HomeMy WebLinkAbout15 Southwest plans 7II III
III III
III EXI5TINGDECK TO BE REMOVED
III � III
LuI III
L I1
IIII I
II
i II
DEMO * RE -FRAME EXISTING
FRONT WALL TO NEW LAYOUT
DEMOLITION F1RST FLOOR
III I I
III I
III I
NI I
.III I I I I Il � II I I III II ICI
DEMO EXISTING 3-5EA50N ROOF
�F�I =I IH
LIJ;I ttl
�111�� LLU
REMOVE REPLACE III
ALUMINUM GUTTERSJLLLL
NI I I IIII
ui aI Ii — = = -- _ — ——�— —
a III I I
Ill I 11 Hill 1 11 1 1�_. i ' — — — — — — — — �
- ( 1 REMOVE FRAMING
FOR NEW OPENING
I I RE -FRAME AS REQUIRED
_—)II
D I FOR NEW WINDOWS —
DEMO EXISTING BATHROOM TO STUDS
RE -FRAME ACCORDING TO NEW PLANS
� I L
I,
121Ll
DEMOLITION SECOND FLOOR
3/16" = 1'-0"
GENERAL NOTES
No.
Description
Date
1
Full Draft (NOT ISSUED FOR
CONSTRUCTION)
4/6/2022
2
Revised per Customer Email Dated
4/18/2022 (NOT ISSUED FOR
CONSTRUCTION)
4/26l2022
5
ISSUED FOR CONSTRUCTION
9/1/2022
6
Adjust 3-Season Room Dimension
12/22/2022
These plans are for the construction of one building only and are not to be
coped in any form without the expressed written consent of Burden
Professional Drafters. The design of these plans have been reviewed by Burden
Professional Drafters. It is the responsibility of the contractor(s) * owner(s) to
review the drawings for errors or omissions prior the start of the project. These
plans are to be used in conjunction with other construction documents (i.e.
professional engineered site * structural plans, construction specifications, etc).
The contractors) * owner(s) shall not scale these drawmge, visual dimensions
supersede any scaled dimensions. Any discrepancies shall be brought to the
attention of Burden Professional Drafters for review prior to the commencement
of the project.
The general contractor shall not scale drawings for measurements, but shall
verify on site that all levels $ measurements for complete assembly and
installation of their work are correct. Minor details of the work not specifically
shown on the drawings shall be assumed by the contractor on site in conjunction
with the building code and local code � laws in mind.
THE ARCHITECTURAL DESIGNER NAMED HERON 15 RESPONSIBLE FOR THE
CONCEPTUAL PLANS AND DETAILS ONLY AS SHOWN IN THIS PLAN SET s 15
NOT LIABLE FOR THE COST OR CONSTRUCTION OF THE BUILDING SHOWN
HERON.
THE BURDEN COMPANY
Professional Drafting Services
PO Box 26
Raynham Center,. MA
Phone: (508) 967-6460
Fax: (508) 692-9505
www. burdendrafters. com
Wojcik Construction Co., Inc.
15 Southwest Drive
S. Yarmouth, MA
Demolition Plans
Project number 22-004
Date 4/6/2022
Drawn by MJB
Checked by MJ B
A-6
Scale 3/16" = 1'-0"