Loading...
HomeMy WebLinkAbout15 Southwest plans 11SEAMLESS METAL ROOF (COLOR BY OWNER) NEW FRONT DOOR AWNING (SEAMLESS METAL ROOF) FIRST FLOOR TOP PL, 7' - 6 1 /2" NEW WHITE CEDAR SHINGLES (TO MATCH EXISTING) MARVIN ULTIMATE LOW-E ALUMINUM CLAD WINDOWS �i FIRST FLOOR _ 01-011 PROPOSED FRONT ELEVH I IU N FJLAN 1 /4" = 1'-0" ARCHITECTURAL ROOF SHINGLES \IG VG (COLOR TO MATCH EXISTING) - EC FASCIA - - - - NEW I X 8 AZ K ... _ - - - . -_ -- t1 ' ,' t TO MATCH EXISTING - NEW ARCHITECTURAL ROOF SHINGLES r T (COLOR TO MATCH EXISTING) �, � ;, � ----- � - � --- _ NEW ALUMINUM GUTTERS DOWNSPOUTS — u _ -�� __ NEW ALUMINUM GUTTERS k DOWNSPOUTS - 5 SECOND FLOOR TOP PLATE SECOND FLOOR TOP PLATE �I ;_ - -- -- ---- - — 12' 0 3/4" NEW FASCIA BOARDS - 12' - 0 3/4" 6" X 6" PRESSURE TREATED COLUMNS TO MATCH EXISTING --- -- - - WRAPPED IN WHITE AZECK SLEEVE _ J NEW CORNER BOARDS TO MATCH EXISTING 1 - -- - - - PVC RAILINGS -4L — —FIRST FLOOR TOP PLIU2 7' -6 Wojcik Construction Co., Inc. MARVIN ULTIMATE LOW-E - - ALUMINUM CLAD WINDOWS - �1 3-SEASON TOP PLATE _ -- _ __ -- SECOND FLOOR 15 Southwest Drive 5' ' S 1 /2" COMP051TE DECKING _ - —_ 4' - 6 1/4" S. Yarmouth, MA ON RUBBER MEMBRANE (PITCH MEMBRANE TOWARD OUTER EDGE) - - _ BASEMENT TOP PLATE /1 NEW COMPOSITE DECK NW/ PVC RAILINGS T 31 - 7" EXISTING 3-5EA50N ROOM TO REMAIN L__ ___ __ FIRST FLOOR ______ 0' - 0" Proposed Elevations 3-SEASON FLOOR — — FOUNDATION 3-SEASON FLOOR — �I -1' - 6 1 /2" — — 6 1 /2 _ _ — — _ _ I _ Project number 22-004 I I I I_ 1 I_ Date 4/6/2022 I I I f—III III III III III III III 1 1 1 —III—III III —III III III I I l III —III I I 1 III III III III —1 Drawn by MJB i I I —I I I I I III I I 1 1 I 1-1 I I I I III I i—III Checked by MJB A-1 0 3 MASTER BEDROOM ELEVATION 2 PROPOSED LEFT ELEVATION PLAN - Scale 1 /4" - 1'-0" 1 /4 - 1 -0 1 /4" 1'-0" - GENERAL NOTES No. Description Date 1 Full Draft (NOT ISSUED FOR CONSTRUCTION) 4/6/2022 2 Revised per Customer Email Dated 4/18/2022 (NOT ISSUED FOR CONSTRUCTION) 4/26/2022 5 ISSUED FOR CONSTRUCTION 9/1/2022 These plans are for the construction of one budding only and are not to be coped in any form without the expressed written consent of Burden Professional Drafters. The design of these plans have been reviewed by Burden Professional Drafters. it 15 the responsibility of the contractor(s) * owner(s) to review the drawmgs for errors or omissions prior the start of the project. These plans are to be used in conjunction with other construction documents (i.e. professional engineered site s structural plans, construction specifications; etc). The contractor(s) * owner(s) shall not scale these drawmgs, visual dimensions supersede any scaled dimensions. Any discrepancies shall be brought to the attention of Burden Professional Drafters for review prior to the commencement of the protect. The general contractor shall not scale drawings for measurements, but shall. verify on Site that all levels * measurements for complete assembly and mstallation of their work are correct. Minor details of the work not specifically shown on the drawmgs shall be assumed by the contractor on site in conjunction with the buildmg code and local code t, laws in mind. THE ARCHITECTURAL DESIGNER NAMED HERON IS RESPONSIBLE FOR THE CONCEPTUAL PLANS AND DETAILS ONLY AS SHOWN IN THIS PLAN SET * 15 NOT LIABLE POP THE COST OR CONSTRUCTION Of THE BUILDING SHOWN HERON. THE BURDEN COMPANY Professional Drafting Services PO Box 26 Raynham Center, MA Phone- (508) 967-6460 Fax: (508) 692-9505 www.burdendrafters.com -0'-10" FINISH GRADE