Loading...
HomeMy WebLinkAboutEngineer PlanctAAAAA•; 'v0sa" O Inn o 5 0 * IThe Optimist cafe 4sta: 9 1„aho Japanese f Jack's Outback LOCUS MAP Note: EXISTING SAS IS IN APPROXIMATE LOCATION OF PROPOSED SAS. EXISTING SAS TO BE REMOVED TO FACILITATE INSTALLATION OF NEW SAS , + REMOVE & REPLACE-5' ALL AROUND i Note: R ove soil down to el. 88.00 & replace with 11 clean coarse san erc. rate less than or r or equal to 2 min./in. before do after placement r t + J t r 1 r r r J + r r r j , r r J , q r � 1 ' r + , i (o' 1 r r � r r , o 0 20 40 50 SCALE: 1 "=30' . L ZAI (YAR►AsLE --__ RIGHT OF WAY} •• / 04 / / / S / Ar EXISnNG 4072 SF COMMERCIAL BLDG. .;w/2 BR APARTMENT . S 80D 13' r r t , / //TEST HOLE 12 / ELEV.a 99.00 TEST HOLE #1 . ELEV.= 99.00 e • C jai LOT #CIO 44 771 Square P.•t 13FEB M HEALTH DEPT. Illt11f11�'11flill, f NEW / � 2500 gga(, Septic ?4k . 0 2 Comptrt�e TANK / J t i , � J �11 1 1 ~ J� ' 11' V m t t r + r ca r Qi�•/ a J 1 r 1 t PROJECT BENCH MARK TOP OF FOUNDATION ELEV. = 100.00 (ASSUMED) - ExisT'1NG 1000 gal. Septic Tank TO BE REMOVED 910 Yarmouth Health Department .-/- APPROVED , ame .35=� Date GENERAL NOTES 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all underground utilities and pipes. 2. The septic tank and distribution box shall be set level on 6„of 3/4"-1 1 /2 stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Shay Environmental Services 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different 7HEALTH from those shown on the soil fog or in our design installation must halt & immediate notification be made to Shay Environmental Services 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H--20 septic components. 8. Install Tuf--Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is AVAILABLE. ALL PROPERTIES WITHIN 150 FEET ARE CONNECTED TO MUNICIPAL WATER. THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN AT THE BARNSTABLE REGISTRY OF D PLAN BOOK 457 PAGE 37 BY DOWN CAPE ENGINEERING DATE:D: 5/ 11 / 1988 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. EXISTING LEACH AREA TO BE PUMPED OUT AND FILLED IN PLACE NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING SAS ABANDONED AND TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT 161 MAIN STREET PARCEL ID: 122-123-ClO YARMOUTHPORT, MA aeeanaeo BY: CARMEN E. SHAY ENVIRONMENTAL SERVICES P.Q. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508-294--7498 SCALE: 1 "=30' DRAWN BY: CES DATE: DEC 22, 2021 PROJECT#161 MAIN FILENAME: 161 MAIN.DWG SHEET 1 OF 2 EXISTING Foundation ti 10' min. from -- house to septic tank Sffi0.02 v zo' EXIST. PIPE FROM FOLINDATI13N X 6' -2- w H a> 61 SYSTEM PROFILE Not to Scale VENT PIPE rO Least 24 inches *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. Schedule 40 PVC w/Charcoal Odor Filter -Grade over optic Tank - 99.W COVERS TO (;f & WITH STEEL RINGS p-BOX cover must be SAS cover must be do COVERS ALL INLETS/OUTLETSTO GRADE WITH STEEL RING/COVER �0 GRADE WITH STEEL -x---Grade over D-Box - 99.OD /- I I 1 i r, UM a_a_•_a_s_a_a_a_a_a_a_a_a. pacted stone 117 S-0.01 Greater 20' NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITH 6" BELOW GRADE 3-24" OIAM. ACCESS MANHOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW r 3-24" REMOVABLE COVERS min. clearance ' _3" .T-L2_ in. inlet to Liquidle ull at 6- m n 10" . � 14' Gdo so 32 THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO WITHIN 6" OF FINISHED GRADE. INSTALL TUF-71TE GAS BAFFLES OR EQUALS f 13" INLET Y �-:3 OUTLET •• fL 6' -2- 4'-0* min. Liquid depth Y 4Lt 5 HOLE (H-20) DIST. BOX over SAS - 99.00 TOP OF SAS -1 96.50 J- V. V l V . V V% A%00- a& 15' n n n C 3 n j to rn a co I n ¢' 4 II II w TRIFOMj Effective Width ! REMOVE & REPLACE TO o 6 in.of 3/4"-1 1/2" BOTTOM OF C-1 LAYER compacted stone Bottom of Test Hole 1 Elev.= 84.00 Note: Remove soil down to el. 88.00 or C--1 Layer & replace with clean coarse sand /perc. rate less than or or equal to 2 min. in. before & after placement 12'-2" '.• g• -8- - CROSS SECTION NOT TO SCALE END --SECTION TYPICAL 2500 GALLON SEPTIC TANK/2 COMPARTMENT Design Calculations Number of Bedrooms: 2 Equivalent to 220 Gal./Day RETAIL SPACE-2000 SF 050 Gal/1000 SF = 100 Gal/Doy OFFICE SPACE-2000 SF 075 Gol/1000 SF = 150 Gal/Day Leaching Capacity Proposed: 470 Gal./Day Minimum (Min. Per Title V) Septic Tank : - 2 x470 Gol./Day = 660 USE NEW 2500 GAL Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Bottom Area: 0.74 gal/day/sq. ft. x 546 sq. ft. = 404.04 gallons/day Sidewoll Area: 0.74 gal./day/sq. ft. x 220 sq. ft. = 162.80 gallon/day Providing: = 566.84 gallons/day Use: (4) 500 H--20 CONCRETE CHAMBERS, HAVING A 2' EFFECTIVE DEPTH, (5' W x 8.5' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 4' OF WASHED STONE ON THE ENDS. PERCOLATION TEST Date of Percolation Test: AUGUST 27, 2021 Test Performed By. CARMEN E. SRA-Y ---R.S., C.S.E. I esults Witnessed By. BRUCE MURPHYN - YARMOUTH EXCAVATOR: SHAY ENVIRONMENTAL SERVICES Percolation Rate: Less Than 2 MPI ® 132"-Sieve Test Hole No. 1 DEPTH SOILS ELEV. 0 99.00 Asphalt 0"- 6" 98.50 DENSE GRAD 6"-12" 98.00 Sandy Loam 10 YR 5/6 97.00 12"-24" E6 SILT LOAM 2.5 Y 8/4 24"-132" c, 8.00 Med.-Coors Sand 2.5 Y 7/4 132"-180 e5x CGravMl84.00 Test Hole No. 2 DEPTH SOILS ELEV. 0 99.00 Asphalt 0"- 6" 98.5+0 MEN SE GRAD 6"-12" 98.00 10 YR 5/6 12"-24" Bw 97.00 SILT LOAM 2.5 Y 8/4 54"-96' C, 91.00 Sand 2.5 Y 7/4 <5x Gravel 96"-150" C2 86.50 Perc #1 Depth to Perc: 132"-Sieve Analysis Perc-Ttate= <2 MPI ,Qround-water Not Observed No Observed ESHWT ADJUSTED H2O Elev. = None SECTION A -A PROFILE VIER' OF LEACHING SYSTEM s* 1n " rea.a cvwa%" soon• INSPECTION cover must be Within 6 in. of finished grade 4 units e 8.5` = 34' 4' 34' Effective Length 4' !/.t" was"d possums SOIL ABSORPTION SYSTEM (SAS) 500 - C H-20 LEACHING UNITS / WIGGINS PRECAST Not to Scale ALL OUTLET PIPES FROM THE DISTRIBUTION BOX SHALL BE WNCRE.E COVER SET LEVEL FOR AT LEAST 2 FT. PLAN SECTION 3 - 5" OUTLET KNOCKOUTS 4' - SCH. 40 Tee- 2.00' CROSS-SECTION 5 HOLE H-20 DISTRIBUTION BOX NOT TO SCALE PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR 161 MAIN STREET CONDOMINIUMS AT 161 MAIN STREET ASSESSORS ID: YARMOUTHPORT, MA PREPARED BY: CARMEN E. SffA Y ENVIRONMENTAL SERVICES P.O. BOX 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCALE: N/A SHEET 2 1 DRAWN BY: CES DATE: DEC 22, 2021 PROJECT# 161 MAIN STREETFILENAME: 161 MAIN STREET.dwgi SHEET 2 OF 2