Loading...
HomeMy WebLinkAboutCCIP Hotel Lobby Reno Permit Drawings 2-28-2023-stamp-flat'1 UP UP UP '1 UP UP UP 32'-11 1/4" 21'-9 1/8" 3'-1 5/8"16'-6 1/2" 2'-1"15'-2 1/4"30'-10 1/4"4'-7 1/8"4'-6 3/4"4'-11 1/4"8'-4 3/8"19'-6 1/4"6'-4 1/4"1'-4 3/8"17'-7 3/4"14'-6 5/8"16'-4 3/8"13'-7 5/8" 29'-10"6'-2 1/2"4'-11" 1'-7 1/2" 9'-9 5/8"10'-9 1/4"2'-10 1/4"7'-11"(13'-11") 13'-9 1/8"8" 2'-6" 3'-2 1/2" 1'-11 3/8" 3'-1" 1'-11 3/4"1'-10 3/4"6'-0" 5'-0" 11'-0 1/2" 3'-6" 6'-7 1/4" 3'-0" 10" 2'-9"3'-0 1/4" 3'-6 5/8" 2'-11" (-1'-10 1/4" A.F.F.) 4" 2'-3" 2'-3 3/8" R.O. 5'-4 1/2" 3'-6 1/4" (-7" A.F.F.) 7'-2 7/8"8'-1 7/8"10'-9 1/4"1'-10 1/4" 1'-0" 6'-11" 2'-8" 4'-10" 9 1/4" 3'-8 1/2" 2'-8" 6" 7 1/4" 4'-3 3/4" 3'-0" 2'-3 1/4" (-9 1/2") MOP SINK 2' x 2' (ETR) 3'-0 3/4" 5'-3 1/2"(14'-11 5/8")15'-1 1/8"15'-0 5/8"  PRIVATE HALLWAY 8'-7" 2'-1" ABOVE CANOPY TO BE DEMO FIRE ALARM SYSTEM VENTIALTION FIRE PULL NEXT TO ENTRY DOOR EXISTING STEEL BEAM TO REMAIN SUBFLOOR TO B.O. BEAM = 6'-9 9/16" VERIFY IN FIELD EXISTING KITCHENETTE / CABINETRY TO BE REMOVED EXISTING CABINETRY TO BE REMOVE EXISTING BACK OFFICES EXISTING RECEPTION / OFFICE EXISTING CLOSET / IT 7'-0 1/4"EXISTING DINING ROOM EXISTING FIREPLACE TO BE BOARDED UP EXISTING ADA RAMP TO REMAIN EXISTING STEEL BEAM ABOVE TO REMAIN SUBFLOOR TO B.O. BEAM = 6'-8 1/8" V.I.F. (-0" A.F.F.) EXISTING COLUMNS 4'-2 5/8"6'-4 1/4"EXISTING COLUMN-SEE DEMO PLAN EXISTING COLUMN TO REMAIN  1. WORK AREA - 1,890 SF 2.COORDINATE ALL DEMOLITION WITH PHASING PLAN AS PREPARED BY GC. 3. VERIFY ALL DIMENSIONS IN THE FIELD AND COORDINATE WITH ARCH DWGS. PRIOR TO DEMOLITION. 4. THE EXISTING DEALERSHIP SHALL REMAIN OPERATIONAL UNTIL THE RENOVATION IS COMPLETED. GC TO COORDINATE SCHEDULING AS REQ'D. 5. ANY DISCREPANCIES BETWEEN THE DEMOLITION FLOOR PLAN AND PROPOSED ARCH DWGS SHALL BE REPORTED TO THE GC AND THE ARCHITECT IN WRITING. 6. DEMOLITION OF ALL ELECTRICAL, MECHANICAL, HVAC, PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE COORDINATED BY THE GC AND ARE NOT INDICATED ON THESE DRAWINGS. 1 EXISTING NON-LOAD BEARING WALLS TO BE DEMOLISHED (V.I.F.) REMOVE LOAD BEARING EXTERIOR WALL AS SHOWN AFF. PROVIDE TEMP SHORING AS REQUIRED. SEE PROPOSED ARCH & STRUCTRUAL PLANS FOR MORE INFO. DEMOLISH EXISTING DOOR & FRAME. REMOVE GLAZING AND FRAME EXISTING COLUMN TO REMAIN - TO BE DETERMINED AT DEMO EXISTING GLAZING TO REMAIN DEMO EXISTING RAILING EXISTING PLUMBING FIXTURES TO REMAIN REMOVE EXISTING COUNTER TOPS /CABINETRY DEMO BEAM - VERIFY IN FIELD & COORD. WITH ARCHITECT REMOVE EXISTING FLOORING AND REPLACE REMOVE EXISTING FIXTURES AND REPLACE EXISTING COLUMN TO BE REMOVED AND RELOCATED EXISTING COLUMN TO BE REMOVED 2 3 4 5 6 7 8    PRIVATE HALLWAY 1 9 2 3 3 1 1 3 2 9 9 9 12 8 DEMO EXISTING FIREPLACE (-7" A.F.F.) (-7" A.F.F.) (0" A.F.F.)10 10 1 4 11 11 11 11 11 11 5 12 3 4 A-2.0 13 13 RELOCATED COLUMN LOCATION7"14 14 SHEET NO.JOB NO.PROJECT:SCALE:DRAWN BY:DATE:SUBJECT:833 TURNPIKE ROAD P.O. BOX 104 NEW IPSWICH NEW HAMPSHIRE 03071 ARCHITECTURE LAND PLANNING INTERIOR DESIGN 3D VISUALIZATION THIS DESIGN AND THE DRAWINGS THEREFORE, PREPARED FOR THIS PROJECT, ARE THE PROPERTY OF THE ARCHITECT, BRUCE RONAYNE HAMILTON, ARCHITECTS INC., AND, THE DESIGN AND/OR DRAWINGS MAY NOT BE USED IN WHOLE OR IN PART FOR ANY USE OTHER THAN FOR THE ORIGINAL PROJECT FOR WHICH THE DESIGN AND/OR DRAWINGS WERE PREPARED, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS, INC. NO BUILDING PERMIT SHALL BE ISSUED BY ANY BUILDING DEPARTMENT, UNLESS THIS DOCUMENT BEARS THE ORIGINAL SEAL AND SIGNATURE OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS INC.1/4" = 1'-0"223211/04/2022BB   H    LAUA 1/4" = 1'-0"A-0.0 1        1/4" = 1'-0"A-0.0 2     REV. NODESCRIPTION OF REV.REV. DATE1UNISEX ACCESSIBLE BATHROOM REVISIONS -RAMP REVISIONS2/15/20232UNISEX ACCESSIBLE BATHROOM REVISION-RAMP REVISIONS -2 ; VERIFIED BEAMS2/28/2023THIS DESIGN AND THE DRAWINGS THEREFORE, PREPARED FOR THIS '1 UP UP 1'-10 1/8" NEW DOOR OPENING V.I.F. 10'-0" 1'-9 1/2" 2'-9"3'-4 1/2"FIRE ALARM SYSTEM ETR VENTIALTION ETR FIRE PULL NEXT TO ENTRY DOOR PRIVATE HALLWAY UNISEX ETR REVISED DOOR OPENING NEW RAMP 1:12 (-7" A.F.F.) RECEPTION BACK OFFICE STATIONS (3) RECEPTION STATIONS EXISTING COLUMNS TO REMAIN (V.I.F.) PROVIDE NEW ARCH. COLUMN COVER A-2.0 6A-2.0 7 EXISTING STAIR TO REMAIN STEP DOWN -7" A.F.F. DN NEW VINYL FLOORING I.T. CLOSET (ETR)3'-5"SEATING AREA 2'-6"8'-0"EXISTING STEEL BEAM TO REMAIN A.F.F. TO B.O. BEAM = 6'-8 1/8" NEW ACCENT TILE BACK CABINETS BREAKFAST STATION 7'-7 3/4" NEW TILE $  10'-7 3/4" ENCLOSE STAIR TO BASEMENT EXISTING DOOR TO REMAIN 3'-0" NEW UNISEX ACCESSIBLE RESTROOM 3 A-1.0 4 A-1.0 $  9'-5 3/4"5'-8 7/8" 1'-0" A-1.0 611'-7 3/4"6 3/4"19'-9" 2 101 102 103 5 A-2.0 $  4'-11 1/8"CLEARR 2' - 6"NEW COLUMN -SEE DEMO PLAN 7 3'-10 1/4" 3'-4" 2'-8 1/4"MIN6'-0"4 1/8"7'-7 3/4" 1'-10"1'-0"1'-0"3'-6 3/4"104 CLEAR4'-0"RAMP4'-6"4 3/4"1'-0"OPENING5'-6"4'-1 7/8"1'-0" DN 1 4 A-2.0 2 3 1 1 EXISTING COLUMN TO REMAIN 1'-4" A-2.0 6A-2.0 7 CABINETS 12'-0" 4'-2" 1'-10 1/2" 4'-3" 1'-10 1/2" 4'-3" 3'-4" 101 DOOR OPENING (ETR)2'-6"2'-1"2'-1"10'-6"11'-7 3/4" 6 3/4" 7'-7 3/4"2'-0"2'-0"15'-2 1/8"RECEPTION BREAKFAST STATION 1'-1"HALF WALL9'-5"8'-8 5/8"7'-9"2'-0"6'-0"V.I.F.4'-7 1/4"3 A-1.0 4 A-1.0 2 4 A-2.0 1'-9 3/4" 4" 2 7/8"2'-10"9"2'-1"1'-6"COUNTER TOP FINISH BY OWNER 2'-4 5/8" 2'-6" 1'-3" 2'-1" 2'-0" 1'-9 3/4"1 1/2"2'-4 1/2"2 1/4"1'-6"1'-0"9"2'-6"9'-10 1/2"4 1/8"MIN. CLEAR6'-0"4 3/4"GRAB BARS3'-6"1'-0"4 1/8"6" GRAB BARS 3'-6" 2'-11 5/8"4'-6 3/4"3'-10 1/4" 3'-4" 2'-8 1/4" 1 1 EXISTING UNISEX TO REMAIN A-1.0 69'-5 3/4" 103 7 7'-7 3/4" 104 1'-10"4 3/4" 1 2 3 NEW CLOSET V.I.F. 6'-11 5/8"1'-0"1'-0" R 2' - 6" 1'-6"5'-4 1/8"2'-8"FIRST FLOOR 0" CEILING 7' -4 9/16"CTOP-MAX2'-10"MIN2'-5"APRON SINK MAX-MIRROR3'-4"36" MIRROR BY OWNER 72" MIN6'-4"MIN9"*:%67$1'$5'3$57,7,21 ;:22'678'6*:%67$1'$5'3$57,7,21 [:22'678'6 5/8" GWB BOTH SIDES, PAINTED; M.R. GWB AT RESTROOMS AND BEHIND SINKS 2 3/4" FIBERGLASS INSULATION 2X4" WOOD STUDS @ 16" O.C. 5/8" GWB BOTH SIDES; PAINTED REST ROOMS: 5/8" M.R. GWB ON REST ROOM, PAINTED; INSTALL DURAROCK (OR EQUAL) AT WET WALL BEHIND TILE 5 1/2" FIBERGLASS INSULATION AT PLUMB WALL 2X6 WOOD STUDS @ 16" O.C. PLAN PLAN REST ROOMS: 5/8" M.R. GWB ON REST ROOM SIDE PAINTED; INSTALL DURAROCK (OR EQUAL) AT WET WALL BEHIND TILE 6 3/4"4 3/4" *:%67$1'$5'3$57,7,21 ;:22'678'6 2 3/4" FIBERGLASS INSULATION AT PLUMB WALL 2X4 WOOD STUDS @ 16" O.C. PLAN REST ROOMS: 5/8" M.R. GWB ON REST ROOM SIDE PAINTED; INSTALL DURAROCK (OR EQUAL) AT WET WALL BEHIND TILE 4 1/8" FIRST FLOOR 0" CEILING 7' -4 9/16" B.O. JOISTS 7' -7 3/4"3'-0"17"-19"GRAB BARS 3'-6"6" FINISHED GYP CEILING OPTIONAL WALL FINISH: TILE -BY OWNER 5"MIN2'-5"1'-10"7'-7 3/4"MAX2'-10"6"8"9"CTOP -FINISH SOLID SURFACE P-LAM SINK APRON SHEET NO.JOB NO.PROJECT:SCALE:DRAWN BY:DATE:SUBJECT:833 TURNPIKE ROAD P.O. BOX 104 NEW IPSWICH NEW HAMPSHIRE 03071 ARCHITECTURE LAND PLANNING INTERIOR DESIGN 3D VISUALIZATION THIS DESIGN AND THE DRAWINGS THEREFORE, PREPARED FOR THIS PROJECT, ARE THE PROPERTY OF THE ARCHITECT, BRUCE RONAYNE HAMILTON, ARCHITECTS INC., AND, THE DESIGN AND/OR DRAWINGS MAY NOT BE USED IN WHOLE OR IN PART FOR ANY USE OTHER THAN FOR THE ORIGINAL PROJECT FOR WHICH THE DESIGN AND/OR DRAWINGS WERE PREPARED, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS, INC. NO BUILDING PERMIT SHALL BE ISSUED BY ANY BUILDING DEPARTMENT, UNLESS THIS DOCUMENT BEARS THE ORIGINAL SEAL AND SIGNATURE OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS INC.Asindicated223211/04/2022BB     L8UA 1/4" = 1'-0"A-1.0 1   1/4" = 1'-0"A-1.0 2    1/2" = 1'-0"A-1.0 3    8 1/2" = 1'-0"A-1.0 4    9 3/8" = 1'-0"A-1.0 5    3/8" = 1'-0"A-1.0 6 8  U LOCATION DOOR FRAME CLOSER COMMENTSMARKOPERATION OPENING PANEL MATLWIDTHHEIGHTTYPEMATLCONFIG 101 SINGLE - HINGED 2' - 8" 3' - 0" F WOOD SINGLE WOOD PAINTED - COLOR TBD 102 SINGLE - HINGED 3' - 0" 6' - 8" F WOOD SINGLE WOOD No PAINTED - COLOR TBD 103 SINGLE - HINGED 3' - 0" 6' - 8" F WOOD SINGLE WOOD Yes PAINTED - COLOR TBD 104 SINGLE - HINGED 2' - 0" 6' - 8" F WOOD SINGLE WOOD PAINTED - COLOR TBD REV. NODESCRIPTION OF REV.REV. DATE1UNISEX ACCESSIBLE BATHROOM REVISIONS -RAMP REVISIONS2/15/20232UNISEX ACCESSIBLE BATHROOM REVISION-RAMP REVISIONS -2 ; VERIFIED BEAMS2/28/20233/8" = 1'-0"A-1.0 7 9 THIS DESIGN AND THE DRAWINGS THEREFORE,PREPAREDFOR THIS '1 UP UP NEW GYP 7'-4 5/8" A.F.F. EXISING BEAM IN GYP SOFFIT NEW GYP 7'-4 5/8" A.F.F. NEW ACT - SLOPED CEILING A.F.F. -VERIFY IN FIELD 4 A-2.0 CEILNG EXISTING TO REMAIN    \ 1. LIGHTING LAYOUT SHOWN AS A GRAPHIC REPRESENTATION ONLY; REFER TO ELECTRICAL SUB DWGS FOR EXACT LOCATION AND QUANTITIES. 2. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EGRESS & EMERGENCY LIGHTING FIXTUES TO COMPLY W/ LOCAL & STATE BUILDING CODES. 3. ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGN BUILDER OF ANY DISCREPANCIES BETWEEN THE ELCTRICAL LIGHTING PLANS & THE ARCHTIECTURAL REFLECTED CEILING PLANS. 4. ARCHTIECT & GENERAL CONTRACTOR SHALL REVIEW MECHANICAL AND ELECTRICAL PLANS TO COORDINATE LIGHT FIXTURE LOCATIONS W/ SUPPLY & RETURN DIFFUSERS.    \ NOTE: NEW RECESSED LIGHTING TO MATCH TO EXISTING GYP CEILING -PAINTED WHITE RECESSED LED CAN LIGHTING FIXTURE 2X2 GRID LED RECESS LIGHTS 2X2' GRID ACOUSTICAL CEILING SYSTEM PRIVATE HALLWAY UNISEX RESTROOM ETR (-7" A.F.F.) RECEPTION BACK OFFICE STATIONS I.T. CLOSET (ETR) SEATING AREA BREAKFAST STATION NEW UNISEX ACCESIBLE RESTROOM EXISTING COLUMNS TO REMAIN PROVIDE NEW ARCHITECTURAL COLUMN COVER R 8"    \ 1. FLOOR FINISHES SHOWN AS A GRAPHIC REPRESENTATION ONLY. OWNER TO APPROVE ALL FINISHES. 2. REMOVE ALL EXISTING FLOORING AND UNDERLAYMENT AND REPLACE WITH NEW. COORDINATE WITH OWNER AND GENERAL CONTRACTOR.     \ NOTE: ALL FINISHES TO BE APPROVED BY OWNER. LVT -LAMINATED VINYL TILE CT-1 CERAMIC TILE CT-2 CERMAIC TILE ACCENT LVT-2 LAMINATED VINYL TILE R -RUBBER SHEET NO.JOB NO.PROJECT:SCALE:DRAWN BY:DATE:SUBJECT:833 TURNPIKE ROAD P.O. BOX 104 NEW IPSWICH NEW HAMPSHIRE 03071 ARCHITECTURE LAND PLANNING INTERIOR DESIGN 3D VISUALIZATION THIS DESIGN AND THE DRAWINGS THEREFORE, PREPARED FOR THIS PROJECT, ARE THE PROPERTY OF THE ARCHITECT, BRUCE RONAYNE HAMILTON, ARCHITECTS INC., AND, THE DESIGN AND/OR DRAWINGS MAY NOT BE USED IN WHOLE OR IN PART FOR ANY USE OTHER THAN FOR THE ORIGINAL PROJECT FOR WHICH THE DESIGN AND/OR DRAWINGS WERE PREPARED, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS, INC. NO BUILDING PERMIT SHALL BE ISSUED BY ANY BUILDING DEPARTMENT, UNLESS THIS DOCUMENT BEARS THE ORIGINAL SEAL AND SIGNATURE OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS INC.Asindicated223211/01/2022BBH       L8U8 1/4" = 1'-0"A-1.1 1   1/4" = 1'-0"A-1.1 2     REV. NODESCRIPTION OF REV.REV. DATE1UNISEX ACCESSIBLE BATHROOM REVISIONS -RAMP REVISIONS2/15/20232UNISEX ACCESSIBLE BATHROOM REVISION-RAMP REVISIONS -2 ; VERIFIED BEAMS2/28/2023THIS DESIGN AND THE DRAWINGS THEREFORE PREPARED FOR THIS FIRST FLOOR 0" CEILING 7' -4 9/16" EXISTING COLUMNS TO REMAIN -PROVIDE NEW MONOLITHIC ARCHITECTURAL COLUMN COVER BASE CABINETS 10'-6"T.O. COUNTER MAX2'-10"T.O. HALF WALL4'-6"SHIPLAP -ALL FINISHES BY OWNER A.F.F. TO B.O. CEILING7'-4 5/8"9'-5" 1'-1"EXISTING STEAL BEAM TO REMAIN6'-8 1/8"FIRST FLOOR 0" CEILING 7' -4 9/16"7'-4 5/8"MAX2'-10"ACCENT WALL (FINISH BY OWNER)A.F.F. TO B.O. CEILING7'-4 5/8"ACCENT WALL (FINISH BY OWNER) (3) RECEPTION DESKS TOP OF WALL4'-6"EXISTING STEAL BEAM TO REMAIN SUB FLOOR TO EXISTING BEAM 6'-8 1/8"FIN FL TO BEAM OF GYP6'-7 1/2"2'-6"2'-10"2'-6"3'-0"9"MAX - ADA2'-10"TOE KICK 101 FIRST FLOOR 0" CEILING 7' -4 9/16" LOWER-FLOOR -7"HALF WALL4'-0"1 12 WOOD FRAMED RAMP 7"PAINTED METAL RAIL PAINTED POPLAR APRON 1'-0"34"-38"3'-0"18"-20"1'-6"8'-4"FIN FLOOR TO FIN GYP6'-6 7/8"1'-4" 5 A-2.0 1 1'-4" HALF WALL - A.F.F. 48" WOOD FRAMED RAMP -RUBBER TREAD FINISH -1:12 SLOPE MAX (-7" A.F.F.)