Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 0 57 Lot cc.).... Zone of Contribution: In Out ----Acreage /' Sf 0 Commercial: Residential: Street: J Y !J' rn6 a r L v r x Village: Floor Plan: # Bedrooms: 171 Owner: Installer: f Address: . .S7 I., e<� Phone: Phone: Builder: Engineer:_ y e r ,Y s(),-1...; Address: _ Phone: Phone: N/A YES NO 1. Required#of copies received 4/ 2. Date of soils exam and percolation test not older than 2 years z/ 3. 4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands ,/ 7. Septic tank minimum 10 ft from foundation, deck Var.: ` 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: / 13. Uses adjustment for maximum high groundwater Var.: • 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.` y 15. System not in top or subsoil(A,B horizons)or 5' removal ,/ 16. Proposed contours are suitable d7 17. System meets slope requirements-min. 1/8", 1/"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal / 22. System adequately sized for its intended use V 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size I_. 28. Septic tank/pump chamber to be factory waterproofed v�`� 29.Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature , )/ 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee,installer signature 35. Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd v 37. Check area lots for groundwater/Label groundwater in Assessor's Map �/ Plan reviewed by: 1 o;o: