Loading...
HomeMy WebLinkAboutBLDE-22-000986 Commonwealth of Official Use Only � Massachusetts s Permit No. BLDE-22-000986 �" BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:8/20/2021 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 8 DUNSTER PATH Owner or Tenant DWELLY JOSEPH H JR Telephone No. Owner's Address 8 DUNSTER PATH,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No ❑ (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 i 'f Meters New Service Amps Volts Overhead 0 Undgrd •t1 0 ers Number of Feeders and Ampacity �� O Location and Nature of Proposed Electrical Work: Installation of solar PV system. (12 Panels 4.0-4: Completion of the following table 'e®a e oYt Spector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators 3 1 KVA No.of Luminaires Swimming Pool Aboved. [nrnd•- ❑ No.of Emergency g /g� grn l Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal 0 Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE:INSURANCE 0 BOND ❑ OTHER 0 (Specify:) I certify,under the pains and penalties ofperjury,that the information on this application is true and complete. FIRM NAME: SOLAR WOLF ENERGY Licensee: Kyle Zuidema Signature LIC.NO.: 22593 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 771 Washington Street,Auburn MA 01501 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law. But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 Commonwealth of Mcosacfiaeoi6 Official Use Only0.11 G ,� '7 c� �'r � Permit No.C2 0 i ci 2oparimani o`}iro J,rvice y 11 .' BOARD OF FIRE PREVENTION REGULATIONS [Rev. /1 Occupancy] ebb Checked APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Maasacbusetts Electrical Code(MEC),527 CMR 12,00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 8/6/2021 City or Town of: Yarmouth Port.Ma 02675 To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 8 Minster Path Owner or Tenant Joseph Dwelly Telephone No. 508-364-6853 s1. Owner's Address 8 Dunster Path Is this permit In conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Residential Utility Aattltariratlon No. 6048165 Existing Service 1 QQ Amps / Volta Overhead❑ Undgrd El No.of Meters 1 New Service Amps / Volts Overhead❑ Undgrd El No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work:Installation of a 4.02kW roof mounted solar array using 12 Sunpower 335W panels with built in microinverters.Installing an empty meter socket for SMART gen meter V) Completion of the following,table may be waived by the/napector of Hires. ty No.of Recessed Luminaires No.of Cell,-Snap.(Paddle)Fans Tn Trnf TTransformers KVA C osformeVA Qt No.of Luminaire Outlets No.of Hot Tubs Generators KVA t No.of Luminaires Swimming Pool Above ❑ Iner ❑ No.of Units Lighting ¢rod ¢rod Battery Units \ No.of Receptacle Outlets No.of OB Burners FIRE ALARMS No.of Zones Z No.of Switches No.of Gas Burners No.of Detection and F Initiating Devices IQNo,of Ranges No.of Air Cond. Total No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons. KW No.of Self-Contained P Totals: ___ Detection/Alerting,Devices No.of Dishwashers Space/Area Heating KW Local❑Monnectiunicipalon ❑°Min C No.of Dryers Heating Appliances KW Security Systems:• No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: 5,861.16 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 12J BOND 0 OTHER 0(Specify:) I certlb,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Solar Wolf Energy I/� / /) / WC.NO.: 186400 Licensee: Kyle Zuidema Signature IL/L/1 //1/ LIC.NO.:22593A (If applicable,enter"exempt-In the license number line.) / Bus.Tel.No. 508-819-2222 Address: 771 Washington St Auburn Ma 01501 Alt.Tel.No.: 'Per M.G.L.c.147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I ant aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$ GENERAL NOTES SHEET INDEX CONTRACTOR 1. All electrical materials shell be new end fisted by recognized SITE MAP 8 PV LAYOUT PV 1.0 Solar Wolf Energy ,,r�r uarf� electrical testing laboratory ELECTRICAL 1-UNE DIAGRAM_PV 2.0 Address:771 Weatdnaton SL �WOLF Custom made equipment shall have complete test data submitted SYSTEM LABELING DETAIL_PV 3.0 Aubum,MA 01501 ha ENERGY Inc. by the manufacturer attesting to its safety Photo number:(888)8784398 2.Outdoor equipment she1I be NEMA 3R rated or equivalentPROPERTY PLAN PV 4.0 Licensee:B4140672 3.All metallic equipment shell be grounded ded ATTACHMENT LAYOUT PV 5.0 4.Contractor shall obtain electrical permits prior to installation and MODULE DATA SHEET D 6.0 Owner: z # shall coordinate ell inspections,testing commissioning and Property Address: D 7.0 acceptance with the Brent, RACKING DATA SHEETProperty Type utility co.and city inspectors as needed. MONITORING SYSTEM DATA SHEET D 8.0 Parcel Number: YARMM 00 .:1 L:0000 5.The electrical contractor shell verify the exec tlocations of service ATTACHMENT DATA SHEET D9.0 Drawn by: supponesolarpape,work,com points and service sizes with the serving utility company and Date: comply with all utility companies requirements. 07/15/2021 6. Drawings are diagrammatic only,routing of raceways shell be GOVERNING CODES option of the contractor unless otherwise rioted aunt shag be THE INSTALLATION OF SOLAR ARRAYS AND coordinated with other trades. PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH VICINITY MAP(SCALE:NTS) 7. tithe roofmaterial or the roof structure not adequate for PV THE FOLLOWING CODES:installMion,call the engineer of record prim to instagation.The contractor is responsible to vent'that the roof is capable of • 2017 National pechicat Code withstanding the extra weight. • 2015 international Residential Code 8.if the distances for cable nom are different thanshown,the • 2015Intemetionat Building Code contractor shall notify the electrical engineer to validate the wire • 2015/ntemeb'ona/Energy Conservation Code size.Final drawings will be red-lined and updated as appropriate. • 2015 Mechanical Code _ 9.Whenever a discrepancy in quality of equipment arises on the AS ADOPTED BY THE STATE OF MASSACHUSETTS drawing or specifications,the contractor shell be responsible for ALL OTHER ORDINANCE ADOPTED BY THE providing end installing all materiels and services required by the LOCAL GOVERNING AGENCIES strictest conditions noted on the drawings or in the specifications to ensure complete compliance end longevity of the operable system required by the engineer of record. SYSTEM RATING 3 < gp2.n.^1" PHOTOVOLTAIC NOTES: DC a.ozoKw s7c AC 3.851KW STC ..� 1. Rooftop mounted photovoltaic panels end modules shall be tested, """"" � ,.,,,. �..,„ listed end identified by recognised testing laboratory EQUIPMENT SUMMARY 2.Solar system shag not cover any plumbing ormechanical vents 3.Modules and support stmcfures shall be grounded 12 SUNPOWER 335W AC MODULES unless racking hes integrated ground. WITH INTEGRATED MICROINVERTERS 4.Removal of an interactive inverter or offer equipment shall not SATELLITE VIEW(SCALE:NTS) disconnect the bonding connection between the grounding ELECTRICAL INFORMATION electrode conductor and the photovoltaic source and/or output circuit grounded conductors. EXISTING • 5.All PV modules and associated equipment end wiring shell be MAIN SERVICE PANEL BUS SIZE:1 OOA protected from physical damage. 6.Live Pena of PV source circus,end PV output ckwib over 150v toMAIN SERVICE BREAKER SIZE:100A —'' ground shall not be accessible to other than qualified persona MOUNTING SYSTEM: INVISIMOUNT while energized. 7. Inverter is equipped with integrated DC disconnect,thus providing e.a ooedocr protectiond fault , BUILDING INFORMATION copper and 75 deg rated 9.A single conductor shall be permitted to be used to perform the CONSTRUCTION TYPE:V-B mumble functions of do grounding,AC grounding and bonding OCCUPANCY:R3 between AC end DC systems. ROOF:Comp.Shingle 10.Non-current carrying metal parts of equipment shag be effectively Rafter 2 x 8(la 16"O.C. bonded together Bond both ends of raceways. 41 c -e---B Q6 ---., (-22___ ......_ 01009e67 N a SOLAR MODULES INDEX 40188`% - _SunPower MM........................... (E)Mein Meter t/�� Model#X21-335-BLK-E-AC MSP.......(E)100A Mein Service Panel ,/ \,. Q, MICROINVERTER GM.................._(N)Generation Meter W L� E INVERTER TYPE:Micro AC....._........„...(N)30A AC Disconnect zro I so' 12 FACTORY-INTEGRATED pyg,,,,,,,_-,IN1125A PV Sub Panel Model#X21-335-13LK-E-AC(240V)PVSS..........(N)PV Monitoring System ik' JB............................(N)Junction Box t►' -.........................EMT Conduit.........................FAIT Conduit 'so -................................Setback SCALE 3/32"=1'-0" IIIIIMI CONTRACTOR O O Solar won Energy O Address:771 Washington St. Auburn,MA 01501 Phone number.(888)87Bi388 Licensed:&'j8940872 a'ure set„nrx, — _ MSP •lr 0o rl or_a� MM AC PVS6 GM PVS Solar PV Array 12-SunPower 335W AC Modules SITE MAP&PV 12-Integrated Microinverters Pitch:23 Deg LAYOUT Orientation:174 D-• Demo by: weeort@soleeaeemorkoom SaleriNberuyrkor0 DATE:07/15/2021 Joseph DeroBy Minster Peth NOTE: Conduit In attic shall Dunster Path vuemYannwnMA 02873 be minimum 18 Inches from roof sheeting I SYSTEM II AS INDICATED PV1.0 • NOTE:Service Penh dues not contain center fed Main Breaker: (N)PVSB MONITORING SYSTEM t / NONCENTER 100A PV OISTRBT.PANEL MAIN CAl ,---,, 125A,120240V, \� NEMA 3R A.VISIBLE LOCKABLE LABELED MAIN METER MA SMART DISCONNECT / / GENERATION METER to OR LESS FROM UTILITY METER SUNPOWER TRUNK CABLE INSTALL 2M PV 4W KW 120200V 3fb1 t2N1aN I,1'1. EXISTING (2)N72 AWG PV WIRE 2-POLE CRI 1�1�� NONFUSIBLE DISOONNECT 100A MAIN FREE EGC �V- / NEMA 3R INSTALLS AO 2P CB(PV) '� IN THE AIR I G�O INSTALL AT OPPOSITE SERVICE PANEL END OF BUS FROM I-e--14, 120/240V �sy 1I MAIN FEEDFRCB 1P,3W I q. CONTRACTOR 4 t /i 1 NE e. Solar WolfEnerav I" " (2)1/10 AWG THWN/THWN-z e�-/ mom% Addreas:m Washington St O - (1)NSAW30ND Auburn,MA 01501 O tt 1 34'FMT.S FEET / Phone number.(888)878-4395 T� i I` (2)010 MVO THWN?HWN-2 (3)810 AVJG THWM?HWN-2 (3)#10AWGTHWN/THWN-2 GEC LicenseN:B6i0872 (1)N8 AWG GND (1)1/8 AWG GND ((3)N10A1)NBAWWCiGTHWMGNDR HWN-2 (1) AWG GND 12 SUNPOWER 335 WATT MODULES 3/4"FMT 15 FFFT 3/d'FMT 2 FEFT 3/4"FMT 2 FFFT 3t4"EMT-2 FEFT NB 12 SUNPOWER INTEGRATED MICROINVERTERS (E)OROUNDINO ENERGVa.. ELECTRODE SVSTW PV ARRAY RATING :WIRE SIZE CALCULATION , ,BRANCH CIRCUIT BRANCH CIRCUIT Number Modules 12 Type Sunpower AC 335 Watt SPR-X20-335-BLK-E-AC Number OFMicroinverters in Orcuit 12 Number Microlnverters Type Sunpower 335 Watt AC SPR-X20-335-BLK-D-AC 12 Factory-intergroted Microinverten (240V) Microinverter Maximum Output Current(A) 1.31 Location Watts STC,Watts/Module)12*3351020 Branch Circuit Total Current(A) 12 a 1.31'1.25=19.65 Array Currents I-SC N/A A I-MP N/A A Breaker Size Per Branch Circuit(A) 20 Module Voltage V-OC N/A V V-MP N/A V ELECTRICAL 7-LINE FROM JBOX TO PVSUB PANEL DIAGRAM Maximum Continius Current(A)I 19.65 More Than 3 CCCAdjist.Factor 0.8 Adjusted ConductorAmpacity(A) I 19.65/0.8=24.56 Raceway Height From Roof(Temp 39.22=61C) 3 1/2" I N of wire(R BC•2) I 2 Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) Drawn by. 0.71 suowrrdlsaiamaoerworx.am Temp.Demte Factor/max.contlnous current divided ambient tern.Factor(A) 24.56"0.71=34.6 Wire Six from NEC Table 310.35(b)36 I l0AWG SaierPenenvurkcom DATE.'07/T5R021 !FROM PVSUB PANEL TO MAIN PANEL Total Number Of M/croinverters I 12 I Total Amps From All Microlnverters (A) 12•1.31=15.72 Consider Continuous(A) 15.72'1.25=19.65 Jaeaah 0.1Y Temp.berate Factor(0.91 at wall of the Budding)(A) 19.65/0.91=21.59 Wire Size from NEC Table 310.15(6)16 8 onr unum 10AWG 8Dter P.O Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 0.911 Were Yarmouth,MAXo287 eat MAIN PANEL PV SYSTEM AS INDICATED fPV Bockfeed Breaker Size(A) I 20 I Main Breaker(A) I 100 I Main Bus Rating(A) I 100 I Total Amps On