Loading...
HomeMy WebLinkAbout2022 Sign off Transmittal - New 3 bdrm home ot.:Y i,, , TOWN OF YARMOUTH , ;24„t Arc, HEALTH DEPARTMENT PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET To he completed by Applicant. Building Site Location: Y-5C 44 1E- h A -Z-i Proposed Improvement: tJr<.i c CC�kl'p t&c ' 1.r \` "c1,.-1 I ??IaifecePt 2. Applicant: 71 pu r —sc rc"c ti;./cl i,,. L, L C Tel. No.: C<`\. (' C ' I n Address: T.) 070,7 3 ti car v7 Z r A \3,- /� C 4' "'.5Z Date Filed: I 1 Ifir�e-Z**/f you would like e-mail- notification of sign off please provide e-mail address: c c V C (C TV r'�'r'Se p ro'�fr i'e.3 , C C-.1."Owner Name: 7vri,,,, -l. i,t-,,p( 4` S L i C Owner Address: ''C C-Sc( "5-1�`'( 3 '17oceic Cry V`tdf C'%` 57 Owner Tel. No.C(- r --`(96) RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans, to include: (1.) Site Plan showing existing buildings, water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed) — Note: Floor plans not required for decks, sheds, windows, roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY: CJr--,- C . DATE: 0 - �/ ' L N .) e Lc) t� ��"".. PLEASE NOTE c COMMENTS/CONDITIONS: m GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS, SIZES OF EXISTING FRAMING MEMBERS AND BEAMS, EXISTING WINDOWS AND DOOR SIZES SHOULD BE VERIFIED. NEW AND EXISTING FLOOR RIDGE, GUTTER, FASCIA AND GRADING CONDITIONS SHOULD BE VERIFIED. ALL VERIFICATIONS MUST BE DONE BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK OR ORDERING OF MATERIALS. 2. ALL WORK SHALL CONFORM WITH BOTH STATE AND LOCAL GOVERNING CODES. 3. ALL WORK SHALL BE COMPLETED TO THE OWNER'S SATISFACTION. 4. IT IS NOT THE INTENT OF THESE PLANS TO SHOW ALL FASTENING DEVICES OR FRAMING TECHNIQUES NOR ALL EXISTING "CONCEALED" CONDITIONS. 5. ALL CONSTRUCTION RELATED DEBRIS SHOULD BE PERIODICALLY AND COMPLETELY REMOVED FROM THE SITE. 6. FLASHING AND COUNTER FLASHING IS REQUIRED AT ALL ROOM INTERSECTIONS AND VALLEYS, DOOR AND WINDOW OPENINGS AND ALL OTHER PENETRATIONS THROUGH THE ROOFS OR THE SIDE WALLS. 7. CONTRACTOR SHOULD VISIT THE SITE PRIOR TO SUBMITTING A BID. 8. CONTRACTOR SHALL PAY FOR ALL PERMITS AND RELATED FEES. 9. CONTRACTOR IS RESPONSIBLE FOR STAKING OUT THE BUILDING IN ACCORDANCE WITH THE OWNER'S SURVEY AND THE SITE PLAN. ANY DEVIATION OR PROBLEM SHOULD BE REPORTED TO THE DESIGNER PRIOR TO EXCAVATION. ALL WINDOWS SHALL BE MANUFACTURED BY ANDERSEN CORPORATION (OR EQUAL). ALL WINDOWS SHALL BE FURNISHED WITH HIGH PERFORMANCE GLASS DOUBLE INSULATED GLASS. HORIZONTAL WEATHER STRIP INSTALLED ON TOP RAIL, CHECK RAIL, AND BOTTOM RAIL. ALL WINDOWS SHALL BE THE SIZE LISTED ON THE WORKING DRAWINGS. 10. THE CONTRACTOR SHALL COORDINATE THE WORK OF THE PLUMBING, ELECTRICAL AND HEATING SUBCONTRACTORS. 11. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR THE PERIOD OF ONE YEAR AFTER THE FINAL ACCEPTANCE OF THE CONSTRUCTION. 12. ALL CASINGS AND TRIM ON THE EXTERIOR SHALL MATCH IN DESIGN THE EXISTING DETAIL. THE PAINTING, GUTTERS, DOWNSPOUTS, CLAPBOARDS, AND SHINGLES SHOULD ALSO MATCH AND BLEND WITH EXISTING STRUCTURE UNLESS OTHERWISE DIRECTED. 13. THE CONTRACTOR SHOULD PROVIDE ADEQUATE BRACING SHORING OF ALL WORK AS REQUIRED AND PROVIDE SAFETY AND WEATHER PROTECTION TO PREVENT ANY DAMAGE TO THE EXISTING INTERIOR WORK SCHEDULED TO REMAIN. 14. ALL FINAL INTERIOR FINISHES TO BE SELECTED BY THE OWNER. 15. ALL INTERIOR WALLS AND CEILINGS TO BE 1/2" BLUEBOARD WITH SKIM COAT FINISH APPLIED TO OBTAIN A SMOOTH MONOLITHIC SURFACE READY TO RECEIVE FINAL FINISHES. IF NOT SPECIFIED OTHERWISE PREPARE SURFACES WITH ONE COAT OF PRIME AND TWO COATS OF PAINT. 16. HEATING, VENTILATING, PLUMBING AND ELECTRICAL SYSTEMS SHOULD BE INCLUDED IN THIS CONTRACT. ALL EXISTING SYSTEMS SHOULD BE MODIFIED AND EXTEND TO INCLUDE THE NEW ADDITION. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INCLUDE THIS PHASE OF THE PROJECT IN HIS WORK AND TO COORDINATE ALL SUBCONTRACTORS AS REQUIRED. ALL MECHANICAL AND ELECTRICAL SUBCONTRACTORS MUST SECURE PERMITS AND APPROVALS AT APPROPRIATE PHASES OF THE WORK. 17. GENERAL CONTRACTOR SHALL NOTIFY DIG -SAFE FOR LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION. 18. ELECTRICAL CONTRACTOR TO COORDINATE WITH OWNER FOR LOCATIONS AND QUANTITIES OF ALL NEW AND RELOCATED ELECTRICAL ITEMS SUCH AS: DUPLEX OUTLETS (INTERIOR AND EXTERIOR), GFI'S, TELEPHONE JACKS, COMPUTER STATIONS, T.V CONNECTIONS, LIGHTING (INTERIOR AND EXTERIOR), SWITCHING ETC.. 0 a- N First Floor Plan - +/- 871 sf SCALE 1/4" = 1'-0" THE GOVERNING CODE FOR THE DESIGN OF THIS BULDING IS THE 2015 IRC WITH MASSACHUSETTS AMENDMENTS (9TH EDITION) ,Keynote Architecture 45 POWHATTAN DRIVE EAST TAUNTON, MA 02718 Tel. (617) 690-7778 keynote_architecture@comcast.net IIRCNIfE=/E=NEER STAMP 0,,IN OF M,4 ADAM R. TADDONI4 m, 00 CIVIL r; No, 54170 9FG/STEP����C'Q ADO � ESS/ONAL ENG Adam R. Taddonio 16:15:30-04'00' 0 ISS FOR CONSTRUCTION No. Revision/Issue Date PROPOSED PLANS FOR: REPURPOSE PROPERTIES 135 HIGHBANK STREET SOUTH YARMOUTH, MA SHWmnE FIRST FLOOR PLAN NOTES Nov 14 2022 MEAUTI H DEPT. PROJECT SHIM A 1 . 1 WE OCTOBER 19, 2022 SOME AS INDICATED W___ Second Floor Plan - +/- 681 sf SCALE 1/4" = 1'-0" Keynote Architecture 45 POWHATTAN DRIVE EAST TAUNTON, MA 02718 Tel. (617) 690-7778 keynote_architecture@comcast.net ARCHRECT/EWNEER STAMP OF Pr}gSs�e o� ADAM g TADDONIO o CIVIL 4y', No. 54170 FSSfONAI Adam R.Taddonio //lam C/'��"' ✓'— 2022.1 1.01 16:15:15 -04'00' 0 ISS FOR CONSTRUCTION No. Revision/Issue Date PROPOSED PLANS FOR: REPURPOSE PROPERTIES 135 HIGHBANK STREET SOUTH YARMOUTH, MA SECOND FLOOR PLAN Nov 14 2022 HEALTH DEPT. PROJECT %W A 1.2 DATE OCTOBER 19, 2022 saki AS INDICATED FOUNDATION AND CONCRETE NOTES: 1. SPREAD FOOTINGS SHALL BEAR LEVEL ON UNDISTURBED SOIL HAVING AN ALLOWABLE BEARING CAPACITY OF 2 TONS PER SQUARE FOOT. 2. IF BEARING MATERIALS WITH A LOWER BEARING CAPACITY THAN TWO TONS PER SQUARE FOOT ARE ENCOUNTERED AT THE SPECIFIED ELEVATIONS, THE UNDERLYING UNSUITABLE MATERIAL IS TO BE REMOVED. EXCAVATE DOWN TO SUITABLE SOIL & CAST ACCORDINGLY. 3. NO FOUNDATION SHALL BE PLACED IN WATER OR ON FROZEN GROUND. 4. FOOTINGS SHALL BE PROTECTED AGAINST FROST UNTIL PROJECT IS COMPLETE. 5. BACKFILL AT ANY PORTION OF THE BUILDING SHALL BE COMPACTED IN 6" LIFTS OF 95% COMPACTED GRAVEL AS APPROVED BY AN ENGINEER. 6. BACKFILL NO EXTERIOR WALLS UNLESS PERMANENT STRUCTURAL SUPPORTS (FRAMED FLOORS AND SLABS) ARE IN PLACE, BRACE ALL WALLSAND GRADE BEAMS DURING BACKFILLING. UNLESS OTHERWISE APPROVED BY ENGINEER WITH REBAR QUALIFICATIONS TO MEET OSHA REQ. 7. CONCRETE WORK SHALL CONFORM TO THE LATEST AMERICAN CONCRETE INSTITUTE CODE FOR "BUILDING CODE REQUIREMENTS AND REINFORCED CONCRETE" AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS". 8. CONCRETE SHALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3,500 PSI AT 28 DAYS WITH A SLUMP OF OF NO MORE THAN 4" AND AIR ENTERTAINMENT OF 4-6%. THE USE OF CALCIUM CHLORIDE IS NOT PERMITTED. PROVIDE PROPER CONCRETE PROTECTION IN HOT OR COLD WEATHER AND MAINTAIN PROPER CURING PROCEDURES IN ACCORDANCE WITH THE A.C.I. 9. STEEL REINFORCEMENT SHALL CONFORM TO A.S.T.M. 615, GRADE 60. 10. ALL CONCRETE SLABS PLACED ON GROUND SHALL BE REINFORCED WITH 6X6 - 10/10 (MIN.) WELDED WIRE FABRIC REINFORCEMENT AND SHALL CONFORM TO A.S.T.M. A185, AND SHALL LAP 6" MINIMUM OR ONE SPACE, WHICHEVER IS LARGER, AND SHALL BE WIRED TOGETHER. 11. WHERE CONTINUOUS BARS ARE CALLED FOR THEY SHALL BE RUN CONTINUOUSLY AROUND CORNERS AND LAPPED AT NECESSARY SPLICES OR HOOKED AT DISCONTINUOUS ENDS. LAPS SHALL BE 40 BAR DIAMETERS, UNLESS OTHERWISE SHOWN. 12. INSTALLATION OF REINFORCEMENT SHALL BE COMPLETED AT LEAST 24 HOURS PRIOR TO SCHEDULED CONCRETE PLACEMENT. NOTIFY DESIGNER OF COMPLETION AT LEAST 24 HOURS PRIOR TO SCHEDULED COMPLETION. 13. PLACEMENT OF CONCRETE POURS FOR FOUNDATION WALLS GRADE BEAMS SHOULD NOT EXCEED 60 FEET IN ANY STRAIGHT LENGTH AND SHOULD HAVE VERTICAL 2"X4" KEY AND CONTINUOUS REINFORCING (40 BAR DIAMETER MINIMUM) THROUGH THE CONSTRUCTION JOINT. 14. ALL REINFORCING BARS SHALL BE COLD BENT IN ACCORDANCE TO THE PROPER RADII ESTABLISHED BY THE AMERICAN CONCRETE INSTITUTE. UNDER NO CONDITIONS SHALL HEAT BE APPLIED TO THE BARS TO OBTAIN BENDS. 15. THE USE OF CONTROL JOINTS IN THE SLAB IS RECOMMENDED TO CONTROL CRACKING. SAW CUT TO A DEPTH OF ONE -FIFTH OF THE DEPTH OF THE SLAB. MAXIMUM SQUARE FOOTAGE NOT TO EXCEED 900 SQUARE FEET. 16. DAMPROOF ALL FOUNDATION WALLS BELOW GRADE. 17. GROUT TO BE NON -SHRINK AND NON-METALLIC WITH A MINIMUM COMPRESSIVE STRENGTH OF 5,000 PSI AT 28 DAYS. USE FIVE-STAR GROUT OR EQUAL. 58'-0" 64" 5'4" 23'-10" 5-8" T-8" 13'-2" L NE OF DECK ABOVE DROP TOP OF W LL TO 6" ABOVE ITADJACENT FIN. 8 -3" 5 -9" 5'-9' GRADE I I 12' DIA, CONC. 4'-0" MI . BEL( GRAD , TYPIC I I I I 8" WIDE CONC. WALL w/ 2x4 <EYWAY INTO I I I I I I I I 20" WI E x 10" DEEP I I I I CONC. BULK FOOTING @ EAD WALLS I I I I I I I I O I o w I —J L------------ ----- --- — — — — — — I--- 0 O I O N N I BE DEPRESS -1---------1CONCRETE 12"�---------------------- Ir ------ — —2--— — — — — — — — — — — — — — — 868 — — — — — — — — — — — — — — — — — — — — — — — — — — — - I r-------------------------------� I I UNFINISHED BASEMENT I I I U N EXCAVATE D/ N CONTROL JOINT I I COMPACTED FILL —1 I (SPACE AT INTERVALS NOT MORE I THEN 30 FEET IN EACH DIRECTION) I I � I 6' 2 1/2" 5'-10 1/4" 5_8" 3,_6" 6_ 6-8 1/4° 4'-6" I I 19'-6" I I I I 0" DEEP I I I I I I I I I BEAM (TYPICAL) POCKE � I IBEAM ABOVE I 1-0 I I —I — — I —�9 — — — — — — I TYPICAL SLAB CONSTRUCTION I I I I I I I r I —, _ I I ~ B M OV _ _ I I 4" CONC. SLAB ON 8" I I L— _J L---J L— S—I- I IZ_ I _j — — — — — — COMPACTED GRAVEL I I I I I I I L J �LI — I L— —J I I I I I I ALL COLUMNS TO BE 3-1/2" DIA. I I 8" W DE CONC. WALL I 0° I STEEL COLUMN (CONCRETE I L —.+ __ I w/ 2 4 KEYWAY INTO I I I I FILLED) ON 30"X30" X 10" DEEP I I 20" WIDE x 10" DEEP I I I I CONCRETE FOOTING. (TYP.) - CONT. CONC. FTG. PROVIDE I I = I I I UNLESS OTHERWISE SPECIFIED - #4 REBAR WITHIN 12" OF TOP, I a I I o J AT MID -HEIGHT OF WALL, AND I 4 NEAR BO FTOM OF WALL, TYP. I I I Z � I I = DI I I I I I I I I SD/CO 244 BO REBAR AT TOM OF I I I I FOO1 ING, TYP. I L•---------- -------------------------- -- J I I DEPRESS DEPRESS CONCRETE 12" BELOW SLAB --- ---- - ---- _.— ---- __. _ - CONC TE 12" ------------------------------ --------------------------- '' — — — — — — ---- ------- — BELOW SLAB o I I N L-- — — — — — — — — — — — — — — — — — -- -----------I I I -------------- ---------- J 12" DIA. CONC. SONOTUBE I I 4'-0" MIN. BELOW GRADE, TYPICAL LINE OF DECKABO\ 14'4" 5-9" 14' 0" 3-8" '-2" 16'-8" V-8" 34'4" 24'-0" C A3.1 Foundation Plan SCALE 1/4" = 1'-0" 0 A A3.1 0 N N Keynote Architecture 45 POWHATTAN DRIVE EAST TAUNTON, MA 02718 Tel. (617) 690-7778 keynote—architecture®comcast.net ARCHff=/EMOIMEER STAMP �'(N OF M4Ss90 ADAM R. yG TADDONIO CIVIL -4 No. 54170 9 O Q c°G/STfc��C FSS/ONAL EN Adam R. Taddonio 2022.11.01 16:14:28-04'00' A ISSUE FOUNDATION PLAN 10.31.22 No. Revision/Issue Date PROPOSED PLANS FOR: REPURPOSE PROPERTIES 135 HIGHBANK STREET SOUTH YARMOUTH, MA SHEET nn.E FOUNDATION PLAN NOTES NOV 14 2022 PROJECT SHM S 1 . 1 DATE OCTOBER 19, 2022 scuE AS INDICATED B.O. JOISTS/ T.O. PLATE 2X SHEAR - BLOCKING, TYP. 2ND FLR. PROVIDE MIN. (2) SIMPSON DTT2Z DECK TENSION TIES W/ 1/2" THREADED ROD OR (4) SIMPSON DTT1Z TENSION TIES PER DECK, INSTALLED PER MANUFACTURERS SPECIFICATIONS, TO MEET MINIMUM LATERAL DECK TIE AS REO'D BY CODE C ,'? DECK 60 RAILING BALLUSTRA E SYSTEM AS SELECTED BY OWNER FIRST FLOOR I 1ST FLR. IlNCTC AQrr FPA1jw(., ao BSMT SLAB TYPICAL ROOF CONSTRUCTION (U.O.N.): FIBERGLASS ROOF SHINGLES SIDING OVER 15# FELT OVER 1/2" SHEATING, W/ ICE & WATER SHIELD AT ALL EAVES, HIPS, VALLEYS, SIDEWALLS. I 41- 1 NG COLLAR TIES FRPF ��RS SSE ATTIC FG� JOISTS (SEE FRAMING) , R-49, BLOWN -IN INSULATION, TYP. @ CLG. BEDROOM #3 FLOOR JOISTS (SEE FRAMING) 1/2" GWB ON 1X3 STRAPPING, TYP, @ CLG, U.O.N. EATING - R-21 INSUL. W/ VAPOR BARRIER @ EXTERIOR WALLS, TYP. FLOOR JOISTS (SEE FRAMING) BEAM W/ UNFINISHED BLOCKING A OVE (SEE FRAMING LAN) BASEMENT 3-1/2" DIA.- LALLY COLUMN 4" CONC. SLAB Building Section SCALE 1/4" = 1'-0" 12 �12 TYPICAL EXTERIOR WALL CONSTRUCTION (U.O.N.): VINYL SIDING OVER HOUSEWRAP (W/ TAPED JOINTS) OVER EXTERIOR SHEATHING (7/16" MIN. THICKNESS) OVER 2X6 STUDS @16" O.C. W/ SINGLE BOTTOM PLATE AND DOUBLE TOP PLATE. R-49, BLOWN -IN SULATION, TYP. @ 0PED CLG. (STRAP DN �14JACIHIEVE AS NECESSARY TO MIN R-VALUE) C L 8" FASCIA AND OVERHANG W/ METAL DRIP AND GUTTER, TYP. — FLUSH FRAME BEAM, SEE FRAMING FAMILY ROOM 1/2" DIA. ANCHOR BOLTS @ 48" O.C. AND WITHIN 12" OF ALL CORNERS, W/ 3"X3' WASHER PLATES. 8" MIN. EMBEDMENT INTO CONC. R-30 INSUL. @ FLOORS, TYP.. 8" WIDE CONC. WALL w/ 2x4 KEYWAY INTO 20" WIDE x 10" DEEP CONT. CONC. FTG. PROVIDE #4 REBAR WITHIN 12" OF TOP, AT MID -HEIGHT OF WALL, AND NEAR BOTTOM OF WALL, TYP. 244 REBAR AT BOTTOM OF FOOTING, TYP. fV OP N bo B.O. JOISTS/ T.O. PLATE 2ND FLR. 1ST FLR. BSMT SLAB 12 4 C� NG COLLAR TIES RooF RS SSE ATTIC JOISTS (SEE FRAMING) R-49, BLOWN -IN INSULATION, TYP. @ CLG. BEDROOM #2 FLOOR JOISTS (SEE FRAMIN w J � J m 3 r ca � ZZ � U BATH R-21 INSUL. W/ N VAPOR BARRIER @ EXTERIOR WALLS, TYP. BLOCKING UNDER BEARING WALL ABOVE FLOOR JOISTS (SEE FRAMING) s BEAM W/ UNFINISHED BLOCKING ABOVE SEE FRAMING PLAN) BASEMENT 3-1/2" DIA.— LALLY COLUMN F— 4" CONC. SLAB Building Section 12 IN12 R-49, BLOWN -IN INSULATION, TYP. @ SLOPED CLG. (STRAP DN AS NECESSARY TO ACHIEVE MIN R-VALUE) 1/2" GWB ON 1X3 STRAPPING, TYF. @ CLG, U.O.N. BEDROOM #1 1/2" DIA..ANCHOR BOLTS @ 48" O.C. AND WITHIN 12" OF ALL CORNERS, W/ 3"X3" WASHER PLATES. 8" MIN. EMBEDMENT INTO CONC. R-30 INSUL. @ FLOORS, TYP.. 8" WIDE CONC. WALL w/ 20 KEYWAY INTO 20" WIDE x 10" DEEP CONT. CONC. FTG. PROVIDE #4 REBAR WITHIN 12" OF TOP, AT MID -HEIGHT OF WALL, AND NEAR BOTTOM OF WALL, TYP. 244 REBAR AT BOTTOM OF FOOTING, TYP. B.O. JOISTS/ T.O. PLATE 2ND FLR. 1ST FLR. BSMT SLAB � 4\ NG COLLAR TIES ��RS lSE Ra�F F;PF ATTIC JOISTS (SEE FRAMING) R-49, BLOWN -IN INSULATION, TYP. @ CLG. BATH HALL FLOOR JOISTS (SEE FRAMING) 1/2" GWB ON 1X3 — STRAPPING, TYP. @ CLG, U.O.N. KITCHEN - R-21 INSUL. W/ VAPOR BARRIER @ EXTERIOR WALLS, TYP. FLOOR JOISTS (SEE FRAMING) R-30 INSUL. @ - FLOORS, TYP.. UNFINISHED BASEMENT 4" 03NC. SLAB Building Sectio SCALE 1/4" = 1'-0" R-49, BLOWN -IN INSULATION, TYP. @ SLOPED CLG. (STRAP DN AS NECESSARY TO ACHIEVE MIN R-VALUE) STAI R STAI R 244 REBAR AT BOTTOM OF FOOTING, TYP. HURRICANE TIES, WHERE REO'D Keynote Architecture 45 POWHATTAN DRIVE EAST TAUNTON, MA 02718 Tel. (617) 690-7778 keynote—architecture@comcast.net ARCHITECTMGINEER STAMP OF MgSs90 ADAM R. yG TADDONIO o0 CIVIL NO. 54170 9 O � A�O� PO/STEP ONAL EN Adam R. Taddonio 2022.11.01 16:14:44-04'00' 0 ISS FOR CONSTRUCTION No. Revision/Issue Date PROPOSED PLANS FOR: REPURPOSE PROPERTIES 135 HIGHBANK STREET SOUTH YARMOUTH, MA SHEET TITLE BUILDING SECTIONS NOV 14 2022 HEALTH DEPT. PROJECT SHEET A3. 1 DATE OCTOBER 19, 2022 SC&E AS INDICATED SCALE 1/4" = 1'-0"