Loading...
HomeMy WebLinkAboutEngineer Plany^S VOST LEACHING (TO BE REMOVED) T TBM : P A TI O 1�O CORNER EL. 13.32 Oh EXISTING EAST SEPTIC TANK (TO 8E REMOVED) p�SHED TO BE REMOVED 14.6 12.6'V 2.8 X PRE. 1 SOOG SEPTIC TANK c9G N ry to, ?� O 5p, M PROP 30X20 12 ,o R U A'91l 19� LEACHING FIELD \ 3� �s O gq�x�s, •�l ' s a \�� ' — OAF. �Y A 12.7 _ _�•_ _ tI IZ�L� 219 kp q} EXISTING ,� DWELUNG 1 1 As PROPOSED ENCLOSED I o I vent' CONNECTOR 12.5 F` 12.2 X n0 \ > ..-� VE 13.1 \ �. Vlt \ X 13. Z \ \.\ 2p.0 y 12.7 X � \ 13.9 ss' LOT s 0 � F U 12.5 X \ \ s 13.1 F CpN �X" �o tiF�o 'All wQ' R`25.00 LEGEND -}}—� PROPOSED CONTOUR ® PROPOSED SPOT GRADE EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W--- EXISTING WATER SERVICE li TEST PIT SCALE: 1 "=30' Yarmouth Health Department APPROVED ame Date 12.9 SOUTH YARMOUTH NT c. LOCUS MAP -)-3 LOCUS INFORMATION TITLE REF: LCC 226444 PLAN REF: LCP 28577-A PARCEL ID: MAP 051 PAR. 12.3 PROPERTY NOT IN ZONE 11 FLOOD ZONE: "X" (0.2%) COMMUNITY PANEL. 25001C-0587-J DATED:07/16/14 PROPOSED SITE & SEPTIC PLAN LOCATED AT: 219 PLEASANT STREET SOUTH YARMOUTH, MA PREPARED FOR JAMES MODISETTE NOVEMBER 15, 2022 0OF WSJ' EDMRD c A. D FiRA STONE MEYER �o 0. O No_ 1140 �5 G TS QNI40� MEYER & SONS, INC. P.O. BOX 981 aCCC�dC� EAST SANDWICH, MA. 02537 JAN 12 2023 PH: (508)360-3311 HEALTH DEPT. FAX: (774)413-9468 meyerandsonstitle50gmoil. COm SHEET 1 OF 2 ELEV. TOP DROP FND. (Existing) = 13.65 - INV. 9.50 F.G.EL: 13.2 NOTE: PLACE ALL COVERS TO WITHIN 6" OF FINISH GRADE INSTALL METAL RINGS/COVERS TO GRADE. IF SURFACE IS PAVED. F.G.EL: 13.2 F.G. EL: 13.10 NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE FINISHED GRADE (13.10) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA INSPECTION PORT TO GRADE 6' NWECTiON PORT TO WTM of STIOM 10-1 TEE'S ARE TO BE INV. 8.0157 0 *0 :00. INV. 8.80 • • ::••::••:i •i;� �••wj •i ••;•w:;� �•ii� w; �.;; �.: i•; �:��jw•�j.•: GAS PROPOSED DB-6 w._ew._M. .w•. •. Aw. w.. . ew. ..•.. .N.�.w_.• BAFFLE DISTRIBUTION BOX J0 PROP. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY NOTES: TUF-TITE. ZABEL. OR EQUAL 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK AND D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS LISTED BELOW: - 310 CMR 15.405 (1) (B): 1) A 2-02 FT. VARIANCE FROM 310CMR15.221(7) TO ALLOW LEACHING TO BE 5.02 FT (MAX) BELOW GRADE VS REO'D 3 FT, (H20/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER, 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE 8.ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING TANK/LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE W/ CLEAN MEDIUM SAND. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. ALL PIPING TO BE 4" SCH 40 O 1/8-/FT (UNLESS SPECIFIED) 15. INTERIOR PLUMBING TO BE COMBINED TO MEET PROPOSED OUTLET LOCATION AND ELEVATION. .�* OF o DARREN � 'i No.`1�140 SEPTIC SYSTEM PROFILE INV. ELEV.=7.75 END ELEV.=7.60 3 3/4a a/s. �1` Jtj DOUBLE WA-Vit_-n SMNE Ct BOTTOM EL.= 7.10 SEPARATION 5.00FT. BOTTOM OF TESTHOLE EL. 2.10 SOIL LOGS DATE: AUGUST 4, 2022 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH EI•v. TP-1 Depth 13.10 0 LOAMY SAND 0" tOYR 3/2 12.43 8" A LOAMY SAND IGYR 4/1 11.26 14" B LOAMY SAND tOYR 5/8 10.60 30" C PERC TEST FINE - O EL 8.77 MEDIUM SAND 2.5Y 6/4 2.10 132" PERC RATE <2 MIN/IN. (-C" HORIZON) NO GROUNDWATER OBSERVED • 1. Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. CMIEC Na 410 9" MIN COVER l BREAKOUT EL. = 8.08 SOIL ABSORPTION SYSTEM (SECTION) DESIGN CRITERIA NUMBER OF BEDROOMS: 4 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 4 OR = 440 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 440 gpd x 200% = 880 gpd, PROP. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (440)/0.74 = 594.59 S.F. USE 301 X 20'W LEACHING FIELD WITH 4 LATERALS BOTTOM AREA: 30 x 20 = 450 SF TOTAL SQUARE FEET PROVIDED = 600 vs. 594.59 REQ'D DESIGN FLOW PROVIDED: 0.74(600 S.F.) = 444 G.P.D. vs. 440 G.P.D. req'd PROPOSED SITE & SEPTIC SYSTEM UPGRADE PLAN 219 PLEASANT STREET, SO. YARMOUTH, MA Prepared for: James Modisette Design and Site Plan by: SCALE DRAWN DATE MEYER &SONS, INC. N.T.S. DMM 11/15/22 PO BOX 981 EAST SANOWICH, MA 02537 REV DATE: SHEET NO. 508362-2922 2 of 2