HomeMy WebLinkAbout41 Uncle Roberts plans 18GENERAL NAILING SCHEDULE JOINT DESCRIPTION NUMBER OF NUMBER OF COMMON NAILS BOX NAILS NAIL SPACING ROOF FRAMING BLOCKING TO RAFTER (TOE -NAILED) 2-8D 2-1 OD EACH END RIM BOARD TO RAFTER (END -NAILED) 2-16D 3-16D EACH END WALL FRAMING TOP PLATES AT INTERSECTIONS (FACE -NAILED) 4-16D 5-16D AT JOINTS STUD TO STUD (FACE NAILED) 2-16D 2-16D 24" O.C. HEADER TO HEADER (FACE -NAILED) 16D 16D 16" O.C. ALONG EDGES FLOOR FRAMING JOIST TO SILL, TOP PLATE OR GIRDER (TOE -NAILED) 4-8D 4-10D PER JOIST BLOCKING TO JOIST (TOE -NAILED) 2-8D 2-10D EACH END BLOCKING TO SILL OR TOP PLATE (TOE -NAILED) 3-16D 4-16D EACH BLOCK LEDGER STRIP TO BEAM OR GIRDER (FACE -NAILED) 3-16D 4-16D EACH JOIST JOIST ON LEDGER TO BEAM (TOE -NAILED) 3-8D 3-10D PER JOIST BAND JOIST TO JOIST (END -NAILED) 3-16D 4-16D PER JOIST BAND JOIST TO SILL OR TOP PLATE (TOE -NAILED) 2-16D 3-16D PER FOOT ROOF SHEATHING WOOD STRUCTURAL PANELS RAFTERS OR TRUSSES SPACED UP TO 16" O.C. 8D 10D 6" EDGE / 6" FIELD RAFTERS OR TRUSSES SPACED OVER 16" O.C. GABLE ENDWALL RAKE OR RAKE TRUSS W/O GABLE OVERHANG 8D 8D 10D 10D 4" EDGE / 4" FIELD 6" EDGE / 6" FIELD GABLE ENDWALL RAKE OR RAKETRUSS W/ STRUCTURAL OUTLOOKERS 8D 10D 6" EDGE / 6" FIELD 4" EDGE 4 FIELD GABLE ENDWALL RAKE OR RAKE TRUSS W/ LOOKOUT BLOCKS 8D 10D / CEILING SHEATHING GYPSUM WALLBOARD 5D COOLERS - 7" EDGE / 10" FIELD WALL SHEATHING WOOD STRUCTURAL PANELS STUDS SPACED UP TO 24" O.C. 8D 10D 6" EDGE / 12" FIELD 1/2" AND 25/32" FIBERBOARD PANELS 8D1 - 3" EDGE / 6" FIELD 1/2". GYPSUM WALLBOARD 5D COOLERS - 7" EDGE / 10" FIELD FLOOR SHEATHING WOOD STRUCTURAL PANELS 1" OR LESS 8D 10D 6" EDGE / 12" FIELD GREATER THAN 1" 10D 16D 6" EDGE / 6" FIELD 1 CORROSION RESISTANT 11 GAGE ROOFING NAILS AND 16 GAGE STAPLES ARE PERMITTED, CHECK IBC FOR ADDITIONAL REQUIREMENTS. NAILS- UNLESS OTHERWISE STATED, SIZES GIVEN FOR NAILS ARE COMMON WIRE SIZES, BOX AND PNEUMATIC NAILS OF EQUIVALENT DIAMETER AND EQUAL OR GREATER LENGTH TO THE SPECIFIED COMMON NAILS MAY BE SUBSTITUTED UNLESS OTHERWISE PROHIBITED. TOP PLATE SPLICE BUILDING DIMENSION OF WALL CONTAINING TOP PLATE SPLICE (FT.) SPLICE LENGTH (FT.) 12 16 20 24 1 28 1 32 1 36 1 40 1 50 1 60 70 80 NUMBER OF 16D COMMON NAILS PER EACH SIDE OF SPLICE 2 4 6 8 8 NP NP NP NP NP NP I NP NP 4 4 6 7 8 10 12 14 16 NP NP NP NP 6 4 6 7 8 10 12 14 16 20 24 NP NP 8 4 1 6 7 8 110 112 J 14 116 20 24 28 32 NP= NOT PERMITTED WALL CONNECTIONS FOR ENDWALL ASSEMBLIES WALL HEIGHT (FT) STUD SPACING UPLIFT (LB.) 8 10 1 12 14 16 18 20 PLATE -TO -STUD -.NO. OF 16D COMMON NAILS - (ENDNAILED) 12" O.0 127 2 2 2 2 2 2 2 16" O.0 169 2 2 2 2 2 2 2 24" O.0 253 2 2 2 3 3 3 4 WALL OPENINGS - HEADERS IN LOADBEARING WALLS & NON-LOADBEARING WALLS HEADER SPAN (FT.) MINIMUM HEADER SIZE REQUIREMENTS AT EACH END OF HEADER NUMBER OF FULL -HEIGHT STUDS UPLIFT (LB.) LATERAL (LB.) HEADERS IN LOADBEARING WALLS 2 2-2X4 1 277 132 3 2-2X4 2 416 198 4 2-2X4 2 554 264 5 2-2X4 3 693 330 6 2-2X6 3 831 396 7 2-2X8 3 970 462 8 2-2X12 3 1,108 528 9 3-2X10 3 1,247 594 10 3-2X12 4 1,385 660 11 4-2X10 4 1,524 726 HEADERS IN NON-LOADBEARING WALLS AND WINDOW SILL PLATESI 2 1-2X4 (FLAT) 1 60 132 3 1-2X4 (FLAT) 2 90 198 4 1-2X4 (FLAT) 2 120 264 5 1-2X4 (FLAT) 3 150 330 6 1-2X6(FLAT) 3 180 396 7 1-2X6 (FLAT) 3 210 462 8 1-2X6 (FLAT) 3 240 528 9 2-2X6 (FLAT) 3 270 594 10 2-2X6 (FLAT) 4 300 660 11 2-2X6 (FLAT) 4 