Loading...
HomeMy WebLinkAboutEngineer PlanIm a f Z oZN SNO<zE ORS 50 z SITE 5 SNORE oR NANTUCKET SOUND LOCUS SCALE 1"=500' TP- I 0" HT� 6.96 r J 60" 1.96 a C FINE SAND 2.5Y 5/2 N Z 61 " OBS.=1.87 D 96" 2C -1.04 PEAT -2.29 SOIL PROFILE DATE: FEBRUARY 19, 2020 PERFORMED BY: RICK JUDD WITNESSED BY: MALLORY LANGLER STANDING GW: 61" PERC RATE:<2 MIN./IN. LIMIT OF STC ORIFICE LOCATION N/F (TYP-) ) ANN EVANS TRS JENNIFER WALKER TRS 15 KEARSARGE ROAD MAP 19, PARCEL 61 LIMIT OF OVERDIG INSPECT ON PORT CLEANOUT (TYP. OF 2) 120" 144" 168" 192" B- / D HTM 8.00 FILL & PEAT SEE TP 1 C MED SAND C MED SAND C MED SAND TOP OF FOUNDATION ELEVATION=8.91 I I 10' OF 4" SCH 40 PVC S=2% MIN. 8.58 5.25 ;1 SYSTEM PROFILE NOT TO SCALE INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE PROPOSED 1,500 GALLON REINFORCED CONCRETE 10• SEPTIC TANK 14" (H20) INSTALL OUTLET TEE AND L ZABEL FILTER (A1800) PROPOSED SEPTIC TANK MAX. COVER 3' MIN. COVER 1' 7' OF 4SCH 40 PVC S=1X MIN. 5.00 4.93 INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE PROPOSED 1,000 GALLON REINFORCED CONCRETE I10" PUMP CHAMBER (H20) 0.50 - - 0.18 LEVEL - BASE OF 3" CRUSHED STONE CLEANOUT TO GRADE THREADED 1 1/2- SCH 40 PVC WITH 1/4" END CAP o PERFORATIONS IN THE TOP OF o g THE PIPE (SPACING SHOWN) =I -2.00 2.5' 5' 5' 2.5' 2" SCH 40 PVC �_.. _s _ " 45' BEND MAXIMUM -4.00 MANIFOLD 1/4" ORIFICE WITH ORENCO 2" SCH 40 PVC ORIFICE SHIELD FORCEMAIN FROM -6.00 PUMP CHAMBER 1-1/2" PIPE TO BE RUN LEVEL PRESSURE DISTRIBUTION -8.00 DETAIL NOT TO SCALE PROPOSED 10' X 60' PIPE IN STONE LEACH FIELD (PRESSURE DISTRIBUTION) S �T06'00" E 100.00, N/F Rd RESORTS BEACH RESORT 28 SOUTH SHORE DRIVE MAP 19, PARCEL 20.1 N?,1 W 94 g0, N/; PETER & JEAN MARASHIO 223 PAWKANNAWKUT MAP 19, PARCEL 60 U Z W (651 GALLONS) w O w ALARM ON EL=2.01 oz. NON WOVEN GEOTEXTILE FABRIC MINIMUM ELEV.=8.32 L MIN. COVER 9" (TYP.) ° ° f ° ° ° ° 28' OF 1-1 /2" PERF. SCH 40 PVC S-0.000 SLOPE �° (SEE PRESSURE DISTRIBUTION DETAIL) 3/4"-1 1/20 DOUBLE WASHED STONE 60' LONG BY 10' WIDE LEACHING BED INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE THREADED UNION -2" BALL VALVE -STAINLESS STEEL LIFTING CHAIN OR CABLE " WEEP HOLE 2" CHECK VALVE 2" SCH 40 PVC RISER PIPE 4" PUMP ON EL.=1.68 0 MYERS WHR5 1/2 HP z bi PUMP OR APPROVED EQUAL 6" Z w EL PUMP OFF EL=1.18 0 d 6" D IHAMBER ELEV.=0.68 PUMP CHAMBER DETAIL NOT TO SCALE f4v { 'L M 7 / I G ` q 0/ G f 6.04 O ! � B � -1 1 6.96 m / PROPOSED 1 500 GAL. I f CONCRETE C TANK (H20) / f. m f 5.78 / A PROPOSED 1000 GAL, A CONCRETE'%'UMP CHAMBER m (H20) / / i I CB 5 0 \ Y c� a x 6.40 BEDROOM DINING BEDROOM LIVING ROOM GARAGE BATH KITCHEN BATH FRONT BEDROOM EXISTIPNG FLOOR NOT TO . THREADED END CAP TO GRADE LAYER SOLID PIPE 8 OZ. NON Wa DETAIL NOT TO SCALE v v v v o p v v v p v 5' SEPARATION OBSERVED HIGH GROUNDWATER SITE INFORMATION ADDRESS: 227 PAWKANNAWKUT DRIVE, SOUTH YARMOUTH MAP, LOT: 19/59 DEED REFERENCE: 10464/0213 GENERAL NOTES: 1. THE SUBJECT PROPERTY IS WITHIN A FEMA ZONE AE11 AS SHOWN ON PANEL NO. 25001CO589J, EFFECTIVE DATE JULY 16, 2014. 2. THE SITE NOT IS LOCATED WITHIN A ZONE II AREA. 3. THERE ARE NO STREAMS OR WETLANDS WITHIN 100-FEET OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM. 4. VERTICAL DATUM IS ASSUMED LEGEND PROPERTY LINE - EXISTING CONTOUR - -104 PROPOSED CONTOUR XXXX EXISTING FENCE EXISTING OVERHEAD UTILITIES W EXISTING WATER LINE G EXISTING NATURAL GAS LINE TP-1 LOCATION OF TEST PIT/PERC TEST 99.76 X EXISTING SPOT ELEVATION -QFH EXISTING FIRE HYDRANT P -O EXISTING UTILITY POLE E ® WG EXISTING WATER GATE BOX SH BULKHEAD CH CHIMNEY AGM EXISTING GAS METER 0 IP PROPOSED INSPECTION PORT 8 oz. NON WOVEN GEOTEXTILE FABRIC 5. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE C°fast�� P 4N� REGULATIONS AND LOCAL BOARD OF HEALTH AND BUILDING DEPARTMENT REGULATIONS. SURV <�O SHORING REQUIRED TO COMPLETE THIS PROJECT SHALL BE THE RESPONSIBILITY OF THE 1-1/2" PERFORATED SCH 40 PVC PIPE CONTRACTOR. 6. ALL JOINTS IN THE TANK/PUMP CHAMBER AND DISTRIBUTION BOX SHALL BE MADE 1 1 1 { 4 9• MIN. EARTH THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR �}{�BA KFIL '�// BACKFILL HWATERTIGHT YDRAULIC CEMENT. r \ � \) t � 7. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO ANY EXCAVATION av %11 �o o "T 8" DEPTH OF 3/4" TO OCCURRING. o ®, o o s, o s, ° e "�; 1-1/2" DOUBLE WASHI B. LOCATION OF UTILITIES ON THIS PLAN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE ' ° ' ` ' ° ' !° " ' ' CRUSHED STONE FIELD. THE ELEVATIONS OF ALL EXISTING SEWER INVERTS SHALL BE VERIFIED PRIOR TO THE INSTALL OF ANY SYSTEM COMPONENTS. ANY DISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER IMMEDIATELY 3'-0" 4'-0" 3'-0" 9. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR TO BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF INSPECTIONS 101_011 10. UNSUITABLEENCOUNTEREDBELOW A THE INVERT APPLICABLE, SOIL (TION LEACH FIELD CROSS SECTION ABS RPIAL INNLET SYSTEM, SHHA)LL BE DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION NOT TO SCALE WITH CLEAN SAND PER MASSACHUSEfTS 310 CMR 15.00 REGULATIONS. 11. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 12. EXISTING CONDITIONS SURVEY PERFORMED BY PAUL E. SWEETSER, PLS, APRIL 2022 DESIGN CALCULATIONS REQUESTED HEALTH DEPT DESIGN FLOW VARIANCES: 110 GALLONS/DAY/BEDROOM X 4 BEDROOMS - "0 GALLONS/DAY TANK CAPACITY 440 GPD X 200% = 880 GALLONS, USE 1,500 GALLON TANK 310 CMR 15.211(1) OF THE STATE ENVIRONMENTAL CODF REQUIRED LEACHING CAPACITY ••• MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM SAS TO A DESIGN PERC RATE = < 2 MIN/INCH FOUNDATION BE 20 FEET. SAS IS LOCATED t12.7 FEET FROM THE CRAWLSPACE. 440 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 594.95 SQ. FT. VARIANCE OF f7.3 FEET IS REQUESTED. PROVIDED LEACHING CAPACITY ••• MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM RESERVE ARI BOTTOM AREA = 10.0' X 60.0' = 600 SQ. FT. (444 GPD) TO PROPERTY LINE SHALL BE 10 FEET. RESERVE AREA IS LOCATED f5.0 FEE FROM THE PROPERTY LINE. A VARIANCE OF t5.0 FEET IS REQUESTED. PUMP NOTES ••• MINIMUM SETBACK DISTANCE - MINIMUM SETBACK DISTANCE FROM RESERVE ARI TO A FULL FOUNDATION SHALL BE 20 FEET. RESERVE AREA IS LOCATED t5.0 1. USE MYERS MODEL WHR5 1/2 HP PUMP OR APPROVED EQUAL FEET FROM THE FOUNDATION. A VARIANCE OF t15.0 FEET IS REQUESTED. 2. BOTH VISUAL AND AUDIO (AUDIBLE AND LIGHT) ALARMS ARE TO BE LOCATED WITHIN THE DWELLING AND BE POWERED BY A SEPARATE CIRCUIT FROM THE PUMPS 3. ELECTRIC JUNCTION BOX SHALL BE EXPLOSION PROOF NEMA 4X AND SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER IN A SEPARATE STRUCTURE. ALL ELECTRICAL CONNECTIONS SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER 4. PUMP SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND TITLE 5 REGULATIONS. 5. THE PUMP SHALL BE ABLE TO BE REMOVED FROM THE PUMP CHAMBER WITHOUT 4 CRESTVIEW DRIVE ENTERING THE STRUCTURE EAST SANDWICH, MA 02537 6. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS IN THE FORCEMAIN PHONE: (508) 400-2365 7. AN ELECTRICAL PERMIT IS REQUIRED FOR THE INSTALLATION OF THIS SYSTEM SITE DESIGN, L L C PUMP CHAMBER VOLUMES Residential Site Design and Permitting 1. PUMP CHAMBER VOLUME - 244 GALLONS PER FOOT OF HEIGHT 2. VOLUME DOSED PER PUMPING CYCLE = 110 GALLONS OR 0.45' (6') (INCLUDIN Permit for .FLAO471QN.•gh;PTIC SYSTEM 3. EMERGENCY STORAGE = 440 GALLONS OR 1.80' (22") to St a FEB 0 9 2023 HEALTH DEPT. _1 OF -7-