS BASED ON PRESSURE DISTRIBUTION CUDANCE DOCUMENT ' FROM THE MASSACHUSETTS DEPT. OF ENVIRONMENTAL PROTECTION • 3" PVC 3/16" PERFORATIONS FOR 2" PVC PIPE DISCHAGE PIPE PERFORATION FLOW - 0.65 GPM 7 PERF'S PER PIPE x 0.65 GPM = 6.4 GPM PER LATERAL ' 22 LATERALS PER MANIFOLD x 4.59 GPM = 105 GPM •' 11*-5" ELEVATION DIFFERENCE FROM CHAMBER TO MANIFOLD = 9.5 NETWORK FRICTION LOSSES = 3.' TDH -9.5'+6 -15.5' 3 MERCURY USE GOULDS MODEL WS07BF 0.7HP 230 V 12.3 AMP 1 PHASE DIA PUMPS 110 GPM O 16 FT TDH FLOAT LEVEL CONTROLS NO SCALE 10' WADE x 17' LONG x 12'-11" DEEP 3r •HEAVY DUTY CAST PON ALUMI M 4r x 5e AOCESS DOOR FRAME & COVER H-20 L0AONG\0O SZ DOORS BROUGHT TO FWW GRADE BROUGHT TO FINISH GAM FINISH GRADE a INLET •_ TEE 10 T ADJ. GW. 7.8 12" MIN.\36" MAX. COVER :. - . 15" WEEP HOLE EMERGENCY STORAGE 6'-6" SEWER CLEAN OU T: NOT TO SCALE PAVEMENT MT. CONC a" MIN GRAVEL THREADED WATER TIGHT CAP LsBARON CAST WM LAO910 7H-20 RATED VALVE BOX. TO GRADE AT ONE END. POURED CONCRETE COLLAR (3,000 PSI) ALL AROUND 2" SCH40 PVC CONTINUOUS RADIUS ELBOW HA W i GRASS BUOYANCE FORCE _ (6.8') X 62.4 Ib/cf X 17' X 10' = 72,134LBS WEIGHT OF TANK = 83,000 LBS WEIGHT OF SOIL = (1' X 17' X 10') X 85 Ib/cf = 14,450 LBS 83,000 LBS + 14,450 LBS = 89,950 LBS > 72,134 LBS INSPEC11ON SCHEDULE 1. ENGINEER SHALL INSPECT WHEN THE REQUIRED EXCAVATION IS COMPLETE. 2. ENGINEER SHALL INSPECT 22,000 GALLON TANK FOOTING 3. ENGINEER SHALL INSPECT WHEN CLEAN FILL WITH A PERCOLATION RATE OF LESS THAN TWO (2) MINUTES PER INCH HAS BEEN PROPERLY DEPOSITED. 4. ENGINEER SHALL INSPECT WHEN THE COMPONENTS OF THE SEPTIC SYSTEM AND THE PUMP MECHANISMS HAVE BEEN INSTALLED. GREASE TRAP DETAIL: NOT TO SCALE 4,000 GALLON 7'-0" 4*0 INLET 17'-0" ---I - 6'-0" D - ` \3 - 24" DIAMETERICOVERS PLAN VIEW 2" MIN. 13 - 24" MANHOLE COVERS WITH FRAME94w, BOTTOM TANK EL 7.9Avj1 t = '• ADJ. GW. 7.8 6" CRUSHED STONE ON COMPACTED, LEVEL AND TRUE TO GRADE STABLE BASE -� • PUMP ON 4" '. 9w PUMP OFF 10" BOTTOM TANK EL 1.0 F 8" BOTTOM BOTTOM ELEV. - 1.67 DUPLEX PUMP CHAMBER NO SCALE (11,000 GALLON SEPTIC TANK) USE OUTLET HOLE AS INLET PUMP CHAMBER NOTES: 1. PUMP CHAMBERS TO WITHSTAND H-20 LOADING. 2. RECOMMENDED MANUFACTURER - SHOREY OR APPROVED EQUAL 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. RAISE MANHOLES TO FINISH GRADE WITH SEWER BRICK AND MORTAR. FULL OUTER MORTAR PARGE TO PROVIDE WATERTIGHT SEAL. 5. POWER CABLES TO BE PLACED IN CONDUIT IN ACCORDANCE WITH LOCAL BUILDING AND WIRE CODES. CONNECTIONS SET IN ADJACENT D-BOX 6. ALARM & CONTROL PANEL TO BE LOCATED AS DIRECTED BY THE OWNER. 7. ALARMS AND CONTROLS ARE TO BE ON SEPARATE CIRCUITS. 