Loading...
HomeMy WebLinkAbout1029 Route 28 plans 10ABBREVIATIONS -A- NUMBER HLAV HANDICAPPED LAVATORY SQ FT SQUARE FEET ABAN ABANDON HORIZ HORIZONTAL SPEC SPECIFICATION ACS DR ACCESS DOOR HTR HEATER SS STAINLESS STEEL AFF ABOVE FINISHED FLOOR HUR HANDICAPPED URINAL STD STANDARD AG AIR GAP - HVAC HEATING, VENTILATION, & AIR STRUC STRUCTURAL AHJ AUTHORITY HAVING JURISDICTION CONDITIONING AMERICAN NATIONAL STANDARDS HW HOT WATER -T- ANSI INSTITUTE HWC HANDICAPPED WATER CLOSET T&P TEMPERATURE AND PRESSURE VALVE AP ACCESS PANEL, ALARM PANEL HWCP HOT WATER CIRCULATION PUMP VALVE TD TRENCH DRAIN AMERICAN SOCIETY OF MECHANICAL HWP HOT WATER PUMP ASME ENGINEERS -I- TDH TOTAL DYNAMIC HEAD AMERICAN SOCIETY OF SANITARY TEMP TEMPERATURE ASSE ENGINEERS ID 'INSIDE DIMENSION TP TRAP PRIMER AMERICAN SOCIETY FOR TESTING & IE INVERT ELEVATION ASTM MATERIALS IN INCH TS TAMPER SWITCH AW ACID WASTE _J- TYP TYPICAL AWWA AMERICAN WATER WORKS JC JANITORS CLOSET _U ASSOCIATION UGND UNDERGROUND _K- -B- UL UNDERWRITERS LABORATORY KW KILOWATT BFF BELOW FINISHED FLOOR UR URINAL -L- BFP BACKFLOW PREVENTOR _V_ LAB LABORATORY BLDG BUILDING V VENT, VOLT, VIDEO LAP LOCAL ALARM PANEL BLW BELOW / UNDERGROUND VB VACUUM BREAKER LAV LAVATORY BLWDN BLOWDOWN VEL VELOCITY LBS POUND(S) BMS BUILDING MANAGEMENT SYSTEM VIF VERIFY IN FIELD LPD LITERS PER DAY _C- VOL VOLUME -M CAP CAPACITY, CAPACITOR VOV VALVE ON VERTICAL MAX MAXIMUM CFM CUBIC FEET PER MINUTE VTR VENT THROUGH ROOF MECH MECHANICAL CL CENTER LINE, CLOSE, CLOSET -W- MED MEDIUM CLG CEILING WIDTH, WASTE, WIRE, WALL PHONE, MER MECHANICAL EQUIPMENT ROOM W WATT CO CLEANOUT MFR MANUFACTURER W/ WITH COND CONDENSATE MGCV MASTER GAS CONTROL VALVE W/O WITHOUT CONN CONNECT, CONNECTION MIN MINIMUM, MINUTE WC WATER CLOSET COORD COORDINATE MS MOP SINK WCO WALL CLEANOUT CU FT CUBIC FEET MTGHT MOUNTING HEIGHT WFS WATER FLOW SWITCH CU IN CUBIC INCH -N- WATER HAMMER ARRESTOR (LETTER CV CHECK VALVE NC NORMALLY CLOSED WHA -A INDICATES P.D.I. SIZE) CW COLD WATER NATIONAL ELECTRICAL WM WATER METER 'D' NEMA MANUFACTURERS ASSOCIATION WMS WIRE MESH SCREEN (D) EXISTING TO BE DEMOLISHED NIC NOT IN CONTRACT WSP WORKING STEAM PRESSURE DEG DEGREE NO NORMALLY OPEN, NUMBER WT WEIGHT DEMO DEMOLITION NP NON -POTABLE WATER WTR WATER DF DRINKING FOUNTAIN NTS NOT TO SCALE WWP .WORKING WATER PRESSURE DIA DIAMETER -0- -Z - DN DOWN OC ON CENTER ZCV ZONE CONTROL VALVE DOM DOMESTIC OD OUTSIDE DIAMETER DR DRAIN ORD OVERFLOW ROOF DRAIN DWG DRAWING OS&Y OPEN STEM AND YOKE DWH DOMESTIC WATER HEATER OCCUPATIONAL SAFETY AND HEALTH -E- OSHA ACT-P- (E)/EX EXISTING TO REMAIN (ER) EXISTING TO BE RELOCATED PIV POST INDICATOR VALVE EJ EJECTOR PLBG PLUMBING EL ELEVATION, ELEVATOR LOBBY PLD PLENUM DRAIN EQ EQUAL POS POSITIVE EQUIP EQUIPMENT PSI POUNDS PER SQUARE INCH EWC ELECTRIC WATER COOLER -R' EWH ELECTRIC WATER HEATER R RISE EWS EYEWASH STATION RD ROOF DRAIN -F- REC RECESSED F FAHRENHEIT, FIRE SERVICE, FEMALE REFR REFRIGERATION FCO FLOOR CLEANOUT REM REMOVABLE