Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. /OS Lot S. 1 Zone of Contribution: In Out_ Acreage I?0 Commercial: ,/ Residential: Street: '2:7,-1- P v`.e_S .e e • t- w Village: ,p ar..e -k 6 L,ryt,� Floor Plan: #Beelreetns: ►SS-L1 CPC_ Owner: � Co a \SI 1LvvcA5 C;QUful,pstaller: R.0 e�--E- M. C)L)r (T - Address: C J-1 (,.3 i 11oLA)Stec.„ +t-fr0,- ,,1- Phone: (Sam 1---12 • Os- v Phone: CS-o-2:0 3t.o7 - N- Z-2 rt- Builder: Engineer: ►Nvl, --1-- „-, 00. eact y Address: Phone: (Svc ---7--I 1 - -15-0.2 Phone: N/A YES NO 1.Required#of copies received / 2.Date of soils exam and percolation test not older than 2 years V 1 3.4-5 ft of naturally occurring pervious material,above water table ,/ r��- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,� 5.Water line 10 ft from septic components Var.: N/ 6.Benchmark indicated and shown-NGVD if near wetlands ,/ 7. Septic tank minimum 10 ft from foundation, deck Var.: V/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: l 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,/ 11.Tank/leaching minimum 10 ft from property line Var.: ,/ 12. System meets all other setback requirements Var.: ‘/ 13.Uses adjustment for maximum high groundwater Var.: ,/ 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: / , 15. System not in top or subsoil(A,B horizons)or 5'removal / 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred ,/ 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal / 22. System adequately sized for its intended use ,✓ 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field / 26. Electrical permit for pump chamber/Separate meter for duplexes ,/ 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size f 28. Septic tank/pump chamber to be factory waterproofed v--- 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature J , 33.H-20 loading is subject to vehicular traffic,groundwater V 34.Title V Application and.permit fee,installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house I 36.Deed Restriction required max. #bedrooms: max. flow: gpd 3,,Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 4-11 vie, LA )/ry)`vLe,K 6 03 03 Y3CD1J N()i E Ti-0-1" -11-1-I Er. I,,: i