3" 90' BENDS 3" GAT DUPLEX nt_i v_n,vn i "qv vvvwa SUBMERSIBLE SEWAGE PUMPS PLAN co OUTLET 6'-9" 7'-9" 0 CROSS-SECTION NOTES: 1.) TANK SHALL BE WATERTIGHT PRECAST CONCRETE. 2.) GREASE TRAP SHALL WITHSTAND H-20 LOADING. 3.) ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4.) INLET AND OUTLET TEES TO BE CAST IRON OR SCHED. 40 PVC AND TEES TO BE ACCESSIBLE UNDER MANHOLE COVER. 5.) MANHOLES SHALL BE BROUGHT TO FINISHED GRADE WITH HEAVY DUTY 24" DIAMETER CAST IRON FRAME AND COVERS 6.) GREASE TRAP SHALL MEET ALL REQUIREMENTS OF 310 CMR 15.230 AND MAINTAINED IN ACCORDANCE WITH 310 CMR 15.351. 7.) INLET AND OUTLET TEES TO BE PROPERLY SUPPORTED WITH HANGERS AND/OR STRAPS. DISTRIBUTION BOX DETAIL: NOT TO SCALE AS-ELECTRICIAL CONTROL BOX: NO. OF OUTLETS 9 FINISHED GRADE REMOVABLE 2" WALLS NOTES: COVER I y : , 5'1. DIST. BOX TO WITHSTAND H-20 LOADING T PVC MANUFACTURER-SHOREY OR APPROVED EQUAL 1 T 20" 3. CONSTRUCTION SHALL BE WHERE POSSIBLE 6" 9,5" OUTLETS : 8' 4. PROVIDE 2" DRAIN HOLE IN BOTTOM OF D-BOX TO ALLOW ANY RAIN WATER a . �- 11 TO DRAIN. I- 40 5. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. AWJy BOTTOM ON LEVEL STABLE BASE 6" MIN. 3/4" TO CROSS-SECTION STONE BCR ESHED T 1 30" PRECAST DIST. Q BOX DRAIN T T T LESS STEEL 1 RAIL SYSTEM PLAN VIEW ORIFICI ABLE 3" CHECK VALVE GOULDS DUPLEX PUMPS ELEVATION 3" PVC FORCE MAIN ZABEL ORIFICE SHIELD OR APPROVED EQUAL ORIFICE SHIELD OS150CW ORENCO SYSTEMS INC. PHONE 1-800-348-9843 OR EQUAL 3/16" HOLE AT 5' O.C. ALTERNATE BETWEEN 5 AND 7 0 CLOCK FBI* A N NOT TO SCALE ORIFICE SHIELD TO BE SNAPPED SECURELY INTO PLACE AROUND ALL PERFORATIONS ON EACH LATERAL. SLOTS ON ORIFICE SHEILD TO BE LOCATED DIRECTLY OVER EACH PERFORATION. PLACE SHIELD OVER DISTAL PORT. OPTION ORENCO SHIELD 2"DIA. SCH-40 PVC LATERALS SNAP -ON SHIELD DRAINAGE SLOTS REVISIONS NO. DATE DESCRIPTION 1. 2/2/04 BOH EDITS. 2, 12/q/Q4 0, WATFR APO, �1 Bic GROUP 657 Manila St Teett, (RT. 28) U11 k 6 W. Yarmouth Massachusetts ®2673 PROJECT TITLE: SEWAGE DISPOSAL SYSTEM REPAIR "CAPE COD SUPER BUFFET" 228 ROUTE 28 WEST YARMOUTH M ASSACH U SETTS PREPARED FOR: Mr. ZHANG ZI QIAN CAPE COD SUPER BUFFER, INC. 228 ROUTE 28 WEST YARMOUTH MA 02673 (508) 775-8110 DATE: JANI ARY 27, 2004 COMP. DES �N: K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FIELD: D. GAZZOLO / J. MCCARTIN FILE NO. 8608SEP1.DWG DWG NO. 5490-02 SHEET 3 OF 3 JOB NO.4-8608.00 Fj] N 0 N co a d E 0 U U co y Y a 0 0 0 0 0 0 FL a U w w c� 0 3 0 0 0 00 SOIL TEST PIT DATA: TEST PIT _#1- TEST PIT -#2- GRD. EL. 13.7 GRD. EL. 14.4 EST. HIGH GW. 6.2 EST. HIGH GW. 6.1 LOAMY SAND 2.5YR 4 1 4 LOAMYB S ND 10YR 698 1 EL = 12.6 MEDIUM SAND 2.5Y 6/4 54. 