Loading...
HomeMy WebLinkAboutEngineer PlanTOP \26.5 * V! F ACCESS COVERS TO WITHIN 6® OF FIN. GRADE 29.1' F287. MINlutlu 75llnr nnvrp rivro PorelACT (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM [.�� U BLOCKS no PRECAST H-10 WATERTEST D'BOX FOR LEVELNL55 MIN2" WALL THICKNESS PRECAST RISERS RISERS CrYP.) 2*0 . 4"OSCH40 PVC MORTAR ALL INVERT IN 25.2' L PIPES LEVEL 1ST 2' 4 rlSIDES COMPONENTS (Typ.) 4'— ENDS 26 D1' 10- 1500 GAL H-10 14* TEE SEPTIC TAN K TEE \Z5�85 r U—C 0 Milli. SUMP 0- . 0-0 ._._0 6 MIN 0 0 0 0 0 o �j m 1B, R poplin as 0 �050 GAS BAFFLd' 0 _ _ 0 0 M 0 0 ?0_. 0_0 12 I� 12" MIN. INT. DIM. REP 1010 ,:14 UQ. LEVEL (ACME OR EQUAL) 25.47' 3 70.- 0 00, H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUA 3/4--1-1/2" DOUBLE WASHED STONE 4� MIN. (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00, X 12.83' COMPACTION. (15.221 [21) 7 (--L% SLOPE)MIN. (--!—% SLOPE) (—!—% SLOPE) FOUNDATION— 20' SEPTIC TANK — 38' D' BOX 12' LEACHING FACILITY 18.2' BOTTOM TH-1 NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- 99 -- EXISTING CONTOUR X 99-1 EXIST. SPOT ELEV. —[99}— PROPOSED CONTOUR 198-41 PROPOSED SPOT EL. TH1 ii� TEST HOLE 2% SLOPE OF GROUND UTILITY POLE FIRE HYDRANT WM NOT ALL SYMBOLS MAY APPEAR IN DRAVIING IN a ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: JAY GARDINER DATE:12/14/22 PERC. RATE < 2 MIN INCH CLASS SOILS IT] ELEV. 28.2' A LS 7" 1 OYR 4/3 B LS 24"1 1 OYR 5/6 26.2' C PERC X MS 2.5Y 6/4 LICE #22-368 t7 tLj NOTE: ADDITIONAL CESSPOOLS NOT SHOWN ON ASBUILT COULD BE PRESENT. Scale: 1 20' 4C _EE i S f;Q f NOTES 1. DATUM IS NAYD—dE 2. MUNICIPAL WATER IS EXISTING ROU te �Loqug, 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. JIN��i5 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. I 01 oy 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR Z CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENTOF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 36 PARCEL 21 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. wommom— yarmouth Health Department ROVED a /-.e? zf Date SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: -3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = _660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2_J.74) :!!_112 GPD BOTTOM 25 x 12.83 (174) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE 8130tDOF HEA H TITLE 5 SITE PLAN OF 47 WENDWARD WAY JAN 2 7 2023 YARMOUTH, MA HEALTH DEPT. PREPARED FOR BORTOLOTTI CONSTRUCTION MURPHY 1 -7- DATE DANIEL A. OJALA, P.E., P.L.S. DATE: DECEMBER 22, 2022 off 508-362-4541 fax 508-362-9880 downcape.com @ uowa cove ea hieerint, h7or. I civil engineers land surveyors 939 Main Street ( Rte 6A) YARIWOUTHPORT MA 02675 22-368 80RT0LCTT:-MURPHY.DWG