HomeMy WebLinkAboutBLDE-22-002355 Commonwealth of Official Use Only
.s . l i I Massachusetts Permit No. BLDE-22-002355
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/25/2021
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below,
Location(Street&Number) 27 ERICKSON WAY
Owner or Tenant BERNER KIM E Telephone No.
Owner's Address 27 ERICKSON WAY, SOUTH YARMOUTH, MA 02664
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters,
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (21 Panels 7.04 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alertine Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal 0 Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: SOLAR WOLF ENERGY
Licensee: Kyle Zuidema Signature LIC.NO.: 22593
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 771 Washington Street,Auburn MA 01501 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
( Lftr\is �cLOD
C°ntmonu�oa�o ii/aeeachueetle Official Use Only
1 ,fr,
'R _ c� Permit N
•-:Nero, aeparintenl el ire�erviced
,4,,
i';' 3' Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07) (leave blank)
iAPPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
c� All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
- (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 10/21/21
City or Town of: Yarmouth To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 27 Erickson Way S.Yarmouth Ma 02664
Owner or Tenant Kim Berner
Owner's Address 27 Erickson Way S. Yarmouth, Ma 02664 Telephone No.213-220-4394
Is this permit in conjunction with a building permit? Yes
Pu of ElNO ID (Check Appropriate Box)
7 rPose Building Residential Utility Authorization No. 6608722
V Existing Service 200 Amps 120/240 Volts Overhead X❑ Undgrd 0 No.of Meters 1
New Service Amps / Volts Overhead
Number of Feeders and Ampacity ❑ Undgrd 0 No.of Meters
Location and Nature of Proposed Electrical Work: Installing a 7.04kW roof mounted solar array using
21 SunPower 335W panels with built-in microinverters and installing an empty meter socket for SMART qen meter.
Completion of the followin,g table mf be waived by the!�e Inspector of Wires.
No.of Recessed Luminaires No.of Cell:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets
No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above (—I In- No.of Emergency Lighting
grad. grad. ❑ Battery Units
No.of Receptacle Outlets No.of Oil Burners
FIRE ALARMS INo.of Zones
No.of Switches No.of Gas Burners No.of Detection and
No.of Ranges Initiating Devices
No.of Air Cond. Total
Heat PumpTons No.of Alerting Devices
Number Tons KW No.of Self-Contained
No.of Waste Disposers
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal
No.of Dryers Connection 0 Other
tY Heating Appliances KW security Systems:*
No.of Water No.ofo.o No.of Devices or Equivalent
Heaters KW
Si s Ballasts Data Wiring:
No.HydromassageHeaters Bathtubs No.of Devices or uivalent
No.of Motors Total HP a ecommun ca ons rum:
OTHER: No.of Devices or E aivalent
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: 10 932.60
Work to Start: (When required by municipal policy.)
Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ❑x BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties ofpe1/ury,that the information on this application is true and complete.
FIRM NAME: Solar Wolf Energ
Licensee: Kyle ZuidemaL LIC.NO.:t g64_00
(If applicable,enter exempt in the license number line.) Signature j(� � ,. LIC.NO..
Address: 771 Washington St Auburn Ma 01501 259
Bus.Tel.No.:50 4 A-�2_
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Alt.Lie TeNo.:
L
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage n— ort lly
required by law. By my signature below,I hereby waive this requirement. I am the(check one owner owner's a ent.
Owner/Agent
Signature
Telephone No. PERMIT FEE: $
GENERAL NOTES SHEET INDEX CONTRACTOR
T. All eedrical materials shad be new end listed by recognized SITE MAP S PV LAYOUT pry i,q ��,�N OF y4s4 Solar wog Energy
electrical testing laboratory ELECTRICAL I-LINE DIAGRAM_PV 2.0 Z* Sit Address:771 Waslwpron St
I SOLARWOtF
Custom made equipment snap have complete test data submitted -7n Auburn,MA 01501 ' ..k ENERGY j r.
SYSTEM LABELING DETPJL PV 3.0. IWOIAYANE518 Phone number.088)878-396
by the manufacture rattesting to is safety PROPERTY PLAN PV 4.0 G CML Licensee:B 940672
2.Outdoor equipment shall be NEMA 3R rated or equivalent
..s b
3.All metallic equipment shell be grounded ATTACHMENT LAYOUT PV 5.0 Kle.55892
4.Contractor shall obtain electrical permits prior to installation and MODULE DATA SHEET D 6.0 ;:lik..' Own,: Kim Berner
shell coordinate al inspections.testing commissioning and L Property Address: 27 Erickson Way South Yarmouth,MA 02664
acceptancewith the client, RACKING DATA SHEET D 7.0 Property Type: Single Family Residence
uONy co.and city inspectors as needed. MONITORING SYSTEM DATA SHEET D 8.0 Parcel Number: YARMM:0101B:00134L:0000
5.The electrical contractor shall verily the exact locations of service ATTACHMENT DATA SHEET D 9.0 Drawn by New@eginearinc.io
points end service sizes with the serving unity company and Date:
comply with all ditty companies requirements. Date Ce a 09/302027
6.Drawings are diagrammatic only,reeling of raceways shall be GOVERNING CODES Signed:9/30/202
option�� s. �otherwise noted and shall THE INSTALLATION OF SOLAR ARRAYS AND VICINITY MAP(SCALE:NTS)
7. Ii the rontmffierialorme roof structure not adequate for PV with other trades
PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH
instigation call the engineer of record print to installation.ilea THE FOLLOWING CODES:
contractor is responsible to verify that the roof is capable of • 2017 National Electrical Code ..
withstanding the extra weigh. • 2015 International Restdeno'al Code
8.If the distances for cable nos are different than Mown,the • 2015 International Building Code
contractor Mall notify the electrical engineer to validate the will, • 2015 International Energy Conservation Code
Woe.Final drawings will be and-hired and updated as appropriate. • 2015 Mechanical Code
9.Whenever a discrepancy in quality of equipment arises on the AS ADOPTED BY THE STATE OF MASSACHUSETTS
drawing or speN6catccns,the contractor shag be responsible for ALL OTHER ORDINANCE ADOPTED BY THE
providing and installing all materials and services required by the LOCAL GOVERNING AGENCIES ,.
strictest conditions noted on the drawings orin the specifications rv,F;;,;,.,,.
to ensure complete compliance end longevity of the operable
system required by the engineer of record.
SYSTEM RATING
PHOTOVOLTAIC NOTES: DC 7.03Kw src
AC 6.41KW STC
1.Rooftop mounted photovoltaic panels and modules shag be tested, o.
listed and identified by recognized testing laboratory EQUIPMENT SUMMARY
"-"
2.Soler system Meg not cover any plumbing ormechanical vents
3.Modules and support structures shag be grounded 21 SUNPOWER 335W AC MODULES
unless racking has integrated ground. WITH INTEGRATED MICROINVERTERS
SATELLITE VIEW(SCALE:NTS)
4.Removal of en irderective inverter o other equipment shall not
disconnect the bonding connection between the grounding ELECTRICAL INFORMATION
electrode conductor and the photovoltaic source and/or output
sirs&grounded conductors. EXISTING
5.All PV modules and associated equipment and wiring shag be MAIN SERVICE PANEL BUS SIZE:200A
protected from physical damage. MAIN BREAKER SIZE:200A
6.Live parts of PV source circuits and PV output circuits over 150vto
ground shall not be accessible to other than qualified persons MOUNTING SYSTEM:INVISIMOUNT
while energized. VI"` -ea
7.Inverter is equipped withintegrated DC din•„.-et,gas providing R.
ground fault protection BUILDING INFORMATION 1
8.All conductors shag be copper and 75 deg rated
9.A single conductor shag be permitted to be used to perform the CONSTRUCTION TYPE:V-B
multiple functions of dc grounding,AC grounding and bonding OCCUPANCY:R3
between AC end DC systems. ROOF:Comp.Shingle
10.Non-current carrying metal pads of equipment shag be electively Rafter 2 x 8I l 24"O,C. "`;�j.. «.
bonded together.Bond both ends of raceways. §`
•
u,,.[
ENGINES INC =
Engineerinc.io.
303 N Glenoaks Blvd Suite 200
Burbank.CA 91502
(747)333-5991
pewBDenoineerinc.ig
NOTE:Service Penal does not contain center NO Mein Broker
(N)PVSB MONITORING
SYSTEM
Line Side Tap
-PV DISTRBT.PANEL
7i
NON-CENTER 2 a.\\
125A 0V, MAIN VSI - L
NEMA MA 3R 3R (/\e"
VISIBLE LOCKABLE LABELED MAIN NETER
DST MA SMART
to OR LESS FROM UIILRY METER GENERATION METER
SUNPOWER TRUNK CABLE INSTALL(2)20A PV FUSIBLEsoscoBOA II^^'' EXISTING;'
(2)Y12 AWG PV WIRE 2-POLE GB 1 OL5CONNECT 400 KW 120240V rI^-----`� 200A MAIN I
(1MBEGC I -W- , . NM SSA FUSES NEMA 3R I- •� SERVICE'.