4" 0" 02" EL = 3.7 20" DATE: 9 /26 /03 TEST BY: THE BSC GROUP, INC. WITNESSED BY: DAVE FLAHERTY PERC. RATE: 2 MIN./INCH SOIL EVALUATOR CRAIG FIELD SOIL CLASS: 1 L.T.A.R. 0.74 G.P.D./SQ.FT. LOAMY SAND 2.5YR 4 1 LOAMYB SAND 10YR 6/8 EL = 13.1 MEDIUM SAND 2.5Y 6/4 4" 15" 100" 112" EL = 3.9 126" DATE: 9 /26 /03 TEST BY: THE BSC GROUP, INC. WITNESSED BY: DAVE FLAHERTY PERC. RATE: 2 MIN./INCH SOIL EVALUATOR CRAIG FIELD SOIL CLASS: 1 L. T. A. R. 0.74 G.P.D. /SQ. FT. TEST PIT -- GRD. EL. 14.3 EST. HIGH GW. 7.8 78" 94" DATE: 12 /1 /04 TEST BY: THE BSC GROUP, INC. WITNESSED BY: N/A PERC. RATE: NZA-MIN./INCH SOIL EVALUATOR CRAIG FIELD SOIL CLASS: N/A L.T.A.R. N A G.P.D./SQ.FT. TEST PIT ----#A GRD. EL. 13.8 EST. HIGH GW. 7.8 PROFILE: NOT TO SCALE - ALL COMPONENTS TO BE H-20 EL.= A MANHOLES do COVERS AS REQUIRED EL.- VARIES (BRING TO FINISH GRADE) /4' PVC SCH 40 I=E NOTE: CAST IRON _ ON GREASE LINE NOTE: USE FERNCC CONNECTOR ON S� \IMti I=D 6" STONE BASE 4,000 GALLON (P) PRECAST CONCRETE GREASE TRAP 22,000 GALLON (P) PRECAST CONCRETE SEPTIC TANK INVERT ELEVATIONS: TOP OF FOUNDATION 4" INVERT AT BUILDING (GREASE) ' 4" INVERT AT GREASE TRAP (IN) 4" INVERT AT GREASE TRAP (OUT) 4" INVERT AT BUILDING (SEWAGE) 4" INVERT AT SEPTIC TANK (IN) 4" INVERT AT SEPTIC TANK (OUT) 4" INVERT AT PUMP CHAMBER (IN) 4" INVERT AT PUMP CHAMBER (OUT) INVERTS AT LEACHING FACILITY: 4" INVERT AT BEGINNING OF LEACHING FIELD 4" INVERT AT END OF LEACHING FIELD ELEVATION AT BOTTOM OF LEACHING FIELD ADJUSTED GROUNDWATER ELEVATION OBSERVED GROUNDWATER ELEVATION VARIANCES REQUESTED: 6" STONE BASE I=H DUPLEX PUM CHAMBER 16.00 A NOTE: ♦ ,1 WETLANDS DELINEATED by �- - Mr. BRAD HOLMES OF *E BSC GROUP, INC.1-1 000 7� woo 777 s \ Gam- 46 53 $3 E 244.78' 0 CURRENT DEPTHONDEX WELL(11 /04) 9.2 \ �F O� , / '�' ,, / • WATER LEVEL ADJUSTMENT 2.3 F _ / r *** REQUESTING 1' OFF ADJUSTMENT 1.9 DEPTH TO ADJUSTED HIGH WATER X 0 �- �` r y-'`,q�O / MONOMONO �' 72" S - F 88 _ ®- - 100, X 13. 7 cC t DATE: 12 1 04 TEST BY: THE BSO GROUP, INC. WITNESSED BY: N/A PERC. RATE: NZA MIN./INCH SOIL EVALUATOR CRAIG FIELD SOIL CLASS: N/A L.T.A.R. N/A G.P.D. /SQ. FT. HIGH GROUNDWATER COMPUTATION (BASED ON TP#1) DEPTH TO WATER 8.5 INDEX WELL MIW-29 WATER LEVEL RANGE ZONE A CURRENT DEPTHOINDEX WELL(9/03) 8.6 WATER LEVEL ADJUSTMENT 1.9 *** REQUESTING 0.9' OFF ADJUSTMENT 1.0 DEPTH TO ADJUSTED HIGH WATER 7.5 HIGH GROUNDWATER COMPUTATION BASED ON TP#4 DEPTH TO WATER X INDEX WELL MIW-29 WATER LEVEL RANGE ZONE A INDICATES ESTIMATED SEASONAL HIGH GROUND WATER INDICATES v_ OBSERVED GROUND WATER in DOG INDICATES PERC. TEST ❑INDICATES UNSUITABLE MATERIAL P 72' LONG LEACHING FIELD VARYING PIPE DIAMETER EL-14.0 EL-15.2 EL=14.0 EL=12.3 2'-1 /8"-3/8" DOUBLE WASHED STONE 3/4"-1 1/2" DOUBLE WASHED STONE I=K 2 1=L I=J *0-4 BOTTOM EL. = M N ADJUSTED GROUNDWATER 14.47 B (RAISED & RELOCATED) 14.15 C 13.90 D 12.97 E 12.43 F 12.18 G 12.10 H REVERSE TANK 12.35 J 1 12.3 K BREAKOUT 12.8 12.3 L 11.8 M 7.8 N 6.5 TITLE V: SECTION 15.212: TO ALLOW 4' SEPERATION TO GROUNDWATER IN LIEU OF 5'. TOWN OF YARMOUTH: TO ALLOW 1 FOOT OFF THE 2.3 FOOT ADJUSTMENT REQUIRED. CftM A. IFMD No.3s0M �0 PROPOSED VENT _ LIMITS OF , WITH VENT LINES EXCAVATION UNDER SEE NOTES 1` AREA RONL�D TP#4 5 AND 6 OF �e000O E� BUFF 14.2 X X 13.8 �p0 X 14.2 TP#3 TP#2 INSPECTION GRASS/ PORT STONE .... X 13. _ PARKING AREA ::::� 110' I I 1 SY TE I # 1 S M 2 I I I :: t 14.3 EDGE OF PAVEMENT ----I 66' I I 66' I.... t .... I I I I I I PROPOSED LIMITS OF I 3" PVCHAD \ I I I I EXCAVATION. SEE iv 3 P C A R I I / NOTES T E S 5& 6 .... 3 PVC I i 3 P �.. �� EXISTING BITUMINOUS IY 111.9 I I I I 1.... / X 14.4 PARKING AREA x rn 4i° M --••i I I I .. DISTURBED PAVEMENT ,� 0. _ I - _ , I I_::: TO BE REPAVED TO MATCH `}-� EXISING CONDITION MIN.-:= -------..--- - --J L--. .......... J°�=� w 3NSPEGT30N �PpRT_ :: = = _ :: :: 71 : FrW: FM: . . - - - - . - - - - . 0 14.6 , r r PROPOSED 22 IQs OIO 0S S I"� 11,000 GAL !0 s 6" PVC _ _ _ _ _L__ I L" _ J PUMP CHAMBER to I I r7 � 14 PROPOSED z I s E �"� PROPOSED H-20 4000 GAL. I I D-BOX FOR ELECTRICIAL GREASE Ls REEZER 14.2 CONTROLS TRAP I E�s� UNIT E PROPOSED EXISTING UP ci " RAWL" ELEVATION OF PIPE 22,000 GAL BITUMINOUS 12.6' SEPTIC TANK PARKING AREA PROTECT POLE UP TO BE CONFIRMED DURING RAISE AND FERNCO CONNECTION 3 INSTALLATION RELOCATE TO BE INSTALLED. GREASE LINE BENCHMARK $ TOP OF BASEMENT EXISTING SEPTIC TANK FOUNDATION KITCHEN ELEV 16.00 AREA AREA AND ALL LEACHING 3 AREAS TO BE PUMPED EXISTING AND REMOVED FROM BITUMINOUS SITE IN ACCORDANCE PARKING AREA WITH TITLE 5. EXISTING BITUMINOUS GAS PARKING AREA METER DINING AREA EXISTING 200 \ 3 SEAT RESTAURANT "CAPE COD SUPER BUFFET" UPIEXISTING ( \e BITUMINOUS 0 qS14Q PARKING AREA10. �� \ 3 � CONCRETE BOUND FOUND & HELD PLAN VIEW SCALE: 1' = 20 FEET 0 10 20 40 FT. 3 � �w SI EWAL� UP DESIGN CRITERIA: DESIGN FLOW: 200 SEATS AT 35 G.P.B./D 7000 G.P.D. REQUIRED GREASE TRAP 200 SEATS x 15 GPS = 3000 GAL. GREASE TRAP PROVIDED: = 4000 GAL. CONCRE BOUND FOUND & HELD REQUIRED SEPTIC TANK- 7000 X 300% = 21000 GAL. SEPTIC TANK PROVIDED: = 22000 GAL. SIZE OF LEACHING FACILITY REQUIRED: DESIGN PERC. RATE: <2 MIN./ INCH LONG TERM APPL. RATE 0.74 G.P.D/S.F. 7000 GPD + 0,74 GPD/SF = 9460S.F. z W UP Q a O w c� Ld to M O r-� in to Ai SIZE OF LEACHING FACILITY PROVIDED: 2 (72' x 66') LEACHING FIELDS 72' x 66' = 4752 S.F. 4752 S,F, x 2 FIELDS = 9504 S.F. OF LEACHING AREA 9504 x 0.74 GPD / SF = 7032 GPD PR❑VIDED 70326PD PR❑VIDED > 7000 GPD REQUIRED DATUM: VERTICAL DATUM: N.G. V.D. BENCH MARK USED: FEMA BENCH MARK SET: T.O.F. 16.00 REVISIONS NO. DATE DESCRIPTION 1. 2/2/04 BOH EDITS 2. 12/9/04 G.WATER ADJ. GENERAL NOTES: 1. THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITY ONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D.E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL. 4. THERE ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY NOR ANY KNOWN WELLS PROPOSED WITHIN 150' OF ANY KNOWN LEACHING FACILITY. 5. WITHIN LIMIT OF EXCAVATION REMOVE ALL TOPSOIL, SUBSOIL AND OTHER IMPERVIOUS MATERIAL. 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFORMING TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL PASS No. 50 SIEVE <10 % OF No. 4 SIEVE SHALL PASS No. 100 <5 % OF No. 4 SIEVE SHALL PASS No. 200 UNIFORMITY COEFFICIENT O No. 4 SIEVE </=6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL BE RESPON- SIBLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON- STRUCTION ACTIVITY WITH DIG -SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG -SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82, SECTION 409 AT TEL. 1-888-344-7233. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY. 9. EXITING INVERTS ARE TO BE CHECKED BY THE CONTRACTOR PRIOR TO CONSTRUCTION THE ENGINEER IS TO BE NOTIFIED OF ANY FIELD CHANGES THAT MAY BE REQUIRED. LOCUS INFORMATION CURRENT OWNER: ZHANG ZI QIAN TITLE REFERENCE: DEED BOOK 13354, PAGE 225 PLAN REFERENCE: (NO PLAN - SEE DEED DESC.) ASSESSORS MAP: 37 PARCEL: 148 K 0011 "771- BSC GROUP 5,�7 Man Street, (PT� 28) Unk 5 W. Yarmouth uth Massachusetts 07573 508 778 8919 PROJECT TITLE: ZONING DISTRICT: B2 SETBACKS: FRONT 30' SIDE 25' SEWAGE DISPOSAL REAR 20' MINIMUM LOT SIZE: 20,000 S.F. [E. YSTEM REPAIR EXISTING LOT AREA: 81,899f S.F. DEC 0 2 04 � OVERLAY DISTRICT: R.O.A.D. NITROGEN SENSITIVE HEALT D PT, _ ZONE: NOT A ZONE ii "CAPE COD FEMA FLOOD ZONE DISTRICT: "B", DATED 7/2/1992 SUPER BUFFET" PANEL #250015 0005 D 228 ROUTE 28 i LOCUS PLAN: N❑ SCALE A WEST YARMOUTH ?GAD J ISLAND -� M ASSACH U SETTS - BVC w 13.8' - Y col U t oHw-----_,2'10'00" W 25629' z UP 3 L❑GLIB OHW LiOHW_.- - - - -- � ----------- _ -' SIDE A-LK.... \ ❑ --------- WG 28 Q 3 L,.I �� c� z . : z LiROUTE 28w J. Y Q (STATE HIGHWAY - VARIABLE WIDTH) D ► 7 .•N cy- PREPARED FOR: Mr. ZHANG ZI QIAN CAPE COD SUPER BUFFER, INC. 228 ROUTE 28 WEST YARMOUTH MA 02673 (508) 775-8110 DATE: JANUARY 27, 2004 COMP. DESIGN: K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FIELD: D. GAZZOLO / J. McCARTIN FILE NO. 8608SEP1.DWG DWG NO. 5490-02 SHEET 1 OF 3 JOB NO.4-8608.00 a a