Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot Zone of Contribution: In Out Acreage Commercial: Residential: Street: Villag /C I � � _S-e Floor Plan: # Bedrooms: 2_ Owner: Installer: 13 3 4ic C.r v,,--t;0 w Address: Phone: Phone: Builder: Engineer: Address: 4 w-r,., Phone: Phone: N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table e/ 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: I 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: [/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: V,.• 1 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: I I 15. System not in top or subsoil (A,B horizons)or 5' removal / 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred _J8. System meets breakout requirements PVC liner: Wall: I `/ 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal d" 22. System adequately sized for its intended use I ` 23.Minimum 6"stone or compacted below tank and dbox !� 24. Manhole covers within 6"of grade, pump chamber cover to grade �I 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexesi. 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size !f 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking t 30. Buoyancy calculations for tank/pump chamber I ✓ I 31. Engineer to inspect and certify soils: wall: commercial: I - 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V 33.H-20 loading is subject to vehicular traffic,groundwater ,-/-v 34.Title V Application and permit fee, installer signature / 35. Foundation footing min. 2 feet above adjusted ground water for new house ./ 36. Deed Restriction required max. #bedrooms: max. flow: gpd I 37. Check area lots for groundwater/Label groundwater in Assessor's Map I Plan reviewed by: T