Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1029 Route 28 plans 3
SPECIFICATIONS DIVISION -GENERAL REQUIREMENTS 06200 - FINISH CARPENTRY AND CASEWORK 09250 P GYPSUM BOARD SYSTEMS 1. FIELD MEASUREMENTS: TAKE FIELD MEASUREMENTS BEFORE ORDERING OR FABRICATING SHOP -FABRICATED 1. SOLID WOOD FOR STANDING AND RUNNING TRIM: SELECT WHITE MAPLE, QUARTER SAWN, AWI, GRADE 1. 1. DIMENSIONS SHOWN ON PLANS ARE TO CENTER OF FRAMING, UNLESS OTHERWISE NOTED. ITEMS. DO NOT SCALE DIMENSIONS OFF DRAWINGS. WHERE SURROUNDING CONSTRUCTION WILL NOT BE BUILT IN 2. INSTALLATION: DISCARD WARPED, BOWED, AND SIMILARLY DEFECTIVE MATERIALS. INSTALL MILLWORK 2. MATERIALS: TIME TO BE MEASURED, PROVIDE MEANS FOR FIELD ADJUSTMENTS AT TIME OF INSTALLATION. PLUMB, LEVEL, TRUE, AND ALIGNED WITH ADJACENT MATERIALS. USE CONCEALED SHIMS WHERE REQUIRED a. METAL FRAMING: FURNISH STEEL STUDS, RUNNERS, FURRING CHANNELS, FURRING BRACKETS AND 2. STUDY DRAWINGS AND COMPARE THE DRAWINGS AND NOTES WITH EACH OTHER. REPORT ANY DISCREPANCIES FOR ALIGNMENT. SCRIBE AND CUT TO FIT ADJOINING WORK. I RELATED COMPONENTS COMPLYING WITH AS1 M C 645, MANUFACTURED FROM COLD -ROLLED STEEL, DISCOVERED TO THE ARCHITECT IN WRITING AND REQUEST CLARIFICATION BEFORE PROCEEDING WITH THE a. INSTALLATION TOLERANCES: 1/8 INCH IN 8 FEET FOR PLUMB AND LEVEL. 1/16 INCH MAX. OFFSET OF ASTM A 568 OR A525 WITH PROTECTIVE COATING. • MINIMUM METAL THICKNESS 0.0179 INCH (25 WORK. ADJACENT "FLUSH" SURFACES FOR FLUSH INSTALLATION. I GAUGE) BEFORE APPLICATION OF PROTECTIVE COATING; 0.0329 INCH. 3. TEMPORARY CONTROLS: PERFORM WORK IN A MANNER WHICH MINIMIZES DISTURBANCE TO OTHER TENANT b. JOINERY: USE FULL-LENGTH PIECES, TO MINIMIZE NUMBER OF JOINTS. MATCH COLOR AND GRAIN b. GYPSUM BOARD: ASTM C 36, WITH LONG EDGES TAPERED FOR JOINT FINISHING; LENGTHS EQUAL TO ACTIVITIES. WITHOUT LIMITATION: PATTERN ACROSS JOINTS. STAGGER JOINTS IN ADJACENT AND RELATED STANDING AND RNNN1NG FULL HEIGHT OF WALL (NO END JOINTS). a. INSIDE THE BUILDING, ISOLATE THE CONSTRUCTION AREA INSIDE DUST BARRIERS, TO THE EXTENT TRIM AND RAILS. COPE AT RETURNS AND MITER AT COMERS TO PRODUCE TIGHT -FITTING JOINTS C. BASE LAYER FOR TWO -LAYER WORK: ASTM C 442 OR ASTM C 36. POSSIBLE WITHOUT OBSTRUCTING OPERATIONS. CONTAIN CONSTRUCTION MATERIALS AND DEBRIS INSIDE WITH FULL -SURFACE CONTACT THROUGHOUT LENGTH OF JOINT. SCARF END-TO-END JOINTS. d. FASTENERS: ASTM C1002 BUGLE -SHAPED, PHILLIPS HEAD, DRYWALL SCREWS, TYPE "S" WITH SELF - THE ENCLOSED AREA, OR IN OTHER STORAGE AREAS DESIGNATED BY THE OWNER. DRILLING POINTS FOR 25 GAUGE STUDS; TYPE US -12" FOR 20 GOUGE STUDS. b. PERFORM CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH CONSTRUCTION RULES AND REGULATIONS, 06410 - LAMINATE -CLAD CASEWORK AND COUNTERTOPS e. TRIM: GALVANIZED STEEL WITH PERFORATED FLANGES; CORNER BEAD EQUAL TO USG "DUR-A-BEAD" UNLESS PRIOR AUTHORIZATION IS OBTAINED FROM THE OWNER. COORDINATE HOURS OF OPERATION 1. AWI QUALITY STANDARD: COMPLY WITH APPLICABLE REQUIREMENTS OF "ARCHITECTURAL WOODWORK (100 SERIES) 1" X R; CONTROL JOINTS EQUAL TO USG NO.093; EDGE MOLDINGS EQUAL TO USG "200 WITH THE OWNER. QUALITY STANDARDS" PUBLISHED BY THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) EXCEPT AS SERIES." C. DO NOT EXPOSE BUILDING OCCUPANTS TO HAZARDOUS OR OFFENSIVE MATERIALS. OTHERWISE INDICATED. I f. JOINT FINISHING MATERIALS: ASTM C475. PERFORATED TAPE. CHEMICAL -HARDENING JOINT d. DO NOT INTERRUPT BUILDING SERVICES (PLUMBING, HEAL. VENTILATION, ELECTRICITY, SECURITY 2. PLASTIC LAMINATE: HIGH PRESSURE DECORATIVE LAMINATE (HPDL) COMPLYING WITH NEMA LD 3, LAMINATED COMPOUND FOR BEDDING AND FILLING; VINYL -BASE COMPOUND -TYPE FOR TOPPING; MOISTURE - SYSTEMS, DATA AND COMMUNICATIONS SYSTEMS) WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE TO MEDIUM DENSITY (45 LB. MINIMUM) FIBERBOARD OR PARTICLEBOARD CORE. FURNISH WATERPROOF RESISTANT TYPE FOR FINISHING JOINTS IN TILE BACKER BOARD. OWNER. I PLYWOOD CORE FOR WET" COUNTER KITCHEN/LOUNGE. 3. INSTALL STEEL STUD FRAMING IN ACCORDANCE WITH ASTM C-754 AND DETAILS. SPACE STUDS 16" O.C. e. DO NOT SHUT-OFF OR DISABLE FIRE DETECTION AND FIRE SUPPRESSION SYSTEMS WITHOUT PRIOR a. MANUFACTURER: REFER TO LEGEND. UNLESS OTHERWISE SHOWN WRITTEN APPROVAL BY FIRE MARSHAL. IF TEMPORARY SHUT-OFF IS PERMITTED, GIVE ADEQUATE PRIOR b. COLORS: AS NOTED ON THE DRAWINGS. 4. PROVIDE STEEL STUD "KICKERS" WHERE REQUIRED TO SUPPORT AND HOLD FIRM SOFFITS, FASCIAE, SMALL NOTICE TO THE OWNER, KEEP DOWN-TIME BRIEF, AND PROVIDE ADEQUATE TEMPORARY PROTECTION 3. LAMINATE COVERED CABINETS: FULL FLUSH OVERLAY STYLE, FABRICATED TO MEET AWI SECTION 400 AREAS OF DROPPED CEILING AND THE LIKE. SUCH AS PORTABLE FIRE -EXTINGUISHERS ACCEPTABLE TO THE AUTHORITIES HAVING JURISDICTION. "CUSTOM GRADE". 5. RELATED WORK: WOOD BLOCKING IN PARTITIONS IS SPECIFIED IN SECTION 06100. f. TEMPORARY HEAT AND VENTILATION: MAINTAIN TEMPERATURE INSIDE THE BUILDING BETWEEN 55° AND 75° a. HINGES: CONCEALED TYPE; 180'; SELF-CLOSING. 6. INSTALL GYPSUM BOARD IN ACCORDANCE WITH ASTM C-840. INSTALL BOARDS VERTICAL, FULL HEIGHT OF F, AND RELATIVE HUMIDITY TO AVOID DAMAGING OWNER'S FURNISHINGS, FINISHES AND EQUIPMENT. b. PULLS: SATIN STAINLESS STEEL "STAPLE" PULLS, 5/16" DIAMETER X 4" HIGH. WALL. FOR TWO -LAYER WORK, INSTALL FIRST LAYER OF BOARDS HORIZONTAL; OR INSTALL FIRST LAYER PROVIDE ADDITIONAL HEAT, VENTILATION, AND DEHUMIDIFICATION DURING WET WORK TO PREVENT MOLD C. MAGNETIC CATCHES, WITH KEYED ALIKE LOCKS ON DOORS AND DRAWERS. VERTICAL AND STAGGER JOINTS OF SECOND LAYER. TOPE JOINTS AND FINISH WITH THREE COATS OF JOINT GROWTH. d. DRAWER SLIDES: ACCURIDE FULL EXTENSION TYPE; SIZED FOR 100 LB. LOAD. COMPOUND OVER JOINTS, FASTENER HEADS AND FLANGES OF METAL TRIM. (SECOND AND THIRD COATS 9. DURING TIMES WHEN SELECTIVE DEMOLITION AND OTHER DUST -MAKING OPERATIONS ARE IN PROGRESS, e. LEVELERS: MANUFACTURER'S STANDARD. I I MAY BE OMITTED ABOVE SUSPENDED CEILINGS, UNLESS REQUIRED FOR FIRE RATING.) SAND JOINTS IF THE BUILDING HVAC SYSTEM IS GOING TO BE IN USE, REMOVE THE PERMANENT FILTERS FROM THE 4. LAMINATE COVERED TOPS: CONFORM TO AWI SECTION 400 C "CUSTOM GRADE". SMOOTH AND FLUSH WITH FACE OF DRYWALL HVAC SYSTEM AND REPLACE WITH TEMPORARY FILTERS OF AT LEAST 30% EFFICIENCY. AT CONTRACTOR'S 5. INSTALLATION OF CABINETS: HANG