HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out Acreage
-) Commercial: Residential:
Street: 78 6 )) 4fe ---
Village: Floor Plan: # Bedrooms: ,.. 2__
Owner: Installer:
Address: ec, -�
Phone:
Phone:
Builder: Engineer: Kse i f1-\, --re 1 N 6..Pc-71:c_&
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received R/
2.Date of soils exam and percolation test not older than 2 years �/�
3.4-5 ft of naturally occurring pervious material, above water table a -----
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: Q/
5. Water line 10 ft from septic components Var.: I d�
6. Benchmark indicated and shown-NGVD if near wetlands �/
7. Septic tank minimum 10 ft from foundation, deck Var.: 9 ,, />'
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: v �;
9. Leaching minimum 100 ft from wetlands Var.: 7
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: V
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setbackrequirements Var.: 1��
13. Uses adjustment for maximum high groundwater Var.: , ' 5"y'
14. Leaching set 4-5 ft above adj. water or bottom of test hole • c/
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", %"preferred
18. System meets breakout requirements PVC liner: Wall: e/
19. Specified tee sizes are proper, gas baffle on outlet tee ,/
20. Sewage is under 10,000 gpd for parcel -
21.No garbage disposal I
22. System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade t/
25. Inspection port on plastic chambers/leach field V
26. Electrical permit for pump chamber/Separate meter for duplexes
L./
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size t
28. Septic tank/pump chamber to be factory waterproofed l�
29. Vent provided if leaching below 3 feet,under driveway/parking 1�
30. Buoyancy calculations for tank/pump chamber C.----
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater _/
34.Title V Application and permit fee,installer signature / „____„--"
35. Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by o:o:
c_.3 / -3'a3