HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. /7 Lot 6- 7 Zone of Contribution: In_ Out h'Acreage f 2 7 '
lea Commercial: Residential:___
Street: as 7 Pea� ju NGL..ok�.y'p�
Village: Floor Plan: #Bedrooms: /
Owner: _ Installer: 3Q r r o 5
Address: Phone:
Phone:
Builder: Engineer: 4V1 s't.-e- aDe C ;
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years .--'
3. 4-5 ft of naturally occurring pervious material,above water table / -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ,...--
5. Water line 10 ft from septic components Var.: .------
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimu A I • f om foundation, deck Var.: 1
8.Leaching minimu, 0 ►/ , 15 ft crawl, 10 ft slab Var.: 17 J, �'
9. Leaching minimum .i ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: 54 L�
12. System meets all other setback requirements Var.: �
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: /
15. System not in top or subsoil(A,B horizons)or 5' removal
16. Proposed contours are suitable /--
17. System meets slope requirements-min. 1/8", %"preferred _
__18. System meets breakout requirements PVC liner: Wall: /
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal
22. System adequately sized for its intended use -
23.Minimum 6"stone or compacted below tank and dbox v
24. Manhole covers within 6"of grade,pump chamber cover to grade C�
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes v-
27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size
28. Septic tank/pump chamber to be factory waterproofed ../
29. Vent provided if leaching below 3 feet,under driveway/parking �...---
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: /
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater ✓---
34.Title V Application and permit fee, installer signature
35.Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ti
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by. 2 o#' 23 60:0: