HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 102.0't
fFINISHED GRADE
@ FOUNDATION = 101.2t
PROP. SCH. 40
PVC SEWER
27't
yU.4 2
(corner 4e -1
*98.9'±
97.75'-j
PROPOSED EXTENSION RISER
WITH COVER OVER INLET &
OUTLET TO WITHIN 6" OF F.G.
21" MIN. ACCESS
COVER (TYP.)-\
6� 3„ 2" DROP MIN. r -
3" DROP MAX. 3" 9"
13"
14"
INLET TEE
48"
TEES TO BE CENTERED
DIRECTLY UNDER RISERS
F.G. OVER TANK EL.= 100.4't
9" MIN.
36" MAX.
PROP. SCH. 40
PVC SEWER
MIN SLOPE @ 1
\��N__97.50'
OUTLET TEE
GAS BAFFLE
23.9' OFFSET TO FND
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE Q C
PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK
LENGTH 10'-6' WIDTH 5'-8" DEPTH 51-811
*CONTRACTOR TO VERIFY EXISTING: (Dimensions per
ELEVATION PRIOR TO ANY WORK & SEPTIC T A INO V D P O F I L E ACME/Shorey)
NOTIFY ENGINEER IF DIFFERENT, NOT TO SCALE
SWING -TIES
DESCRIPTION
HC-1
HC-2
HC-3
TANK COVER IN (1)
47.6'
25.3'
27.8'
TANK COVER OUT (2)
54.7'
33.3'
35.3'
CORNER OF STONE (3)
44.1'
25.4'
31.9'
CORNER OF STONE (4)
68.0'
50.2'
53.7'
CORNER OF STONE (5)
66.V
53.0'
59.7'
CORNER OF STONE (6)
41.2'
30.6'
PROPOSED
DISTRIBUTION BOX
1
500,
CI
MAI
LOl
x100.3
PROPOSED
GALLON SEPTIC 1
NOTES:
1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF
EACH SEPTIC SYSTEM COMPONENT.
2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT
DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF
HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA.
3. PROPERTY IS NOT LOCATED WITHIN A DEP APPROVED ZONE II.
4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY
FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS
IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL
NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT.
FINISH GRADE OVER D-BOX=100.3't -
REMOVABLE WATER -TIGHT COVER OVER
RISER TO WITHIN 6" OF FINISHED GRADE
r5" DIA. OUTLET(S)
9" MIN,
36" MAX.
L=5't
PROVIDE WATERTIGHT
4" PVC IN FROM JOINTS (TYP.)
SEPTIC TANK O 4" PVC OUT TO
LEACHING FACILITY
12" 6"
97.40' MIN. 97.23'
6" CRUSHED STONE
OVER MECHANICALLY
COMPACTED BASE
5 OUTLET DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE
BASE. FIRST TWO FEET OF OUTLET
PIPES TO BE LAID LEVEL.
CROSS SECTION VIEW
DI ,'-rl . L)ETAIL
NOT TO SCALE
- 4" SCHEDULE 40 PVC
MIN SLOPE 1%
t
9" MIN.
97.10' 36" MAX.
FINISH GRADE OVER CHAMBERS = 99.9' - 100.3'
SLOPE @ 2% MIN. OVER SYSTEM
TOP OF SAS = 97.93'
BREAKOUT EL = 97.60' - ,,
0
0
0
0
��
00
00
2'
4.0' ` - 8.5' (TYP)
95.10'
25.0
GROUND WATER ELEV=
0 �
0 0C:
o0
0
i
(` f= NJ I = P A I N
3/4" TO 1-1/2" DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES.
STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
- DESIGN ENGINEER.
PLACE RISER ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
INLETS TO WITHIN 6"
CHAMBERS PIPED SYSTEM UNLESS OTHERWISE NOTED.
OF FINISHED GRADE 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
ELEVATION = 97.60' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A
40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
So`b�
O
�I
THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
0
5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM.
0�
o
6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
o
�I
o0
7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK
pCDC)
000
o
oo
FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
4.0'
4.0'
8. ELEVATIONS BASED ON APPROXIMATE ASSUMED DATUM. SEE BENCHMARK LOCATION AND
-4.83
(TYP.)
ELEVATION SHOWN ON PLAN.
9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
12 83'
THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
\-5' MIN.
GALLON CHAIVlbtK, CHAMBER EfNU VILE
1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
TO THE DESIGN ENGINEER.
1400
GAL CHAMBER PROFILE
C
HAI`
n
� �., � � ,� �
TAILS
10.
ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT.
NOT TO SCALE
11.
NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING
TEST PIT
r)ATA
REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM
% • ' t / •.% �1'
• •
APPROPRIATE AUTHORITY.
�'• C
'•.� %••' �•�J;
PERC NO. N/A
12.
ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
r: �+ •; t' '• �� �
��
INSPECTOR: Bruce Murphy (BOH)
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
• • • ' L `-------
ary
__ _ _ EVALUATOR: Michael Pimentel, EIT, CSE
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
" • • + '+• ' O t • B
20
f �-
C.S.E. APPROVAL DATE: Oct. 27 1999
13.
DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
•. . • . _�� to "' f
I DATE: December 29, 2022
14.
WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
' • ++ • ' +' ' f�'�y/
TEST PIT #: 1
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
••
I , • . �1 �� j
REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
• • '••». ,� �,//�`� P 't- `-�
- • •.
ELEV TOP = 99.90'
FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
•` -'•.
a
r -
/ ELEV WATER = < 88.90'
15.
CONTRACTOR SHALL NOTIFY DESIGN ENGINEER F ADISCREPANCIESF
E O NY FOUND IN
t
�,,•jtQ
�,• .
y !
�•,<
PERC RATE _ < 2 min./inch
SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
A
! . - - -- - -
16.
PROPOSED PROJECT IS LOCATED WITHIN:
DEPTH OF PERC = 30" - 48"
ASSESSOR'S MAP 22 LOT 368
C
\ TEXTURAL CLASS: I
OWNER OF RECORD: KEVIN B. O'BRIEN
ADDRESS: 68 BEECH STREET
PALMER, MA 01069
0"
d
99.90'
PIeWOi
I
LOCUS
`Loamy
o10Yr 4/1
FEMA FLOOD ZONE X
811
99.23
COMMUNITY PANEL # 25001CO588J
�
1(c
B
Loam Sand
10Yr 5/8
17.
DEED REFERENCE: BOOK 8009, PAGE 72
1
18.
PLAN REFERENCES: 1.) PLAN BOOK 25, PAGE 47 2.) PLAN BOOK 77, PAGE 51
30"
97.40'
CV
m
\ �Engtewood
`�-�
O`
Perc
19.
ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
Beach
r,� 48'
95.90'
20.
PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY
I i •'~
7' •���
FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
•��'-
M
FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
21.
OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
Med. to Fine
REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
88.90'
Observed
50xO'
--- 50 -
50
50
O O O
JAN 17 2023 0
HEA1.TH DEPT.
REV. 1 DATE
OF Mqrt
qC'y
= JOHN L.
CHURC LL JR.
C L '^
NO.. 8066
\sl !ST
��t� of Ss
ti
JOHN L. GNP
CHURCHILL JR.
CIVIL y
\ NO.A1807 /
Yarmouth Health Department
PROYED�
r
name j Date
EXISTING SPOT GRADE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED SPOT GRADE
EXISTING GAS LINE
EXISTING OVER HEAD WIRES
EXISTING WATER LINE
TEST PIT LOCATION
PROPOSED 1,500 GALLON SEPTIC TANK
PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
PROPOSED DISTRIBUTION BOX
PROPOSED 500 GALLON LEACHING CHAMBER
BY I APP'D. I DESCRIPTION
PROPOSED SEPTIC SYSTEM UPGRADE
PREPARED FOR
ROBERT B. OUR CO., INC.
LOCATED AT
35 MAINE AVENUE
WEST YARMOUTH, MA
SCALE: 1 INCH = 10 FT. DATE: JANUARY 12, 2023
0 5 10 20 40 FEET
PREPARED BY
JC ENGINEERING, INC.
2854 CRANBERRY HIGHWAY
EAST WAREHAM, MA 02538
508.273.0377
Drawn By: MKV Designed By: MKV Checked By: MCP JOB No. 6738