HomeMy WebLinkAboutEngineer PlanGENERAL NOTES: A. CONTRACTOR SHALL NOTIFY "DIG -SAFE" AS REQUIRED PRIOR TO THE START OF ANY EXCAVATION WORK. CONTRACTOR IS RESPONSIBLE FOR PROTECTING UTILITIES WITHIN THE WORK AREA DURING CONSTRUCTION. B. CONTRACTOR TO VERIFY EXISTING CONDITIONS, INCLUDING ELEVATIONS OF EXISTING BUILDING SEWER, AND REPORT AND DISCREPANCIES TO THE DESIGN ENGINEER PRIOR TO THE SETTING Of ANY SEWAGE DISPOSAL SYSTEM COMPONENTS. C. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION. D. ALL CONSTRUCTION SHALL CONFORM TO THE STATE SANITARY REGULATIONS (310 CMR 15.00) AND ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. E. PROPERTY IS LOCATED WITHIN FLOOD ZONE AE EL=11 PER FEMA MAP PANEL 25001C0589J. SEWAGE DISPOSAL SYSTEM NOTES: 1. H-20 RATED COMPONENTS SHALL BE REQUIRED IN ANY AREAS SUBJECT TO VEHICULAR LOADING AND AS REQUIRED ON THE PLAN. 2. THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS CONSTRUCTED AS SHOWN. ANY CHANGES OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING. 3. ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED, THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL BE 0.01 FT/FT. 4. SOIL ABSORPTION SYSTEMS MUST BE VENTED WHEN DISTRIBUTION LINES EXCEED 50 FEET IN LENGTH, WHEN LOCATED IN AREAS SUBJECT TO VEHICULAR LOADING, AND WHEN PRESSURE DOSED. 5. FINISHED GRADE SHALL BE A MAXIMUM OF 36" AND A MINIMUM OF 9" OVER THE TOP OF ALL SAW CUT EXISTING SIDEWALK SYSTEM COMPONENTS. (SEE NOTE #12) 6. ALL SEPTIC SYSTEM COMPONENTS, FOR UNIT #2, SHALL BE PUMPED DRY REMOVED, AND AREA FILLED IN WITH CLEAN SAND. 7. CONTRACTOR SHALL PROTECT ALL EXISTING SEPTIC COMPONENTS FOR UNIT #1. CONTRACTOR SHALL EXPOSE THE EXISTING LINE FROM THE SEPTIC TANK TO LEACH PIT, PRIOR TO THE INSTALLATION OF ANY NEW SEPTIC COMPONENTS, TO CONFIRM THERE ARE NO CONFUCTS WITH THE NEWLY PROPOSED SEPTIC INSTALLATION. IF THE EXISTING LINE IS IN CONFLICT WITH THE PROPOSED SEPTIC DESIGN THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND LINE WILL BE RELOCATED AS NEEDED. EXISTING HEDGE AND TREE 8. COMPONENTS TO BE PROVIDE WITH WATERTIGHT ACCESS COVERS RAISED TO WITHIN 6" Of TO BE REMOVED GRADE WHERE REQUIRED. 9. PRIOR TO FINAL INSPECTION BY THE ENGINEER AND THE BOARD OF HEALTH ALL SYSTEM COMPONENTS MUST BE INSTALLED INCLUDING ALL ACCESS COVERS WITH RISERS. 10. SOIL REMOVAL: ALL FILL AND SUBSOIL (B LAYER) SHALL BE REMOVED FROM THE FOOTPRINT WORK AREA PLAN OF THE LEACH FIELD ONLY (PER YARMOUTH BOARD OF HEALTH REQUIREMENTS) DOWN TO THE SCALE: 1" = 10' CLEAN SAND LAYER, LAYER Cl, APPROX. 