Bus(A) 120% I 100+20=120I <=120(A) PV 2.0 LABEL LABEL2 LABEL 3 LABEL4 LABEL LABELS CAUTION CAUTION WARNING'. T LD POI SOLAR DC CURRENT PRESENT ` WARNING, PANEL ONLY {FRSCNNAL ONLI; DURING DAYLIGHT HOURS ELECTRIC_HOCK HAZARD. ELECTRIC SHOCK HAZARD. PVSUR- IFGROUNDFAULTISINDICATED, ' ]oR"zf`+a', DO NOT TOUCH THE TERMINALS. NORMALLY GROUNDED TURN RAPID SHUTDOWN-' TERMINALS ON BOTH THE LINE AND (TO BE LOCATED ON (STICKER TO BE LOCATED ON CONDUCTORS MAT BE SWITCH TO THE LOAD SIDES MAY BE ENERGIZED IN SUB-PANEL ONLY CONDUIT WITH DC CURRENT UNGROUNDED AND ENERGIZED. .OFF.POSITION TO -- TOE OPEN Vosknorl. WHEN SUB-PANEL IS EVERY 4'HORIZONTALLY OR SHUT DOWN PV SYSTEM illIL. 10'VERTICALLY AND 1'FROM AND REDUCE DEDICATED FOR PV ONLY) EACH SIDE OF A BEND) SHOCK HAZARD IN THE ARRAY LABEL LABEL LABEL 9 LABEL 10 LABELII THIS PANEL FED BY SOLAR WARNINGI PV LOAD CENTER SIZED FOR PR AC DISCONNECT INVERTER OUTPUT CONNECTION.DO NOT BREAKERS ONLY OR RENDERED UNABLE AC PHO 10\0114IC POWER SOURCE MULTIPLE SOURCES RELOCATE THIS OVERCURRENT DEVICE TO ACCEPT ANY ADDITIONAL LOADS. CONTRACTOR RACED AC OIITPUT CURRENT:19,65 A MAX (UTILITY 8,SOLAR) N,NDINm_AC OPERATING VOLTAGE Trio vac (STICKER LOCATED (STICKER LOCATED Solar Wolf Enemy INSIDE PANEL INSIDE PANEL (STICKER LOCATED Address:nit Washington St. NEXT TO SOLAR BREAKER) BELOW PV BREAKER) ON THE PV SUB PANEL) Arens r MA trot DIRECTORY Pion umber:(888)878<39e Permanent directoryor Licensee:B-04BaM plaque providing location of service disconnecting means and photovoltaic system disconnecting means,if not located at the same location.(Plaques shall be metal or plastic,with engraved or machine printed letters,or electro-photo plating,in a contrasting color to the plaque.Plaques shah be permanently WOlf attached to the equipmenq or in the required location using an approved method that is suitable to withstand the e es ENERGYps. environment to which it is exposed.Plaques and signage shall meet legibility,defacemet,exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). INVERTER If applicable ' fl O Z ' SUB-PANEL MAIN PVS ANEL •daPPlicabla AC PANEL INTEGRATED • DISCONNECT DC DISCONNECT 'if applicable O ® •If a O PV ARRAY ..,(5 7 11 $ applicable 0 0 Fg410-0 10 — 07 —0 _ 0 MARKINGS.LABELS AND WIRING SIGNS A Purpose:Provide emergency responders with appropriate wamine and guidance with reaped to isolating solar electric system. This can facBtate identifying energized electrical lines that coaled solar panels to the inverter,as these shouts not be cut when venting for smoke removal B.Man Service Disconnect 1.Residential buildings-The marking man be placed within the main service disconnect.The marlring shah be placed outside cover Ifthe main eervioe disconnect is operable with the service panel closed. SYSTEM 2.Commercial buildings-T a meriting shell be placed adjacent to the main swim disconnect slsady visible from the location where the level is operated LABELING DETAIL 3.Merldngs:Verbiage,Format and Type of Material. e.Verbiage:CAUTION:SOLAR ELECTRIC SYSTEM CONNECTED b.Format:White lettering on a red background.Minimum 3/8 inches letter height PS letters Mal be capitalized.Mel or simlar font,non bold. 0.Material:Reflective,weather neuter material suitable for the environment(use UL-989 as standard for weather rating).Durable adhesive materials meet this Dawn by: requirement. sugpoa69salamaperworkcom C.Mamkg Requirements on DC conduit,raceways,endoslrea,cable assemblies,DC combines and junction boxes: SdarPecemrodcam 1.Markings:Verbiage,Format and Type of Material. DATE:07/152021 a.Pecement:Markings shall be placed every 10 feet on an interior and exterior DC anduils,raceways,enclosures,and able assembles, at timer,above and for below penetrations,all DC combines and junction boxes b.Verbiage:CAUTION:SOLAR CIRCUIT Note:The format and type of material shall adhere to"IL V-3b,c"crib*requirement. ......4Joseph Dually .Inverters are net required to have Wuhan marNnpa muv.a... 1.Marking is squired on all interior and exterior DC conduit raceweys,endowaes,able assembhes,end)rowbon boxes,combeer boxes and disconnects. 