FD FLOOR DRAIN REQD REQUIRED FF EL FINISH FLOOR ELEVATION REV REVISED, REVISION FUFLR FLOOR RM ROOM FT FOOT, FEET RO REVERSE OSMOSIS RPM REVOLUTIONS PER MINUTE G GAS, GROUND, GREEN RR ROOF RECEPTOR GAL GALLON -S- GALV GALVANIZED S SOIL GC GENERAL CONTRACTOR SA SHOCK ABSORBER, SUPPLY AIR GPF GALLONS PER FLUSH SAN SANITARY GPH GALLONS PER HOUR SCP SCUPPER GPM GALLONS PER MINUTE SD STORM DRAIN, SMOKE DAMPER/DETECTOR GR FL GROUND FLOOR SE SEWAGE EJECTOR GWH GAS WATER HEATER SED SEWAGE EJECTOR DISCHARGE -H- SK SINK HD HUB DRAIN SMP SUMP PUMP HDC HANDICAPPED SMPD SUMP PUMP DISCHARGE SYMBOLS LEGEND ANNOTATION SCALE! NTS PLAN TITLE NO. -1 1TITLE TITLE MARK DETAIL ' OR PLAN N0. -1 P-201 SCALE: NTS FOUND IN P-201 I 1 DETAIL REFERENCE P-501 DETAIL NO. -1 FOUND IN P-501 SECTION MARK I 1 SECTION NO. -1 P-501 FOUND IN P-501 DETAIL BOUNDARY I 1 J P-201 (RECTANGLE) I DETAIL NO. - 2 I 1Q ISHEETKEYNOTE I I 1 I REVISION CLOUD (DELTA 1) AC ; EQUIPMENT TAG I 1-1 i MARK - AC I I MARK NO. -1-1 P DOMESTIC WATER # RISER DESIGNATION S SANITARY WATER # RISER DESIGNATION ST i STORM WATER RISER # DESIGNATION I NG NATURAL GAS RISER # DESIGNATION � I POINTF 0 � I CONNECTION I POINT OF DISCONNECTION - PLUMBING LINES I NEW PIPING (SEE ABBREVIATION FOR PIPE I.D.) I (E) EXISTING TO REMAIN _ (D) _ _ EXISTING TO BE �pl DEMOLISHED - — — (BLW) - - - - J UNDERGROUND / BELOW - COLD WATER - HOT WATER i - - - HOT WATER RETURN -----V----- VENT CONTROL DEVICES PIPE HEAT TRACER VALVES AIR VENT - AUTOMATIC ® BACK WATER VALVE 101 BALANCING VALVE 101 BALL VALVE BALL VALVE - II MOTORIZED ISI BUTTERFLY VALVE I _ N CHECK VALVE I DIAPHRAGM VALVE DRAIN VALVE FLOAT VALVE i FUSIBLE LINK I D4 GATE VALVE I mm GATE VALVE - OS&Y D� D/4 GLOBE VALVE MASTER GAS — CONTROL VALVE F— PLUG VALVE PLUG SAFETY �... PRESSURE I REDUCING VALVE PRESSURE RELIEF VALVE ® SEISMIC GAS CONTROL VALVE I SOLENOID VALVE o VALVE IN VERTICAL (DROP) I L VALVE IN VERTICAL I (RISE) VALVED AND CAPPED I _CUTLET:_ MISCELLANEOUS _ BACK FLOW BFP PREVENTER HOSE BIBB I METER I TP TRAP PRIMER ® WALL HYDRANT WATER HAMMER wHA _ ARRESTOR - SUFFIX INDICATES PDI SIZE VACUUM BREAKER FITTINGS II— CLEANOUT 0 CLEANOUT TO GRADE C— ELBOW DOWN ELBOW DOWN TO TEE I —0 _ ELBOW UP C END CAP I —�O P -TRAP TEE DOWN 4- TEE SIDE OUTLET DOWN .. TEE SIDE OUTLET UP -0- TEE UP UNION JIL I VENT THROUGH I a I ROOF DRAINS I ® AREA DRAIN 0 FLOOR DRAIN ® FLOOR SINK ® FLOOR SINK W/ HALF GRATE 3.O HUB DRAIN ® ROOF DRAIN ® ROOF DRAIN OVERFLOW I O ROOF RECEPTOR ® TRENCH DRAIN cuccT 1KIM v GENERAL NOTES 1. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. EXACT LOCATION SHALL BE COORDINATED WITH ALL TRADES, THE STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS, AND/OR GENERAL CONTRACTOR AND CONSTRUCTION MANAGER. 2. LOCATION AND SIZES OF EXISTING PIPING ARE APPROXIMATE. VERIFY THE LOCATIONS AND SIZES OF EXISTING PIPING IN THE FIELD. IF ANY DISCREPANCIES OCCUR WITH THE CONTRACT DRAWINGS, NOTIFY THE ARCHITECT AND/OR THE ENGINEER PRIOR TO COMMENCEMENT OF NEW WORK. 3. ALL EXPOSED PIPING PENETRATIONS THROUGH WALLS OR CEILINGS SHALL BE PROVIDED WITH APPROPRIATE FIRE RETARDANT SEALANT AND ESCUTCHEONS. 