FREE IN THE AIR 1 O PANEL
\ i- iP.3W
X, i i CONTRACTOR
i �1
NEW. I - j Solar Wolf Energy
/- L_ , I Addrew:771 Washington St
*song as (4)#10 AWG THWWTHWM-2 Auburn,MA 01501
as aria (i)#B AWG ONO f/ Phone number: 8194396
1 hill
aiii as ! (41)•EMT 5 FEET LkereN:9e40672
G Tamar
3i/wri i�� (4)010 AWG THWWTHWN-2 (3)08AWG THWWTHWN-2 (3)08AWGTHWNRHWN-2 (3)08 AWG THWWTHWN-2
GEC
(1)#BAWGGND (i)YB AWG GND (1)#B AWG ONO (1)08AWGGND .may,
O3(4"FMT 45 FFET 14"EMT.2 FEET 314"EMT,2 FEET 3I4 EMT 2 FEET y 1)EMEG WaF
li
(E)GROUNDING s fENEHGVYc
III
a � e.�P. ELECTRODE SYSTEM
21 SUNPOWER 335 WATT MODULES
21 SUNPOWER INTEGRATED MICROINVERTERS
PV ARRAY RATING WIRE SIZE CALCULATION
BRANCH CIRCUIT-A BRANCH CIRCUIT-A
Number Modules 11 Type SunpowerAC335 Watt SPR-X20-335-BLK-E-AC Number OFMcroinverters in Circuit 11
Number Micralnverters Type Sunpower335 Watt AC SPR-X20-335-BLK-E-AC Mkroinverter Maximum Output Current(A)
11 Factory-intergrated Microinverters 1.31
Location Watts STC,(Watts/Module)11.335=3685 Branch Circuit Total Current(A) 11•1.31"1.25=18.01
Array Currents 1-5C N/A A I-MP N/A A Breaker Size Per Branch Circuit(A) 20
Module Voltage V-OC N/A y V-MP N/A V
BRANCH CIRCUIT-B BRANCH CIRCUIT-B
Number Modules 10 Type SunpowerAC 335 Watt SPR-X20-335-BLK-E-AC Number OF Microinvetters in Circuit 10
Number Microlnverters Type Sunpower335 Watt AC SPR-X20-335-BLK-E-AC Miuoinverter Maximum Output Current(A) ELECTRICAL 1-LINE
10 Factory-intergroted Microinverters 1.31 DIAGRAM
Location Watts STL,(Watts/Module)10.335=3350 Branch Circuit Total Current(A) 10.1.31•1.25=16.37
Array Currents ISC N/A A I-MP N/A A Breaker Size Per Branch Circuit(A) 20
Module Voltage V-OC N/A V V-MP N/A v ENGINEEZINC
FROM JBOX TO ENPHASE COMBINER BOX
Drawn brWewOeryrNMruc.Ja
Maximum Continius Current(All 18.01 More Than 3 CCCAdjist.Factor 0.8 Adjusted ConductorAmpocity(A) I 18.01/0.8=22.51 °ATE:09/302021
Raceway Height From Roof(Temp 39+22=61C) 31/2" I#of wire(#BC•2) I 4 Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) I0.71 On Berner
Temp.Ovate Factor(max.continuo current divided ambknt tem.Factor(A) 22.51/0.71=31.70 Wire Size from NEC Table 310.1516)16 I 10AWG s..s
FROM ENPHASE COMBINER BOX TO MAIN PANEL So South
Yarm Way
ko Way SOWI MA OZ6R4
Taal Number OfMkroiayenen I 21 'Total Amps From All Microinverters (A) 21•1.31=27.51 Consider Continuous(A) 27.51•1.25=34.38 I 1 I,d. I
PV SYSTEM AS INDICATED
Temp.Devote Facror(0.910l wall of the Building)(A) 34.38/0.91=37.78 Wire Size from NEC Table 330.35(b)16 8q WG
Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 0.911 - PV 2.0
NO• LEGEND
40'�` MM Main Meter
�... MSP Main Service Panel
���'��Q; / —' '- ., AC AC Disconnect
a1 a
W �' E s PVS PV Sub Panel
nO - so• �yon I PVS6 PV Monitoring System
,lit,
; , �� 4'-4 �\ \. GM Generation Meter
4
�OIR IOW. - .�-' DIiv way '' f. -:
ENGINES INC
SCALE 1/16"=1'-0" .'a 1�I �
— t/e — �,�5�'a, tA1(r Engirleednc.ro,
'Sry 1 t '� 303 N Glenoaks Blvd Suite 200
, Aalv)lr 'Ails 7)?-,., 'tet,/ilfrr£S Burbank,CA 91502
', <�ls< � �` AP alb (747)333-5991 CONTRACTOR
, .rra•C„ is It y�° �� ;!, neeeenameedncao
,«� 9 ^ ' ; 1r�.r.,itnli:. Solar Wolf Energy
\ ,9 "-' .4.K11 Address:771 Washington SL
e/". . 1
61-7" \..,\ .�-7' °E 'N, --OPERTY L NE Phone hewn,MAnum o1�er(9a8)d78d�6
\ �U.L..•" ,�.. license*:B-B106T2
A
a�,
.S6
'%eE t'*, 12:,-4„ ('�souw WOLF
M ` � , a "-"yENERGYee
— Ilk
�,g AI Vei
E.
,, ;;;' �a No.5 ee
5892
1v ..
K i,,e Dale Ce' a
F Signed:9/30/202
\, `ram , e 1t rf Nt!
d ' h ��/ r PROPERTY PLAN
\ I. <>/i� s� o ` ENGINEERING
\ s y,c l 'r -'0 .,.01 Drawn ey: naneednsio
\ 10 ' ` ^�'� QU , 'I -_41Me,., DATE.'09/30/2021
s
I ,. �� ,o Kim Berner
7 Y \
AN
T ?
/' j , I 's , Cn '' Erickson VVey
SOWi YaimoWn,MA o26Bd`r, n:i.V I PVSYSTEM I I AIN DICATED� '
Al' PV4.0
. :.
(111/ SUN POWER %Series.X21.350-SLK I X21-33S411.K I X20.327.BLK ,1`,- Aor P o A 'A A 1.. .,..
, X-Series:X21-350-BLK I X21-335-BLK I X20-327-8LK CONTRACTOR
k Solar Wolf Sacral/
SunPower Residential Addles.Tit Washington St
Aubuni MA 01501
AC Module Miens number 01813)8784398
License*B-940672
A e,itAis APio tie.ogred Aof,eto,lar.1,,anoo o[,A iod,orm
0)imm
, Maximum Power Minimalist Design ENERGY
'erre
a.
11111111111111117711111111. 1.111111111111111111111111111111111111111111111,
L37,31 Highest Lifetime Energy and Savings
Fundamentally Different i
And Better.Illift .
111111111111111111EIMMININIIIIIIII ,,
g Best Reliability Best Warranty.
• -
_
MODULE
,
-
. . DATA SHEET FA.A•oryintegra•AuNlerroinvoo, f ENGINEERINC
i.
Drawn by Newetenglneednc 92
a
• • DATE 09130/2021
Kin Benter
,.., .
SUNPOWER'........,....„.... 27 Dickson Way
South Yalmoidh,MA 02864
IPV SYSTEM I I AS INDICATED I
D 6.0
., _._. +t
_._ 4 .a'' ., -' ! ; .l. ' Rec;drnrlat and Carnm'rctal f,VS6
CONTRACTOR
Re,idential and Cani(1(' . l f'V56
,• Saar war Ener9Y
_ t ,••, Mhe. 771 W.lgim St.
ii ')V Auburn,MA 01501
Phone number(888)878-4396
`". Licensee:B-940872
I
. ,proSOLAR WOLF
Mill Y..n..<:m,�,;. t CISENPPG7
.
MONITORING SYSTEM
,:... ., DATA SHEET
.
Ff•. r O ENGINEERINC
� •�� Drawn by:Nee en.neenno.M
FCC tD:rMYleb17 1393W - DATE OP/302021
..' i
.gr e
10m Berner er
..F.� ..,,... :: .. SUNP VCQL 27Ecmom Was
South Yarmouth,MA 02864
UN P WE l+j1\x I PV BYSTEM I AS INDICATES
S ii. D 8.0
A�?�0 0/21
CERTIFICATE OF LIABILITY INSURANCE lDATE �Y)
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER CONTACT
Leib Insurance PHONE I FAX
(NC.No.Eat): 508-792-0411 I(A/C.No):
537 Park Avenue EMAIL
ADDRESS:
INSURERS)AFFORDING COVERAGE NAIC#
Worcester, MA 01603 _______.._.._____....._.._.....---- _-----'----._...-'------.._--_--
INSURER A:NAUTILUS
INSURED
INSURER B:
SOLAR WOLF ENERGY
INSURER C:
771 WASHINGTON ST __---___.------------------------'---------..__..__..._.--
INSURER D:
AUBURNMA -------...-------'-'----- -.-_..-------'--'---
INSURER E:LIBERTY MUTUAL
INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO AU.THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR , IADDL SUER -.._......__..__._..._..........._...._.__.rrrr-POLICY EFF-T POLICY E%P -____._-'---'-'--__._ ....-_--__-'-__ _--
LTR - TYPE OF INSURANCE INS° WVD POUCY NUMBER (MMIDD/YYYY)I(MMIDD/YYYY) UNITS
X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE i$ 1,000,000
-OANIFGi'rO�E=NTEO.—. ._.--._--.---........
I CLAIMS-MADE IX l OCCUR PREMISES(Ea occurrence) $ 100,000
A N NN1207723 06/08/2021 06/08/2022 MED EXP(Any one person) $ 5,000
_ M - PERSONAL&ADV INJURY $ 1,000,000
GEN'L AGGREGATE LIMIT APPLIES PER: I GENERAL AGGREGATE $ 2,000,000
POLICY EEC j LOC PRODUCTS-COMP/OPAGG $ 2,000,000
OTHER: $ _
AUTOMOBILE LIABILITY h1 COMBINED SINGLE LIMIT $
(Ea accident)
ANY AUTO I BODILY INJURY(Per person) $
OWNED I- !SCHEDULED • BODILY INJURY(Per accident) $
AUTOS ONLY I AUTOS
HIRED NON-OWNED PROPERTY DAMAGE $
_AUTOS ONLY I AUTOS ONLY (Per accident)
$
— UMBRELLA UAB I OCCUR EACH OCCURRENCE $
EXCESS LAB CLAIMS-MADE - ! AGGREGATE $
DED RETENTION$ _ $
WORKERS COMPENSATION PER OTH-
AND EMPLOYERS'LIABILITY STATUTE ER
Y/N ANYPROPRIETOR/PARTNER/EXECUTIVE N/A I E.L.EACH ACCIDENT $ 1,000,000
OF FICERIMEMBEREXCLUDED? Y
F ! Mandatory In NH) WC2-310-614936-020 08/10/2021 08/10/2022 E.L.DISEASE-EA EMPLOYEE,$ 1,000,000
If yes.describe under
i DESCRIPTION OF OPERATIONS below E.L.DISEASE-POUCY LIMIT $ 1,000,000
I I I
DESCRIPTION OF OPERATIONS!LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached if more space is required)
CERTIFICATE HOLDER CANCELLATION
TOWN OF YARMOUTH
1146 MA-28 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
S YARMOUTH MA 02664 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED-EPRESENTATIVE
•
(I,1, , l 1/
5 ORD CO ORATION. All rights reserved.
ACORD 25(2016/03) The ACORD name and logo are registered ma s of ACORD
PEGASUS A BERES DAY ON THE JO8 COMP MOUNT
1.04 p.Aot Foie Jr. 4.COMP MOUNT °Moon APO,s CONTRACTOR
-0 shape'of u..110.1 .
Solar Wolf EMMY
do 6 Address:ni WuNeN0on SI
...me`mem,. Auburn,MA 01501
vs 11.... Phone number.(WS)878-4396
Lemma:El-940672
en SOLAR WOLF
STmple3-pece Maven .•-• a ; 0,,,,..,,,,INERGYk...
for raad onallanon 3.1,4e1.-Fiao“.ver 4....a..ly K.,...q.o..ci
.-one...el oF....I,
' —_——
Encapr.ulavng d.ign I estmenom .
ousea the wane seal
I 0 9",ebovs roof deck i . . 1
One-pece dock-level YE flashing with eievamd cone
. ,
;
' I ' . •
press.fin or EPDM washer:to do 0 i
. 1
R.'00 SPCR,VI
WATERTIGHT FOR LIFE L.I 't 1,p.. Closr....lot 0,9, (:,../1 SlotPegasus Sole;Come Mount,s a cost effective,legn.qualrly optsfor rea.nsMllatons on comp Metgle mon on
Desugned to last decades Ma one-pmce noshing with elevated cone means them is sorely nothing to NI
''''''''Pq ..':';'W.'1"lZi O',.','o ..,'t::,:tta:Zafa'ar, ..,..',7;=',.,';,';`,;',.'.•.',L'o'oi, ATTACHMENT
2005 eia,.t,cot and R/r/N,V, DATA SHEET
0 25.yeat War,anty Su peraur Waterproofing ltoo ,onyloe.tni,Shirx)1,
.a,1A,kan.x. ENGINEERINC
Con,,de Reel Drawn brNewOonginserincTo
L.,I,,,P/13I,1,1 Parnles1,,,,ane 2, DATE 09/30/2021
CdCmpl oe oiant .0.10,., All In On e Kit Packaging
nom,Niel /2 ....././././
i0111 Ben.'
.....,......
27 Erickson Way
South Yarmouth,MA 02664
nem mao
PS SYSTEM AS INDICATED
D 9.0
• r
I,-----s.'.. .4.:,-ifi--RAI--5-kii,,,KWot,,,t.li'14''.-*,:'-'-`'-'-;'' ;.'"!..-'''''.---'7;=--i.:-'---.-=.---' ' .. -- F'''' '1-<,.. -'',---....-::•-!-,'-'„'2,:'''',..7;=.-,t'-','-' '''',1:-',.- -•.,-. ...,--z-,4,-.'..--,-,,,..--,-...- ---. _.- , .,
•--- .=',...,',X'''''71-T"'.--.1....,-'-t-01,1-7,..';.".-:,--..',,,-;--,.-....,--,.-'f.--- . -..:-<,:-.:.., - ,..,--,.. .s.-----.... ....-- • ,. r-- , =.-',...;- .---i-,".-7-' . . - - -' - ' .... , ';.,..."--,-;:.,..„,s„;,‘ ' „_--- : '.,.., ,
,.• - ., -
• ....64111117.._. _ •. ,r.•'.•'r
•Ad Iddlir..r V
.
' '.• .1.
't t r
''''''''''S'r:'L,:*rrrr'r.',,,,,,'• _,441,*,,,,,,r.r•r — CONTRACTOR.., -----. ,,,_,,,,,,,,.
.. ,
.. .
r,,, ^.1.)_,[1::' i Residential Mounting System ,----,iiiipo„,,,cri. ir,isily1;-,‘„ii:1— i Residential Mounting System Solar Wolf Energy
Address:771 Weelanrrion Et
Auburn,MA 01501
Phone lumber Mari 6034396
LS.n48#8-840672
ream'"
<
111111
04
1121))ENERGYIne.
k k_
Are
—*"- '""."" Iti.""411* WWII
.$
.., -
k '
, r.r r , • .
[' '
,...... ... . ___ ......----...., - - RACKING
DATA SHEET
1 . -
ENGINEEaINC
Drawn byNenreenginewinc.lo
i
.' SUDDOW9r.corn DATE 09/30/2021
Kin Samer
27 Erickson Way
, r r
South Yammulh,MA 02664
I PV SYSTEM I
SUNP WER* SUNP WER* II A:INDICATED
D 7.0
4 r
MODULES ON ARRAY DESIGN CRITERIA POINT Lam)CALCuisno 4PER ARRAY Prior to the commencement of work,the contractor shall verify the existing roof and framing
SolarModules: Module Weight fibs) 42.9 conditions.Notify New@engineerinc.to of any Discrepancies prior to starting construction.
Mo
21 #Of Modules 21 Prior to the commencement of work,the contractor shall inspect framing for any damage
Attachment Rafter 2 x 8 @ 24"O.C. Max Distributed Load:3 PSF Total Module Weight(Ibs) 900.9 such as water damage,cracked framing,etc.and notify New@engineerinc.io if any issues
Pywcod s Building Fe Rack Weight Ilbs) 180.18 are found.
of
DF82g Total System Weight(Ibs) 1081.08 These Plans are stamped for structural code compliance of the roof framing supporting the
1 Layer of Coin.sN 2,10 #Of Standoffs 40 proposed PV installation reference only.These plans are not stamped for water leakage.PV
Max Span Between Standoffs(in) 48 modules,racking,and attachment components must follow manufacturer guidelines and
Loading Per Standoff fibs) 27.027 requirements.
Total Area(sg.R) 378 Attachments to be installed in a staggered orientation to properly distribute loads.
Loading(PSF) 2.86
L ENGINES INC
S Engineerinc.io,
303 N Glenoaks Blvd Suite 200 CONTRACTOR
Burbank,CA 91502
(747)333-5991 Solar Wolf Energy
newebenoineerinc jq Addren:771 Washington St
Auburn.MA 01501
Phone number:(nett)87134396
0 ATTACHkENT ucensea:13a40672
L._ ____ __ RAIL
.. _. ..... ..... _ Rafter 2x 8@24"0.C. ESOLFRGYWDLF
inc
PEGASUS COMP SHINGLE DETAILS
.0,0OFkds,,
UghtMosd Flashing ROOF ASSEMBLY * IIANOI CHDIR Y�
-ti
�i NAIOIANAIRSItI
CML
i%'` No.55892
+ 1 o
Signed:9/30/202
�a WO - ATTACHMENT
Support abck EPOM WASHER O �. • ��., LAYOUT
lI [5 Q_ ENGINEERINC
Drawn ey.Neww@engineedneio
DATE:09/30/2021
Kith Bomar
27 Elicksan Way
South Yarmouth,MA 02884
PV SYSTEM AS INDICATED
PV 5.0
LABEL 1 LABEL 2 LABEL 3 LABEL 4 LABEL LABEL 6
CAUTION CAUTION WARNING' PV SUB-PANEL ONLY
WARNING' s.�'q,�y,z 4°,m'• H y-^'�,
AUTHORIZED SOLAR SOLAR G CURRENT PRESENT EROUNDOSHOCK HAZARD. ELECTO NOT RIC SHOCKHAZARD.
PERSONNALONLY`. DURING DAYLIGHT HOURS IFGROlRMALLY GROUNDED TURN
2 A D � � � DMINALS ON BOTH TERMINALS.AN (TO BE LOCATED ON
NORMACTORS MAY BE ITCH SHUTDOWN LOAD TERMINALSRAH BEN THE GI LINE AND
(STICKER TO BE WITH DC
LOCATED T CONDUCTORS EN RE SWITGNTOTNE LOAN SIDES 5 MAY POSITION.ENERGIZED DIN SUB-PANEL ONLY
CONDOR MATRON CURRENT UNGROUNDED AND ENERGIZED. ^OFDOWNPVOYST THE OPEN WHEN DFOR NEON
IS
EVERY 4'HORIZONTALLY OR SHUT DOWN PV SYSTEM DEDICATED FOR PV ONLY)
TM VERTICALLY AND 1'FROM AND REDUCE
EACH SIDE OF A BEND) SHOCK HAZARD
IN THE ARRAY
LABEL LABEL6 LABEL9 LABEL IO LABEL 11
WARNING! PV LOAD CENTER SIZED FOR PV
AC DISCONNECT THIS PANEL FED BY SOLAR INVERTER OUTPUT CONNECTION.DO NOT BREAKERS ONLY OR RENDERED UNABLE CONTRACTOR
AC PHOTOVOLTAIC POWER SOURCE MULTIPLE SOURCES RELOCATE THIS OVERCURRENT DEVICE TO ACCEPT ANY ADDITIONAL LOADS.
RATED AC OUTPUT CURRENT:34.38 UMAR (UTILITY B SOLAR) Solar Wolf Energy
NOMINAL AC OPERATING VOLTAGE.DAT Vac (STICKER LOCATED (STICKER LOCATED (STICKER LOCATED Address:771 Warinaten St.
INSIDE PANEL INSIDE PANEL ON THE PV SUB PANEL) Auburn,MAo1so7
NEXT TO SOLAR BREAKER) BELOW PV BREAKER) PhoneAubur,MA 01(ees)6m-aou6
DIRECTORY Licensee::B810672
Permanent directory or plaque providing location of service disconnecting means and photovoltaic system
disconnecting means,if not located at the same location.(Plaques shall be metal or plastic,with engraved or /[1'��
machine printed letters,or electro-photo plating,in a contrasting color to the plaque.Plaques shall be permanently ►..p6NERGYYi�OLF
attached to the equipmenq or in the required location using an approved method that is suitable to withstand the
environment to which O is exposed.Plaques and signage shah meet legibility,defacemet,exposure and adhesion
requirements of Underwriters Laboratories marking and labeling system 969(UL969).
INVERTER
41111
If applicable
�� MAIN SERVICE
SUBfANEL
r-I L I 7 if aPDtCD - AC PANEL
PV S ANEL DISCONNECTINTEGRATED . O O
///(J BOX DC DISCONNECT N applcable ]O ® 'if applicable 7 12
PV ARRAY I O _O Q 10_O ,(O O O O Il)
MARKINGS,LABELS IL AND WIRING SIGNS
A Purpose:Provide emergency responders with appropriate wemkrg and guidance 0Yh respect to isolating solar eledrie system.
This an facilitate identifying energized electrical trues that corned solar panels to the inverter,as these should not be out when venting for smoke removal
B.Min Service Disconnect.
1.Residential buidngs-The marking main be placed within the main eerdee disconnect.The marking shall be placed SYSTEM
outside aver lathe man service disconnect is operable with the service panel dosed. LABELING DETAIL
2 Commercd1 buildings-The mar4ng shall be placed egacent to the main service daareed dearly visible from the location where the level is operates
3.Markings:Verbiage,Format and Type of Material.
a.Verbiage:CAUTION:SOLAR ELECTRIC SYSTEM CONNECTED
b.Format:Pride keering on a red background.Minimum 3)13 inches letter height Al letters shall be capitakmd.Mal or sunder fee,non boM.
c.Material:Reflective,weather resistant materiel suitable for the environment(use Lit-9os as standard for weather rating).Durable adhesive materials mad this CNGINEC421NC
C.Marki rent Drawn byNewtheeploeerirw.a
C.1.arl Regdremants on conduit,Tyraceways,te arctmaurea,able assembles,DC combiners and junction boxes: DATE 09/302021
1.Placement
Verbiage,Format and ed of Material. ,y,,,,
a Placement:Markings alai be Paced every Toted on ad interior and exterior DC conduits,raceways,enclosures,and able assembles,
at and,above and for below penetrations,al DC combiners and junction boxes i�
rner
b.Verbiage:CAUTION:SOLAR CIRCUIT Note:The format and type of material shall adhere to V.V-3b,c-oldie requirement. 27 Enckwrh Way
c Inverters are not required to have caution markings south Yarmouth,MA 02864
1.Mamkng is required on al interior and exterior DC medial raoeways,endosuees,able assembti a es,end junction boxes, mbiner boxes and deconrects.
2.The materials used for marking daft be rellective,weather resistant material suitable for the envianmert PV SYSTEM I AS INDICATED
Minimum
3/8 letter height;al upper case letters Mal or driller font Red background with white lettering.
3,Meroarg shall contain the words:WARNING:PHOTOVOLTAIC POWER SOURCE. O\/3.0
4.Marking shad be placed adjacent to the main service dscannect in
a location dearly visible from the location where the domct a sce operated r V
o•
SOLAR MODULES INDEX
,,4/ ),` 21 Sun Power MM..........................._(E)Main Meter
/� Model INVE 35-BLK-E-ACMIC MSP.......(E)200AMain Service Panel
W I/ O, E iNVRTERTPER net
l� INVERTER TYPE:Micro
NO �" 21 FACTORY-INTEGRATED PVS (N)126A PV Sub Panel
90• PV56..........(N)PV Model#X21-335-BLK-E-AC(240V) Monitoring SystemGM....................(N)Generation Motor
............................(N)Junction Boy
.........................EMT CorMutt
S
.........................FMT Conduit
180 ................................Setback
SCALE: 1/8"=
yNaY
Enak50 PVS6 CONTRACTOR
� PVS
AC Solar Wog Energy
Address:T1 NheNrpton St
GM Auburn,MA 01501
Phone rsareer.(888)8784396
License/Or 8-9403 2
MSP
oLL.k.
ESNO RGYWOI.F
tU�6res�c �arV � • \
3•fltiz- ♦ �'N
y 1/firms • . -�� .
oo . . . �a0
o so . . . �o
. . ao
3.ago
Solar PV Array
\ 21-SunPower 335W Modules SITE MAP 8,PV
21- Microinvertens LAYOUT
Pitch:27 Deg
Orientation:163 Deg
ENGINCERINC
Drawn bYNe v@enpnsedneJo
DATE 09/30/2021
Kim Berner
ew"r.rti
27 Erickson Way
South Yarmouth,MA 02664
NOTE: Conduit in attic shall e._
be minimum 18 inches from roof sheeting PV SYSTEM 31NdCATED
PV 1.0