Loading...
HomeMy WebLinkAboutEnginer Plan - resubmittedGENERAL NOTES: 1. CONTRACTOR SHALL NOTIFY "DIG -SAFE" AS REQUIRED PRIOR TO THE START OF ANY EXCAVATION WORK. CONTRACTOR IS RESPONSIBLE FOR PROTECTING UTILITIES WITHIN THE WORK AREA DURING CONSTRUCTION. 2. THIS PLAN IS FOR SEWAGE DISPOSAL SYSTEM DESIGN PURPOSES ONLY. PROPERTY LINES PER PLAN ENTITLED "PLAN OF LAND #361 MAIN ST., YARMOUTH MA" BY OUTERMOST LAND SURVEYING INC DATED 9/31/2021. 3. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION 4. ALL CONSTRUCTION SHALL CONFORM TO THE STATE SANITARY REGULATIONS (310 CMR 15.00) AND ALL OTHER APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND REGULATIONS. 5. CONTRACTOR TO VERIFY EXISTING CONDITIONS, INCLUDING ELEVATIONS OF EXISTING BUILDING SEWER, AND REPORT AND DISCREPANCIES TO THE DESIGN ENGINEER PRIOR TO THE SETTING OF ANY SEWAGE DISPOSAL SYSTEM COMPONENTS. SEWAGE DISPOSAL SYSTEM NOTES: 1. H-20 RATED COMPONENTS SHALL BE REQUIRED IN ANY AREAS SUBJECT TO VEHICULAR LOADING AND AS REQUIRED ON T'HE PLAN. 2. THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS CONSTRUCTED AS SHOWN. ANY CHANGES OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING. 3. ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL BE 0.01 FT/FT. 4. SOIL ABSORPTION SYSTEMS MUST BE VENTED WHEN DISTRIBUTION LINES EXCEED 50 FEET IN LENGTH, WHEN LOCATED IN AREAS SUBJECT TO VEHICULAR LOADING, AND WHEN PRESSURE DOSED. 5. FINISHED GRADE SHALL BE A MAXIMUM OF 36" AND A MINIMUM OF 9" OVER THE TOP OF ALL SYSTEM COMPONENTS. 6. EXISTING SEPTIC COMPONENTS TO BE PUMPED DRY FILLED WITH CLEAN SAND AND ABANDONED. SEPTIC TANK SHALL HAVE A HOLE PUNCHED IN BOTTOM OR CRUSHED. 7. ALL SEPTIC COMPONENTS SHALL BE INSTALLED WATERTIGHT. 8. COMPONENTS TO BE PROVIDE WITH WATERTIGHT ACCESS COVERS RAISED TO WITHIN 6" OF GRADE WHERE REQUIRED. 9. PRIOR TO FINAL INSPECTION BY THE ENGINEER AND THE BOARD OF HEALTH ALL SYSTEM COMPONENTS MUST BE INSTALLED INCLUDING ALL ACCESS COVERS WITH RISERS. 10. SOIL REMOVAL: ALL TOPSOIL (A), SUBSOIL (B LAYER), AND FILL SHALL BE REMOVED FOR A DISTANCE OF 5' FROM THE SOIL ABSORPTION SYSTEM DOWN TO THE CLEAN SAND LAYER, LAYER C1 (ELEVATION VARIES SEE SOIL LOGS). AREA TO BE BACKFILLED WITH CLEAN "TITLE 5" SAND AND COMPACTED TO MINIMIZE SETTLING. CONTRACTOR TO NOTIFY TOWN AND/OR ENGINEER TO VERIFY SOIL REMOVAL AS REQUIRED. 11. PROPOSED SEWER EXIT LINE LOCATION/ELEVATION: PLUMBER TO CONFIRM AND APPROVE LOCATION AND ELEVATION OF PROPOSED SEWER LINE PRIOR TO THE SETTING OF ANY SEPTIC COMPONENTS. SCHEMATIC FLOW PROFILE: NOT TO SCALE FINISH FLOOR EL=48.3± 0 Uj LO •G O 0Of L6 4" DIA SCH 40 * , , PVC PIPE *43.00 *SEE NOTE #11 e 6. 1 42.67 RAISE COVERS TO WITHIN 6" OF FINISH GRADE WITH H-20 - COVER AND RISERS FINISH GRADE=46± DROP: Y mkL .%,,13* max. GAS BAFFLE PROPOSED 1,500 GALLON SEPTIC TANK (H-20) DEEP OBSERVATION HOLE LOGS DEEP OBSERVATION HOLE 1 EL. = 46± NO SCALE DEEP OBSERVATION HOLE 2 EL. = 45.5± DEPTH FROM SURFACE SOIL HORIZON SOIL TEXTURE SOIL COLOR MUNSELL 0" - 14" A LOAMY SAND 10 YR 3/4 14" - 34" B LOAMY SAND 10 YR 5/8 34" - 140" C1 MEDIUM/FINE 10 YR 8/6 SAND DEPTH FROM SURFACE SOIL HORIZON SOIL TEXTURE SOIL COLOR MUNSELL 0" - 67" FILL - - - - - - 67" - 130" Ct MEDIUM/FINE 10 YR 8/6 SAND DATE OF TESTING: 10/20/21 PERCOLATION RATE: LESS THAN 2 MIN/INCH IN C1 LAYER (PERC @ 65") WITNESSED BY: KEITH E. FERNANDES, PE, DIG -IT CONSTRUCTION LLC