4. SEAL OPENINGS AROUND PLUMBING WORK AND PIPING THROUGH PARTITIONS, WALLS AND FLOORS (NOT IN SHAFTS) WITH NON-COMBUSTIBLE MATERIAL AND ESCUTCHEONS. 5. SUBMISSION OF A PROPOSAL SHALL BE EVIDENCE THAT A CAREFUL EXAMINATION OF THE SITE, DRAWINGS & SPECIFICATIONS HAVE BEEN MADE AND THE CONTRACTOR IS FAMILIAR WITH THOSE ITEMS AND AREAS THAT WILL PRESENT DIFFICULTY TO THE PERFORMANCE OF THIS CONTRACT. LATER CLAIMS SHALL NOT BE MADE FOR LABOR, EQUIPMENT, ETC. NECESSARY TO COMPLETE ALL WORK AS A RESULT OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN. A. CONTRACTOR TO VERIFY THE EXISTING CONDITIONS BEFORE CONSTRUCTION; CONFIRMING SIZES AND LOCATIONS OF ALL EXISTING PIPING PRIOR TO START OF WORK. B. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKED AND VERIFIED BY THE CONTRACTOR AT THE SITE BEFORE PROCEEDING WITH ANY WORK. C. PRIOR TO STARTING DEMOLITION, DETERMINE LOCATIONS AND EXISTING CONDITIONS. 6. THIS CONTRACTOR SHALL PAY FEES, GIVE NOTICE, FILE NECESSARY DRAWINGS AND OBTAIN PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH WORK UNDER THIS CONTRACT AND COMPLY WITH LOCAL LAWS AND ORDINANCES. 7. PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE AND SAFE INSTALLATION OF MECHANICAL IN FULL CONFORMITY WITH REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION; ALL AS INDICATED ON DRAWINGS AND/OR HEREIN SPECIFIED FOR THE SYSTEMS INCLUDED. WORK SHALL BE INSTALLED IN A NEAT, WORKMANLIKE MANNER. INCLUDE ALL COSTS FOR PERMITS, LICENSES, CERTIFICATES, FILING AND INSPECTIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION. 8. UNDER NO CIRCUMSTANCES WILL THIS CONTRACTOR, OR HIS WORKMEN, BE PERMITTED TO USE ANY PART OF THE BUILDING AS A SHOP EXCEPT PARTS AS DESIGNATED FOR SUCH USE. 9. ALL EXISTING WATER PIPING WITHIN FIVE (5) FT. OF NEW CONNECTIONS SHALL BE PROVIDED WITH NEW INSULATION. 10. REFER TO ARCHITECTURAL DRAWINGS FOR FINAL ADDITIONAL INFORMATION. 11. ALL WORK MUST BE COORDINATED AROUND THE OPERATION OF THE FACILITY. 12. STORE MATERIALS IN DESIGNATED SPACES. 13. UNNECESSARY NOISE SHALL BE AVOIDED AT ALL TIMES AND NECESSARY NOISE SHALL BE REDUCED TO A MINIMUM. 14. ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE CONSTRUCTION DOCUMENTS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER, PRIOR TO SUBMITTING A PROPOSAL OF ANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. 15. REMOVAL OF CERTAIN EXISTING WORK WILL BE NECESSARY FOR THE PERFORMANCE OF THE GENERAL WORK. ALL EXISTING CONDITIONS CANNOT BE COMPLETELY DETAILED ON THE DRAWINGS. THE CONTRACTOR SHALL SURVEY THE SITE AND INCLUDE ALL CHANGES IN MAKING UP WORK PROPOSAL. 16. DISCONNECT, REMOVE AND/OR RELOCATE EXISTING MATERIAL, EQUIPMENT, AND OTHER WORK AS NOTED OR REQUIRED FOR PROPER INSTALLATION OF SYSTEM. 17. THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED DURING CONSTRUCTION TO THEIR ORIGINAL STATE. 18. THE CONTRACTOR SHALL KEEP ALL EQUIPMENT AND MATERIALS, AND ALL PARTS OF THE BUILDING, EXTERIOR SPACES AND ADJACENT STREETS, SIDEWALKS AND PAVEMENTS, FREE FROM MATERIAL AND DEBRIS RESULTING FROM THE EXECUTION OF THIS WORK. EXCESS MATERIALS WILL NOT BE PERMITTED TO ACCUMULATE EITHER ON THE INTERIOR OR THE EXTERIOR. NttsGroup ArchitectSP 905 S. Main St. Bldg B Ste 2:01 Mansfield, MA 02048 781-831-8541 nes-grouparchtects.com ®COPYRIGHT NES GROUP ARCHITECTS, PC. ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT THE WRITTEN CONSENT OF NES GROUP ARCHITECTS, PC. G � SYS . HENNESSY GROUP A member company of SH Group, Inc. 10 Post Office Square Suite 725 Boston, MA 02109 Tel: 617.577,9900 www.s ska.com No. Description Date CC# 0577 1029 MA -28 So. Yarmouth, MA Flooding Remediation & Protection PLUMBING COVER SHEET Project Number 21028 Project Status Permit/Construction Set Date 11/01/22 Drawn By Author Checked By Checker Scale DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE. NUMBER TITLE SCALE P-001 FIRE PROTECTION COVER SHEET NONE P-002 SPECIFICATIONS NONE P-003 SCHEDULES NONE PD -200 BASEMENT DEMOLITION AND PROPOSED PLUMBING FLOOR PLAN 1/4"=1'-0" P-201 PROPOSED GROUND PLUMBING FLOOR PLAN 1/4"=1'-0° P-501 PLUMBING DETAILS NONE GENERAL NOTES 1. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. EXACT LOCATION SHALL BE COORDINATED WITH ALL TRADES, THE STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS, AND/OR GENERAL CONTRACTOR AND CONSTRUCTION MANAGER. 2. LOCATION AND SIZES OF EXISTING PIPING ARE APPROXIMATE. VERIFY THE LOCATIONS AND SIZES OF EXISTING PIPING IN THE FIELD. IF ANY DISCREPANCIES OCCUR WITH THE CONTRACT DRAWINGS, NOTIFY THE ARCHITECT AND/OR THE ENGINEER PRIOR TO COMMENCEMENT OF NEW WORK. 3. ALL EXPOSED PIPING PENETRATIONS THROUGH WALLS OR CEILINGS SHALL BE PROVIDED WITH APPROPRIATE FIRE RETARDANT SEALANT AND ESCUTCHEONS. 4. SEAL OPENINGS AROUND PLUMBING WORK AND PIPING THROUGH PARTITIONS, WALLS AND FLOORS (NOT IN SHAFTS) WITH NON-COMBUSTIBLE MATERIAL AND ESCUTCHEONS. 5. SUBMISSION OF A PROPOSAL SHALL BE EVIDENCE THAT A CAREFUL EXAMINATION OF THE SITE, DRAWINGS & SPECIFICATIONS HAVE BEEN MADE AND THE CONTRACTOR IS FAMILIAR WITH THOSE ITEMS AND AREAS THAT WILL PRESENT DIFFICULTY TO THE PERFORMANCE OF THIS CONTRACT. LATER CLAIMS SHALL NOT BE MADE FOR LABOR, EQUIPMENT, ETC. NECESSARY TO COMPLETE ALL WORK AS A RESULT OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN. A. CONTRACTOR TO VERIFY THE EXISTING CONDITIONS BEFORE CONSTRUCTION; CONFIRMING SIZES AND LOCATIONS OF ALL EXISTING PIPING PRIOR TO START OF WORK. B. ALL DIMENSIONS AND EXISTING CONDITIONS SHALL BE CHECKED AND VERIFIED BY THE CONTRACTOR AT THE SITE BEFORE PROCEEDING WITH ANY WORK. C. PRIOR TO STARTING DEMOLITION, DETERMINE LOCATIONS AND EXISTING CONDITIONS. 6. THIS CONTRACTOR SHALL PAY FEES, GIVE NOTICE, FILE NECESSARY DRAWINGS AND OBTAIN PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH WORK UNDER THIS CONTRACT AND COMPLY WITH LOCAL LAWS AND ORDINANCES. 7. PROVIDE ALL REQUIRED LABOR, MATERIALS, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE AND SAFE INSTALLATION OF MECHANICAL IN FULL CONFORMITY WITH REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION; ALL AS INDICATED ON DRAWINGS AND/OR HEREIN SPECIFIED FOR THE SYSTEMS INCLUDED. WORK SHALL BE INSTALLED IN A NEAT, WORKMANLIKE MANNER. INCLUDE ALL COSTS FOR PERMITS, LICENSES, CERTIFICATES, FILING AND INSPECTIONS REQUIRED BY AUTHORITIES HAVING JURISDICTION. 8. UNDER NO CIRCUMSTANCES WILL THIS CONTRACTOR, OR HIS WORKMEN, BE PERMITTED TO USE ANY PART OF THE BUILDING AS A SHOP EXCEPT PARTS AS DESIGNATED FOR SUCH USE. 9. ALL EXISTING WATER PIPING WITHIN FIVE (5) FT. OF NEW CONNECTIONS SHALL BE PROVIDED WITH NEW INSULATION. 10. REFER TO ARCHITECTURAL DRAWINGS FOR FINAL ADDITIONAL INFORMATION. 11. ALL WORK MUST BE COORDINATED AROUND THE OPERATION OF THE FACILITY. 12. STORE MATERIALS IN DESIGNATED SPACES. 13. UNNECESSARY NOISE SHALL BE AVOIDED AT ALL TIMES AND NECESSARY NOISE SHALL BE REDUCED TO A MINIMUM. 14. ALL APPLICABLE CODES, LAWS AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE CONSTRUCTION DOCUMENTS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR WHO SHALL INFORM THE OWNER, PRIOR TO SUBMITTING A PROPOSAL OF ANY WORK OR MATERIALS WHICH VIOLATE ANY OF THE ABOVE LAWS AND REGULATIONS. ANY WORK DONE BY THE CONTRACTOR CAUSING SUCH VIOLATION SHALL BE CORRECTED BY THE CONTRACTOR. 15. REMOVAL OF CERTAIN EXISTING WORK WILL BE NECESSARY FOR THE PERFORMANCE OF THE GENERAL WORK. ALL EXISTING CONDITIONS CANNOT BE COMPLETELY DETAILED ON THE DRAWINGS. THE CONTRACTOR SHALL SURVEY THE SITE AND INCLUDE ALL CHANGES IN MAKING UP WORK PROPOSAL. 16. DISCONNECT, REMOVE AND/OR RELOCATE EXISTING MATERIAL, EQUIPMENT, AND OTHER WORK AS NOTED OR REQUIRED FOR PROPER INSTALLATION OF SYSTEM. 17. THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED DURING CONSTRUCTION TO THEIR ORIGINAL STATE. 18. THE CONTRACTOR SHALL KEEP ALL EQUIPMENT AND MATERIALS, AND ALL PARTS OF THE BUILDING, EXTERIOR SPACES AND ADJACENT STREETS, SIDEWALKS AND PAVEMENTS, FREE FROM MATERIAL AND DEBRIS RESULTING FROM THE EXECUTION OF THIS WORK. EXCESS MATERIALS WILL NOT BE PERMITTED TO ACCUMULATE EITHER ON THE INTERIOR OR THE EXTERIOR. NttsGroup ArchitectSP 905 S. Main St. Bldg B Ste 2:01 Mansfield, MA 02048 781-831-8541 nes-grouparchtects.com ®COPYRIGHT NES GROUP ARCHITECTS, PC. ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT THE WRITTEN CONSENT OF NES GROUP ARCHITECTS, PC. G � SYS . HENNESSY GROUP A member company of SH Group, Inc. 10 Post Office Square Suite 725 Boston, MA 02109 Tel: 617.577,9900 www.s ska.com No. Description Date CC# 0577 1029 MA -28 So. Yarmouth, MA Flooding Remediation & Protection PLUMBING COVER SHEET Project Number 21028 Project Status Permit/Construction Set Date 11/01/22 Drawn By Author Checked By Checker Scale DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE.