HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M._ _ Lot Zone of Contribution: In Out 'Acreage 7 5-
Commercial: Residential:
Street: C. / --jam
Village: NO- fl UO Floor Plan: ��' /r#bedrooms:
Owner: D <n( .} (?..r_c- . Installer: R
Address: '(" t f`"` '` pCG/ 2
Phone:
Phone:
Builder: Engineer: m f j
Address:
Phone:
Phone:
N/A NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years - -
3. 4-5 ft of naturally occurring pervious material, above water table 1-
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ---
5. Water line 10 ft from septic components Var.:
6. Benchmark indicated and shown-NGVD if near wetlands V'
7. Septic tank minimum 10 ft from foundation, deck Var.: I rl
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: -
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: v
1 12. System meets all other setback requirements Var.: ``
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", IA"preferred i
__18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal ✓/
22. System adequately sized for its intended use �
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade L
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking -�
30. Buoyancy calculations for tank/pump chamber v
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ! z
33.H-20 loading is subject to vehicular traffic,groundwater i
1.7
34.Title V Application and permit fee, installer signature
d;•/..;
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: _ 31.4.--A .
.2 - ?' .)- -)