(0" A.F.F.) NEW WALL OPENING 1 1/2" ROUND PAINTED METAL RAILING (SEE SECTION FOR HEIGHT REQUIREMENTS)RAMP4'-6"CLEAR- HANDRAIL4'-0"HANDRAIL EXTENSION 1'-0" 4 A-2.0 1'-4" HANDRAIL EXTEN. 1'-0" NEW COLUMN - SEE DEMO PLAN 8'-4" 1 1/2" ROUND GALVANIZED METAL RAILING 2 A-2.0 STEP DOWN (-7" A.F.F.) (0" A.F.F.) 3 A-2.0 FIRST FLOOR 0" LOWER-FLOOR -7"SUBFLOOR TO B.O. BEAM6'-8 1/8" (ETR)FIN FLOOR TO FIN GYP6'-6 7/8"1/2"EXISTING FLUSH STEEL BEAM TO REMAINEXISTING STEEL BEAM TO REMAIN 1/2" GYP FINISH ADHERED TO BEAM EXISTING SLAB ON GRADE TOP OF WALL4'-0"2X4 STUD @ 16" O.C. PAINTED, POPLAR APRON 1 1/2' PAINTED METAL HANDRAILS (2) EACH SIDE OF RAMP 1'-6"3'-0"CLEAR BETWEEN RAILS 4'-0" 4'-6" $  1 1/4" - 1 1/2"1 1/2" SHEET NO.JOB NO.PROJECT:SCALE:DRAWN BY:DATE:SUBJECT:833 TURNPIKE ROAD P.O. BOX 104 NEW IPSWICH NEW HAMPSHIRE 03071 ARCHITECTURE LAND PLANNING INTERIOR DESIGN 3D VISUALIZATION THIS DESIGN AND THE DRAWINGS THEREFORE, PREPARED FOR THIS PROJECT, ARE THE PROPERTY OF THE ARCHITECT, BRUCE RONAYNE HAMILTON, ARCHITECTS INC., AND, THE DESIGN AND/OR DRAWINGS MAY NOT BE USED IN WHOLE OR IN PART FOR ANY USE OTHER THAN FOR THE ORIGINAL PROJECT FOR WHICH THE DESIGN AND/OR DRAWINGS WERE PREPARED, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS, INC. NO BUILDING PERMIT SHALL BE ISSUED BY ANY BUILDING DEPARTMENT, UNLESS THIS DOCUMENT BEARS THE ORIGINAL SEAL AND SIGNATURE OF THE ARCHITECT, BRUCE RONAYNE HAMILTON ARCHITECTS INC.Asindicated223211/04/2022BB   H:      L9UA 3/8" = 1'-0"A-2.0 6  A-2.0 8 :&"4 A-2.0 9 :&"4 HALF SWING DOOR NEW TILE & ACCENT TILE FLOORING EXISTING COLUMNS TO REMAIN PROVIDE MONOLITHIC ARCHITECTURAL COLUMN COVER TYP. RECESSED LIGHTING NEW TILE & ACCENT TILE AT RECEPTION NEW VINYL FLOORING HALF WALL @4'-6" 3/8" = 1'-0"A-2.0 7  1/2" = 1'-0"A-2.0 5     1/2" = 1'-0"A-2.0 1    EXISTING BEAM TO REMAIN REV. NODESCRIPTION OF REV.REV. DATE1UNISEX ACCESSIBLE BATHROOM REVISIONS -RAMP REVISIONS2/15/20232UNISEX ACCESSIBLE BATHROOM REVISION-RAMP REVISIONS -2 ; VERIFIED BEAMS2/28/20231/2" = 1'-0"A-2.0 4      1/2" = 1'-0"A-2.0 2    L9 3" = 1'-0"A-2.0 3    ARCHITECTURAL COLUMN COVER THIS DESIGN AND THE DRAWINGS THEREFORE PREPARED FOR THIS