SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. '�l� Lot j 3 e1 Zone of Contribution: In Out e" Acreage
c, � u Commercial: Residential:Villaci e�-
Floor Plan: V #Bedrooms: 3
Owner: Installer: C ,(1,.‘, ph e/7
Address: Phone: r
Phone:
Builder: Engineer: ' - Mc, S c:, ,:./
Address: Phone:
Phone:
N/A YES NO
1.Required#of copies received
2.Date of soils exam and percolation test not older than 2 years /
3.4-5 ft of naturally occurring pervious material, above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.: v
6. Benchmark indicated and shown-NGVD if near wetlands C/
7. Septic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: y /
9.Leaching minimum 100 ft from wetlands Var.: v
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: 1.../12. System all other setback requirements Var.: \� �L
1 . ses adjustment for maximum high groundwater Var.: , 'vat ;a es.e
14. eac g set 4- ft above adj. water or bottom of test hole Var.: i/'
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '/<"preferred ..,-----'
_18. System meets breakout requirements PVC liner: Wall: I .e-'
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use /
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
ii
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
• 30.Buoyancy calculations for tank/pump chamber C/
31. Engineer to inspect and certify soils: wall: commercial: .
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater /
34.Title V Application and permit fee,installer signature /
35.Foundation footing min.2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: _ v o:o: