Loading...
HomeMy WebLinkAbout15 Southwest plans 7II III III III III EXI5TINGDECK TO BE REMOVED III � III LuI III L I1 IIII I II i II DEMO * RE -FRAME EXISTING FRONT WALL TO NEW LAYOUT DEMOLITION F1RST FLOOR III I I III I III I NI I .III I I I I Il � II I I III II ICI DEMO EXISTING 3-5EA50N ROOF �F�I =I IH LIJ;I ttl �111�� LLU REMOVE REPLACE III ALUMINUM GUTTERSJLLLL NI I I IIII ui aI Ii — = = -- _ — ——�— — a III I I Ill I 11 Hill 1 11 1 1�_. i ' — — — — — — — — � - ( 1 REMOVE FRAMING FOR NEW OPENING I I RE -FRAME AS REQUIRED _—)II D I FOR NEW WINDOWS — DEMO EXISTING BATHROOM TO STUDS RE -FRAME ACCORDING TO NEW PLANS � I L I, 121Ll DEMOLITION SECOND FLOOR 3/16" = 1'-0" GENERAL NOTES No. Description Date 1 Full Draft (NOT ISSUED FOR CONSTRUCTION) 4/6/2022 2 Revised per Customer Email Dated 4/18/2022 (NOT ISSUED FOR CONSTRUCTION) 4/26l2022 5 ISSUED FOR CONSTRUCTION 9/1/2022 6 Adjust 3-Season Room Dimension 12/22/2022 These plans are for the construction of one building only and are not to be coped in any form without the expressed written consent of Burden Professional Drafters. The design of these plans have been reviewed by Burden Professional Drafters. It is the responsibility of the contractor(s) * owner(s) to review the drawings for errors or omissions prior the start of the project. These plans are to be used in conjunction with other construction documents (i.e. professional engineered site * structural plans, construction specifications, etc). The contractors) * owner(s) shall not scale these drawmge, visual dimensions supersede any scaled dimensions. Any discrepancies shall be brought to the attention of Burden Professional Drafters for review prior to the commencement of the project. The general contractor shall not scale drawings for measurements, but shall verify on site that all levels $ measurements for complete assembly and installation of their work are correct. Minor details of the work not specifically shown on the drawings shall be assumed by the contractor on site in conjunction with the building code and local code � laws in mind. THE ARCHITECTURAL DESIGNER NAMED HERON 15 RESPONSIBLE FOR THE CONCEPTUAL PLANS AND DETAILS ONLY AS SHOWN IN THIS PLAN SET s 15 NOT LIABLE FOR THE COST OR CONSTRUCTION OF THE BUILDING SHOWN HERON. THE BURDEN COMPANY Professional Drafting Services PO Box 26 Raynham Center,. MA Phone: (508) 967-6460 Fax: (508) 692-9505 www. burdendrafters. com Wojcik Construction Co., Inc. 15 Southwest Drive S. Yarmouth, MA Demolition Plans Project number 22-004 Date 4/6/2022 Drawn by MJB Checked by MJ B A-6 Scale 3/16" = 1'-0"