HomeMy WebLinkAbout1029 Route 28 plans 16ABBREVIATIONS SYMBOLS EAR EXHAUST AIR REGISTER GENERAL NOTES 2WAY TWO-WAY EAT ENTERING AIR TEMPERATURE 4 DUCT FITTING EAR EXHAUST AIR REGISTER MU MAKE UP WATER LINE 2WAY TWO-WAY EAT ENTERING AIR TEMPERATURE -N- ��211SCALE: NTS 3WAY THREE-WAY EDBT ENTERING DRY BULB TEMP NIC NOT IN CONTRACT -A- TRANSFER AIR BOOT EER ENERGY EFFICIENCY RATIO NO NORMALLY OPEN, NUMBER A/C AIR CONDITION EF EXHAUST FAN NTS NOT TO SCALE AD ACCESS DOOR EL ELEVATION / ELEVATOR LOBBY -0- SECTION MARK ADA AMERICAN DISABILITIES ACT ELEC ELECTRIC / ELECTRICAL OA OUTSIDE AIR ADDL ADDITIONAL EQ EQUAL OD OUTSIDE DIAMETER ADJ ADJUSTABLE ESP EXTERNAL STATIC PRESSURE _P_ (DELTA 1) AFF ABOVE FINISHED FLOOR EWBT ENTERING WET BULB TEMP PD PRESSURE DROP / DIFFERENCE AHJ AUTHORITY HAVING JURISDICTION EWT ENTERING WATER TEMP PERF PERFORATED AHU AIR HANDLING UNIT EXH EXHAUST PH PHASE AIA AMERICAN INSTITUTE OF ARCH EXIST EXISTING PLBG PLUMBING AMP AMPERE -F- POINT OF POS POSITIVE ARCH ARCHITECT F FAHRENHEIT, FIRE SERVICE, FEMALE PRV PRESSURE REDUCING VALVE ASHRAE AMERICAN SOCIETY OF HEATING, FA FACE, FREE AREA, FIRE ALARM PSI POUNDS PER SQUARE INCH (NEW) REFRIGERATION & AIR CONDITIONING FCU FAN COIL UNIT -R- REGISTER, 150 CFM - - - - 1( JDA- ENGINEERS FD FIRE DAMPER (R) REMOVE EXISTING AUTO AUTOMATIC FIN FLR FINISH FLOOR R RISE AVG AVERAGE FLA FULL LOAD AMPERES RA RETURN AIR "B" DUCT UNDER FLEX FLEXIBLE RAG RETURN AIR GRILLE BDD BACKDRAFT DAMPER FLTR FILTER REC RECESSED BFP BACKFLOW PREVENTOR FPM FEET PER MINUTE REFR REFRIGERATION BLDG BUILDING FT FOOT, FEET REG REGISTER BLW BELOW / UNDERGROUND -G- DUCT TRANSITION REM REMOVABLE BTU BRITISH THERMAL UNIT GAL GALLON REQD REQUIRED BTUH BRITISH THERMAL UNIT/ HOUR GALV GALVANIZED RFGT REFRIGERANT "C" SMOKE DAMPER GPM GALLONS PER MINUTE RH RELATIVE HUMIDITY CAP CAPACITY, CAPACITOR GRL GRILLE RHC REHEAT COIL CC COOLING COIL _H- RLA RUNNING LOAD AMPERES CD CEILING DIFFUSER, CONSTRUCTION HD HEAD RLL REFRIGERANT LIQUID LINE DOCUMENT HORIZ HORIZONTAL RM ROOM CFM CUBIC FEET PER MINUTE HP HORSEPOWER RPM REVOLUTIONS PER MINUTE CFSD COMBINATION FIRE/SMOKE DAMPER HVAC HEATING, VENTILATION, & AIR RSL REFRIGERANT SUCTION LINE CH CHILLER CONDITIONING -S CHWP CHILLED WATER PUMP HWP HOT WATER PUMP SA SUPPLY AIR, SHOCK ABSORBER CHWR CHILLED WATER RETURN HWR HOT WATER RETURN SAR SUPPLY AIR REGISTER CHWS CHILLED WATER SUPPLY HWS HOT WATER SUPPLY SD SMOKE DAMPER / DETECTOR, STORM CL CENTER LINE, CLOSE, CLOSET HZ HERTZ DRAIN CLG CEILING -I- SEER SEASONAL ENERGY EFFICIENCY CNDS CONDENSATE DRAIN ID INSIDE DIMENSION SF SQUARE FOOT (FEET) CO2 CARBON DIOXIDE IN INCH SF SUPPLY FAN COND CONDENSER 1NSUL INSULATION SP STATIC PRESSURE CONN CONNECT, CONNECTION _K- SPEC SPECIFICATION CP CONTROL PANEL, CHROME PLATED KW KILOWATT SS S�AINLESS STEEL CV CONSTANT VOLUME _L-, STRUC STRUCTURAL CWP CONDENSER WATER PUMP (L) LINED -T- CWR CONDENSER WATER RETURN LAT LEAVING AIR TEMPERATURE T THROAT CWS CONDENSER WATER SUPPLY LBS POUND(S) TA TRANSFER AIR "D" LH LATENT HEAT TDH TOTAL DYNAMIC HEAD (D) EXISTING TO BE DEMOLISHED LTH LENGTH TEMP TEMPERATURE DB DRY BULB LVR LOUVER TSTAT THERMOSTAT dB DECIBEL LWT LEAVING WATER TEMPERATURE TYP TYPICAL DBA UNIT OF SOUND LEVEL _M- -V- DBT DRY BULB TEMPERATURE MAT MIXED AIR TEMPERATURE V VOLT, VENT, VIDEO DDC DIRECT DIGITAL CONTROL MAX MAXIMUM VAV VARIABLE AIR VOLUME DEG DEGREE MBTUH THOUSAND BTU PER HOUR VD VOLUME DAMPER DIA DIAMETER MECH MECHANICAL VFD VARIABLE FREQUENCY DRIVE DMPR DAMPER MED MEDIUM _W_ DN DOWN MER MECHANICAL EQUIPMENT ROOM W WIDTH, WIRE, WATT, WASTE DPT DEW POINT TEMPERATURE MFR MANUFACTURER W/ WITH DR DRAIN MHP MOTOR HORSEPOWER W/0 WITHOUT DWG DRAWING MIN MINIMUM, MINUTE WB WET BULB "E" MOT MOTOR WMS WIRE MESH SCREEN (E) / EX EXISTING TO REMAIN MS MOTOR STARTER WP WEATHERPROOF, WORKING (ER) EXISTING TO BE RELOCATED MTD MEAN TEMP DIFFERENCE PRESSURE EA EXHAUST AIR MTGHT MOUNTING HEIGHT ANNOTATION DUCT FITTING NEW PIPING (SEE ABBREVIATION FOR PIPE I.D. (SEE DETAILS)' TITLE MARK EXISTING TO REMAIN M-101 DETAIL OR PLAN ri_N�TITLE CONNECTION NUMBER -1 DETAIL OR PLAN ��211SCALE: NTS BUTTERFLY VALVE N REF LOCATION p� FLOAT VALVE FOUND IN M-201 FUSIBLE LINK TRANSFER AIR BOOT DETAIL --� ---- REFERENCE DETAIL 1 NUMBER -1 M-501 SCHEDULE DETAIL FOUND IN PLUG SAFETY M-501 R J1 RELIEF VALVE SECTION MARK SOLENOID VALVE SECTION NUMBER - _ TRANSFER AIR 1 SECTION FOUND M-501 ELBOW WITH IN E-501 #O ACOUSTIC LINING SHEET KEYNOTE 1 END CAP REVISION CLOUD SOUND ATTENUATOR -�- (DELTA 1) �DETAIL 21 BOUNDARY B DETAIL NUMBER - 2 M-201 THROW PATTERN 4 - WAY, 100 CFM EQUIPMENT TAG; AC CR-ACEILING vI DESIGNATION AC, 1-1 TYPE A, 100 CFM DESIGNATION CEILING EXHAUST 100 NUMBER 1-1 ® CEILING SUPPLY LOUVER IN DOOR 1.0 F.A. MINIMUM 1.0 SQ FT, EXISTING TO REMAIN FREE AREA EXISTING TO BE V/y POINT OF SIDEWALL SUPPLY CONNECTION DIFFUSER POINT OF DIFFUSER DISCONNECTION DUCT SUPPLY REGISTER, DUCTWORK 150 CFM (NEW) 12"X6" SIDEWALL DUCTWORK (EXISTING) (E) 15500 REGISTER, 150 CFM - - - - 1( JDA- DUCTWORK - - EXISTING TO BE �- - - - - - - DEMOLISHED) -------------- DUCTWORK -------------- WITH ACOUSTIC ----------____-_ LINING ® ACCESS PANEL DUCT UNDER POSITIVE PRESSURE DUCT UNDER Ca NEGATIVE PRESSURE VAV WITH REHEAT RISE IN DUCT —UP -v► ----- (IN DIRECTION OF AIR ATTENUATOR FLOW) SINGLE DUCT ----- DROP IN DUCT —DN -0- REHEAT AND (IN DIRECTION OF AIR ATTENUATOR FLOW) REHEAT COIL -�}-�-) FLEX DUCT DUCT TRANSITION SHUT-OFF VAV BOX VANED ELBOW HEATING COIL AND OUTLET BOX RADIUS ELBOW COMBINATION �-- SMOKE/FIRE DAMPER PIPING DUCT FITTING NEW PIPING (SEE ABBREVIATION FOR PIPE I.D. (SEE DETAILS)' ,E, EXISTING TO REMAIN M-101 FLEXIBLE DUCT VALVES CONNECTION BALL VALVE Ifl BUTTERFLY VALVE N CHECK VALVE p� FLOAT VALVE p°a FUSIBLE LINK TRANSFER AIR BOOT GATE VALVE --� ---- [� Ibl (STRAIGHT) SEE OS&Y VALVE ISI SCHEDULE s �I PLUG SAFETY REQUIREMENTS R J1 RELIEF VALVE SOLENOID VALVE VALVED AND CAPPED OUTLET OFF I TRANSFER AIR FITTINGS I I ELBOW WITH Ji" ACOUSTIC LINING ELBOW UP �--- END CAP sa SOUND ATTENUATOR -�- CEILING SUPPLY CD -A ® DIFFUSER, TYPE A, 100 THROW PATTERN 4 - WAY, 100 CFM RETURN CR-ACEILING vI REGISTER (GRILLE), 100 TYPE A, 100 CFM EG -A ® CEILING EXHAUST 100 TYPE A, 100 CFM CEILING SUPPLY WITH BLANKING PLATE (3 -WAY) EXISTING TO REMAIN IC 71 EXISTING TO BE V/y DEMOLISHED SIDEWALL SUPPLY DIFFUSER LINEAR SLOT DIFFUSER 12X6 WR 12"X6" SIDEWALL SUPPLY REGISTER, 150 150 CFM 12X6 WG 12"X6" SIDEWALL RETURN / EXHAUST 15500 REGISTER, 150 CFM ROUND SUPPLY DIFFUSER ® ROUND RETURN DIFFUSER FLOOR REGISTER El (GRILLE) K I ACCESS PANEL SINGLE DUCT VAV BOX Ca SINGLE DUCT VAV WITH REHEAT SINGLE DUCT ----- VAV BOX WITH ATTENUATOR SINGLE DUCT ----- VAV BOX WITH ----- REHEAT AND ATTENUATOR DUAL DUCT VAV BOX FAN POWERED VAV BOX SHUT-OFF VAV BOX WITH HYDRONIC HEATING COIL AND OUTLET BOX COMBINATION �-- SMOKE/FIRE DAMPER ►— FIRE DAMPER D— SMOKE DAMPER 0-- BACK DRAFT DAMPER f VOLUME DAMPER TQ THERMOSTAT PIPING TITLE NEW PIPING (SEE ABBREVIATION FOR PIPE I.D. M-001 ,E, EXISTING TO REMAIN M-101 EXISTING TO BE DEMOLISHED VALVES 101 BALL VALVE Ifl BUTTERFLY VALVE N CHECK VALVE p� FLOAT VALVE p°a FUSIBLE LINK D4 GATE VALVE x GLOBE VALVE [� Ibl MOTORIZED BALL VALVE OS&Y VALVE ISI PLUG VALVE s �I PLUG SAFETY PRESSURE REDUCING R J1 RELIEF VALVE SOLENOID VALVE VALVED AND CAPPED OUTLET OFF I BACK FLOW PREVENTER FITTINGS o ELBOW DOWN ELBOW DOWN TO TEE —Q ELBOW UP ] END CAP TEE DOWN -�- TEE UP UNION 1. WHERE THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, NOTIFY THE ENGINEER PRIOR TO BID. FOR BIDDING PURPOSES THE MORE STRINGENT SHALL APPLY. 2. THE CONTRACTOR SHALL EXAMINE THE COMPLETE SET OF CONTRACT DOCUMENTS FOR ALL TRADES, AS ISSUED BY THE ARCHITECT AND REVIEW DIMENSIONS, SPACE REQUIREMENTS AND POINT OF CONNECTIONS TO ALL EQUIPMENT. MAKE ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICTS WITH THE BUILDING STRUCTURE AND THE WORK OF OTHER TRADES. 3. UNLESS INSTRUCTED OTHERWISE, THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, AND FEES REQUIRED FOR INSTALLATION OF THE MECHANICAL WORK. FURNISH FINAL CERTIFICATE OF INSPECTION OR WRITTEN EVIDENCE OF ACCEPTANCE BY INSPECTION AUTHORITIES FOR ALL WORK INSTALLED. 4. REFER TO COMPLETE DRAWING PACKAGE FOR EXTENT OF CONSTRUCTION, AND EXACT LOCATION OF FIXTURES, EQUIPMENT, DEVICES, ETC. 5. CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO ENSURE AN UNDERSTANDING OF THE COMPLETE SCOPE OF PROJECT PRIOR TO START OF WORK. 6. ALL EQUIPMENT & MATERIALS SHALL MATCH DESIGN SPECIFICATIONS AND MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS. 7. LOCATION OF DUCTWORK IS APPROXIMATE. ALL DRAWINGS AND LAYOUT ARE DIAGRAMMATIC TO SHOW DESIGN INTENT ONLY. CONTRACTOR TO COORDINATE ALL DUCTWORK AND PIPING WITH ALL OTHER WORK IF FIELD CONDITIONS DIFFER SIGNIFICANTLY FROM THOSE SHOWN ON THE DRAWINGS AND AFFECT WORK, INFORM ARCHITECT IMMEDIATELY BEFORE PROCEEDING WITH THAT AREA. 8. INSTALL FIRE DAMPER OR COMBINATION FIRE/SMOKE DAMPER ON ALL DUCTS PENETRATING FIRE RATED ENCLOSURES AND PARTITIONS, AND RATED CEILINGS OF HORIZONTAL EXITS. THE CONTRACTOR SHALL INTERLOCK ALL COMBINATION FIRE/SMOKE DAMPERS WITH LISTED AREA TYPE SMOKE DETECTORS IN THE BUILDING FIRE LIFE SAFETY SYSTEM. VERIFY WITH LIFE SAFETY SYSTEM CONTRACTOR. SEE FIRE ALARM SPECIFICATION AND SMOKE CONTROL NOTES FOR ADDITIONAL INFORMATION. 9. AIR HANDLING UNITS AND FAN COIL UNITS SHALL BE PROVIDED WITH DUCT SMOKE DETECTORS AT THE UNITS OUTLET WHEN THE UNITS CAPACITY EQUALS 2000 CFM OR GREATER. 10. A MINIMUM OF 36" CLEAR WORKING SPACE, NOT LESS THAN 30" WIDE, SHALL BE MAINTAINED IN FRONT OF ALL SWITCHES, OVERCURRENT DEVICES AND ELECTRIC CONTROL COMPONENTS. THE WORKING SPACE SHALL BE CLEAR AND EXTEND FROM THE GRADE, FLOOR, OR PLATFORM TO MINIMUM OF 6'-8" FT. WHERE THE ELECTRICAL EQUIPMENT EXCEEDS 6-1/2 FT IN HEIGHT, THE MINIMUM HEADROOM SHALL NOT BE LESS THAN THE HEIGHT OF THE EQUIPMENT. 11. A MINIMUM OF 24" CLEAR WORKING SPACE SHALL BE PROVIDED IN FRONT OF THE ACCESS PANELS. 12. THE SMOKE DETECTORS LOCATED AT AIR MOVING EQUIPMENT SHALL SHUT DOWN ALL AIR HANDLING EQUIPMENT VIA THE LIFE SAFETY SYSTEM. WHEN SMOKE IS DETECTED AT EQUIPMENT, ALL OTHER AIR MOVING EQUIPMENT LOCATED IN OR CONNECTED TO COMMON PLENUM OR SMOKE ZONE SHALL SHUT DOWN. 13. ALL ELECTRICAL CONTROLS FOR THE SMOKE CONTROL SHALL BE RATED FOR SUCH USE. 14. PROVIDE ACCESS PANELS (MATCH WALL OR CEILING RATING) IN ALL WALLS OR CEILINGS WHERE ACCESS TO DAMPERS, CONTROLS, ETC ARE REQUIRED BY CODE. COORDINATE LOCATIONS WITH ARCHITECT. 15. CONTRACTOR SHALL NOTE THE CRITICAL SPACE AVAILABLE ABOVE CEILINGS, PROVIDE TRANSITION PIECES AT CROSSOVERS, UNDER BEAMS, OVER/UNDER PIPES, AS REQUIRED TO ACCOMMODATE DUCTS WITHIN SPACE AVAILABLE, PROVIDING EQUIVALENT DUCT SIZE TO THE DIAMETER SHOWN. COORDINATE CLOSELY WITH OTHER TRADES TO REDUCE NECESSITY OF TRANSITIONS TO A MINIMUM. NO ADDITIONAL COSTS WILL BE PAID FOR ANY REQUIRED TRANSITIONS OR OTHER SPECIAL CHANGE SHAPE PIECES. ALL DUCTWORK SHALL BE SUPPORTED AND SEISMICALLY RESTRAINED PER THE CALIFORNIA BUILDING CODES AND SMACNA STANDARD. 16. THERE SHALL BE NO PIPING AND/OR DUCTWORK RUN THROUGH ELECTRICAL ROOMS UNLESS THAT DUCTWORK AND/OR PIPING IS SERVING THAT ELECTRICAL SPACE. 17. ALL FLEXIBLE DUCT CONNECTIONS TO AIR DISTRIBUTION DEVICES TO BE MAX. 5'-0" ACOUSTICAL FLEX DUCT PER SPECIFICATIONS. 18. NOT ALL SYMBOLS, NOTES, DETAILS AND EQUIPMENT IN SCHEDULES ON GENERAL SHEETS WILL APPLY TO EACH BUILDING. THEY ARE TO COVER ALL BUILDINGS AND WILL APPLY BASED ON SCOPE IN BUILDING. 19. LOCATE EXISTING REINFORCING STEEL UTILIZING ANY SUITABLE METAL DETECTION SYSTEM. DO NOT CUT ANY EXISTING STEEL REINFORCEMENT. SHIFT ANCHOR OR CORE TO MISS THE REBAR. 20. BOLTS MUST BE INSTALLED TO AVOID DAMAGING EXISTING STEEL REINFORCEMENT. IN CASE OF CONFLICT, ADJUST BOLT LOCATION, ALLOWING FOR 1" CONCRETE COVER BETWEEN REBAR AND BOLT. 21. PROVIDE TRANSFER DUCTS AS NECESSARY ABOVE CEILING FOR RETURN AIR PATH TO AIR HANDLING EQUIPMENT SERVING THAT SPACE. REFER TO DETAILS FOR TRANSFER DUCT SIZES. SHEET INDEX NO. TITLE SCALE M-001 MECHANICAL COVER SHEET NONE M-101 MECHANICAL FLOOR PLAN 1/4"=1'-0" } n NESGroup ArchitectsPC 905 S. Main St. Bldg B Ste 201 Mansfield, MA 02048 781-331-8541 nes-grouparchitects.com ©COPYRIGHT NES GROUP ARCHITECTS, PC. ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT THE WRITTEN CONSENT OF NES GROUP ARCHITECTS, PC. E; . GROUP A member company of SH Group, Inc. 10 Post Office Square Suite 725 Boston, MA 02109 Tel: 617.577.9900 www.syska.com ' N<xl L. Fax -, NO -644w .rs � is c R,A 5T�i�' IVAL`E�� No. Description Date CC#0557 1029 MA -28 So. Yarmouth, MA FLOODING REMIDIATION & PROTECTION MECHANICAL COVER SHEET Project Number 22-004480 Project StatLPERMIT/CONSTRUCTION Date 11/01/22 Drawn By KO Checked By NF M�001 Scale NONE DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE.