HomeMy WebLinkAboutEngineer PlanSYSTEM PROFILE (NOT TO SCALE) r-ACC-ESS COVERS TO WITHIN 6' OF FIN. GRADE NDN EL. 9.9' i ACCESS COVERS TO GRADE --� MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 WATERfEST D'SOX RISERS (rTP.) "TIfIFOR LEVELNESS 4"mscH40 PVC 20 PIPES LEVEL 1ST 2' 2500 GAL H-10 10' SEPTIC TANK/ 7.23' ' TEE PUMP CHAMBER COMBINATION ' 5' UQ LEVEL (ACME OR EI MARK CORNERS OF F LEACHING FIELD W/ REBAR SET 4" BELOW INSPECTION PORT (SEE DF TAL) GRADE 2% SLOPE FILTER FABRIC 1 9.5 TOP 8,74' FINISHED GRADE- 4" LOAM, & SEED CLEAN FILL 4" PERFORATED PVC 3' 0-C. 3/4"-1-1/2- DOUBLE WASHED STONE LEACHING FIELD SEE DETAIL BELOW l3 8.62' 1 8.4PC 5 1.: LEa__ ' 2 MIN INT. DIM.~� 1.48 r.:-;:........._ 1 8. 6" MIN. SUMP � , / / /. o 0 o a o 0 0 0 0 0 0 0 oava°o°o°a°o°o°o°oi a o v o v o 0 o a o 0 0 0 °000°o°o°ono°o°o,°,a000voo;jo�o,°,o�o�o�o,°,o,°,00aao°__- �o�a_r.. jj 8' CRUSHED STONE OR MECHANICAL L_- COMPACTION. (15.221 [21) {2_5 X SLOPE) a-X SLOPE) (-l-X SLOPE) FACTORY WATERPROOFED LEACHING FOUNDATION- 27' - SEPTIC TANK 5 D' BOX 6' FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- ---- 99-- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SY►60LS MAY APPEAR IN 01 TEST HOLE LOGS ENGINEER: DANIEL E_GONSALVES, SE #13587 WITNESS: MALLORY LANGLER - DATE:. 3/12 21 _._-- PERC. RATE _ < 2 MIN INCH CLASS _- SOILS ELEV. 0" E:P 8_5' A LS 1OYR 3/1 10" B LS 20„ 10YR 5/6 C PERC MS 2.5Y 7/6 ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 7.23' SEPARATE CIRCUIT FROM PUMP ZABFL FILER TEE FLOAT SWITCH ALARM ON OU Tt-FT TEE W/EXTENSION ' �- SETTINGS: PUMP O-- N\ 1500 GAL, MIN. 6 THIS SIDE 5" WORKING RANGE of BAFFLE 5" 6.8' - PUMP OFF 12" ACCESS COVERS TO GRADE 0 5 0' NOTES 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8' PER FOOT. 4, DESIGN LOADING FOR ALL PROPOSED PRECAST - UNITS TO BE AASHO H-11 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 6"DEPTH V!N. BE OW '.NU`. 7 THIS PLAN IS FOR PROPOSED WORK ONLY AND 8.24' NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 1 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTED GROUNDWATER CALLING DIGSAFE (1-888-344-7233) AND (� e EL. 2.74 VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000't WORK. PROVIDE QUICK DISCONNECT FOR PUMP 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 34 PARCEL 126 / BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. NOTE: 600f GAL. RESERVE 11 AS SHOWN ON COMMUNITY PANEL PROVIDED IN PC 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN #25001C0589J DATED 7/16/2014 SAND. / 13. ACCESS FOR ROUTINE MAINTENANCE MUST BE VARIANCES REQUESTED: 2" PRESSURE LINE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW UNDER MAX. FEASIBLE COMPLIANCE 15.405: MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER SLOPE TO DRAIN BACK INSTALLATION, INSTRUCT OWNER ON MAINTENANCE. (20 REDUCTION 2 jON IN SETBACK, SAS TO FOUNDATION WEEP HOLES 14, INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: CHECK VALVE SUITABLE FOR PUMP CONNECTION PRIOR TO ORDERING PUMPS. ELECTRICAL PERMIT REQUIRED. REDUCTION IN GROUNDWATER ADJUSTMENT: USE 0.74' OF THE MARCH 1.74' ADJUSTMENT MYERS SRM 4 15. FEMA FLOOD RESISTANT FOUNDATION DESIGN AND SUBMERSIBLE 4/10 HP PUMP COMPLIANT GRADING REQUIRED. DESIGN BY OTHERS. SYSTEM (OR EQUAL) 16. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO (ON BLOCK) DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. 6" BAFFLE FACTORY WATERPROOFED 2500 GAL. SEPTIC TANKZPUMP CHAMBER CONBINA 110N (NOT TO SCALE) i L I STRE CED ARET _ G 1 e - 100: s G ! S82 11'07 o ,°` l , LOT 259 0 DW 9,395± S.F. PAVED y 15 4 ' DRIVE s .., jj 29 7 �L EXISTING DWELLING O' TOF = 9.9' N / (CRAWLSPACE) 6.8' 101, PAfio ONC i T DECK GROUNDWATER ADJ. DATA: WELL: MIW 29 ZONE: A ADJUSTMENT: 1.74' (MARCH) 120" -1_5' GROUNDWATER ENCOUNTERED AT 78" EL. 2.0 DICE #22-402 BENCHMARK: CONC. PAD TH1 =8.85' NAVD88 - \ r 7 Scale:1" 20' E7 17. ENGINEER TO INSPECT AND CERTIFY SYSTEM. MINIMUM 24 HOURS NOTICE REQUIRED. ZONING SUMMARY SYSTEM DESIGN. ZONING DISTRICT: R-25 RESIDENTIAL DISTRICT GARBAGE DISPOSER IS NOT ALLOWED_ MIN. LOT SIZE 25,000 S.F. DESIGN FLOW: _3 BEDROOMS 0 110 GPD = 330 GPD MIN. LOT FRONTAGE 150' USE A 330 GPD DESIGN FLOW MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' SEPT1C TANK: 330. GPD (2) = 660 MIN. REAR SETBACK 20' USE A 2500 GAL. H-10 DUAL COMPARTMENT MAX. BUILDING COVERAGE 25% SEPTIC TANK/PUMP CHAMBER PROPOSED BUILDING COVERAGE 21.9% LEACHING: 330 GPD (.74) = 446 SF REQUIRED BUOYANCY CALCS: 15' X F = = 4 450 SX .74 = 33 SIF G3 GPD OK H-10 2500 GAL. ST/PC WEIGHS 24,000 LBS USE A 15' X 30' PIPE AND STONE LEACHING FIELD a S' ,. 19 n' Y 9 96' Y 62.4 = 11,000 LEIS UP (OK) Yarmouth Health Department (SLAB FNDN) �PROVIDE 46' OF 40 MIL LINER AT 5' OFF SAS IN AREA SHOWN. TOP AT ELEV. 8.8', BOTTOM AT EL. 4.8't HE �.1 JJ ���y-,.�/� 100.UV �La 5 REMO* OE.,I)N ITABLE SOIL.REQUIRED AROUND PERIMETER 017-LEACHING'FACIUTY; DOWN TO -SUITABLE SOIL LAYER; REPLACE-- WITH CLEAN MED. SAND, TO MEET - SPECI_FIWONS.OF 310 CMR 15.255(3 ` Date DATE MAI APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN � OF co 45 CEDAR STREET SOUTH YARMOUTH, MA PREPARED FOR NORTH EASTERN TRADE SERVICES, INC. DATE: JULY 22, 2021 ns •, REV: SEPTEMBER 16, 2021 (HEALTH COMMENTS) of ',�, oFMyssgo REV: JANUARY 19, 2023 (ADDITION FOOTPRINT) d ��o�, VELA �� off 508-362-4541 o ALA fax 508-362-9880 IVIL downcape.com 46502 down cape engineeriar, inc. SS/ONAL ECG civil engineers land surveyors 939 Main Street ( Rte 6A) DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 22-402 RIQUINHA.DWG