33" BELOW GRADE. AREA TO BE BACKFILLED WITH CLEAN "TITLE 5" SAND AND COMPACTED TO MINIMIZE SETTLING. CONTRACTOR TO NOTIFY TOWN AND/OR ENGINEER TO VERIFY SOIL REMOVAL AS REQUIRED. 0 10 20 30 11. PROPOSED LINER: INSTALL A 40 mil HDPE LINER FROM EL=8.7t TO EL=8.0 AS SHOWN ON PLAN AND SAS DETAIL. SCALE 1 "=10' 12. EXISTING SIDEWALK TO BE PROTECTED DURING CONSTRUCTION. IF SIDEWALK IS DISTURBED IT SHALL BE SAW CUT AND AREAS DISTURBED REMOVED. SIDEWALK SHALL BE REINSTALLED WITH AN 8" PROCESSED GRAVEL SUBBASE AND PAVED WITH 3" (DONE IN TWO 1.5" LIFTS) USING MASSOOT #9.5 ASPHALT JOB MIX FORMULA 13. EXISTING PARKING LOT TO BE SAW CUT AND REMOVED AS NEEDED FOR SEPTIC INSTALL. PARKING LOT SHALL BE REINSTALLED WITH AN 8" PROCESSED GRAVEL SUBBASE AND PAVED WITH 3" (DONE IN TWO 1.5" LIFTS) USING MASSDOT #12.5 ASPHALT JOB MIX FORMULA 14. PROPOSED 2" FORCE MAIN TO BE INSTALLED AS SHOWN ON THE PLAN TO ALLOW FOR FUTURE INSTALLATION OF LEACHING FIELD FOR UNIT #2. PUMP NOTES & REQUIREMENTS: 1.) ALARM SHALL BE A RED WARNING LIGHT WITH AUDIBLE ALARM LOCATED WITHIN THE BUILDING AS SHOWN ON THE PLAN. 2.) THE CORDS FOR THE FLOATS SHALL BE ONE CONTINUOUS PIECE FROM THE PUMP CHAMBER TO THE DISCONNECT PULL BOX. THE CORDS SHALL BE ENCASED IN 3" ELECTRICAL CONDUIT. 3.) ALARM AND PUMP TO BE WIRED TO DIFFERENT CIRCUITS. 4.) ALL PUMP, WIRING, ALARM, AND FLOAT INSTALLATIONS SHALL CONFORM TO MASSACHUSETTS STATE PLUMBING AND MASSACHUSETTS STATE ELECTRICAL CODES AS WELL AS TO MANUFACTURER'S SPECIFICATIONS. 5.) PUMP SHALL BE LIBERTY LE41A SERIES T� PUMP (OR EQUAL) MEETING MAXIMUM REQUIREMENTS OF 19.9 GPM AND 10' OF TOTAL DYNAMIC HEAD, INSTALLER TO VERIFY PUMP WITH MANUFACTURER FOR FLOW AND TDH. 6.) 28 J"" FROM PUMP ON FLOAT TO INLET INVERT PROVIDES 323 GALLONS OF STORAGE. PUMP DOSING CALCULATIONS: 1. DETERMINE VOLUME OF EFFLUENT TO BE PUMPED TO LEACHING PROPOSED FLOW BARRIER J FI ELD: (SEE NOTE #11) DAILY FLOW = 220 GAL NUMBER OF DOSES PE AY = 10 DOSES" PERFORATIONS NUMBER OF GALLONS Y /10 = 22 GPD W/ ORENCO SHIELDS DRAIN BACK VOLUME: 2" FORCE MAIN = 14 GALLONS 5' SOIL REMOVAL PUMPING VOLUME = DOSING VOLUME + DRAIN BACK VOLUME (SEE NOTE #10) PUMPING VOLUME = 33 GALLONS + 14 GALLONS = 47 GALLONS (min) 2. DISCHARGE RATE: 17 TOTAL PERFORATIONS (INCLUDING VENTS) x 1.17 GPM / PERF. ® PROPOSED INSPECTION PORT 2.5' HEAD = 19.9 GPM 3. TOTAL DYNAMIC HEAD: 10 FT. 4. PUMP MUST BE CAPABLE OF PUMPING AT LEAST 19.9 GPM PROPOSED VENT --"" AGAINST A TOTAL DYNAMIC HEAD OF 10 FT SCHEMATIC FLOW PROFILE: INOT TO SCALE RAISE COVER TO GRADE WITH MIN. 24" - POLYLOK HEAVY DUTY (SCREW DOWN WITH GASKET) AND A RAISE COVER MIN 24" PLASTIC RISER TO WITHIN 6" OF / FINISH GRADE -7 FINISH GRADE=10.5t 9.5f Check Valve DROP: 2' min. Gate Valve 3" max. 3/8" Bleeder 10" 48" GAS BAFFLE Hole *B.Ot *SEE NOTE 7.75 3.3t PROPOSED 2000 GALLON LOW PROFILE 2 COMPARTMENT SEPTIC TANK/PUMP CHAMBER (H-20) TANK SHALL BE WATERPROOFED ON THE OUTSIDE SAS DETAIL DEEP OBSERVATION HOLE LOGS NO SCALE DEEP OBSERVATION HOLE 1 EL. = 9.0t DEPTH FROM SURFACE SOIL HORIZON SOIL TEXTURE SOIL COLOR MUNSELL 0" - 20" FILL - - - - - - 20" - 33" B LOAMY SAND 10 YR 5/8 33" - 100° C1 MEO-COARSE 10 YR 8/6 SAND DATE OF TESTING: 11 /2/22 PERCOLATION RATE: LESS THAN 2 MIN/INCH (PERC IN C1 LAYER IN TP#1) WITNESSED BY: KEITH E. FERNANDES, PE, DIG -IT CONSTRUCTION, LLC. JAY GARDINER, ASSISTANT HEALTH DIRECTOR, YARMOUTH HEALTH DEPARTMENT GROUNDWATER STANDING @ 88" BELOW GRADE (EL=1.67) IN TP#1 USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM. PROPERTY LINE INFO: 1. PROPERTY LINES AND BUILDING LOCATIONS PER CONDO SITE PLAN DATED 7/31 /1981 ON FILE AT THE BARNSTABLE COUNTY REGISTRY OF DEEDS. EXISTING SEPTIC INFO: 1. EXISTING SEPTIC COMPONENTS FOR LOTS 2-10 PER PLAN BY BSC GROUP DATED 9/25/2014 ON FILE AT THE YARMOUTH BOARD OF HEALTH. 2. EXISTING SEPTIC COMPONENTS FOR UNIT #1 PER SEPTIC INSPECTION REPORT DATED 1-25-16 BY B&B EXCAVATION ON FILE AT THE YARMOUTH BOARD OF HEALTH. TIMBERS SHALL BE INSTALLED SO BUTT JOINTS ON LOWER ROW ARE OVERLAPPED BY TIMBERS ON TOP ROW -8" LONG TIMBER LOCK SCREWS DETAIL OF VENT ACCESS CAP INSTALLED 2' ON CENTER AND WITHIN 1' OF ENDS/OVERLAPS NOT TO SCALE _---PROPOSED 6" X 6" TIMBER WALL (3) ROWS ABOVE GRADE Finish Grade 7PROPOSED 6" X 6" TIMBER SOLDIERS TO BE INSTALLED -8- ON CENTER (MAX), WITHIN 2' 4" DIA. NDS ROUND OF CORNERS, AND OF 2.5' BELOW IRRIGATION BOX COVER GRADE (MIN). SEE DETAIL FOR LOCATION. 1" Screw -on Cap in I 1" PVC Access Pipe {� I N PERFORATED PIPE CONNECTED TO VENT LINE SCALE 1" =20' & CAP BY "SWEET AIR" (MUSHROOM CAP) EXISTING GRADE 2" MANIFOLD \ J �I N (1) ROW OF TIMBERS TO BE BURIED BELOW GRADE CT AS IJ I I I NUMBER PERFORATIONS PER LATERAL = I I I 2) OUTSIDE LATERALS NTH 6 (INCLUDING VENT) I u? I � 1) MIDDLE LATERAL WITH 5 (INCLUDING VENT) PERFORATION SIZE = 1/4" I I N PERFORATION SPACING = SEE SAS DETAIL I I v: LATERAL LENGTH = 25' I I'cr I NUMBER OF LATERALS =3 I u? LATERAL DIAMETER = 1" WORK AREA PLAN SCALE: 1 " = 10' PROPOSED FORCE MAIN (SEE NOTE #14) BENCHMARK Gott CUGt CL CATCH or�tie 9 �� BASIN RIM V et\co\ de�o\k EL = 8.2t f a ore (NAVD88) TP 1 2.6't Existing Septic Components - UNIT #2 (See Note#6) O fa t i \ d P otk�r9 /� p o`je / ROOM ER PROPOSED TIMBER \ - 2 PREP 1� \ WALL \ PRO GPa PROPOSED SEPTIC N rn' TANK/PUMP CHAMBER Existing Septic Components - UNIT #1 // 2 (See Note#7) vN\� Cn � \ I I ✓ 18.2 f vN\� P� SP PGE; vOs OR <SNP� I X tz U 0 ik Y'r �a�er �i PROPOSED SEPTIC TANK TIMBER WALL LAYOUT TIMBER WALL SCALE 1 " =10' ST - TOP OF WALL EL=10.5t PROPOSED GRADE • PROPOSED ° TIMBER "SOLDIER" \A- �o PASSIVE VENT LINES: THREE (25't) OF SCHEDULE 40 3/4"-1-1/2" Stone Base Fill 1" Dist teral SYSTEM DESIGN CALCULATIONS: DESIGN FLOW: EXISTING 2 BEDROOM DWELLING AT 110 GAL. PER DAY PER BEDROOM = 220 GPD 220 GPD X 200% = 440 GALLONS - USE 2000 (2) COMPARTMENT MONO SEPTIC TANK/PUMP CHAMBER (1500 GALLON SEPTIC TANK do 500 PUMP CHAMBER) SAS AREA: A 25' L. X 12' W. X 0.5' D. LEACHING FIELD CAN LEACH: Vt = [(25 X 12)] X 0.74 GPD/SF = 222 GPD A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN. INSTALL: ONE (1) - 2000 GALLON LOW PROFILE SEPTIC TANK/PUMP CHAMBER (USE ACME/SHOREY STPC202LP) TANK SHALL BE WATERPROOFED ON THE EXTERIOR ONE (1) - 25' X 12' X 0.5' LEACHING FIELD ONE (1) - LIBERTY LE41A 4/10HP PUMP WITH CONTROL PANEL, FLOATS, AND ALARM ENTIRE PROPERTY IS LOCATED WITHIN AN AE FLOOD ZONE (EL-11) PER FEMA MAP PANEL 25001C0589J KEY MAP SCALE: 1 " = 30' 7, 1/4" Vent Hole with "ORENCO" Shield 90' Bend IT,� /4" Perforation with "ORENCO" Shield Leach Field I II PERFORATIONS 0 ORENCO SHIELDS INSTALLED (O O CLOCK OVER THEM ANDHAVESECTION A -A' CROSS-SECTION OF DELIVERY LINE / MANIFOLD CONNECTION > I I I NOT TO SCALE 4" PVC PERFORATED VENT PIPE (TYPICAL) LT: I PERFORATION AT VENT ACCESS CAP (SEE DETAIL) 4" SCH. 40 PVC 4" Sch. 40 PVC Vent Pipe INSPECTION PORT (Passive Vent) by "Sweet Air" W/ 18" PIECE OF #4 REBAR 4' 2 RAISE TO WITHIN 3" OF GRADE Vent Access Cap 2' 4' at end of each Lateral PIPE SHALL BE PERFORATED A(SEE DETAIL) I- 12 WITHIN FIELD 2" MANIFOLD, CAPPED END Proposed EL=9.5 (min) `�t \c° 3„ I�I min 1" Distribution Laterals 9 Proposed 2" Manifold to be below 8.7t (9' Min - 36" Max) lateral invert as shown. I �\/�THRUST BLOCKS TO BE INSTALLED AT EVERY BEND �2" Delivery Line Pitch 2" dia. Force Main tz Back to the Pump Chamber CLASS 150 Pressure Pipe with Pitch 2" dia. 1 CF of concrete behind bends for Force Main thrust blocking (Typical) Back to the Pump Chamber 78'f LAYER OF FILTER FABRIC �------------ - --------------- ; --I ------------- 6„ ; i i 3/4„ - 1-1/2" STONE A 7.8f t 25' Distribution Lateral *4.1't - *SEE VARIANCE REQUEST ONE (1) 25' x 12' x 0.5' V-EL=3.7f ESTIMATED SEASONAL HIGH LEACH FIELD • ,0' GROUNDWATER - PER VARIANCE REQUEST 2" Delivery Line to 2" Manifold-i-V-EL=1.7t OBSERVED GROUNDWATER (3) 1" Laterals with 1/4" Burr -free Perforations I(see IN TEST PIT #1 11/2/2022 SAS detail for spacing) Drilled at the 11: 00 and 1: 00 positions Each 1/4" Perforation Capped with "ORENCO" Splash Guard 1/4" Vent Holes drilled below 90' bend at each end of each Lateral (3) 1 PVC DISTRIBUTION LA RALS (TYPICAL) )YANCY CALCULATIONS: 2000 GALLON SEPTIC TANK/PUMP CHAMBER Fe� _ (13' X 7' X 0.9') 62.4 LB/CF (Based On Estimated Seasonal High Groundwater EL=4.2) 5,111 Ibs Fw = TANK WEIGHT + SOIL COVER =33.500 Ibs. (Per. Spec) Fwf = 33,500 Ibs >f Fe = 5,111 Ibs HIGH GROUNDWATER LEVEL CALCULATION DEPTH TC WATER TABLE (11/2/2022) EL=1.67 APPROPRIATE INDEX WELL: MIW-29 WATER LEVEL RANGE ZONE: A (0-2) CURRENT DEPTH TO WATER LEVEL (11/2022): 9.4 WATER LEVEL ADJUSTMENT: *2S' *SEE VARIANCE REQUEST ESTIMATED DEPTH TO WATER LEVEL: EL=4.2t Z ;O) \ SPS , SPS#p "\ `- �N��� FLOOR PLANS: SR� o /`. 1. FLOOR PLANS TO BE PROVIDED SEPARATELY. JAPE! 3 0 2023 HEALTH DEPT. PUMP CHAMBER FLOAT DETAIL NOT TO SCALE OUTLET INVERT EL=7.75 Storage Volume ----Alarm (28-3/4" = 323 Gallons) 6" Pump On 0 1 OVER THE COUNTER VARIANCE REQUEST LOCAL UPGRADE APPROVALS: 310 CMR 15.403 VARIANCE: 310 CMR 15.212 -1b (Depth to Groundwater) 1.) Separation from bottom of Leach Field to High Groundwater not 5' 4' held 1' variance VARIANCE: 310 CMR 15.252: - 2F 1.) Separation from Leach Field to Existing Leach Pit not 10' 9' held 1' variance VARIANCE: 310 CMR 15.103: - 3b3 1.) Reduction in Estimated Seasonal High Groundwater Adjustment - 2.5' Required 2' held 0.5' variance 48" Cycle Volume (4-1 /4 = 4ti Gallons) Pump ON/OFF 15" Sump ZN 0FA3so KEITH E. yc oFERtJANDES a c5 CIVIL PUMP FLOAT NOTES: N°72 0 �Q QISTEP SIONAL jO 1. FLOATS SHALL BE SECURED TO THE DISCHARGE LINE, f INSTALLED ON A FLOAT TREE, OR PROVIDED WITH A 4- CABLE WEIGHT. ��2 103 2. FLOATS SHALL BE INSTALLED SO THAT THEY ARE ACCESSIBLE FROM THE OUTLET MANHOLE COVER. REVISED 1/19/23: VARIANCE ADDED & UNIT 2 SAS FOOTPRINT ADDED -' " DIG -IT 4, CONSTRUCTION, LLC s7 PO BOX 268 SOUTH DENNIS, MA 02660 PHONE: 508-432-1635 www.digitconstructionIIc.com CLIENT: 785 ROUTE 28 LLC 176 SUDBURY LANE HYANNIS, MA 02601 A_i:.._ i-L.-\ -701 A -70c n-..L- na V---.., L-\ r+An\ ni---\ -7ni A CAC onn in nz a