Loading...
HomeMy WebLinkAboutVariance Request, Application, Plans, HearingINSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE PROPOSED 1,500 GALLON TWO -COMPARTMENT - 10" REINFORCED CONCRETE 4" SEPTIC TANK (H2O, WATEMOFFD) r =3tu MAX. COVER 3' MIN. COVER 1' 7' OF 4' SCH 40 PVC S=1 %- 1,4.25 4.15 0.25 LEVEL INSTALL OUTLET TEE AND BASE OF ZABEL FILTER (A1800) 6" CRUSHED STONE 3' WIDE GEOFAB SILT r- 1 " x 1 " x 3' OAK STAKE FENCE FABRIC OR APPROVED EQUAL - N 6" GROUND LINE SILT FENCE/LIMIT OF WORK BARRIER DETAIL DETAIL NOT TO SCALE EDGE OF PAVEMENT x BENCHMARK • NOT TO SCALE 4.5 / 5.86 00-FOOTMAG NAIL SET IN PAVEMENT UP ELEVATION=3.51 (NAVD88) \ i BUFFER ; ;' TO BVW ` ? S 82'49'15" W I ` 00 CRESCENT COURT / BVW A I ��� 76, WG 38�.64' 40' WIDEN' LIMIT OF 1"OVERDIG t ` 361 / AND 40 MIL HDPE!BARRIER / x BARRIER ELEV. 2.1 TO 6.7 BVW Al 50-FOOT £ x 5.61 LIMIT OF SJUN f i BUFFER PR POSED 14.5' X 41.0' I m �..�TO BVW / PIF� IN STONE LEACH FIELD / CB/DH SPECTION (p ESSURE DISTRIBUTION) S(FND) PORT - o �5.2� _. - - r5 BOTTOM OF 00, %fri , i ' 41.0' } S�QST 1 ; i l !!1 titi GROUNDWATER MONITORING 'HELL �pQG TOP OF MONITORING WKLL CASING L S ELEV.=8.00' I c� c��yytiFO n i I (NAVD88) i �r ( 6 IP II m C) / I• 6.61 + EXISTING LEANING BVW A2 I CLEANOUT I -� x 11.5't PITCH PINE TREE 3.46 SILTATION BARRIER _ (np, OF 2 6.1 fi' ! - - �" - TO BE REMOVED (SEE DETAIL) / I 4.2' � �- - - _ - 10' MIN I x 6.04 TO / - o o i TP -1 i 6.20 ORIFICE LOCATION z i 4- (TYP.) PROPOSED 1,500 GAL -TWO-COMPARTMENT 6.37 REINFORCED CONCRETE WETLAND AREA RELOCATE WATER LIN . I % _-� PROPOSED 1,000 GAL m SEPTIC TANK (H20) (TIDAL) 10-FEET LATERAL SEPARATION-1 REINFORCED CONCRETEz TO TANKS AND ISAS REQUIRED. i PUMP CHAMBER (H20) TO BE SLEEVED% IF SEPARATION i CANNOT BE MET / .85 WILLOW STREET N � s CR�OUR T SITE LOCUS SCALE 1"=1000' w z 0 5 J 3' TOP OF FOUNDATION ELEVATION=11.25 I I80' OF 4' SCH 40 PVC (LONGER RUN) LL S=2% MIN. 6.25 IXISTING 4.50 SYSTEM PROFILE NOT TO SCALE CLEANOUT TO z GRADE THREADED 1 1/2" SCH 40 PVC WITH 1/4" "' END CAP PERFORATIONS IN THE TOP OF o THE PIPE (SPACING SHOWN) J 5' 5' 3' 2" SCH 40 PVC 45' BEND MANIFOLD 1/4" ORIFICE WITH ORENCO MAXIMUM 2" SCH 40 PVC ORIFICE SHIELD FORCEMAIN FROM PUMP CHAMBER 1-1/2" PIPE TO BE RUN LEVEL PRESSURE DISTRIBUTION INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE PROPOSED 1,000 GALLON REINFORCED CONCRETE 10" PUMP CHAMBER (H2O. WATERPROOFED) EL.=3.90 U w (773 GALLONS) Z CD tY 0 w w ALARM ON EL.=0.73 4" PUMP ON EL.=0.40 If 6" Q z uj ¢ w PUMP OFF EL.=-0.10 0 w 6" m Ln i MIN. COVER 9" (TYP.) 'S ------------------------------- SLOPEJ= 40' OF 1-1/2" PERF. SCH 40 PVC S=0.000 (SEE PRESSURE DISTRIBUTION DETAIL) 3/4"-1 1/2" DOUBLE WASHED STONE 41.0' LONG BY 14.5' WIDE LEACHING BED INSTALL RISERS TO BRING COVERS TO WITHIN 6" OF GRADE 2" THREADED UNION ---2" BALL VALVE `-STAINLESS STEEL LIFTING CHAIN OR CABLE " WEEP HOLE 2" CHECK VALVE r- 2" SCH 40 PVC RISER PIPE MYERS SRM4 4/10 HP PUMP OR APPROVED EQUAL PUMP CHAMBER DETAIL '•OT TO SCALE OBSERVATION WELL READINGS TP- 1 DATE MME ELEVATION 0== 10/23/22 10:OOAM 1.70' (2 HRS BEFORE HIGH) HTM 10/27/22 2:50PM 2.13' (NEW MOON) m FILL 10/29/22 8:30AM 1.95' (1.5 HRS BEFORE LOW) ;� 1 1 /5/22 1 1 :20AM 1.70' (HIGH TIDE) z 11/12/22 8:OOAM 1,90' (1 HR BEFORE LOW) Z) FRONT DOOR X' /�, / . 5.63 LIVING ROOM BEDROOM BEDROOM BVW A3// %` Z 2.67 Q UPPER LEVEL DINING F� KITCHEN BATH BEDROOM FXI S TING D WELLING ` I o _j_ 1 ;EM ` ! TOP OF FOUNDATION EL = 11.25 (NAVD88) GM1 FOUR -BEDROOM SPLIT LEVEL STYLE HOME i I � r 1 ; 5.72 m 1 BVW A4 1� I z 1 'i I EX DECK I I LOWER LEVE 1 COrri mil 1 t O I I WETLAND AREA �'' EXISTING TANK y 1 i � / o � (TIDAL) / ! 0 t -(TO BE BACKFILLED I 1 ; r -I AND ABANDONED �, EXISTING AC L.J OR REMOVED) CONDENSER AND / I( - _ _ _ - _ I APPROXIMATE LOCATION ` r + - x O I OF AC CONDENSER BVW A5 EXISTING DECK ; 6.42 � LINE TO DWELLING 00 BVW A5A \ I EXISTING LEACHFIELD ` ` c 3.13 \ \ / i (TO BE ABANDONED) I 1 n m� \ I ' rLn - 6.00 I I � I x4.65 CB/DH(FND) x I ELEV.=5.22' Fi m x 4.17 \ L - - - - _ _ 5.22_ _ _ J (NAVD88) Q N/F N 82' 14' 10" E 298.00' DAWN D STECIUK 145 SOUTH STREET 1 MAP 34, PARCEL 266 x 3.98 x 4.41 LIVING ROOM LIVING ROOM FRONT DOOR UTIL I BEDROOM CLOS UTIL I BATH EXISTING FLOOR PLAN NOT TO SCALE 58" C MEDIUM SAND 1OYR 5/2 60" - 112" 8 oz. NDN WOVEN GEOTEXTILE FABRIC 00 MINIMUM ELEV.=7.63 ------ --- ELEV.=6.63 v v v v v v v a v v v v vvv ELEV.=6.13 4' SEPARATION ELEV.=2.13' OBSERVED HIGH GROUNDWATER SITE INFORMATION ADDRESS: 7 CRESCENT COURT, SOUTH YARMOUTH MAP/PARCEL: 34/268 DEED REFERENCE: CERT. 999179 GENERAL NOTES: 1. THE SUBJECT PROPERTY IS WITHIN A FEMA ZONE AE12 AS SHOWN ON PANEL NO. 25001 CO589J, EFFECTIVE DATE JULY 16, 2014. 2. THE SITE NOT IS LOCATED WITHIN A ZONE II AREA. 3. VERTICAL DATUM IS NAVD88 4. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE REGULATIONS AND LOCAL BOARD OF HEALTH AND BUILDING DEPARTMENT REGULATIONS. 5. ALL JOINTS IN THE TANK/PUMP CHAMBER AND DISTRIBUTION BOX SHALL BE MADE WATERTIGHT THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC CEMENT. 6. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO ANY EXCAVATION OCCURRING. 7. LOCATION OF UTILITIES ON THIS PLAN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD. THE ELEVATIONS OF ALL EXISTING SEWER INVERTS SHALL BE VERIFIED PRIOR TO THE INSTALL OF ANY SYSTEM COMPONENTS. ANY DISCREPANCIES SHALL BE REPORTED TO THE DESIGN ENGINEER IMMEDIATELY 8. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR TO BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF INSPECTIONS 9. WHERE APPLICABLE, UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. 10. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 11. EXISTING CONDITIONS SURVEY PERFORMED BY PAUL E. SWEETSER, PLS, OCTOBER 2022 DESIGN CALCULATIONS DESIGN FLOW 110 GALLONS/DAY/BEDROOM X 4 BEDROOMS = 44-0 GALLONS/DAY TANK CAPACITY 440 GPD X 200% = 880 GALLONS, USE 1,500 GALLON TANK REQUIRED LEACHING CAPACITY DESIGN PERC RATE = < 2 MIN/INCH 440 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 594.59 SQ. FT. 6.20 PROVIDED LEACHING CAPACITY BOTTOM AREA = 14.5' X 41.0' = 594.50 SQ. FT. (440 GPD) PUMP NOTES 1. USE MYERS MODEL SRM4 4/10 HP PUMP OR APPROVED EQUAL 1.36 2• BOTH VISUAL AND AUDIO (AUDIBLE AND LIGHT) ALARMS ARE TO BE LOCATED WITHIN THE DWELLING AND BE POWERED BY A SEPARATE CIRCUIT FROM THE PUMPS 3. ELECTRIC JUNCTION BOX SHALL BE EXPLOSION PROOF NEMA 4X AND SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER IN A SEPARATE STRUCTURE. ALL ELECTRICAL CONNECTIONS - OBS.=1.20 SHALL BE LOCATED OUTSIDE THE PUMP CHAMBER 4. PUMP SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURERS SPECIFICATIONS AND TITLE 5 REGULATIONS. 5. THE PUMP SHALL BE ABLE TO BE REMOVED FROM THE PUMP CHAMBER WITHOUT ENTERING THE STRUCTURE 6. THRUST BLOCKS SHALL BE INSTALLED AT ALL BENDS IN THE FORCEMAIN 0.4 7, AN ELECTRICAL PERMIT IS REQUIRED FOR THE INSTALLATION OF THIS SYSTEM SOIL PROFILE DATE: OCTOBER 25, 2022 PERFORMED BY: RICK JUDD WITNESSED BY: JAY GARDINER PERC RATE:<2 MIN./IN. SEIVE SAMPLE TAKEN FROM C-LAYER FTHREADED END CAP TO GRADE ---------------- SOLID PE 8 I OZ. NON H DETAIL NOT TO SCALE PUMP CHAMBER VOLUMES 1. PUMP CHAMBER VOLUME = 244 GALLONS PER FOOT OF HEIGHT 2. VOLUME DOSED PER PUMPING CYCLE = 116 GALLONS OR 0.50' (6') (INCLUDING DRAIN BACK) 3. EMERGENCY STORAGE = 773 GALLONS OR 3.17' (38") 4. DOSES PER DAY = 4 BUOYANCY CALCULATIONS 1,500 GALLON SEPTIC TANK (H-20) VOLUME OF TANK IN WATER = 11.0' X 6. 