HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. / %. I Lot /2 '2- Zone of Contribution: In Out " Acreage 75 S if t) it Commercial Residential: • Street:Village: Floor Plan: �� #Bedrooms: Owner: Installer: Tom. c...,..4 .. p U -f,.../`71 Address: Phone: Phone: Builder: Engineer: / o c4.W CA 'e.. Address: Phone: Phone: N/A YES . NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years / 3. 4-5 ft of naturally occurring pervious material,above water table / 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: / 5. Water line 10 ft from septic components Var.: I t/ 6. Benchmark indicated and shown-NGVD if near wetlands ----- 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: j L. - - 9. Leaching minimum 100 ft from wetlands Var.: I ✓ 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: r 12. System meets all other setback requirements Var.: / 13. Uses adjustment for maximum high groundwater Var.: / 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: / 15. System not in top or subsoil(A,B horizons)or 5' removal 16. Proposed contours are suitable - l` 17. System meets slope requirements-min. 1/8", %"preferred / 18. System meets breakout requirements PVC liner: Wall: l 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use b/ 23. Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade Cam- 1 25. Inspection port on plastic chambers/leach field ----- 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size i 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber . 31. Engineer to inspect and certify soils: wall: commercial: / 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd �G _ 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed b.. Q^...,, _ 60101