330 726 12 2-2X6 (FLAT) 5 360 792 1 FOR NON -LOADING BEARING WALLS AND WINDOW SILL PLATES, 2-2X4 (FLAT) CAN BE SUBSTITUTED FOR 1-2X6 (FLAT) Pony wall height, 12' Max. total wall height 10, Max. height PORTAL FRAMING DETAIL Outside Elevation Extent of header (two braced wall segments) Extent of header (one braced wall segment) O 0 0 0 0 0 ° ° 0 ° 0 0 ° ° ° ° ° ° ° ° ° ° ° ° ° Min. 3" x 11-1/4" net header ° 0 0 O Header shall be Top plate >J) fastened to the continuity is Cl)00 .R °J king stud with required per °° W/ 6-16D sinker nails R602.3.2 0o a oo Minimum 1000 lb header -to- 0 ° ° ° jack -stud strap shall be centered .0 ° at bottom of header and installed ° on backside as shown on ° QO ° 0. .0 ° 0 side elevation 0. 2' to 18' (finished width) 00 °° 0 °° 0 O 3 lo Braced wall line with Min. number of continuous sheathing ° ° ° ° studs shown No. of jack studs 00 °° °° ° Full -length per table R502.5(1 &2) i king stud \_ 2 Anchor bolts per R403.1.6 required \- Foundation per code Side Elevation Min. 1000 Ib tension strap,. Strap shall be centered at bottom of header. Sheathing filler if needed 16d sinker nails in 2 rows @3"o.C. Wood Structural panel must be continuous from top of wall to bottom of wall, or from top of wall to permitted splice area Full-length king studs 3/8" min. thickness wood structural panel sheathing Not to scale 1O Fasten sheathing to header with 8d common nails in 3-in. grid pattern as shown and 3 in. o.c. in all framing (studs and sills) typ. 2O For a panel splice (if needed), panel edges shall occur over and be nailed to common blocking and occur within the middle 24 in. of wall height. One row of 3 in. o.c. nailing is required at each panel edge. 3O Min. length based on 6:1 height -to -width ratio. For example: 16 in. min. for 8 ft. height. AT FIRST INTERIOR BAY, PROVIDE 2X BLOCKING AT GUARD POSTS; TOE NAIL WITH 10D COMMON NAILS TOP & BOTTOM, EACH SIDE - OUTSIDE JOIST SEE FIGURE 24 FOR GUARD POST ATTACHMENT REQUIREMENTS GUARD POST CROSS BLOCKED & THROUGH BOLTED GUARD POST TO JOIST DETAIL General Notes: 1. The structural drawings shall be used in conjunction with the architectural, civil, mechanical, plumbing, and electrical drawings and the specifications. The contractor shall verify the requirements of other trades as to items to be placed o r set in the structural work. 2. The structure has been designed in accordance with the provisions of the International Residential Code (IRC 20 15) with Massachusetts State Building Code Amendments (9th Edition). 3. The contractor shall provide temporary shoring and bracing required to erect and hold new structures in proper alignment until permanent supports and lateral bracing are in place. 4. Where construction occurs within or adjacent to existing construction, the contractor shall field measure the existing building dimensions and components and coordinate construction details with the actual dimensions. Design Loads: 1. The structure was designed for the following loads: Roof Snow Loads Ground Snow Load (Pg)=30 psf Sleeping Areas 30 psf All Other Areas 40 psf Wind Loads Ultimate Wind Speed (V) 140 mph (3 second gust) Exposure C Soil Conditions and Structural Fill : 1. All footings shall be carried to the depths shown and deeper, if required, and shall rest on undisturbed soil having a safe bearing pressure of 2000 psf. 2. No footing shall be placed on frozen soil or in standing water. 