SYSTEM DESIGN CALCULATIONS: DESIGN FLOW;._ EXISTING 3 BEDROOM DWELLING AT 110 GAL. PER DAY PER BEDROOM = 330 GPD 330 GPD X 200% = 660 GALLONS - USE NEW 1500 GALLON TANK (TITLE 5 MIN.) A 25' L. X 12.83' W. X 2' D. LEACHING CHAMBER (H-20) CAN LEACH: Vt = [(25 X 12.83) + (25 X 2)2 + (12.83 X 2)2] X 0.74 GPD/SF = 349 GPD NOTE: A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN. INSTALL: ONE (1) - 1500 GALLON SEPTIC TANK (H-20) TWO (2) - 500 GALLON LEACH CHAMBERS (H-20) WITH 4' OF STONE AROUND ONE (1) - 3 OUTLET DISTRIBUTION BOX (H-20) PHILIP RENAUD, AGENT, YARMOUTH HEALTH DEPARTMENT NO GROUNDWATER ENCOUNTERED ASSESSORS' MAP 75 PARCEL 44 USE A LOADING RATE OF 0.74 GPD/SF FOR SIZING OF SOIL ABSORPTION SYSTEM. $ w 44.5 $. LEGEND Ro 6 & J 4 32 EXISTING CONTOUR 6, $ x12.34 EXISTING SPOT GRADE PLAN VIEW 4 4 & ° - "- WATER SERVICE LINE TP 44.8 J Mass. Highway Bound, Found 6M TEST HOLE / BORING LOCATION SCALE: 1" = 20' ) 1 $ ST SEPTIC TANK - d 0 ` 4.3 EXISTING VEGETATION TO BE TRIMMED/REMOVED DB DISTRIBUTION BOX 7 I 9e ( IN ORDER TO PROVIDE ACCESS SAS SOIL ABSORPTION SYSTEM lC�m 45.6 4 CONTRACTOR TO GET PERMISSION FROM HOMEOWNER x FENCE c�. $ RIOR TO TRIMMING AND/OR REMOVING ANY VEGETATION .8± J GAS LINE '45:3y .6EDGE OF CLEARING EXISTING SEPTIC COMPONENTS 18" Ceda 46.2 $ 44.0 (SEE NOTE #6) 3 5 .6 0 oncrete Bound, Found O / \ .5 $ N u 36" Decid= 45.9 2qj N Fin FIr= 48.3 Benchmark: Top of Concrete Bound ?6.4 �, S SAS Z 44.9 Elevation = 44.90 NAVD88 N46. 6.8 ST S .� � 21 46-9. 9Sept;p c 5.0, f o . e�;ir Fro / %tea �� Fin FIr= 48.3 45.4 SAS DETAIL w / 4 x 447.2(to be he wer C Zp 5 39. ���c wat � w moVed7 r SCALE: 1" = 10' / 45.9 47.1 4 9V 3 / 47.1 Fin FIr= 48.3 -- - DB c, in FIr= 47PROPOSED .3 INSPECTION STONE 46.5 PORT 52. 47.7 Fin FIr- 47.4 ��o 5 CHAMBER 00 0D 6.7 0 48.3 G/ J .6 52.1 47.2 6P 47.0 Found 6 4.8 6.8 4" Dead= 47.1 SOIL REMOVAL (SEE NOTE #10) 6.0 6'8 BUILD UP COVER 15.7± 6 55.7 1 47. RAISE COVER TO WITHIN 6" OF FINISH GRADE WITH H-20 COVER AND RISER 4"0 SCH 40 PVC PIPE 1 42.42 1 RAISE (1) COVER TO WITHIN 6" OF FINISH GRADE WITH H-20 RISER AND COVER _ H OF 7Z; 54.7 3 7 51. Land Court Bound, Found KEITH E. �, FERNANDES', 3.7 $ CIVIL NM 48725 1STEa� �'V r_ "C/CWAL Ear" FLOOR PLAN FINISH GRADE=46± FINISH GRADE=46 (MAX) (1) 4" SCH. 40 PVC TO BE PROVIDED BY OWNER f f yr INSPECTION PORT W LINES) EXITING D'BOX SHALL HAVE 35" Proposed / 18" PIECE OF SPEED LEVELERS AND SHALL REMAIN REBAR RAISE TO WITHIN LEVEL FOR 2'-0" BEFORE PITCHING (9" Min - 36" Max) 4" OF GRADE Yarmouth Health Department DOWN TO LEACHING FACILITY PIPE SHALL BE AppRp�ED PERFORATED WITHIN C u_� - 1• 4" DIA SCH 40 PVC PIPE 43.1± 2" Nam Date DROP 1 2" LAYER OF 1/8" - 1/2" STONE (OR 42.40 EFFECTIVE' 3/4" - 1-1/2" STONE DOUBLE WASHED STONE ALL 42.10 DEPTH 0 20 40 60 COMPACTED BASE DB-3 W/ 6" LAYER OF 40•1t USE (2) SHOREY PRECAST (OR EQUAL) D-BOX CRUSHED STONE ALL 500 GALLON LEACH CHAMBERS (H-20) 8•9' SCALE 1"=20' (H-20) WITH STONE AROUND (SEE SAS DETAIL). 2'± 13'± LONGEST RUN (END VIEW) LEACHING CHAMBER EL=87± BOTTOM OF TEST PIT #1 25' x 12.83' x 2.0'�_. 4' , 8.5' 8.5' , 4' 25' DIG -IT CONSTRUCTION, LLC PO BOX 268 SOUTH DENNIS, MA 02660 PHONE: 508-432-1635 www.digitconstructionlie.com cUENT: RUSTIC ELEGANCE, LLC 22B ATLANTIC AVE. S. DENNIS, MA 02660 C:\Users\kfern\Dig It Construction Dropbox\AAEngineering\Active Jobs\7004- 361 Main Street - Yarmouth \CAD\Plans\7004- SAS. dwg