HomeMy WebLinkAbout99 Route 28 plans 1OWNER:
HAMPTON INNm iAfEST
YARMOUTH
99 MA-28, WEST YARMOUTH, MA 02673
PERMIT SET
JAN UARY 24, 2023
GENERAL NOTES
A: GENERAL
1. THE CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE SITE
PRIOR TO BID SUBMITTAL TO BECOME FAMILIAR WITH
CONDITIONS AT THE SITE AFFECTING PERFORMANCE OF THE
WORK.
2. THE WORK SHALL COMPLY WITH ALL GOVERNING STATE AND
LOCAL CODES. ACCESSIBLE SPACES AND WORK SHALL COMPLY
WITH ALL APPLICABLE ACCESSIBILITY CODES
3. UNLESS OTHERWISE AGREED TO IN WRITING WITH THE OWNER,
THE CONTRACTOR IS RESPONSIBLE FOR SECURING ALL PERMITS
(BUILDING, OCCUPANCY, ETC.) AND FEES FOR SAME, AS REQUIRED
BY STATE AND LOCAL RULES AND REGULATIONS.
4. DAMAGES TO THE BUILDING OR PROPERTY DUE TO CONTRACT
OPERATIONS MUST BE REPORTED IMMEDIATELY TO THE BUILDING
OWNER.
5. THE OWNER RESERVES THE RIGHT TO PERFORM ADDITIONAL
WORK THAT IS NOT PART OF THIS CONTRACT WITH HIS OWN
FORCES, UNDER SEPARATE CONTRACTS AND/OR WITH OTHER
CONTRACTORS OR VENDORS. THE CONTRACTOR SHALL
COOPERATE WITH THE OWNER AND OTHER CONTRACTORS AND
COORDINATE HIS WORK WITH THE OWNER SO THAT WORK BY
OTHERS CAN BE INCORPORATED IN A TIMELY MANNER,
6. THE CONTRACTOR SHALL REPLACE OR REMEDY FAULTY, IMPROPER
OR INFERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR
WITHIN ONE (1) YEAR OR AS OTHERWISE SPECIFIED FOR A
SPECIFIC COMPONENT AFTER COMPLETION AND ACCEPTANCE OF
THE WORK. SUCH WORK IS TO BE COMPLETED AT NO COST TO THE
OWNER,
7. FURNISH AND INSTALL MATERIALS IN STRICT ACCORDANCE WITH
THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
RECOMMENDATIONS. MATERIALS AND METHODS OF INSTALLATION
TO CONFORM WITH THE APPROPRIATE NATIONAL TRADE
HANDBOOKS; I.E. ARCHITECTURAL WOODWORK INSTITUTE'S
QUALITY STANDARDS, UNITED STATES GYPSUM, GYPSUM
CONSTRUCTION HANDBOOK, ETC.
B: COORDINATION
1. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE
WORK, CONSTRUCTION SEQUENCING, SUBCONTRACTORS, AND
INSTALLED LOCATION AND INTERFACE OF THE WORK,
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF
SYSTEMS AND EQUIPMENT WITH STRUCTURE, ARCHITECTURE,
CEILING HEIGHTS, AND OTHER WORK.
3. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT
DOCUMENTS ARE NOT INTENDED. THE CONTRACT DOCUMENTS ARE
COMPLEMENTARY, IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO COMPLY WITH AND COORDINATE ALL CONTRACT DOCUMENTS
BEFORE INSTALLATION OF THE WORK. THE CONTRACTOR SHALL
CLARIFY DISCREPANCIES WITH THE ARCHITECT PRIOR TO
COMMENCING THE WORK IN QUESTION.
4. MATTERS WITHIN THE SPECIFICATIONS WHICH MAY HAVE BEEN
OMITTED IN THE DRAWINGS OR VICE VERSA SHALL BE
CONSTRUED AS THOUGH CONTAINED IN BOTH.
5. SHOULD THE SPECIFICATIONS AND THE DRAWINGS DISAGREE
WITH THEMSELVES OR WITH EACH OTHER, PROVIDE THE BETTER
QUALITY OR GREATER QUANTITY OF WORK, AS DETERMINED BY
THE ARCHITECT, UNLESS OTHERWISE DIRECTED BY APPROVED
CHANGE ORDER.
6. ALTERATIONS/DEVIATION FROM THE CONTRACT DOCUMENTS MUST
BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND WRITTEN
APPROVAL PRIOR TO PROCEEDING WITH THE WORK.
7. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE ALL
EXISTING UTILITIES, WHETHER SHOWN IN THE CONTRACT
DOCUMENTS OR NOT, AND TO PROTECT THE UTILITIES FROM
DAMAGE. REPAIR OR REPLACE UTILITIES OR OTHER PROPERTY
DAMAGED BY OPERATIONS IN CONJUNCTION WITH PERFORMANCE
OF THE WORK AT THE EXPENSE OF THE CONTRACTOR.
B: COORDINATION (CONT.)
8. PROVIDE BACK -BLOCKING FOR SUPPORT AND ATTACHMENT OF
MOUNTED ITEMS INCLUDING BUT NOT LIMITED TO ARCHITECTURAL
WOODWORK, WALL AND/OR CEILING MOUNTED FINISHES,
EQUIPMENT AND ACCESSORIES, GRAB BARS, CABINETRY,
FIXTURES, SIGNAGE, ETC. COORDINATE LOCATIONS WITH
INTERIOR DESIGNER OR OWNER.
9. PROVIDE ROUGH -INS AND WIRING FOR DATA AND PHONE OUTLETS
WHERE REQUIRED BY OWNER. OWNER'S VENDOR SHALL PROVIDE
TERMINAL DEVICES, UNLESS REQUIRED OTHERWISE.
C: MEASUREMENTS & DIMENSIONS
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT THE
WORK AND SHALL INFORM THE ARCHITECT OF DISCREPANCIES
AFFECTING PROPER COMPLETION OF THE WORK.
2. DO NOT SCALE DRAWINGS TO DETERMINE DIMENSIONS. TAKE
WORKING DIMENSIONS FROM THE FIGURED DIMENSIONS, OR BY
ACTUAL MEASUREMENTS TAKEN IN THE FIELD. DEVIATION FROM
THE DOCUMENTS AND THE DIMENSIONS GIVEN IN THE DRAWINGS
MUST BE APPROVED BY THE ARCHITECT IN WRITING PRIOR TO
COMPLETION OF THE WORK IN QUESTION.
D: MATERIAL REQUIREMENTS
1. WOOD IN CONTACT WITH CONCRETE OR STEEL TO BE PRESSURE
TREATED.
2. COMBUSTIBLE MATERIALS ARE NOT ALLOWED IN CONCEALED
SPACES AS DETERMINED BY CODE.
3. STRUCTURE SHALL BE RATED AS NOTED ON CODE DRAWINGS.
MAINTAIN RATINGS OF FIRE -RATED ASSEMBLIES.
4. PAINTING, VARNISHING OR THE USE OF OTHER NOXIOUS
SUBSTANCES MUST BE ISOLATED FROM ADJOINING SPACES,
5. PROVIDE ATTIC STOCK FOR MATERIALS. COORDINATE QUANTITIES
AND SCHEDULE WITH THE OWNER.
E: DEFINITIONS AND METHODOLOGIES
1. DIMENSIONS, ANNOTATIONS, NOTES, FINISHES, FIXTURES SHOWN
ON TYPICAL FLOOR PLANS, SECTIONS OR DETAILS SHALL APPLY TO
SIMILAR, SYMMETRICAL OR OPPOSITE PLANS, SECTIONS OR
DETAILS.
2. TYPICAL, OR "TYP" MEANS THAT THE CONDITION IS
REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT,
UNLESS REQUIRED OTHERWISE.
ACOUST ACOUSTICAL
ACC
ACCESSIBLE
ACS
ARCHITECTURAL CAST STONE
ACT
ACOUSTIC CEILING TILE
ADJ
ADJUSTABLE
AFF/A.F.F.
ABOVE FINISHED FLOOR
ALUM
ALUMINUM
ANOD
ANODIZED
ARCH
ARCHITECT (URAL)
AUTO
AUTOMATIC
BD
BOARD
BLDG
BUILDING
BLKG
BLOCKING
CFCI
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CJ
CONTROL JOINT
CL
CENTER LINE
CLG
CEILING
CLO
CLOSET
CLR
CLEARANCE)
CMU
CONCRETE MASONRY UNIT
COL
COLUMN
CONC
CONCRETE
CONST
CONSTRUCTION
CONT
CONTINUE/CONTINUOUS
CPT
CARPET
CT
CERAMIC TILE
CTR
CENTER
DBL
DOUBLE
DIA
DIAMETER
DIM
DIMENSION
DS
DOWN SPOUT
DTL
DETAIL
DWG(S)
DRAWINGS)
E
EAST
EA
EACH
EJ
EXPANSION JOINT
ELEC
ELECTRIC(AL)
ELEV
ELEVATION
ELVT
ELEVATOR
EQ
EQUAL
EQUIP
EQUIPMENT
EXT
EXTERIOR OR EXTENDED
EXG
EXISTING
FD
FLOOR DRAIN, REF: PLUMBING FOR SIZE AND TYPE
FE
FIRE EXTINGUISHER
FEC
FIRE EXTINGUISHER CABINET
FIN
FINISH
FFE
FURNITURE, FIXTURE& EQUIPMENT
FT
FOOT
FIR
FIRE RATED
FRT
FIRE RESISTANT TREATED WOOD
FRP
FIBERGLASS REINFORCED PANEL
GA
GAUGE
GLAV
GALVANIZED
GC
GENERAL CONTRACTOR
GL
GLASS/GLAZING
GU
GUEST
GWB
GYPSUM WALL BOARD
GYP
GYPSUM
HB
HOSE BIB
HC
HOLLOW CORE
HDWR
HARDWARE
HH
HEAD HEIGHT
HM
HOLLOW METAL
HR
HOUR
HT
HEIGHT
HVAC
HEAT/VENT/AIR CONDITION
ID
INSIDE DIAMETER
INCL
INCLUDE(D)
INSUL
INSULATION
INT
INTERIOR
JT