8 Minster Path 2.The materials used for marking shall be re8xtive,weeyrer resistant materiel suitable for the environment. Wad Yameuth,MA 02673 Minknum 31S"letter height;al upper case ettere Mal or almher font;Red background with white lettering. a,... 3.Marcking shall contain the words:WARNING:PHOTOVOLTAIC POWER SOURCE. PV SYSTEM AS INDICATED 4.Marki g shall be placed adjacent to the main service disoonred in a location clearly visible from the location where the disconnect la operated PV 3.0 N o• LEGEND �' � F MPel WE AC Disconnect 270 1 ter/ so. , PVS PV Sub Panel Joli `' �� a t ry�,� � PVSB PV Monitoring System •��� it '. LArrr�r �� s r, �] \� i� I _ _ Div;f: ; k,If SCALE r 1/32"_1'-0" t � ,: " LF" &i •z \ i +A� ..:z �,\ .T� Aiti^���r� , CONTRACTOR a 11r" •\ �1 ♦r y;rk��* l 1i'R�, hAr/u llC • Solar Wolf Energy rX � r , `a� t�Y` , ,„. irr_ AddressWashingtonac ti' 5 r AUWm.MA 01301 {♦ �•ti if,. f�.� �yl r�l+ LAone number:(a33)a78d396 ,i.,%! f,,�.in/ \�rl54 1 r`._ LkerwN:I3600872 4. 1�r�rIt I _90-6 'tfi'1�.-\' `f1jU4 rc;'fr�y�t�r i `i r �c'e �`V!-. ESOLM M1W.F V. , 4VI�i%��,. ;y ry,�.,-9„ TV:,Hr b• � aY 13 q!f ),01n ' ,*er34:C4 n 4 ifw'r-- .■ C e#`'fi r' tr,.:4.:27.,:.,,,...%-• MP I I I \ wr "-%• / i,��b0S..' PROPERTY PLAN I ��°° I :,It'i1/ I — — bean by —_ wOPoa®tsabmeaerwolkcom 100'-2' DATE: nm DATE:07/15/2021 D� Joseph Daery 8 Dumber Path Nest Yarmouth,MA 021273 PA PV SYSTEM AS INDICATED PV 4.0 MODULES ON ARRAY DESIGN CRITERIA POW#. 'Now Prior to the commencement of work,the contractor shag verify the existing roof and framing Solar Mo. Modules: Module Weight(Ibs) 42.9 conditions.Notify support@SolarPaperwork.com of any Discrepancies prior to starting 12 #Of Modules 12 construction. Aneehmant Rafter 2 x 6 @ 16"O.C. Mao Distributed Load:3 PSF Total Module Weight fibs) 514.8 Prior to the commencement of work,the contractor shall inspect framing for any damage Plywood a Budding Felt :locking Rack Weight(Ibs) 102.96 such as water damage,cracked framing,etc.and notify supportetiSolarPaperwork.com if any � � 1 Layer of Como.SMng DFM2 Total System Weight fibs) 617.76 Issues are found. z x 6 #Of Standoffs 38 These Plans are stamped for structsral code compliance of the roof framing supporting the �, Max Span Between Standoffs(in) 48 proposed PV installation reference only.These plans are not stamped for water leakage.PV Loading Per StandoR(Ibs) 16.25 modules,racking,and attachment components must follow manufacturer guidelines and '' �� Total Area(sq.it.) 216 requirements. / yf! LL Loading(PSF( 2.86 Attachments to be installed in a staggered orientation to properly distribute loads. T CONTRACTOR Solar Wolf Energy Address:7/1 Washington St Auburn,MA 01501 Phone number:(888)878.4398 ® ATTACHMENT Licensee:B-840872 RAIL Rafter 2 x 6 N 16"O.C. CSE50l.ARYWDLF PEGASUS COMP SHINGLE DETAILS NI 0 00 IWM11SPesd Flashing ROOF ASSEMBLY + 1 ' } 51 , iti t { } i , It r k , } I 1 i 1 t � I/r� It } �}1t { {{ { irk is orga t��! : ��_'J Support Block EPDM WASHER '. *OM ATTACHMENT LAYOUT - _- O Dram a by: wgoolfa solaryeger cnl tcom Sola,Pwanycdccwq DATE:07/1Y2071 at - Joseph Dwell( 8 Dumter Path West Yarmouth,MA 02673 Nee ee. PV SYSTEM AS INDICATED PV 5.0 OilSUNPUWER` %-Series:X21.350-BLX ITMITSWIel X20.327.BLK 8 ^s,;r 1, ,- „I a::hi :, X-Series:X21-350-BLK I X21-335.8LK I X20-327-BLK V` CONTRACTOR SunPower°'Residential SulerWottEnergy Address:771 Washington St. AC Module Auburn MA 01501 Phone number(833)B7Bi386 8,It,trfi.al:y fr. .0-,they nx'EG,rox ,y .. . LlceneW&Ba0872 ,,,ateda., ,f ,,erg,e tang.arra-,ee b,ant k an:,lac a.e,. /. MaXtrnum Power.MI bhatlat Des1gn. ENE IIIIIIIMIIIIIIIMIEMIIIIIIIIIIIIIIIIIIII (ice Highest Lifetime Energy and Savings. - . Fundamentally Different. E And Better. i -,;x.. 'un t. 1 «gym. AlbE �..ew.ruw. '� er ... me::nR„w.r Maker,.r..ar,el' ......r.r....,, W Best Reliability.Best Warranty. , MODULE e DATA SHEET AleaecM� Drawn Harwrnx-ter auApo OrtBQadarnaasraoM.com ESdtPanama,XCom , . DATE:07/1Y[021 xe t tram.n , Joaeph 3 _. , B Minstar PeM Nest Yarmouth,MA 02073 vow,at opmraabn = PV SYSTEM AS INDICATED D 6.0 • ' • , , 11111111116 111.1M -- CONTRACTOR . ,`" Resici.ntial Mounting Systnm : Recidential Mounting System Solar Wolf Energy Address(771 Washington St Auburn,MA 01501 3,0 Phone number:(888)878-4396 Licensee:6446672 csar- e erlif AMSOLAR WIXF ' ENFPGY... DeSs, Akt Itr141° 1101111111 c . . . , . P.or. Srooe or',rot.' RACKING DATA SHEET Drawn by: waDoilesdermeAvork.eorn SolaRsoannod0A7A1 . . „ DATE 07/192021 sunpOwer.tonl 0 . . . ; . r , . Joseph Dwely tcrurr•mr. 8 Donates Path West Yarmouth,MA 02673 PV SYSTEM I I SUNP WER SUNP WER' AS INDICATED D 7.0 r • CONTRACTOR Solar Wolf Enemy ~ Padr9 :771 Was ton St. anon•m number:(seal eTBi39a �� w�► License.:asaoen M5pAR WOLF .._.. __ E L LINN _. .. e A v1 a .Y � ..;.. _.ate .... _._. .. ,.- MONITORING SYSTEM ® DATA SHEET .. ... .. , - RC Orewn by: !'"t tNbbort@mla/Wbeta'ork torn f tj - W800rt smarkwm Dare b7itsaoa5 # occ to.vnv ra,.2r l5033ea Joseph Dwelt. es.+.. a}V ( V M R' seerseser OumMr Path Neat Yarmouth,MA 02873 SU }3 A/ �n I PV SYSTEM II AS INDICATED a�(r �/v D 8.0 PEGASUS A BETTER DAY ON THE JOB COMP MOUNT ....‘" ""•••. SOLAR' COMP MOUNT Antl plot.el-ta.n :.<xw�:ropya CONTRACTOR el-talon. ,M,:00h,• 1O mlant h,and pauttottOel t Solar Wolf Enemy um...ae Mrple•rum Admen,: 161Hrgton St. npa. Auden,MA o+sot pb+mtr, Phone number:(888)878-4286 Licensed B 940872 StrmeN}pose deur I •• • qq $0{,AR Yam'Lf for pod Ilai e.Nace kand ever T .nxfro mxnr»a EHERt`Yar_- roneard e° r Vi.a � LFow he. ^kµ I lag ew . t'll m¢n AltorA iimiloopoiiii ,. _.,„... tt-t tt- Ermapsuletirg design i 0 9'":thew above roof deck 0 ,. One-pee dashing with slevebd tons-No Ie pro fes or deck-level EPOM washers to Nil e [e,.q Move I...tall Ad WATERTIGHT FOR LIFEsae PscFcn vscaw ssca-cal Pegasus Solari Camp Mount its cart effective,high-quality option for rail installations on mnpovtian shmge roof:. I. yPe Closed., glen Slot uexa qm anti Designed to last decodes,the one-piece fleshing veth elevated cone means Mery re seer*nothing to fail. ,rvete,,,a e- - - - „a, M ,.J.,.,t,,„..<, ,..:pro k,M.°de.e..n ATTACHMENT ,AllA damn' Annvl.,hne, DATA SHEET 25-yoor 1N er. r �p�S p ot Via., Fm,1T sr.. 4©11' bon,a"t,., r a'n- evn vene Drawn by: . su00on@sdarpapenvoM.com c,.n:Poable am a Sdef1.000 workoom re te.rl r.nx°G.i..u.le nH DATE:07/151021 Lode Con PI not \! Alt In One ha P ck.,qnnd t Or 0M'w'y"' rrnen Joseph Ovallygli awxh,Mlle 8 Dental Palo VVed Yarmouth,MA 02673 IPVSYSTEM I AS INDICATED D 9.0 • A o® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/OLEYYYY) `-" 08/17/2021 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Leib Insurance NAME: (PAC.No.Est): 508-7 92-0411 ,No): 537 Park Avenue EMAIL ADDRESS: INSURER(S)AFFORDING COVERAGE NAIL S Worcester, MA 01603 INSURER A:NAUTILOS INSURED SOLAR WOLF ENERGY INSURER B: INSURER C 771 WASHINGTON ST AUBURN MA INSURER D: INSURER E:LIBERTY MUTUAL INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS' CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE AINSD DMSW/ED POLICY NUMBER X COMMERCIAL GENERAL LIABILITY (MM/�/YYYYI IMMIOD/YYYY) LIMITS EACH OCCURRENCE $ 1,000,000 DAMAGENTED CLAIMS-MADE X OCCUR PREMISES Ea occurrence) $ 100,000 A N NN1207723 06/08/2021 06/08/2022 MEDEXP(Anyoneperson) $ 5,000 PERSONAL&ADV INJURY $ 1,090,000 • GENLAGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 PRO- POLICY JECT LOC PRODUCTS-COMP/OPAGG $ 2,000,000 OTHER: $ AUTOMOBILEUABIUTY COMBINED SINGLE LIMIT $ (Ea accident) ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS BODILY INJURY(Per accident) $ FIRED NON-OWNED PROPERTY DAMAGE _ AUTOS ONLY _AUTOS ONLY • (Per accident $ UMBRELLAUAB _ OCCUR EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION AND EMPLOYERS LIABILITY Y/N PER ER ANYPROPRIETOR/PARTNE WEXECUTIVE R OFFICERIMEMBEREXCLUDED? N/A - E.L.EACH ACCIDENT $ 1,000,000 (Mandatory in NH) WC2-31S-614936-020 08/10/2021 08/10/2022 If yes,describe*under E L DISEASE-EA EMPLOYEE $ 1 r 000,000 DESCRIPTION OF OPERATIONS belowEL DISEASE-POLICY LIMIT $ 1 r 000,000 • DESCRIPTION OF OPERATIONS!LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF YARMOUTH 1146 RT 28 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN S YARMOUTH MA 02664 ACCORDANCE WITH THE POLICY PROVISIONS. • AUTHO-,. T TIVE ®1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo,are'registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents 9 ,�, Office of Investigations l=1 Lafayette City Center bid 2 Avenue de Lafayette, Boston,MA 02111-1750 www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): Solar Wolf Energy Address: 771 Washington St City/State/Zip: Auburn, Ma 01501 Phone#: 508-839-2222 Are you an employer?Check the appropriate box: Type of project(required): 1.►.1 I am a employer with 6 4. 0 I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.0 I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. 0 Demolition working for me in any capacity. employees and have workers' insurance.: 9. ❑Building addition comp.[No workers' comp.insurance required.] 5. 0 We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.]t c. 152,§1(4),and we have no employees. [No workers' 13. otherSolar Installation comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees..If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Leib Insurance Policy#or Self-ins. Lic.#: WC2-31 S-614936-020 Expiration Date: 08/10/2022 Job Site Address: 8 Dunster Path City/State/Zip:West Yarmouth, Ma 02673 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains a nalties of perjury that the information provided above is true and correct. Signature: Date: 8/5/2021 Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(check one): lDBoard of Health 20 Building Department 31:City/Town Clerk 4.0 Electrical Inspector 51:'lumbing Inspector 6.DOther Contact Person: Phone#: 2sl , ° 41 • ? 2f&k '!hiti \2s,2.\\§ m �s � y § o m r. § § J7�.. I © I \ 2 ..0C to 6" : 0 n © r, � \ c2 §z\ n 0 amp m § \ a \ ƒ m. tt �: / «R t \ Att- 3 f,a7;3:- '�, *. �.: -max �� ,,....r. 3 2 �y 4 f✓€}imc '" $ a." ° .. y a x 4 - � r try y , • • • SunPower® X21 -335-BLK-D-AC I Residential AC Module Series Design-Driven Advantages • #1 module aesthetics and efficiency' CS2 • Unmatched module reliability2 SERIES • No electrolytic capacitors • 25-year Combined Power and Product Warranty • California Rule 21 Phase 1 compliant Maximize Value for Roof • Size system for roof, not string inverter • Optimize performance of each module Expand Deployment Options • Complex roofs and partial shading • Small systems Optimize System and Installation Efficiency • System expandability SunPower`°-AC modules,which include a factory-integrated SunPower Simplify& Speed Installation microinverter,provide a revolutionary combination of high efficiency, high • Factory-integrated microinverter reliability,and module-level DC-to-AC power conversion. Designed • Robust,double-locking AC connectors Design flexibility offsite and onsite specifically for use with SunPower InvisiMounnim and the SunPower •• No DC string sizing process Monitoring System,SunPower AC modules enable rapid installation, best- • Fewer installation steps than competing in-class system aesthetics,and intuitive visibility into system performance. systems Intuitive commissioning All this comes with the best Combined Power and Product Warranty in • the industry. Component of Complete System • Built for use with SunPower®InvisiMountlM and the SunPower Monitoring System(PVS5x) Grid Support Utility-Interactive Smart Inverter • Superior system reliability and aesthetics SunPower's new Type D AC module is UL tested and certified to UL 1741 SA and provides advanced smart inverter functions. SunPower Type D AC modules are fully compliant with the California Rule 21 Phase 1 0 requirements,and the Rule 21 grid profile is easily set during commissioning with SunPower PVS5x monitoring hardware. 