HomeMy WebLinkAbout99 Route 28 plans 701 - FLOOR 1 RCP 1 /4" = 1'-011 REFLECTED CEILING PLAN NOTES: REFLECTED CEILING LEGEND: 1. CODE REQUIRES 1-HR SEPARATION BETWEEN ALL FLOORS. IF 1-LAYER OF x' - x" AFF CEILING HEIGHT 6" TYPE-X GWB DOES NOT EXIST UNDER FLOOR STRUCTURE, CONTRACTOR IS TAG RECESSED REQUIRED TO INSTALL 1-LAYER OF TYPE-X GWB DIRECTLY TO THE EXISTING LED CAN FLOOR STRUCTURE ABOVE IN ADDITION TO THE CEILINGS INDICATED WALL SCONCE SURFACE O BELOW. FIXTURE 2. ALL CEILING HEIGHTS ARE MEASURED FROM ABOVE FINISHED FLOOR (AFF), UNLESS OTHERWISE NOTED. WALL MOUNTED ® EMERGENCY 3. ALL GWB CEILINGS ARE TO BE TAPED, PRIMED, AND PAINTED. VANITY FIXTURE EXIT SIGNAGE 4. REFER TO ELECTRICAL DRAWINGS FORSPECIFICATIONS FOR ALL LIGHTING 5. FIXTURES. MATCH LIGHTING TRIMS TO ADJACENT PAINT, TYP EMERGENCY LIGHT (cD COMBO SMOKE 6. MEP / FP WORK TO BE DESIGN / BUILD. FINAL LOCATIONS OF EXIT SIGNAGE, & DETECTOR SMOKE DETECTORS, DIFFUSERS, SWITCHES, OUTLETS, ETC. TO BE COORDINATED & APPROVED BY ARCHITECT PRIOR TO COMPLETION. NEW GWB CEILING FZ1 FAN / LIGHT 7. ALL DIMENSIONS OF FIXTURES, DEVICES, ETC. ARE TO CENTERLINE OF FIXTURE U.O.N. WHERE ITEMS ARE IN LINE, AS INDICATED BY DASHED LINES, CENTERLINEOF ITEMS OR GROUP OF ITEMS TO ALIGN, U.O.N. NOTIFY c ARCHITECT OF ANY CONFLICTS. SINGLE SWITCH 8. PROVIDE FIRE RETARDANT WOOD BLOCKING ABOVE CEILING AS REQUIRED FOR SPECIALTY CONSTRUCTION ITEMS, I.E. PENDANTS, CEILING MOUNTED DEVICES, ETC. D SWITCH W/ 9. ALL DIFFUSERS & DEVICES IN CEILING TO BE PAINTED TO MATCH CEILING COLOR. REVIEW W/ ARCHITECT PRIOR TO COMPLETION. LU DIMMER 10. CONFIRM MOUNTING HEIGHTS OF PENDANTS & SCONCES W/ ARCHITECT 53 PRIOR TO COMPLETION. 3 WAY SWITCH 11. CEILING HEIGHTS ARE +/- GWB TO BE DIRECTLY ATTACHED TO BOTTOM OF EXISTING STRAPPING BELOW JOISTS, PROVIDE NEW STRAPPING AS REQ'D. 12. PROVIDE UL RATED CAN LIGHTS AS THEY ARE LOCATED IN RATED CEILING AND ADJACENT TO INSULATION, TYP. 13. REFER TO POWER AND SWITCHING PLANS FOR MORE INFO 14. ALL LIGHTING TO BE ON ISOLATED DIMMERS UNLESS OTHERWISE NOTED 15, EXISTING CEILING GRID TO REMAIN UNLESS OTHERWISE DAMAGED. CLIENT ARCHITECT DS ARCHITECTURE & INTERIORS 2 CHARLES STREET, SUITE Al PROVIDENCE, RI 02904 + 1.401.680.6699 1405 RHODE ISLAND AVENUE NW WASHINGTON, DC 20005 +1.202.660.0555 STAMP CONSULTANT PROJECT NAME HAMPTON INN - WEST YARM O UTH 99 MA-28, WEST YARMOUTH, MA 02673 PROJECT NO. 21145 THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS. THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT. REVISIONS NO. I DESCRIPTION DATE PERMIT SET ISSUED DATE:JANUARY 24, 2023 SHEET TITLE REFLECTED CEILING PLAN rl DRAWING NO.