HomeMy WebLinkAboutBLDE-23-002262 or Commonwealth of Official Use Only
• Massachusetts tilt
Permit No. BLDE-23-002262
BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/27/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 75 HEMEON DR
Owner or Tenant FARIAS-CARVALHO MARIA D TR Telephone No.
Owner's Address THE 75 HEMEON DR RLTY TRUST, 75 HEMEON DR,WEST YARMOUTH, MA 02673
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system (23 Panels 8.395 KW)(NO ESS)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alertine Devices
No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE:$150.00
(covi crIvq-i\s
/z,12¢/2Z 0 iC
/� ,; _.� ' - II
Official Use Only
il CComnwnaealth o/ ad 1t1
=s �CJif
e urlmenl o� rile�rv' OCT 2 6 '0j��T(L No ��/�
Will Occup c and Fee Checked
--.. / BOARD OF FIRE PREVENTION RiEG LA.TION -�,e-� II (leave blank
t.,UILDING D P,
APPLICATION FOR PERMIT Te _'—'-- . - ' CTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 10/24/2022
City or Town of: To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number)75 HEMEON DR
Owner or Tenant Maria Farias Telephone No. (508)360-1464
Owner's Address 75 HEMEON DR Yarmouth MA 02673
Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters
New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of a rooftop mounted photovoltaic solar energy system consisting of 23 solar panels producing 8.395 KW DC with No ESS
Completion of the following table may be waived by the Inspector of Wires.
.oTotal
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- D No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALAR\IS No.of Zones
of
No.of Switches No.of Gas Burners No. Initiatinggon Deten and
In Devices
No.of Ran es No.of Air Cond. Total No.of Alerting Devices
g Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
Municipal 1-1 No.of Dishwashers Space/Area Heating KW Loral❑ Connection Otla`"
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water Kam, No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
g No.of Devices or Equivalent
OTHER:Roof Mounted Solar
h additional detail ifdesired,or as required by the Inspector ofWires.
Attac add a e
9 P
Estimated Value of Electrical Work: $11,459.00 (When required by municipal policy.)
Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of pedury,that the information on this application is true and complete.
FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 4316 Al
Licensee: Nathan Ashe Signature 714
LIC.NO.:21136 A
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:978 594-3519
Address: 695 Myles Standish Blvd.Taunton, MA 02780 Alt.Tel.No.:978793-7881
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
?L.t4 &rtArn POI-Willi qetazio e aS-i-r\1a P.er-vo i-rs E svnrull . C2v4
; Lf61•
i h
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:8395W DC.6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBCIIEBC), M SOLAR MODULES PV-1.0 COVER SHEET
•MODULES:(23)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION ® SERVICE ENTRANCE
LTD:ERTERSPH)65M I•PHOTOVOLTAIC
, , ��= PV-3.0 SITE
LAYOPU N
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020.
•RACKIN•USSN MP MAIN PANEL =WM PV-4.0 ELECTRICAL
•RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020.
SEE DETAIL SNR-DC-00436 SNR MOUNT
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
•MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
nj CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LA ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER CJ FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. , PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) ^
cJ SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC
n DC DISCONNECT(S) , FIRE SETBACKS
•11.43 AMPS MODULE SHORT CIRCUIT CURRENT. r11
•17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX .',;•1 HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(BX2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE I— INTERIOR EQUIPMENT -PL- PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED
SCALE NTS
A AMPERE sunrun
AC ALTERNATING CURRENT
AFC! ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION
DC DIRECT CURRENT #180120
(E) EXISTING s MIES ST•r.n91 MVO.uwnw.w.027ro7.
ESS ENERGY STORAGE SYSTEM 1.0t.
.0t 0
EXT EXTERIOR
INT INTERIOR CUSTOMER RESIDENCE:
MAG MAGNETIC MARIA FARIAS
MSP MAIN SERVICE PANEL 75 HEMEON DR,YARMOUTH,
(N) NEW MA,02673
NTS NOT TO SCALE
OC ON CENTER TEL.(508)360-1464
r PRE-FABRICATED
SF-FAB POUNDS PER SQUARE FOOT APN:YARM-000038-000102
'75
HeniC'..
West Yarmouth,MA PROJECT NUMBER:
PV PHOTOVOLTAIC
RED RAPID SHUTDOWN DEVICE 223R-075FARI
TL TRANSFORMERLESS DESIGNER: (415)5808920 ex3
TYP TYPICAL
V VOLTS MD ALAM
W WATTS SHEET
REV NAME - DATE COMMENTS COVER SHEET
REV:A 10/22/2022
PAGE PV-1.0
Ll „Or) ...zz ::„,..z..„
ARRAY TRUE MAG PV AREA
SITE PLAN-SCALE=3/64"=1'-0" PITCH AZIM AZIM (SOFT)
/� AR-01 30° 124° 138° 196.1
,'(�I� AR-02 30° 124° 138° 156.9
i''''''..s.'
AR-03 30° 304° 318° 98
q
d' \
't (N)ARRAY AR-02
(E)GATE
C
q
(N)ARRAY AR-03--
4.' 44, A;i ..........„.;
..•,...:,,...:..;,-.. :.... .7
(E)RESIDENCE ,,, s
�O
(E)FENCE41I �`r
z sunrun
ilit
(N)ARRAY AR-01
M
q , .
'''''----,.. ,
/ #180120
m0.60 ,wrrw.w.onam1
0
q
Q, CUSTOMER RESIDENCE:
MARIA FARIAS
75 HEMEON DR,YARMOUTH,
rMP q MA,02673
®�®� \ TEL(5 -1464
APN:YARM-000038-000102
a. PROJECTECT N NUMBER:
223
q DESIGNER:
DESIGNER: (415)5808920 ex
MD ALAM
SHEET
SITE PLAN
REV.A 10/22/2022
PAGE PV-2.O
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
Name T
V re Detail OC Spacing Overhang OC Spacing Overhang Configuration
Span Spacing SNOW LOAD:30 PSF
RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-6" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-6" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5116":2.5"MIN EMBEDMENT
5'-4" 2'-1" 4'-0' 2'-0" STAGGERED
DETAIL SNR-DC-00436 STRUCTURAL NOTES:
RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE • INSTALLERS SHALL NOTIFY
AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-7" 16" DETAIL SNR-DC-00436 5'•4" 2'-1" 4'-0" 2'•0" STAGGERED ENGINEER OF ANY POTENTIAL
STRUCTURAL ISSUES
D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'-0" OBSERVED PRIOR TO
AZIM:124" AZIM:124° PROCEEDING WI
PITCH:30° PITCH:30° INSTALLATION.
• IF ARRAY(EXCLUDING SKIRT)
IS WITHIN 12"BOUNDARY
REGION OF ANY ROOF PLANE
EDGES(EXCEPT VALLEYS),
} 10'-7" 20'-9'• _ 8" THEN ATTACHMENTS NEED
- -
TO BE ADDED AND OVERHANG
�•�g•• REDUCED WITHIN THE 12"
- = 1'-11" BOUNDARY REGION ONLY AS
FOLLOWS:
11.-7" ••ASPACING INDICATED ON
LLOWABLE ATTACHMENT
Ill' _ PLANS TO BE REDUCED BY
-__-__.I 50%
1t-7 limo .. �,.
..ALLOWABLE OVERHANG
•
INDICATED ON PLANS TO BE
6'
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
3' 1,7„ -- • — INDICATED ON PLANS
—6'-11"— 13'-10" 13'-10" —7'-3"___.i
17'-7" sunrun
D3-AR-03-SCALE:1/8"=1'-0" f1180120
AZIM:304° •os„v,ES.ST°NG91•iru,ruxnaN.Mk unman+
PITCH:30° F.0
"2'-5" -_ CUSTOMER RESIDENCE:
17.-3" - 34'6" ----- I MARIA FARIAS
._-_ _ 75 HEMEON DR,YARMOUTH,
MA,02673
4'-4" 3.
