Loading...
HomeMy WebLinkAboutEngineer PlanGENERAL NOTES: 1. CONTRACTOR SHALL NOTIFY 'DIG -SAFE" AS REQUIRED PRIOR TO THE START OF ANY EXCAVATION WORK. CONTRACTOR IS RESPONSIBLE FOR PROTECTING UTILITIES WITHIN THE WORK AREA DURING CONSTRUCTION. 2. THIS PLAN IS FOR SEWAGE DISPOSAL SYSTEM DESIGN PURPOSES ONLY. THIS PLAN IS NOT FOR USE TO DETERMINE PROPERTY LINES. PROPERTY UNES PER CERTIFIED PLOT PLAN BY R.J. O'HEARN DATED 11/28/82 ON FILE AT THE YARMOUTH TOWN HALL 3. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION 4. ALL CONSTRUCTION SHALL CONFORM TO THE STATE SANITARY REGULATIONS (310 CMR 15.00) AND ALL OTHER APPUCABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. 5. CONTRACTOR TO VERIFY EXISTING CONDITIONS, INCLUDING ELEVATIONS OF EXISTING BUILDING SEWER, AND REPORT AND DISCREPANCIES TO THE DESIGN ENGINEER PRIOR TO THE SETIING OF ANY SEWAGE DISPOSAL SYSTEM COMPONENTS. SEWAGE DISPOSAL SYSTEM NOTES: 1. H-20 RATED COMPONENTS SHALL BE REQUIRED IN ANY AREAS SUBJECT TO VEHICULAR LOADING AND AS REQUIRED ON THE PLAN. 2. THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS CONSTRUCTED AS SHOWN. ANY CHANGES OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING. 3. ALL GRAVITY SEWER PIPE SHALL BE 4" CIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4' DIA. SCH 40 PVC SHALL BE 0.01 FT/FT. 4. SOIL ABSORPTION SYSTEMS MUST BE VENTED WHEN DISTRIBUTION LINES EXCEED 50 FEET IN LENGTH, WHEN LOCATED IN AREAS SUBJECT TO VEHICULAR LOADING, AND WHEN PRESSURE DOSED. 5. FINISHED GRADE SHALL BE A MAXIMUM OF 36" AND A MINIMUM OF 9' OVER THE TOP OF ALL SYSTEM COMPONENTS 6. EXISTING LEACH PIT TO BE PUMPED DRY, FILLED WITH CLEAN SAND AND ABANDONED IN PLACE. 7. ALL SEPTIC COMPONENTS SHALL BE INSTALLED WATERTIGHT. 8. COMPONENTS TO BE PROVIDE WITH WATERTIGHT ACCESS COVERS RAISED TO WITHIN 6" OF GRADE WHERE REQUIRED. 9. PRIOR TO FINAL INSPECTION BY THE ENGINEER AND THE BOARD OF HEALTH ALL SYSTEM COMPONENTS MUST BE INSTALLED INCLUDING ALL ACCESS COVERS WITH RISERS. 10. CONTRACTOR TO VERIFY ELEVATIONS OF EXISTING SEPTIC TANK OUTLET AND REPORT AND DISCREPANCIES TO THE DESIGN ENGINEER PRIOR TO THE SETTING OF ANY SEWAGE DISPOSAL SYSTEM COMPONENTS. SCHEMATIC FLOW PROFILE: NOT TO SCALE RAISE COVERS TO WITHIN 6" OF FINISH GRADE :2" min. 3" max. TEES AN . _ PVC EXISTING 1,000 GALLON SEPTIC TANK (H-10) DEEP OBSERVATION HOLE LOGS NO SCALE DEEP OBSERVATION HOLE 1 EL = 56.3t DEPTH FROM SURFACE SOIL HORIZON SOIL TEXTURE SOIL COLOR MUNSELL 0' - 10' A LOAMY SAND 10 YR 3/4 10" _ 34" B LOAMY SAND 10 YR 5/8 34" - 144' C1 M/C SAND 10 YR 8/6 DATE OF TESTING: 9/22/21 PERCOLATION RATE: LESS THAN 2 MIN/INCH IN C2 LAYER (PERC 0 