Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1029 Route 28 plans 15
;E WHEN HUBLESS PIPING IS SUSPENDED IN EXCESS OF 18" BELOW STRUCTURE, SWAY BRACING SHALL BE PROVIDED TO PREVENT HORIZONTAL MOVEMENT. LOCATE BRACE EVERY 30 FT. ON STAIGHT RUNS WITH AT LEAST ONE BRACE - ON OFFSETS IN EXCESS OF 10 FEET. SUBMIT DETAILS IF VARIATION IS REQUIRED. SCALE: NONE NO -HUB SWAY BRACING FOR HORIZONTAL PIPING 6 TERMINATE SLEEVE FLUSH WITH FINISHED WALL SURFACES. f% ' t 'F' m STANDARD WEIGHT STEEL PIPE SLEEVE OF SIZE TO PASS PIPE SEAL OR CAULK SLEEVE THRU FIRErr✓ `''`'' AND INSULATION. WALLS IN A SMOKE TIGHT MANNER/ . STUD FINISHED ESCUTCHEON PLATE AGAINST WALL AND Z., OF SIZE TO COMPLETELY COVER OPENING. PIPE AND INSULATION TO BE CENTERED IN sf�X FINISHED WALL SURFACE SLEEVE—DO NOT SUPPORT PIPE FROM SLEEVE. CONCEALED PIPING ------- PIPING EXPOSED TO VIEW SMWF ISOLATOR INTERIOR WALL FLOOR P I--- BRACE -- 4tBRACE INTERMEDIATE JOINTS WITH RISER CLAMPS AND RODS TYPICAL FRICTION CLAMP FLOOR --i I TYPICAL HANGER SECURE BASE OF — — STACK TO BUILDING 0 STRUCTURE WITH BRASS C.O. RISER CLAMP AND RODS OR TRAPESE HANGER SCALE: NONE NO -HUB PIPE BRACING FOR VERTICAL PIPING 3 PIPE THREADED CLEANOUT PLUG STANDARD WEIGHT STEEP PIPE SLEEVE INSTALLED DURING WALL CONSTRUCTION.- CLEANOUT TEE SEALING AND ANCHORING COLLAR } CONTINUOUS WELD ` FINISHED WALL SURVACE f" a SEAL WATERTIGHT WITH ,` SEAL SLEEVE WITH TIGHTLY PACKED MASTIC OR ASPHALT. y°`•: $ COAT EXTERIOR SURFACES f NOTE: CENTER PIPE IN SLEEVE > �, a 1. PIPE SLEEVE FOR EXTERIOR WALL ABOVE OR BELOW GRADE. 2. FOR GAS SERVICE EXTENT SLEEVE 1" PAST INSIDE FACE OF WALL & 4" PAST OUTSIDE FACE OF WALL. SCALE: NONE SCALE: NONE PIPE SLEEVE THROUGH WALL 8 ISOLATION OF PIPING PENETRATION THRU STUD & PLATES 5 77T7 -f., I I ; `. •. STANDARD PIPE I SLEEVE COVERING SHIELD .. .. THREADE FLAME SEAL PUTTY MINIMUM OF 1" THICK ;nf. CLEVIS HAI r,/z DO LE LOCKNUTS I .. .. /z MIN./1 MAX. I OPENING SORROUNDING i PICAL TO ALL) EACH PENETATING PIPE UNINSULA ED PIPES INSULATD PIPES (BELOW 4")(HOT OR COLD) (BELOW 4") ,� PIPE .:. a ` ` STUFFED CERAMIC :.. .:. P FIBER INSULATION WALL OR FLOOR FINISHED WALL SURFACE COVER PLATE WITH SECURING SCREW TAPER THREAD -BRONZE PLUG SCALE: NONE WALL CLEAN OUT r2' COPPER PIPIN AL)OCKNUTS STANDARD COVERING SHIELD DOUBLELOCKNUTS (TYPICAL) LINING 1/4" MIN <NESS NOTES: 1. EQUAL TO TOLCO CLEVIS HANGER WITH FELT LINING. 2. UTILIZE FOR SUSPENSION OF ALL WATER PIPING. NOTE: RAITGER, ROD & INSERT SHALL BE DIPPED IN SCALE: NONE SCALE: NONE ZINC CHROMATE PRIMER PRIOR TO INSTALLATION FIRESTOPPING 7 DETAIL OF PIPE HANGERS 4 TYPICAL PIPE SUPPORT DETAIL SCALE: NONE 1 �r t a NtzbGroup ArchitectSPC 905 S. Main St. Bldg B Ste 201 Mansfield, MA 02048 781-331-8541 nes-grouparchiteets.com ©COPYRIGHT NES GROUP ARCHITECTS, PC. ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT THE WRITTEN CONSENT OF NES GROUP ARCHITECTS, PC. 11 SYSKA HEi NESSY GROUP A member company of SH Group, Inc. 10 Post Office Square Suite 725 Boston, MA 02109 Tel: 617.577.9900 www.syska.com &RS v MKI L. FOX u 'NO.'54403 vg�QNAC�b. No. Description Date Mpr CC# 0577 1029 MA -28 So. Yarmouth, MA Flooding Remediation & Protection PLUMBING DETAILS Project Number 21028 Project status Permit/Construction Set Date 11/01/22 Drawn By Author Checked By Checker P�501 Scale DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE.