HomeMy WebLinkAbout1029 Route 28 plans 19SCALE: 1/4" = l' -O"
ELECTRICAL BASEMENT LIGHTING PLAN
SHEET NOTES
1. REFER TO E-001 FOR LEGEND, ABBREVIATIONS
AND GENERAL NOTES.
2. REFER TO ARCHITECTURAL DRAWINGS FOR
EXACT LOCATIONS, MOUNTING HEIGHTS AND
COLOR OF DEVICES.
IV Mb Group
3. REFER TO ARCHITECTURAL DRAWINGS FOR
EXACT LOCATIONS OF THE LIGHTING FIXTURES.
ArchitectsPC
4. REFER TO MECHANICAL AND PLUMBING
905 S. Main St. Bldg B Ste 201
DRAWINGS FOR EXACT LOCATIONS OF
Mansfield, MA 02048
EQUIPMENT.
781-331-8541
5. ALL WIRING AND CONDUITS FOR EXISTING
nes-grouparchitectscom
MECHANICAL UNIT SHALL REMAIN, UNLESS
STATED OTHERWISE.
6. DISCONNECT AND REMOVE ALL EXISTING
LIGHTING FIXTURES AND LIGHTING CONTROL
DEVICES IN THE AREA INDICATED. REMOVE ALL
ASSOCIATED CONDUIT AND WIRING BACK TO
SOURCE.
7. CONTRACTOR TO SITE VERIFY THE EXISTING
PANEL LOAD PRIOR TO CONNECT NEW LOAD.
8. ALL EXISTING DEVICES TO REMAIN, U.O.N.
PROVIDE PROTECTION TO EXISTING DEVICES T(
AVOID DAMAGING DEVICES DURING NEW
CONSTRUCTION WHERE NEEDED.
9. ALL PROPOSED WORK SHALL BE THOROUGHLY
COORDINATED WITH THE OWNER PRIOR TO
COMMENCING WORK.
10. PROVIDE PROGRAMMABLE TIMER SWITCH FOR
LIGHTING FIXTURES.
0 SHEET KEYNOTES
1. EXISTING PANELS TO REMAIN.
2. PROVIDE NEW WIRING, FUSED DISCONNECT
SWITCH AND CONDUIT FOR NEW MECHANICAL
UNIT EF -1, CONNECT TO EXISTING PANEL AND
PROVIDE DEDICATED CIRCUIT.
3. DEMOLISH EXISTING DISCONNECT SWITCH AND
ASSOCIATED WIRING BACK TO SOURCE. PROVIE
NEW WIRING, FUSED DISCONNECT SWITCH AND
CONDUIT FOR THE NEW SUMP PUMP, CONNECT
TO EXISTING PANEL AND PROVIDE DEDICATED
CIRCUIT.
4. PROVIDE NEW WIRING AND CONDUIT FOR NEW
LIGHTING FIXTURES AND CONNECT TO EXISTIN(
CIRCUIT.
5. DEMOLISH ALL EXISTING RECEPTACLES, WIRIN(
AND CONDUITS BACK TO SOURCE, ON WALL
WITHIN DEMOLITION SCOPE OF WORKS.
'gl
M -
v
R
CC# 0577
1029 MA -28
So. Yarmouth, MA
Flooding
Remediation &
Protection
ELECTRICAL
BASEMENTPLA
FProject Number 21028
Project Status Perm wconstruction Set
Date 11/01/22
Drawn By Author
roject Number
Project Status
.t.
n
Checked By Checker
E WNW&
H�i 00
Scale 1/4111 = 1 1-011
DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN.
VERIFY ALL DIMENSIONS ON SITE.