Loading...
HomeMy WebLinkAboutReview Chceklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. C 17 Lot ! Zone of Contribution: In Out v Acreage (72l S c n Commercial: Residential:_] Street: /q C L�w 08-e C" ire Village: ,Floor Plan: V # Bedrooms: 3 Owner: /Installer: I a 4 X c a v .7z-,.0,-, Address: Phone: Phone: Builder: Enginee C ��r: Address: Phone Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 7 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 4 11.Tank/leaching minimum 10 ft from property line Var.: f 12. System meets all other setback requirements Var.: \� 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil(A,B horizons)or 5' removal ir 16. Proposed contours are suitable 1.<,.. 17. System meets slope requirements-min. 1/8", 'A"preferred 1. __18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee O/ 20. Sewage is under 10,000 gpd for parcel ✓ 21.No garbage disposal V 22. System adequately sized for its intended use V 23.Minimum 6"stone or compacted below tank and dbox L/ 24. Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes tj 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V / 28. Septic tank/pump chamber to be factory waterproofed y _ 29. Vent provided if leaching below 3 feet,under driveway/parking Z 7 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: l 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature Ij 33.H-20 loading is subject to vehicular traffic,groundwater V 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 1 1/ V 36. Deed Restriction required max. #bedrooms: max. flow: gpd i V 37. Check area lots for groundwater/Label groundwater in Assessor's Map i Plan reviewed by:_ _ c o:o; 7 ' a,---0.J- a3