0' X 6.1' = 402.6 C.F. 402.6 C.F. X 62.4 LBS/C.F. = 25,122 LBS UPLIFT WEIGHT OF SOIL = 6.0' X 11.0' X 62 LB/FT2X 0.75' = 3,069 LBS DOWNFORCE WEIGHT OF EMPTY SEPTIC TANK = 23,000 LBS DOWNFORCE TOTAL DOWN FORCE = 26,069 LBS DOWNFORCE 1,000 GALLON PUMP CHAMBER (H-20) VOLUME OF TANK IN WATER = 9' X 5,25' X 6' = 283.5 C.F. 283.50 G.F. X 62.4 LBS/C.F. = 17,690 LBS UPLIFT WEIGHT OF SOIL = 5.25' X 9.0' X 62 LB/FT2X 0.75' = 2,929 LBS DOWNFORCE WEIGHT OF EMPTY SEPTIC TANK = 17,250 LBS DOWNFORCE TOTAL DOWN FORCE = 20,179 LBS DOWNFORCE LEGEND PROPERTY LINE EXISTING CONTOUR 104 PROPOSED CONTOUR - EXISTING FENCE EXISTING OVERHEAD UTILITIES W - EXISTING WATER LINE G EXISTING NATURAL GAS LINE TP-1 LOCATION OF TEST PIT/PERC TEST 99.76 X EXISTING SPOT ELEVATION QFH EXISTING FIRE HYDRANT -0- EXISTING UTILITY POLE ® WG EXISTING WATER GATE BOX BH BULKHEAD CH CHIMNEY -0 GM EXISTING GAS METER 0 IP PROPOSED INSPECTION PORT 8 oz. NON WOVEN GEOTEXTILE FABRIC 1-1/2" PERFORATED SCH 40 PVC PIPE 9" MIN. EARTH ( EARTH BAC�KFI4,) / BACKFILL 8" DEPTH OF 3/4" TO 1-1/2" DOUBLE WASHED CRUSHED STONE 4'-8" 5'-2" 4'-8" 14'-5" LEACH FIELD CROSS SECTION NOT TO SCALE REQUESTED HEALTH VARIANCES: MAXIMUM FEASIBLE COMPLIANCE • 310 CMR 15,212 (1) - DEPTH TO GROUNDWATER - MINIMUM VERTICAL SEPARATION FROM BOTTOM OF SAS TO HIGH GROUNDWATER SHALL BE 5 FEET. BOTTOM OF SAS IS LOCATED 4 FEET ABOVE HIGH GROUNDWATER. A VARIANCE OF 1 FOOT IS REQUESTED. • YARMOUTH REGULATIONS SECTION (3.7) - THE LOCATION OF A LEACHING FIELD SHALL NOT BE LESS THAN 100 FEET FROM A WATERCOURSE... SAS IS LOCATED 54.2 FEET FROM THE EDGE OF THE WETLAND. A VARIANCE OF 45.8 FEET IS REQUESTED. A 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 PHONE: (508) 400-2365 SITE DESIGN, LLC r1 Residential Site Design and Permitting LOCATION.• 7 CRESCENT COURT SOUTH YARMOUTH, MA 02640 - -- - CL/ENT ROY GARDINER FEB 161023 64 HIGH ROAD HEALTH DEPT. BUCKHURST HILL IG9 5RW, UK DRAWING TITLE SUBSURFACE SEWAGE DISPOSAL SYSTEM SITE PLAN AND PROFILE SCALE.• DATE DRAWING NO. 11/2/2022 1 of 1 ONI \, 19nd Local peptic variaro,es. Bu:r�,t =r review and approval NO. DATE and tulurc art,lrUrrns/r� tiil .aly Cations to scwakc tarilitica :uul/or strut�'uri I t i �7 L2�s Date