JOINT
KID
KNOCK DOWN
KP
KICK PLATE
LAM
LAMINATE
LAV
LAVATORY
LAV
LAVATORY
LH
LEFT HAND
LHR
LEFT HAND REVERSE
MAS
MASONRY
MAT
MATERIAL
SYMBOLS LEGEND
DARLING HOTELS
940 Fall River Ave
Seekonk, Massachusetts 02771
508-336-7300
info@darlinghotels.com
ARCHITECTURE AND INTERIORS:
DS
ARCHITECTURE &INTERIORS
2 CHARLES STREET 1405 RHODE ISLAND AVENUE NW
SUITE Al WASHINGTON, DC 20005
PROVIDENCE, RI 02904
+ 1.401.680.6699 + 1.202.660.0555
www.z-ds.com www.z-ds.com
INDEX OF DRAWINGS
MAX MAXIMUM
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
MANF MANUFACTURER
VIEW REFERENCES:
SHEET
NUMBER
SHEET NAME
SUBMISSION
01/24/2023
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
1 VI@W Name PLAN/ELEVATION/DETAIL
1'-0" TITLE TAG
GO.01
GENERAL INFORMATION
X
MTL M ETAL
N NORTH
NN/A NOT APPLICABLE
IDD1.01
DEMO FLOOR, RCP AND IMAGES
X
IDD1.02
DEMO IMAGES
X
NIC IC NOT IN CONTRACT
1 CALLOUT REFERENCE
NOM NOMINAL
A101
NTS NOT TO SCALE
ID1.01
FLOOR AND KEY PLANS
X
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
1
ID1.02
�FFE
FINISH PLAN
X
ID1.03
PLAN
X
OFOI OWNER FURNISHED OWNER INSTALLED
OPG OPENING
OH OPPOSITE HAND
1 A101 1 INTERIOR/EXTERIOR
ELEVATION REFERENCE TAG
ID2.01
REFLECTED CEILING PLAN
X
OPP OPPOSITE
PART PARTITION
PNT/PTD PAINT
1
ID3.01
INTERIOR ELEVATIONS
X
ID4.01
TREATS ENLARGED PLANS & DETAILS
X
PL PLATE
PLAM PLASTIC LAMINATE
PLUM- PLUMB(ING)
1 1 BUILDING SECTION TAG
ID4.02
TREATS DETAILS
X
ID4.03
PANTRY DETAILS
X
PLY/PLYWD PLYWOOD
PR PAIR
PSI POUNDS/SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
A101 A1o1
1 WALL SECTION TAG
ID4.04
MILLWORK FRONT DESK,
X
ID4.05
NOOK & MIXED MEDIA WALL
X
ID4.06
BEER TAP MILLWORK DETAILS
X
RAID RADIUS
A101
RD ROOF DRAIN
REF REFER
REFR REFRIGERATOR
REINF REINFORCE
1 DETAIL REFERENCE
REQ/REQ'D REQUIRED
A101
RH RIGHT HAND
RHR RIGHT HAND REVERSE
ELEMENT TAGS:
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
R&S ROD & SHELF
S SOUTH
Room name
ROOM NAME/NO.lxl CURTAIN WALL
1O1 PANEL TAG
SCW SOLID CORE WOOD
SCHED SCHEDULE
SECT SECTION
SHT SHEET
1A 10DOOR TAG MWXX CASEWORK TAG
SIMI SIMILAR
SPEC::: SPECIFICATION
SQ SQUARE
X' X" CEILING 0 FINISH/MATL
HEIGHT TAG TAG
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STO STORAGE
STRUC, S- STRUCTURAL
FURNITURE,
WINDOW / FIXTURE, &
O CURTAIN -WALL- EQUIPMENT
TAG TAG
SUSP SUSPENDED
SYM SYM M ETRICAL
i3EVISIONS:
SYS SYSTEM
TELE TELEPHONE
TEMP TEMPERED
T&G TONGUE & GROOVE
TC TOP OF CURB
TLT TOILET
TYPE PREFIXES: A 0 1
A = ADDENDUM
B = BULLETIN
R = REVISION TYPE NUMBER
TP TOP OF PAVEMENT
TV TELEVISION
TYP TYPICAL
_,
UN'0/UON UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VIFfV.I.F. VERIFY IN FIELD
VWC VINYL WALL COVERING
W WEST
W/ WITH
CODE COMPLI-
®MfNISSIOtVS DO NOT RELIEVE C MPLI-
" ,.�^ H� t�e�e� r � E�8 "
"� � ` `� UILT
�� J
WC WATER CLOSET
WD WOOD
WM WIRE MOLD BASE, REF: ELECT.
W/O WITHOUT
WRB WATER RESISTANT
WTR WATER
WWF WELDED WIRE FABRIC
/3�D- z3 - vo 3 1- a.
A[ /1 T /� A P- A T I•o A /•% A _ A A_ AA A A A
LV I k.,MCM CU: J./G"t/GVGJ .L.L.-t7..LV MI-1