TEL.(508)360-1464
} APN:YARM-000038-000102
I I� STRUC ° PROJECT NUMBER:
oML Ey,1Ror4y,, 223R-075FAR1
d
1' ?�� VINCENT �G DESIGNER: (415)580-8920 ex3
g MWUMVANEZA m MD ALAM
5-9" CIVIL
SHEET
4` LE `��°e LAYOUT
• REV.A 10/22/2022
SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0
120/240 VAC
SINGLE PHASE
SERVICE
METER#:
< O EVERSOURCE 2283761
UTILITY
GRID I - NOTE:TOTAL PV BACKFEED=31A
1 USED FOR INTERCONNECTION
/ EXISTING
100A MAIN CALCULATIONS
l
1 BREAKER
�� EXISTING (N)MA SMART SOLAREDGE TECHNOLOGIES:
/ (N)LOCKABLE UTILITY SE6000H-USSN WITH
�� 125A MAIN BLADE TYPE REVENUE REVENUE GRADE METERING
FACILITY — — PANEL AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX
METER PV MODULES
LOADS o3 '3 P T OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY
�,� A �' // CO LTD:LR4-60HPH-365M
i
(23)MODULES
~ �I ��� O ~~/ �_ - / OPTIMIZERS WIRED IN:
- I I (1)SERIES OF(12)OPTIMIZERS
(N)35A -1= SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT ' (1)SERIES OF(11)OPTIMIZERS
PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401
OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE s u n r u n
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 #180120
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 60s ANTES STATO.u.,A,TAUNTON,.02700.7331
Mare 3
FAA 0
CUSTOMER RESIDENCE:
MARIA FARIAS
75 HEMEON DR,YARMOUTH,
MA,02673
MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS:
LONG!GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC TEL.(508)360-1464
TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC APN:YARM-000038-000102
LR4-60HPH-365M: 365 W MAX INPUT ISC: 11.75 ADC PROJECT NUMBER:
OPEN CIRCUIT VOLTAGE: 40.7 V MAX OUTPUT CURRENT: 15 ADC
MAX POWER VOLTAGE 34.2 V 223R-075FARI
SHORT CIRCUIT CURRENT: 11.43 A
DESIGNER: 1415)580.6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1
SYSTEM SIZE: 8395 W MD ALAM
SYSTEM OPEN CIRCUIT VOLTAGE: 12 V SHEET
SYSTEM OPERATING VOLTAGE: 380 V ELECTRICAL
MAX ALLOWABLE DC VOLTAGE: 480 V
SYSTEM OPERATING CURRENT: 22.09 A REV A 10/22/2022
SYSTEM SHORT CIRCUIT CURRENT: 30 A
PAGE PV-4.0
4\WARNING INVERTER 1 NOTES AND SPECIFICATIONS
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
([[Cl. RICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION NO,OR
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 499 ,',, •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON UNE AND LOAD WORDS.COLORS AND SYMBOLS.
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S).NEC 2020.69053 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4201/,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S),
SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODES)'NEC 2020:690.13(B)
WARNING: PHOTOVOLTAIC
/\WAR POWER SOURCE
LABEL LOCATION
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. ---
AND PV SOLAR ELECTRIC PER CODE(S)'NEC 2020:690.31(D)(2),IFC 2012.
SYSTEM 8051114 CAUTION :
LABEL LOCATION:
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S):NEC 2020.705.12(C)
WARNING
">PIGsuTt�OWNSWfTCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS , '
OVERCURRENT DEVICE LABEL LOCATION \ 40,
INSTALLED WITHIN 3'OF RAPID SHUT DOWN _
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020.890.56(CX2),IFC s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2016:1204.5.3
OCPD(IF APPLICABLE).
PER CODE(S)NEC 2020 4„
7061211,i,. . SOLAR PANELS ON ROOF
AWARNING SOLAR PV SYSTEM EQUIPPED #180120
406 s STNCS1xw.uurta.W,027110-713+
PHOTOVOLTAIC
PANEL EM WITH RAPID SHUTDOWN _ °E°
CO
DO NOT ADD LOADS CUSTOMER RESIDENCE:
MARIA FARIAS
LABEL LOCATION: 75 HEMEON DR.YARMOUTH,
PHOTOVOLTAIC AC COMBINER(IF MAIN PANEL A N D P V MA,02673
APPLICABLE)
PER CODE(S).NEC 2020:705.12(D)(2X3)(c) 3" TURN RAPID SHUTDOWN BREAKER DISCONNECT
SWITCH TO THE"OFF" WWIw,,,E„ELECIIIIC SERVICE ENTRANCE TEL(508)360-1464
POSMON TO SHUT DOWN APN:YARM-000038-000102
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE —INVERTER (EXT) PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT:25.00 AMPS - SHOCK HAZARD IN THE AC DISCONNECT 223R-075FARI ARRAY.
1111 —PV PRODUCTION METERNOMINAL OPERATING AC VOLTAGE 240 VAC ARRAY. —PV PRODUCTION METER
DESIGNER: (415)580-6920 ex3
LOCATION. j 75 HEMEON DR, YARMOUTH, MA, 02673
AC DISCONNECT(S),
MD ALAM
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION `-S SHEET
PER CODES)NEC 2020.690.54 LABEL LOCATION.
ON OR NO MORE THAT i M(3 FT)FROM THE SERVICE PER CODE(S)'NEC 2020:705.10,710.10 SIGNAGE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 10/22/2022
PER CODE(S).NEC 2020:690.56(C)
PAGE PV-5.0