WALL CABINETS PLUMB, WITH TOP AND BOTTOM SURFACES PARALLEL TO 7. GYPSUM BOARD INSTALLATION TOLERANCES OPTION, SUBJECT TO APPROVAL OF THE ARCHITECT AND THE LOCAL AUTHORITIES HAVING JURISDICTION, FLOOR. LEVEL AND PLUMB FLOOR CABINETS. ANCHOR CABINETS TO BUILT-IN BLOCKING'OR TO STRIPPING a. PLUMB, LEVEL, AND FLAT: DO NOT EXCEED A VARIATION OF 3/16" IN V-0", AND 1/8" IN 4'-0" (ALL TEMPORARY VENTILATING AND HEATING EQUIPMENT MAY BE USED. ATTACHED TO WON SUBSTRATES. SCRIBE TO FLANKING WALLS; FURNISH ADDITIONAL SCRIBE PIECES DIRECTIONS). 4. SUBMITTALS: MATCHING CABINETS, IF REQUIRED. COMPLETE THE INSTALLATION OF HARDWARE. ADJUST HARDWARE TO b. JOINTS BETWEEN PANELS: DO NOT EXCEED 1/16" OFFSET OF PLANES. a. COORDINATE AND REVIEW SUBMITTALS FROM SUBCONTRACTORS BEFORE TRANSMITTING TO THE CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE SMOOTH OPERATION, 1 09510. ACOUSTICAL CEILINGS ARCHITECT. VERIFY MATERIALS, FIELD DIMENSIONS, ADJACENT CONSTRUCTION, FEASIBILITY, 6. INSTALLATION OF COUNTERTOPS: ANCHOR SECURELY TO SUPPORTS OR TO CASEWORK, AS INDICATED. SET 1. REFER TO SCHEDULES AND PLAN FOR TYPES AND COLORS. COORDINATION WITH OTHER WORK, AND CONFORMANCE WITH THE CONTRACT DOCUMENTS. STAMP WITH BACKSPLASH IN A BED OF SANITARY SILICONE SEALANT. SCRIBE TOP EDGE OF SPLASH TO WALL. SEAL JOINT 2. ATTACHMENT DEVICES: SIZE FOR 5 TIMES THE DESIGN LOAD INDICATED IN ASTM C 635, TABLE 1, DIRECT CONTRACTOR'S APPROVAL STAMP, AND SIGN. BETWEEN TOP AND WALL WITH SANITARY SILICONE SEALANT. HUNG, UNLESS OTHERWISE INDICATED. COMPLY WITH SEISMIC DESIGN REQUIREMENTS b. ATTACH A TRANSMITTAL FORM WHICH SHOWS THE PROJECT NAME, SUBMITTAL DATE, AND THE NAME OF 7. SOLID SURFACES: CONFORM TO AWI SECTION 400 C "CUSTOM GRADE". 3. WIRE HANGERS, BRACES, AND TIES: THE CONTRACTOR AND SUBCONTRACTOR, SUPPLIER OR MANUFACTURER; IDENTIFIES THE ITEM AND CALLS a. ZINC -COATED CARBON -STEEL WIRE (TYPICAL); ASTM A 641/A 641M, CLASS 1 ZINC COATING, SOFT OUT DEVIATIONS FROM THE CONTRACT DOCUMENTS, IF ANY. DIVISION 8 - DOORS AND WINDOWS TEMPER. C. SHOP DRAWINGS: PREPARE DRAWINGS SPECIFIC TO THIS PROJECT; DO NOT SUBMIT MANUFACTURER'S b. AIRCRAFT CABLE SYSTEM KIT, AS PROVIDED BY MANUFACTURER FOR SOUNDSCAPE CANOPIES. PRE-PRINTED STANDARD DETAILS. DRAW AT A SCALE APPROPRIATE TO THE WORK. SHOW FIELD 08100. DOOR OPENINGS; STEEL AND WOOD SWINGING DOORS C. SIZE: PROVIDE YIELD STRENGTH AT LEAST 3 TIMES THE HANGER DESIGN LOAD (ASTM C 635, TABLE 1, DIMENSIONS ADJACENT CONSTRUCTION. 1. SUBMITTALS: DIRECT HUNG), BUT NOT LESS THAN 0.106 -INCH- DIAMETER WIRE. d. SAMPLES: SUBMIT SAMPLES OF INTERIOR FINISHES ALL AT THE SAME TIME TO PERMIT COORDINATED a. MANUFACTURER'S DESCRIPTIVE LITERATURE, TECHNICAL SPECIFICATIONS AND ILLUSTRATIONS 4. SEISMIC STRUTS: MANUFACTURER'S STANDARD PRODUCT DESIGNED TO ACCOMMODATE SEISMIC FORCES. SELECTION OF COLORS. PROVIDE SAMPLES OF ADEQUATE SIZE TO PERMIT PROPER EVALUATION OF SHOWING DETAILS OF CONSTRUCTION OF DOORS AND FRAMES. 5. CEILING SUSPENSION SYSTEM INSTALLATION: COMPLY WITH ASTM C 636 AND CISCA'S "CEILING SYSTEMS MATERIAL. ATTACH IDENTIFYING TAG. b. CATALOGUE CUTS FOR EACH ITEM OF HARDWARE. HANDBOOK. INSTALL ACOUSTICAL TILES IN COORDINATION WITH SUSPENSION SYSTEM AND EXPOSED 5. PRODUCTS AND SUBSTITUTIONS: C. SHOP DRAWINGS: FOR DOORS AND FRAMES. SHOW ELEVATIONS OF FRAMES AND DIMENSIONED MOLDINGS AND TRIM. a. FURNISH PRODUCTS SPECIFIED OR SCHEDULED, OR FORMALLY REQUEST SUBSTITUTIONS IN WRITING. SECTIONS AT LARGE SCALE. INDICATE MATERIALS, GAUGES, HARDWARE, LOCATION b. SUBSTITUTIONS WILL BE CONSIDERED ONLY WHEN THE SPECIFIED MATERIAL IS NO LONGER REINFORCEMENT, AND INSTALLATION DETAILS. 1 09650- RESILIENT FLOORING MANUFACTURED, OR WHEN THE SUBSTITUTION OFFERS THE OWNER SAVINGS IN COST OR PROJECT TIME d. DOOR SCHEDULE: LIST EACH INDIVIDUAL OPENING AND INDICATE MARK, HAND, LOCATION, SIZE, TYPE. 1. TILE: VINYL COMPOSITION TILE (VCT) COMPLYING WITH ASTM F1066, COMP. 1. OR BETTER PERFORMANCE AT THE SAME PRICE. e. SAMPLES: WOOD DOOR FACE VENEER. a. MANUFACTURER AND PRODUCT: ARMSTRONG "EXCELON" C. WHEN REQUESTING A SUBSTITUTION, PROVIDE SUFFICIENT INFORMATION ABOUT BOTH THE NAMED 2. REFERENCED STANDARDS: b. SIZE: 12" X 12"X 1 /8" THICK. PRODUCT AND THE SUBSTITUTION TO PERMIT THE ARCHITECT TO JUDGE THE MERITS OF THE PROPOSED a. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI); ANSI A250.8, "RECOMMENDED SPECIFICATIONS 2. RESILIENT BASE: ROPPE OR JOHNSONITE. 4" & 4" REVEAL, HIGH COVE BASES AT VCT, STRAIGHT BASE AT SUBSTITUTION. FOR STANDARD STEEL DOORS AND FRAMES". j CARPET. REFER TO DRAWINGS FOR LOCATIONS AND TYPE. d. INFORM THE ARCHITECT OF CHANGES WHICH WILL HAVE TO BE MODE TO OTHER WORK TO ACCOMMODATE b. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSL)/DOOR AND HARDWARE INSTITUTE (DHI): ANSI/DHI 3. INSTALLATION OF RESILIENT TILE: THE SUBSTITUTION. MAKE THESE CHANGES AT NO ADDITIONAL COST TO THE OWNER. A115 SERIES, PREPARATION FOR BOLTS, CLOSERS, LATCHES, LOCKS, AND PIVOTS IN STEEL DOORS a. TILE LAYOUT: UNLESS ANOTHER PATTERN IS SHOWN, LAY TILE FROM CENTER MARKS, SQUARE TO e. FOR ITEMS EXPOSED TO VIEW, FURNISH ITEM WITH CUSTOM COLOR OR FINISH IF NECESSARY TO MATCH SPECIFIED COLOR OR FINISH. (AT NO ADDITIONAL COST TO OWNER) AND FRAMES. IROOM WINDOW AND DOOR ASSOCIATION "INDUSTRY AXIS, BALANCING LAY -OUT AND AVOIDING CUT TILES NARROWER THAN 3". MATCH FOR COLOR C. NATIONAL WOOD (NWWDA) NWWDA I.S.1 STANDARD AND PATTERN. (FULL 6. PROTECT MATERIALS STORED ON SITE FROM DAMAGE. LEAVE PROTECTIVE WRAPPINGS ON MATERIALS UNTIL THE FOR WOOD FLUSH DOORS". I b. BOND TIGHTLY TO FLOOR (OR WALL) WITH SPREAD OF ADHESIVE. TIME OF INSTALLATION. d. DOOR AND HARDWARE INSTITUTE (DHI) "INSTALLATION GUIDE FOR DOOR AND HARDWARE" AND C. INSTALL EDGE STRIPS BETWEEN RESILIENT FLOORING AND CARPET. INSTALL REDUCER STRIPS 7. INSTALLATION, GENERAL: AS A MINIMUM, COMPLY WITH GENERALLY ACCEPTED INDUSTRY STANDARDS AND WITH "RECOMMENDED LOCATIONS FOR BUILDER'S HARDWARE". I WHERE EDGE OF RESILIENT FLOORING WOULD OTHERWISE BE EXPOSED. PRODUCT MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ADDITIONAL RECOMMENDATIONS FOR 3. FIRE -RATED ASSEMBLIES: COMPLY WITH NFPA STANDARD NO. 80. FURNISH DOORS AND FRAMES LABELED BY d. DAMP MOP (DO NOT WASH) AND PROTECT WITH TWO COATS OF POLISH. KEEP TRAFFIC OFF THE BEST PERFORMANCE AND APPEARANCE. IN ADDITION, COMPLY WITH MORE STRINGENT REQUIREMENTS UL, WARNOCK-HERSEY OR SIMILAR INDEPENDENT TESTING SERVICE ACCEPTABLE TO AUTHORITIES HAVING FLOOR FOR AT LEAST FIVE DAYS. DESCRIBED IN THESE NOTES. WHERE CODES AND REGULATIONS GOVERN INSTALLATION - FOR EXAMPLE FIRE- JURISDICTION. TEST DOOR AND FRAME AND HARDWARE AS A COMPLETE FIRE DOOR ASSEMBLY. 4. FINAL CLEANING: SCRUB, RINSE AND DRY FLOORS. APPLY 3 COATS OF COMMERCIAL FLOOR POLISH. RATED ASSEMBLIES AND ELECTRICAL WORK. - INSTALL WORK IN STRICT COMPLIANCE WITH THESE CODES. 4. STEEL DOOR FRAMES: 16 GAUGE; DRYWALL PROFILE UNLESS OTHERWISE SHOWN; FULLY WELDED; FINISH PROTECT FLOORS WITH SUITABLE COVER UNTIL CONSTRUCTION IS COMPLETED. 8. SELECTIVE DEMOLITION; CUTTING AND PATCHING: WITH ONE COAT RUST -INHIBITIVE PRIMER. a. PERFORM SELECTIVE DEMOLITION AS INDICATED ON THE DRAWINGS AND AS REQUIRED TO 5. WOOD DOORS: FLUSH, SOLID CORE DOORS CONFORMING TO NWWDA I.S. 7 -PLY CONSTRUCTION WITH CORE 09680 - CARPET ACCOMMODATE NEW WORK UNDER THIS CONTRACT. GLUED TO STILES AND ROILS. CUSTOM GRADE. 1. REFER TO SCHEDULES AND PLAN FOR TYPES AND. COLORS. b. CUT, FIT AND PATCH NEW AND EXISTING WORK AS REQUIRED TO COMPLETE THE WORK, TO MAKE ITS a. FACE VENEER: BIRCH PAINT GRADE ( a. PATCHING AND LEVELING COMPOUND: TROWELABLE, LATEX -MODIFIED, PORTLAND -CEMENT -BASED SEVERAL PORTS FIT TOGETHER PROPERLY. b. CORE: PARTICLEBOARD. FORMULATION PROVIDED OR APPROVED BY CARPET MANUFACTURER. C. BEFORE CUTTING ANY STRUCTURAL MEMBER OBTAIN WRITTEN APPROVAL FROM THE ARCHITECT. PROVIDE C. SIZE DOORS SO THEY DO NOT REQUIRE MORE THAN 1/2" FIELD TRIMMING OVERALL, ALLOW FOR 1/8" b. CARPET ADHESIVE: WATERPROOF, STRIPPABLE ADHESIVE. TEMPORARY SUPPORT AS NECESSARY UNTIL THE STRUCTURE IS REPAIRED. CLEARANCE AT HEAD, JAMBS AND BETWEEN PAIRS; 3/4" CLEARANCE BETWEEN BOTTOM AND FINISH 2. EXTRA MATERIALS: FOR MAINTENANCE STOCK, FURNISH ADDITIONAL CARPET FROM SAME DYE LOT IN d. WHEN CUTTING EXTERIOR WALLS, ROOF, OR ROOFING, AND WHEN REMOVING EXTERIOR WINDOWS OR FLOOR. QUANTITY EQUAL TO 2% OF SQUARE FOOTAGE INSTALLED. DOORS, PROVIDE TEMPORARY WEATHER PROTECTION AND SECURITY CLOSURE ACCEPTABLE TO THE 6. DOOR HARDWARE: 3. INSTALLATION: GLUED DOWN WITH WATERPROOF ADHESIVE. OWNER UNTIL WORK IS CLOSED IN. a. HINGES; STANELY 5 -KNUCKLE FULL MORTISE a. COMPLY WITH RECOMMENDATIONS OF CARPET AND RUG INSTITUTE "SPECIFIER'S HANDBOOK". e. REPLACE FIRE STOPPING AND SMOKE BARRIERS WHICH ARE REMOVED OR DAMAGED DURING NONREMOVABLE HINGE PINS FOR EXTERIOR AND PUBLIC INTERIOR EXPOSURE b. IN EACH ROOM OR AREA USE CARPET FROM ONLY ONE DYE -LOT. CONSTRUCTION; RESTORE TO ORIGINAL FIRE -RESISTANCE RATING. BALL-BEARING HINGES FOR DOORS WITH CLOSERS AND ENTRY DOORS. C. CLEAN, PATCH, AND LEVEL SUBSTRATE. j f. CUTTING: SELECT METHODS WHICH WILL NOT DAMAGE OTHER WORK AND WHICH WILL LEAVE REMAINING 3 HINGES FOR 1 -3/4 -INCH- THICK DOORS 90 INCHES OR LESS IN HEIGHT. d. PREPARE SURFACES AND INSTALL CARPET MATERIALS IN ACCORDANCE WITH MANUFACTURER'S CONSTRUCTION IN PROPER CONDITION TO RECEIVE REPAIRS, PROTECT ADJACENT WORK BY b. LOCKSETS/LATCHETS: BHMA A156.2, SERIES 4000, GRADE 1 FOR BORED LOCKS AND LATCHES. INSTRUCTIONS AND APPROVED SUBMITTALS. APPROPRIATE METHODS. C. LOCK CYLINDERS: CONSULT WITH OWNER TO DETERMINE REQUIRED KEYING. e. MAINTAIN UNIFORMITY OF CARPET DIRECTION AND LAY OF PILE. FIT SECTIONS OF CARPET PRIOR TO g. PATCHING; SELECT MATERIALS AND METHODS SO THAT THE COMPLETED WORK COMPLIES WITH THE d. CLOSER: LCN MODEL 94011 APPLICATION OF ADHESIVE. APPLY ADHESIVE UNIFORMLY TO SUBFLOOR. BUTT EDGES TIGHT TO REQUIREMENTS OF THESE CONTRACT DOCUMENTS. MATCH THE ORIGINAL MATERIALS, IF POSSIBLE, e. SILENCERS: 3 PER LEAF. FORM SEAMS WITHOUT GAPS. ROLL ENTIRE AREA LIGHTLY TO ELIMINATE AIR POCKETS. KEEP UNLESS OTHERWISE INDICATED. PATCH SURFACES EXPOSED TO VIEW SO THAT PATCH IS NOT VISIBLE. f. STOPS: ONE PER DOOR; FLOOR MOUNTED, U.O.N. ADHESIVE OFF THE FACE OF THE CARPET, 1F ADHESIVE DOES GET ON FACE, REMOVE IT PROMPTLY h. REFINISHING: REFINISH CONTINUOUS SURFACES TO NEAREST INTERSECTION; FOR AN ASSEMBLY, REFINISH g. FINISH: BRUSHED CHROME, U.N.O. USING MANUFACTURER'S RECOMMENDED CLEANING AGENT. THE ENTIRE UNIT PROVIDE ON EVEN FINISH MATCHING ADJACENT SURFACES OF THE SAME TYPE. 7, INSTALL STEEL FRAMES IN ACCORDANCE WITH SDI 105. INSTALL FRAMES SQUARE TO WITHIN 1/16" OF 90' AND f. INSTALL CLEAR ANODIZED SCHLUTER TRANSITION STRIPS WHERE CARPET MEETS TILE FINISH. 9. ROUTINE CLEANING: AT THE END OF EACH DAY'S WORK, AND MORE FREQUENTLY IF NECESSARY, CLEAN THE PLUMB TO WITHIN 1/16" OVERALL. I I 1 4. CLEAN AND VACUUM CARPET: PROTECT FROM TRAFFIC UNTIL SUBSTANTIAL COMPLETION. CONSTRUCTION AREA. REMOVE AND DISPOSE OF PACKING MATERIALS, EXCESS CONSTRUCTION MATERIALS, a. PROVIDE AT LEAST THREE WALL ANCHORS PER JAMB. FOR OPENINGS 90 INCHES (2286 MM) OR MORE TRASH AND DEBRIS. IN HEIGHT, INSTALL AN ADDITIONAL ANCHOR AT HINGE AND STRIKE JAMBS. 09900 - PAINT 10. FINAL CLEANING: CLEAN WORK THOROUGHLY JUST BEFORE INSPECTION. 8. WOOD DOOR INSTALLATION: SEAL DOOR EDGES PROMPTLY AFTER THEY ARE DELIVERED TO THE SITE. ALIGN 1. ACCEPTABLE MANUFACTURERS: SHERWIN-WILLIAMS. a. EMPLOY SKILLED WORKMEN. EMPLOY CLEANING MATERIALS AND METHODS RECOMMENDED BY DOORS IN FRAMES WITH UNIFORM CLEARANCES AND BEVELS. 1 2. COLORS: MATCH COLORS SCHEDULED; MIX CUSTOM COLORS IF COLOR SELECTED BY ARCHITECT IS NOT MANUFACTURER FOR SPECIFIC ITEM TO BE CLEANED. DO NOT USE HAZARDOUS SOLVENTS OR ABRASIVE a. IF DOORS HAVE NOT BEEN FACTORY -FITTED TO FRAMES, TRIM TO FIT FRAMES; SEAL CUT EDGES STANDARD WITH THE APPROVED PAINT MANUFACTURER. CLEANERS. PROMPTLY AFTER FITTING. ! 3. PAINT SYSTEMS: BEST PROFESSIONAL GRADE PAINTS b. REMOVE GREASE, MASTIC, ADHESIVE, DUST, DIRT, STAINS, FINGERPRINTS, LABELS FROM SURFACES b. COMPLETE THE HARDWARE PREPARATION. SEAL CUT SURFACES AFTER FITTING AND MACHINING. a. STEEL: SHERWIN WILLIAMS "PROMAR 200" INTERIOR ALKYD SEMI GLOSS EXPOSED TO VIEW. I C. FINISH INSTALLATION OF HARDWARE. ADJUST HARDWARE FOR SMOOTH OPERATION; REPLACE b. INTERIOR WOOD, PAINTED: SHERWIN WILLIAMS "PROMER 200" INTERIOR ALKYD SEMI GLOSS C. VACUUM FLOORS AND DUST OTHER SURFACES. DUST LIGHT FIXTURES AND CLEAN LENSES AND CLEAN DOORS AND HARDWARE WHICH CANNOT BE FITTED AND ADJUSTED TO OPERATE PROPERLY. C. INTERIOR WOOD, CLEAR FINISH: POLYURETHANE VARNISH - SATIN FINISH. LENSES AND BAFFLES. d. GYPSUM BOARD: PVA PRIMER SEALER AND TWO TOP COATS OF LATEX PAINT, LOW SHEEN, SHERWIN d. WASH AND POLISH GLASS AND MIRRORS. 08800. GLAZING WILLIAMS "PROMAR 200." ON CEILING SOFFITS, PAINT FINISH IS TO BE FLAT. 11. RECORD DOCUMENTS: 1. FLOAT GLASS: ASTM C 1036, TYPE I, CLASS 1 (CLEAR), AND QUALITY Q3. 4. PREPARATION. COMPLY WITH POINT MANUFACTURER'S RECOMMENDATIONS RELATIVE TO POINT AND a. MAINTAIN AT THE SITE ONE COPY OF THE DRAWINGS AND ONE COPY OF THE SPECIFICATIONS AND MARK 2. TEMPERED: ASTM C 1048, TYPE II, CLASS 1, FORM 3, QUALITY Q8, KIND FT, FINISH F1. SUBSTRATE TYPE: THESE UP TO INDICATE ACTUAL PRODUCTS AND INSTALLATIONS WHICH VARY SUBSTANTIALLY FROM THE 3. SEALED INSULATING -GLASS UNITS: PREASSEMBLED UNITS COMPLYING WITH ASTM E 774 FOR CLASS CBA a. REMOVE WALL PLATES, SURFACE MOUNTED HARDWARE, AND SIMILAR ITEMS WHICH ARE NOT BEING WORK AS ORIGINALLY SHOWN. GIVE PARTICULAR ATTENTION TO CONCEALED WORK WHICH WOULD BE TO UNITS, WITH TWO 6.0 -MM- THICK SHEETS OF GLASS SEPARATED BY A 1/2 -INCH DEHYDRATED SPACE FILLED PAINTED. MASK ITEMS WHICH CANNOT BE REMOVED. MEASURE AND RECORD AT A LATER DATE. REQUIRE MECHANICAL AND ELECTRICAL TRADES TO RECORD WITH ARGON. b. LAY DROP CLOTHS TO PROTECT FLOORS AND FURNISHINGS AND EQUIPMENT WHICH CANNOT BE THEIR OWN WORK. REMOVED DURING PAINTING. b. NOTE RELATED CHANGE -ORDER NUMBERS WHERE APPLICABLE. DIVISION 9 - FINISHES C. CLEAN AREAS JUST PRIOR TO PAINTING AND KEEP THEM FREE OF DUST UNTIL POINT DRIES. C. AT COMPLETION OF THE CONSTRUCTION WORK, OBTAIN FROM THE ARCHITECT A CLEAN SET OF 5. FIELD SAMPLES: 100 SF OF EACH COLOR AT LOCATION INDICATED BY ARCHITECT. IF LIGHTING IS NOT YET DRAWINGS. EMPLOY A PROFESSIONAL DRAFTER TO TRANSFER RECORD INFORMATION FROM THE MARKED- FINISHES, GENERAL REQUIREMENTS: INSTALLED, SIMULATE FINISH LIGHTING CONDITIONS TO ENABLE ARCHITECT TO JUDGE THE COLOR. ADJUST UP PRINTS TO THE FINAL RECORD DRAWINGS. SHOW REROUTINGS, CHANGES, ACTUAL PRODUCTS USED, 1. FIELD MEASURE FOR QUANTITIES; DO NOT SCALE DRAWINGS. FURNISH EXTRA MATERIAL FOR PATTERN COLOR UNTIL ITIS APPROVED BY ARCHITECT. ACTUAL SIZES, ETC. BUT DO NOT ERADICATE OR OBSCURE THE ORIGINAL INFORMATION. MATCHING. 6. APPLICATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR BRUSH, ROLLER, & SPRAY 12. CLOSEOUT SUBMITTALS: SUBMIT THE FOLLOWING AS A PREREQUISITE TO FINAL PAYMENT.2. COLORS ARE SCHEDULED IN THE FINISH SCHEDULE. IF NOT SCHEDULED, THEY WILL BE SELECTED BY THE APPLICATIONS, INCLUDING COVERAGE RATE. a. RECORD DRAWINGS AND RECORD SPECIFICATIONS. ARCHITECT FROM THE MANUFACTURER'S STANDARD COLORS, UNLESS CUSTOM COLOR OR MATCH a. NEW GYPSUM HOARD: ONE PRIME COAT A AND TWO TOP COATS; USE BRUSH OR ROLLER; DO NOT b. OPERATING AND MAINTENANCE DATA: BIND DATA, INCLUDING FLOW -CHARTS AND DIAGRAMS, AND ARCHITECT'S SAMPLE" OR SIMILAR REQUIREMENT IS SPECIFIED. 