3. Structural fill shall be well graded bank run, screened or crushed gravel, and shall be placed in 8" maximum lifts and compacted to 95% of maximum dry density as determined by ASTM D1557. Provide a minimum of 6" (or greater if required by the geotechnical engineer) well compacted, clean, coarse sand and gravel under all slabs on grade after the top soil has been removed. Concrete : 1. All concrete shall at tain a minimum compressive stre ngth of 3000 psi at 28 days except the garage slab w hich stall attain a minimum compressive strength of 3500 psi at 28 days. 2. All reinforcing steel shall be deformed bars conforming to ASTM A615 Grade 60. 3. The following minimum cover shall be provided for re inforcement: Concrete against the earth 3" Formed concrete expose d to earth or weather #5 or smaller 1 %" #6 or larger 2" Concrete not exposed to earth or weather slabs or walls %11 beams and columns 1 %" 4. All concrete work and detailing shall comply with t he latest specifications and recommendations of the ACI. All cont inuous reinforcing bars shall be lapped 36 bar diameters at splices and at corners unless otherwise noted. Terminate continuous bars at non -continuous ends with standard hooks. Wood Framing: 1. Lumber shall be Spruce -Pine-Fir #1/#2 or better with the followin g minimum properties: Allowable Bending Stress Fb=875 psi Allowable Shear Stress Fv=70 psi Compressive Stress Fc=1150 psi Modulus of Elasticity E=1,400,000 psi 2. Pressure treated lumber shall be used where indicated on plans, in all exterior applications, and in applications where the lumber is in contact with ground. Pressure treated lumber shall be Southern Yellow Pine #1 and shall be treated with Alkaline Copper Quat (ACQ) or Copper Azole (CBA) preservative. 3. Framing connectors and fasteners for use with pressure treated lumber shall be stainless steel. Alternatively, batch/post hot -dipped galvanized fasteners (ASTM A153) and framing connectors (ASTM A123) may be used. 4. Plywood wall sheathing sha II be 15/32" or %" thick APA rated sheathing, Structura 11, C-D exterior glued, 24/0 spa n rating. Face grain shall be placed perpendicular to supports and joints shall be staggered. 5. Plywood shear wall sheathing shall be 15/32" or Y thick APA rated sheathing, C-D exposure 1, 24/0 span rating. Strength axis sha II be perpendicular to supports. 6. Install horizontal blocking in exterior stud walls. Blocking shall align with horizontal joints in exterior plywood sheathing 7. Fasten sheathing to studs and hor izontal blocking with 8d nails spaced at 6" on center around th a perimeter of individual sheets and at 12" on center elsewhere. 8. Plywood roof sheathing shall be 19/32 or 5/8" thick APA rated sheathing, C -D exposure 1, 32/16 s pan rating. Long dimension shall be perpendicular to supports and joints shall be staggered. 9. Fasten roof sheathing to supporting members with 8d nails spaced at 4" on center around the perimeter of individual whets and at 12" on center elsewhere. 10. Plywood subfloor shall be 23/32" or 3/4" thick APA rated Sturd-I-Floor, C (plugged)-D exposure 1, 16" on center rating. Provide tongue and groove joints or provide blocking at all unsupported edges. 11. Plywood subfloor shall be glued to the supporting members with a mi nimum of 1 " diameter continuous bead of construction adhesive conforming to the requirements of ASTM D3498 (AFG-0a)/ Use two beads where panel edges abut. 12. Fasten plywood sub floor to each supporting joist with 10d (3" long) deformed shank nails spaced at 6" on center along the panel edges and at 12" on center elsewhere. 13. Provide solid blocking at all floor levels between upper and to wer posts or between upper posts and foundation walls. 14. Provide solid blocking (16" on center) or double all joists under each partition where the joists span pa rallel to the walls. 15. Use fully nailed metal connectors (TECO, S impson, or equal) joist or beam h angers when framing into other joists or beams. 16. Header Sizes (unless noted on plans): Up to 4'-0" (3) 2x8s for a 2x6 wall and (2 ) 2x8s for a 2x4 wall Up to 6-6" (3) 2x10s for a 2x6 wall and (2) 2x10s for a 2x4 wall 17. All Parallams or Microllams shall be ins talled in accordance with the manufacturer's specifications and recommendations. The minimum allowable bending stress (Fb) shall be 2600 psi, the minimum allowable comp ressive stress (Fc) shall be 2510 psi, and the modulus of elasticity (E) shall be 1,900, 000 psi. 18. Built-up members using conventional lumber shall be fully spiked together with 2 -10d nails (top and bottom) at 8" on ce nter or with (2) %"x 3-1/2" long lag bolts (top and bottom) at 16" on center. Structural Steel 1. Structural steel has been designed in a ccordance with the American In stitute of Steel Construction (AISC) "Steel Construction Manual - Allowable Stress Design (15 th Edition). 2. Structural steel fabricatio n and erection shall comp ly with the provisions of AISC's "Code of Standard Practice for Steel Buildings and Bridges (current edition). 3. Structural steel shall confo rm to the following: W sections ASTM A992, Fy=50 ksi HSS sections ASTM A500, Grade B, Fy=46 ksi Other structural steel shapes, plates, and bars ASTM A36, Fy=36 ksi Anchor bolts ASTM F1554 Grade 36, 55, or 105 4. All field welding sha 11 be performed by a n AWS certified welder qualified for the welds sh own. 2X6 RAIL CAP 4X4 PT POST W FIBERGLASS SLEEK PROVIDE ADJUSTMI TURNBUCKLES @ CORNE CABLES RUN THRO INTERMEDIATE POD (2) 1 /2" DIAM. THRU-BOL' OPENINGS SHALL NOT THE PASSAGE OF H 1+ DIAMETER SPHERE mom TYPICAL GUARD RAIL DETAIL PERMIT SET 12*01*2022 r c h �LT%c ts architects interior designers builders 299 WHITE'S PATH SOUTH YARMOUTH, MASSACHUSETTS, 02664 tel (508) 362 - 8883 (508) 760 - 2800 fax (508) 760 - 5800 WWW.ERTARCHITECTS.COM RESIDENCE FOR: PETER 8c ROBERTA FAIRBANKS 41 UNCLE,J ROBERT ROAD WEST YARMMOUTH, PROJECT # 210422 2022 ERT ARCHITECTS, INC. THE DRAWINGS AND ALL OF THE IDEAS, ARRANGEMENTS, DESIGNS, AND PLANS INDICATED THEREON OR REPRESENTED THEREBY, ARE OWNED BY AND REMAIN THE PROPERTY OF ERT ARCHITECTS, INC. NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE, EXCEPT WITH SPECIFIC WRITTEN PERMISSION OF THE FIRM ERT ARCHITECTS, INC. THESE PLANS ARE NOT TO BE USED FOR PERMITTING OR CONSTRUCTION PURPOSES UNLESS STAMPED & SIGNED WITH AN ORIGINAL ARCHITECT'S STAMP AND SIGNATURE & MARKED AS "PERMIT SET" OR "CONSTRUCTION SET". REGISTRATIO REVISIONS DATE: REVISIONS: ISSUED FOR: PERMITTING DATE: 12.01.2022 (i) & PROJECT TRUE SCALE: 1 /4"=V-0 0 1 2 4 8 UNLESS OTHERWISE NOTED. SHEET NO. A * 1 8 TOTAL NUMBER OF SHEETS IN SET: 38 THIS SHEET INVALID UNLESS ACCOMPANIED BY A COMPLETE SET OF WORKING DRAWINGS