72") WITNESSED BY: KEITH E. FERNANDES, PE, DIG -IT CONSTRUCTION LLC PHILIP RENAUD, HEALTH AGENT, YARMOUTH HEALTH DEPARTMENT NO GROUNDWATER ENCOUNTERED USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM. SAS DETAIL SCALE: 1" = 10' PROPOSED INSPECTION PROPO'. BUILD - COVER 23' 3' 8.5' 8.5' 3- �r 2 SYSTEM DESIGN CALCULATIONS; EXISTING 2 BEDROOM DWELLING AT 110 GAL. PER DAY PER BEDROOM = 220 GPD DESIGN FOR 2 BEDROOMS (YARMOUTH BOARD OF HEALTH REQUIREMENTS) = 220 GPD 220 GPD X 200% = 440 GALLONS - RE -USE EXISTING 1000 GALLON TANK 23' L. X 10.83' W. X 2' D. LEACHING CHAMBER (H-20) CAN LEACH: Vt = ((23 X 10,83) + (23 X 2)2 + (10.83 X 2)21 X 0.74 GPD/SF = 284 GPD NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN. INSTALL TWO (2) - 500 GALLON LEACH CHAMBERS (H-20) WITH 3' OF STONE AROUND ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20) LL PLAN VIEW SCALE. 1" = 20' 110.00' Existing Leach pit ' M co (See Note #6) d i z I " � 17 it 1 ST I N - 1 � ' W U " J Existing 2 Bedroom Top of i m 'o a Dwelling Foundation EL=56.St a i _ m `• LOT #34 AREA = 12,975 SQ. FT. p ry ^>c5 v 1� 85.00' Edge oI pavement CARDINAL LAN L taov 1 7 2021 I HEALTH DEPT. BASIN RIM RAISE COVER TO WITHIN 6" RAISE (1) COVER TO WITHIN 6' OF EL=53A± (NAVD88) OF FINISH FINISH GRADE GRADE FINISH GRADE=56.0t FINISH GRADE=56 (MAX) UNE(S) EXITING D'BOX SHALL HAVE 35" Proposed 4"4 SCH 40 SPEED LEVELERS AND SHALL REMAIN (9" Min - 36" Max) PVC PIPE LEVEL FOR BEFORE PITCHING LEA DOWN TO LEACHING FACILITY n� �4" CIA SCH 40 PVC PIPE -S 53.1: •52.71 *EXISTING 52 42 (SEE NOTE 110) 17't 1 52.25 1 r KEITH E. 1 FERNANDES CIVIL No. 48725 KITCHEN BED m LIVING BED FLOOR PLAN NOT TO SCALE Yarmouth Health Departmem APPROVED Sri 1tv"S '1111-11alew Name Date REVISED 11-16-2021: LEACHING CAPACITY REVISED DIG -IT CONSTRUCTION, LLC PO BOX 268 SOUTH DENNIS, MA 02660 PHONE: 508-432-1635 www.digitconstructionllc.com CUENT: MJ NARDONE BUILDING &REMODELING 299 WHITES PATH S. YARMOUTH, MA 02664 2" LAYER OF 1/8" - 1/2" STONE (OR FILTER FABRIC) 3/4" - 1-1/2" STONE DOUBLE WASHED STONE (1) 4' SCH. 40 PVC INSPECTION PORT W/ 18" PIECE OF #4 REBAR RAISE TO WITHIN �-- 4' OF GRADE PIPE SHALL BE PERFORATED WITHIN FIELD 52.10 ' DEPTH ALL COMPACTED BASE DB-3 W/ 6' LAYER OF 50.1± USE (2) SHOREY PRECAST (OR EQUAL (H-20) CRUSHED STONE ALL 500 GALLON LEACH CHAMBERS (H-20) 5.8 BOX NTH STONE AROUND (SEE SAS DETAIL) 15'3 LONGEST RUN (END VIEW) �- LEACHING CHAMBER 23' x 10.83' x 2.0' 0 20 40 60 SCALE 1"=20' EL=44.3t BOTTOM OF TEST PIT #1 C:\Users\kfern\Dig It Construction Dropbox\AAEngineering\Active Jobs\7001 - 28 Cardinal Lane - Yormouth\CAD\Plan s\7001-SAS(REVISEDI1-16-2021).dwg