Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. 13 I Lot b O Zone of Contribution: In Out✓ Acreage Commercial: Residential: Street: Village: Floor Plan: 1/ #Bedrooms: Owner: 2 o Y CP%R0 i A.)L N Installer: _Sp c 4., - y Address: Phone: Phone: Builder: Engineer: -� �e c,JA.) Address: Phone: Phone: N/A YES NO 1. Required#of copies received v 2.Date of soils exam and percolation test not older than 2 years t/' 3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 1/ 5. Water line 10 ft from septic components Var.: 1 6. Benchmark indicated and shown-NGVD if near wetlands 4--• 7. Septic tank minimum 10 ft from foundation, deck Var.: 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab L v- - 9. Leaching minimum 100 ft from wetlands _ �� t ._...- 10. Leaching minimum 150 ft from drinking well/25 ft . . we Var.: 11.Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: `N / 13. Uses adjustment for maximum high groundwater Var.: i- 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:/' --> y '15. System not in top or subsoil(A,B horizons)or 5' removal ,/ 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/"preferred ,/ 18. System meets breakout requirements PVC liner: Wall: // 19. Specified tee sizes are proper, gas baffle on outlet tee // 20. Sewage is under 10,000 gpd for parcel t/ 21.No garbage disposal 22. System adequately sized for its intended use v 23.Minimum 6"stone or compacted below tank and dbox 4 - 24. Manhole covers within 6"of grade,pump chamber cover to grade 4/ 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes r/ 27.Pump system-2"line,weep hole,check valve, tee in dbox,pump size t/ 28. Septic tank/pump chamber to be factory waterproofed Z/ 29. Vent provided if leaching below 3 feet,under driveway/parking • 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: / • 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35.Foundation footing min.2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd ------ 37. Check area lots for groundwater/Label groundwater in Assessor's Map i/ f Plan reviewed by: y� L -