'i SPRAY. INCLUDING ONE COPY OF EACH WARRANTY, IN A 3 -RING, 8-1/2" X 11" BINDER. LABEL BINDER WITH NAME OF 3. FURNISH ADHESIVES AND ACCESSORIES RECOMMENDED BY FINISH MANUFACTURER TO SUIT PROJECT b. PREVIOUSLY PAINTED GYPSUM BOARD: SPAT PRIME NEWLY SPACKLED AREAS; APPLY TWO TOP PROJECT; SEPARATE ITEMS WITH TABBED DIVIDERS. CONDITIONS. COOTS BY BRUSH OR ROLLER. C. EXTRA STOCK, SPARE PARTS AND SIMILAR MAINTENANCE ITEMS. WRAP, LABEL, AND PLACE IN STORAGE AT 4. FLOOR PREPARATION: BEFORE LAYING RESILIENT FLOORING OR CARPET, FILL SMALL CRACKS AND LOW C. NEW STEEL FRAMES; ONE PRIME COOT AND TWO TOP COATS; APPLY BY SPRAY. LOCATION DESIGNATED BY OWNER. AREAS WITH LATEX UNDERLAYMENT, GRIND DOWN RIDGES. REMOVE PAINT, OILS, WAXES, SEALERS, AND d. PREVIOUSLY PAINTED STEEL: REMOVE RUST. SPOT PRIME BARE STEEL; APPLY TWO TOP COOTS. d. WARRANTIES: BIND EXECUTED ORIGINALS INTO A 3 -RING, 8-1/2" X 11" BINDER. LABEL BINDER WITH NAME OF CURING COMPOUNDS NOT COMPATIBLE WITH THE ADHESIVE. JUST BEFORE LAYING FLOORING, BROOM e. WOOD DOORS: FACTORY FINISH TO MATCH CUSTOM STAIN. PROJECT; SEPARATE ITEMS WITH TABBED DIVIDERS. CLEAN OR VACUUM. INSTALL SAMPLE AND TEST FOR BOND; MAKE CORRECTIONS NECESSARY TO ENSURE f. WOOD TRIM: ONE COAT SANDING SEALER; STAIN TO MATCH ARCHITECT'S SAMPLE; THREE COATS e. CERTIFICATE OF OCCUPANCY RELIABLE BOND. I CLEAR VARNISH. SAND LIGHTLY BETWEEN COATS. f. CERTIFICATES OF INSPECTION. FOR ELECTRICAL WORK AND PLUMBING AND FOR OTHER SYSTEMS IF 5. WALL PREPARATION: SPACKLE AND SAND AS NECESSARY TO PROVIDE A SMOOTH, EVEN SURFACE FAR 7. QUALITY STANDARDS FOR APPLICATION: SMOOTH, EVEN APPEARANCE WITH EVEN COLOR AND SHEEN. NO REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. APPLICATION OF FINISHES. FILL VOIDS AND JOINTS AT PERIMETER OF DRYWALL AND BETWEEN DRYWALL AND SKIPS, DRIPS, HOLIDAYS, SUCTION SPOTS OR AREAS WHERE PREVIOUS COOTS OR PRIME COAT SHOWS OTHER CONSTRUCTION, SUCH AS DOOR FRAMES, WITH PAINTABLE ACRYLIC OR URETHANE SEALANT. THROUGH. DIVISION 6 - WOOD AND PLASTICS 6. FLOORING APPLICATION: UNLESS OTHERWISE SHOWN, EXTEND FLOOR COVERING INTO TOE SPACES, DOOR 8. CLEAN-UP: COMPLY WITH REGULATIONS GOVERNING DISPOSAL OF HAZARDOUS WASTES. DO NOT WASH REVEALS, AND INTO CLOSETS AND SIMILAR OPENINGS. PAINTS DOWN DRAIN. 06100 - ROUGH CARPENTRY 7. PAINTING: POINT ALL EXPOSED METAL, WOOD, AND GYPSUM BOARD SURFACES EXCEPT FOR 1. BLOCKING AND NAILERS: PROVIDE WOOD BLOCKING IN PARTITIONS FOR SUPPORT OF WALL -MOUNTED ITEMS SUCH AS ARCHITECTURAL METALS (STAINLESS STEEL, BRONZE, CHROME, ETC.) AND ITEMS WHICH ARE SHOP - PLUMBING FIXTURES, GRAB BARS, SHELVING, COUNTERS, WHETHER OR NOT SHOWN. BLOCKING: FIRE -RETARDANT FINISHED. PAINT SURFACES BEHIND MOVEABLE CONSTRUCTION SUCH AS SHELVING. PAINT EXPOSED PIPING TREATED "UTILITY" GRADE LUMBER. AND CONDUIT. ;T NESGroup ArchitectsPC 905 S. Main St. Bldg B Ste 201 Mansfield, MA 02048 781-331-8541 nes-grouparchitects.com ©COPYRIGHT NES GROUP ARCHITECTS, PC. ALL RIGHTS RESERVED. NO USE OR REPRODUCTION OF THIS MATERIAL IS PERMITTED WITHOUT THE WRITTEN CONSENT OF NES GROUP ARCHITECTS, PC. EDp��i r ROP, MA OFM No. Description Date � F .� r_ a ✓ & CC# 0577 1029 MA -28 So. Yarmouth, MA Flooding Remediation & Protection Specifications Project Number 21028 Project Status Perm it/Construction Set Date 11/01/22 Drawn By Author Checked By Checker G�002 Scale 1/411 _ 1 1_011 DO NOT SCALE DRAWING, USE DIMENSIONS SHOWN. VERIFY ALL DIMENSIONS ON SITE.