Loading...
HomeMy WebLinkAboutBLDE-23-002262 or Commonwealth of Official Use Only • Massachusetts tilt Permit No. BLDE-23-002262 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:10/27/2022 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 75 HEMEON DR Owner or Tenant FARIAS-CARVALHO MARIA D TR Telephone No. Owner's Address THE 75 HEMEON DR RLTY TRUST, 75 HEMEON DR,WEST YARMOUTH, MA 02673 Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system (23 Panels 8.395 KW)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiatine Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alertine Devices No.of Dishwashers Space/Area Heating KW Local 0 Municipal ❑ Other: Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Siens No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: (When required by municipal policy.) Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE 0 BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE:$150.00 (covi crIvq-i\s /z,12¢/2Z 0 iC /� ,; _.� ' - II Official Use Only il CComnwnaealth o/ ad 1t1 =s �CJif e urlmenl o� rile�rv' OCT 2 6 '0j��T(L No ��/� Will Occup c and Fee Checked --.. / BOARD OF FIRE PREVENTION RiEG LA.TION -�,e-� II (leave blank t.,UILDING D P, APPLICATION FOR PERMIT Te _'—'-- . - ' CTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 10/24/2022 City or Town of: To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number)75 HEMEON DR Owner or Tenant Maria Farias Telephone No. (508)360-1464 Owner's Address 75 HEMEON DR Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes ® No ❑ (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a rooftop mounted photovoltaic solar energy system consisting of 23 solar panels producing 8.395 KW DC with No ESS Completion of the following table may be waived by the Inspector of Wires. .oTotal No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Tf Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- D No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALAR\IS No.of Zones of No.of Switches No.of Gas Burners No. Initiatinggon Deten and In Devices No.of Ran es No.of Air Cond. Total No.of Alerting Devices g Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices Municipal 1-1 No.of Dishwashers Space/Area Heating KW Loral❑ Connection Otla`" No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water Kam, No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: g No.of Devices or Equivalent OTHER:Roof Mounted Solar h additional detail ifdesired,or as required by the Inspector ofWires. Attac add a e 9 P Estimated Value of Electrical Work: $11,459.00 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of pedury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature 714 LIC.NO.:21136 A (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd.Taunton, MA 02780 Alt.Tel.No.:978793-7881 *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)0 owner 0 owner's agent. Owner/Agent Signature Telephone No. PERMIT FEE: $ ?L.t4 &rtArn POI-Willi qetazio e aS-i-r\1a P.er-vo i-rs E svnrull . C2v4 ; Lf61• i h SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION •SYSTEM SIZE:8395W DC.6000W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBCIIEBC), M SOLAR MODULES PV-1.0 COVER SHEET •MODULES:(23)LONG!GREEN ENERGY TECHNOLOGY CO MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION ® SERVICE ENTRANCE LTD:ERTERSPH)65M I•PHOTOVOLTAIC , , ��= PV-3.0 SITE LAYOPU N •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. •RACKIN•USSN MP MAIN PANEL =WM PV-4.0 ELECTRICAL •RACKING:RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. SEE DETAIL SNR-DC-00436 SNR MOUNT •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT&SKIRT PV-5.0 SIGNAGE GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER nj CHIMNEY •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LA ATTIC VENT •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER CJ FLUSH ATTIC VENT MODULES,ARE CLASS A FIRE RATED. , PVC PIPE VENT •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) ® METAL PIPE VENT CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC AC DISCONNECT(S) ^ cJ SATELLITE DISH •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. DC n DC DISCONNECT(S) , FIRE SETBACKS •11.43 AMPS MODULE SHORT CIRCUIT CURRENT. r11 •17.85 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)&690.8(b)]. CB IQ COMBINER BOX .',;•1 HARDSCAPE •PV INSTALLATION COMPLIES WITH THE NEC 2020 ARTICLE 690.12(BX2). CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE I— INTERIOR EQUIPMENT -PL- PROPERTY LINE LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION L J SHOWN AS DASHED SCALE NTS A AMPERE sunrun AC ALTERNATING CURRENT AFC! ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION DC DIRECT CURRENT #180120 (E) EXISTING s MIES ST•r.n91 MVO.uwnw.w.027ro7. ESS ENERGY STORAGE SYSTEM 1.0t. .0t 0 EXT EXTERIOR INT INTERIOR CUSTOMER RESIDENCE: MAG MAGNETIC MARIA FARIAS MSP MAIN SERVICE PANEL 75 HEMEON DR,YARMOUTH, (N) NEW MA,02673 NTS NOT TO SCALE OC ON CENTER TEL.(508)360-1464 r PRE-FABRICATED SF-FAB POUNDS PER SQUARE FOOT APN:YARM-000038-000102 '75 HeniC'.. West Yarmouth,MA PROJECT NUMBER: PV PHOTOVOLTAIC RED RAPID SHUTDOWN DEVICE 223R-075FARI TL TRANSFORMERLESS DESIGNER: (415)5808920 ex3 TYP TYPICAL V VOLTS MD ALAM W WATTS SHEET REV NAME - DATE COMMENTS COVER SHEET REV:A 10/22/2022 PAGE PV-1.0 Ll „Or) ...zz ::„,..z..„ ARRAY TRUE MAG PV AREA SITE PLAN-SCALE=3/64"=1'-0" PITCH AZIM AZIM (SOFT) /� AR-01 30° 124° 138° 196.1 ,'(�I� AR-02 30° 124° 138° 156.9 i''''''..s.' AR-03 30° 304° 318° 98 q d' \ 't (N)ARRAY AR-02 (E)GATE C q (N)ARRAY AR-03-- 4.' 44, A;i ..........„.; ..•,...:,,...:..;,-.. :.... .7 (E)RESIDENCE ,,, s �O (E)FENCE41I �`r z sunrun ilit (N)ARRAY AR-01 M q , . '''''----,.. , / #180120 m0.60 ,wrrw.w.onam1 0 q Q, CUSTOMER RESIDENCE: MARIA FARIAS 75 HEMEON DR,YARMOUTH, rMP q MA,02673 ®�®� \ TEL(5 -1464 APN:YARM-000038-000102 a. PROJECTECT N NUMBER: 223 q DESIGNER: DESIGNER: (415)5808920 ex MD ALAM SHEET SITE PLAN REV.A 10/22/2022 PAGE PV-2.O ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF Name T V re Detail OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing SNOW LOAD:30 PSF RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED: AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-6" 16" COMP,SEE DETAIL SNR-DC-00436 5'-4" 2'-1" 4'-0" 2'-0" STAGGERED 140 MPH 3-SEC GUST. S.S.LAG SCREWS: AR-02 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 12'-6" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5116":2.5"MIN EMBEDMENT 5'-4" 2'-1" 4'-0' 2'-0" STAGGERED DETAIL SNR-DC-00436 STRUCTURAL NOTES: RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE • INSTALLERS SHALL NOTIFY AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-7" 16" DETAIL SNR-DC-00436 5'•4" 2'-1" 4'-0" 2'•0" STAGGERED ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES D1-AR-01-SCALE:1/8"=1'-0" D2-AR-02-SCALE:1/8"=1'-0" OBSERVED PRIOR TO AZIM:124" AZIM:124° PROCEEDING WI PITCH:30° PITCH:30° INSTALLATION. • IF ARRAY(EXCLUDING SKIRT) IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE EDGES(EXCEPT VALLEYS), } 10'-7" 20'-9'• _ 8" THEN ATTACHMENTS NEED - - TO BE ADDED AND OVERHANG �•�g•• REDUCED WITHIN THE 12" - = 1'-11" BOUNDARY REGION ONLY AS FOLLOWS: 11.-7" ••ASPACING INDICATED ON LLOWABLE ATTACHMENT Ill' _ PLANS TO BE REDUCED BY -__-__.I 50% 1t-7 limo .. �,. ..ALLOWABLE OVERHANG • INDICATED ON PLANS TO BE 6' 1/5TH OF ALLOWABLE ATTACHMENT SPACING 3' 1,7„ -- • — INDICATED ON PLANS —6'-11"— 13'-10" 13'-10" —7'-3"___.i 17'-7" sunrun D3-AR-03-SCALE:1/8"=1'-0" f1180120 AZIM:304° •os„v,ES.ST°NG91•iru,ruxnaN.Mk unman+ PITCH:30° F.0 "2'-5" -_ CUSTOMER RESIDENCE: 17.-3" - 34'6" ----- I MARIA FARIAS ._-_ _ 75 HEMEON DR,YARMOUTH, MA,02673 4'-4" 3. TEL.(508)360-1464 } APN:YARM-000038-000102 I I� STRUC ° PROJECT NUMBER: oML Ey,1Ror4y,, 223R-075FAR1 d 1' ?�� VINCENT �G DESIGNER: (415)580-8920 ex3 g MWUMVANEZA m MD ALAM 5-9" CIVIL SHEET 4` LE `��°e LAYOUT • REV.A 10/22/2022 SEE SITE PLAN FOR NORTH ARROW PAGE PV-3.0 120/240 VAC SINGLE PHASE SERVICE METER#: < O EVERSOURCE 2283761 UTILITY GRID I - NOTE:TOTAL PV BACKFEED=31A 1 USED FOR INTERCONNECTION / EXISTING 100A MAIN CALCULATIONS l 1 BREAKER �� EXISTING (N)MA SMART SOLAREDGE TECHNOLOGIES: / (N)LOCKABLE UTILITY SE6000H-USSN WITH �� 125A MAIN BLADE TYPE REVENUE REVENUE GRADE METERING FACILITY — — PANEL AC DISCONNECT 6000 WATT INVERTER JUNCTION BOX METER PV MODULES LOADS o3 '3 P T OR EQUIVALENT 1 LONGI GREEN ENERGY TECHNOLOGY �,� A �' // CO LTD:LR4-60HPH-365M i (23)MODULES ~ �I ��� O ~~/ �_ - / OPTIMIZERS WIRED IN: - I I (1)SERIES OF(12)OPTIMIZERS (N)35A -1= SQUARED 240V METER SOCKET LOAD RATED DC DISCONNECT ' (1)SERIES OF(11)OPTIMIZERS PV BREAKER AT DU222RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN -SOLAREDGE POWER OPTIMIZERS OPPOSITE END 3R,60A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P401 OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS- (LINE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE s u n r u n # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 #180120 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 60s ANTES STATO.u.,A,TAUNTON,.02700.7331 Mare 3 FAA 0 CUSTOMER RESIDENCE: MARIA FARIAS 75 HEMEON DR,YARMOUTH, MA,02673 MODULE CHARACTERISTICS P401 OPTIMIZER CHARACTERISTICS: LONG!GREEN ENERGY MIN INPUT VOLTAGE: 8 VDC TEL.(508)360-1464 TECHNOLOGY CO LTD: MAX INPUT VOLTAGE: 60 VDC APN:YARM-000038-000102 LR4-60HPH-365M: 365 W MAX INPUT ISC: 11.75 ADC PROJECT NUMBER: OPEN CIRCUIT VOLTAGE: 40.7 V MAX OUTPUT CURRENT: 15 ADC MAX POWER VOLTAGE 34.2 V 223R-075FARI SHORT CIRCUIT CURRENT: 11.43 A DESIGNER: 1415)580.6920 ex3 SYSTEM CHARACTERISTICS-INVERTER 1 SYSTEM SIZE: 8395 W MD ALAM SYSTEM OPEN CIRCUIT VOLTAGE: 12 V SHEET SYSTEM OPERATING VOLTAGE: 380 V ELECTRICAL MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 22.09 A REV A 10/22/2022 SYSTEM SHORT CIRCUIT CURRENT: 30 A PAGE PV-4.0 4\WARNING INVERTER 1 NOTES AND SPECIFICATIONS •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE ([[Cl. RICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION NO,OR IF REQUESTED BY THE LOCAL AHJ. MAXIMUM SYSTEM VOLTAGE: 499 ,',, •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON UNE AND LOAD WORDS.COLORS AND SYMBOLS. •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. THE OPEN POSITION INVERTER(S),DC DISCONNECT(S) •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S).NEC 2020.69053 INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4201/,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODES)'NEC 2020:690.13(B) WARNING: PHOTOVOLTAIC /\WAR POWER SOURCE LABEL LOCATION DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. --- AND PV SOLAR ELECTRIC PER CODE(S)'NEC 2020:690.31(D)(2),IFC 2012. SYSTEM 8051114 CAUTION : LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S):NEC 2020.705.12(C) WARNING ">PIGsuTt�OWNSWfTCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS , ' OVERCURRENT DEVICE LABEL LOCATION \ 40, INSTALLED WITHIN 3'OF RAPID SHUT DOWN _ LABEL LOCATION: SWITCH PER CODE(S):NEC 2020.890.56(CX2),IFC s u n r u n ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2016:1204.5.3 OCPD(IF APPLICABLE). PER CODE(S)NEC 2020 4„ 7061211,i,. . SOLAR PANELS ON ROOF AWARNING SOLAR PV SYSTEM EQUIPPED #180120 406 s STNCS1xw.uurta.W,027110-713+ PHOTOVOLTAIC PANEL EM WITH RAPID SHUTDOWN _ °E° CO DO NOT ADD LOADS CUSTOMER RESIDENCE: MARIA FARIAS LABEL LOCATION: 75 HEMEON DR.YARMOUTH, PHOTOVOLTAIC AC COMBINER(IF MAIN PANEL A N D P V MA,02673 APPLICABLE) PER CODE(S).NEC 2020:705.12(D)(2X3)(c) 3" TURN RAPID SHUTDOWN BREAKER DISCONNECT SWITCH TO THE"OFF" WWIw,,,E„ELECIIIIC SERVICE ENTRANCE TEL(508)360-1464 POSMON TO SHUT DOWN APN:YARM-000038-000102 PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE —INVERTER (EXT) PROJECT NUMBER: MAXIMUM AC OPERATING CURRENT:25.00 AMPS - SHOCK HAZARD IN THE AC DISCONNECT 223R-075FARI ARRAY. 1111 —PV PRODUCTION METERNOMINAL OPERATING AC VOLTAGE 240 VAC ARRAY. —PV PRODUCTION METER DESIGNER: (415)580-6920 ex3 LOCATION. j 75 HEMEON DR, YARMOUTH, MA, 02673 AC DISCONNECT(S), MD ALAM AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION `-S SHEET PER CODES)NEC 2020.690.54 LABEL LOCATION. ON OR NO MORE THAT i M(3 FT)FROM THE SERVICE PER CODE(S)'NEC 2020:705.10,710.10 SIGNAGE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. REV:A 10/22/2022 PER CODE(S).NEC 2020:690.56(C) PAGE PV-5.0