44 4 sunpower.com t,<,r,,sr,eet S U N P W E R® Fi.:01a,:',:!:,'7,1.,5 ,,' 'fit 4 N `Zi,5 'p5 ', . a 4„t .»S•'z xs s�; f .r 49,,• � e 4 ,� ,r 6 x. ,,' 'g , ' Wt n iY �'- r' - ' - • r"'"." ` `: 'Y w Mt.. ,`'' . . _ 4 .....;•.10/ i tif - '-SunPower® X21 -335-BLK-D-AC I Residential AC Module Series AC Electrical Data3 IEEE 1547a-2014 CA Rule 21' SRD Profile (default settings) min./norm /max. min /nom./max. equency(Hz) 59.5/60.0/60.5 58.5/60.0/60.5 Power Factor 0.99/1.00/1.00 0.85 lead./1.00/0.85 lag. Reactive Power ±169 Var Volt-VAr Voltage @240 V 211.2/240/264 V @208 V 183/208/228.8 V Max.Current @240 V 1.33 A - - @208 V 1.54 A DC/AC CEC Conversion Efficiency @240 V 96.0% @208 V 95.5% Max.Units Per 20 A Branch Circuit @240 V 12(single phase) @208 V 10(two pole)wye Power 320 W,320 VA - - - - No active phase balancing for 3 phase installations DC Power Data Warranties and Certifications SPR-X21-335-BLK-D-AC SPR-X20-327-D-AC •• 25-year limited power warranty Nominal Power`(Pnom) 335 W 327 W Warranties • 25 year limited product warranty Power Tolerance +5/-0% +5/-0% UL listed to UL 1741 SA 1 Avg.Panel Effic ency' 21 0% 20.4% • SRDs:IEEE 1547-2003,IEEE 1547a-2014,CA Temp.Coef.(Power) -0.29%/°C Rule 21 Phase 1 •Three bypass diodes • PV Rapid Shutdown Equipment Shade Tolerance • Integrated module-level maximum power point - Equipment Grounding tracking • UL 6703,UL 9703 Connectors and cables (load break disconnection) Tested Operating Conditions • UL 1741 AC Module(Type 2 fire rating) 1 Operating Temp. -40°F to+185°F( 40°C to+85'C) H Certifications Enables installation in accordance with: Max.Ambient Temp. 122°F(50°C) •( NEC 690.E Max.Load Wind:62 psf,3000 Pa,305 kg/m2 front&back NEC 690.12 Rapid Shutdown,(inside and Snow: 125 psf,6000 Pa,611 kg/m'front --I outside the array) Impact Resistance 1 inch(25 mm)diameter hall at 52 mph(23 m/s) "--- -" -- ----- ! • NEC 690.15 AC Connectors,690.33(A)-(E)(1) Mechanical Data FCC and ICES-003 Class B Solar Cells 96 Motalline Maxeon Gen III When used with InvisiMount racking(UL 2703): •High-transmission tempered glass with anti Integrated grounding and bonding Front Glass _ ___• Class A fire rated reffective coating PID Test Potential-induced degradation free Environmental Rating Outdoor rated ___--- Frame Class 1 black anodized(highest AAMA_ rating) + 280 mm? g Weight 45.5 Ibs(20.6 kg) pt.°21") Recommended Max. ,■��■ -�- Module Spacing 1.3 in.(33 mm) .�. 1107mm J V■■..,.. Fm Highest of over 3,200 silicon solar panel Photon Module Survey,Feb 2014 [4361n] 10� Cl rank u V Module Durability Initiative Public Report Fraunhofer C.E,Feb 2013.Roe out of �' • �'■■' [4121o1 �� ■■' i- Feb 201 3 paper,trempe' lrlargestr anufacnuer weretertrd Campeau Z.efal.' unPo,neNvlodule �� ; Dept Rate,';arPower'white p p acorn/fasts �.■ mm.See www,;unpowe'. for details. �.- :r (12In] factory set to 1 547a 2014 default settings.CA Rile 21 default settings prufile set during �■ F See the Equ or,+i n lotion 6utrte 418101 for more'r information 'Standard esr . �.I f -- - �t�WPMrommissiot'r Conditions j1000✓�/n�sirrdiarreAM1. '~- t5°C),tiR�Lcalibra[icc standard 1558mm (6731n1. -i aroaararrunnr ---._-- ____-_ _..-__ ►nand ',ACC r and voltage All DCvoltage is fully contained within the'nodule rvwowrmanm r)h-carte nr "Based on.average of'measured power values during production. LISTED Please read the safety and IPstallationinstructtons for details. Module Flnp .Typs2 gee owv a p,wer-or fcts for more reference infom"'atlon. For more details,see extended rlatasheet evwwsunpower.corm/datasheets. 513983 Pm, ii I'1 di i ,1 t�,l I � V 1 �It r N P W E R®