HomeMy WebLinkAboutBLDE-22-006485 Commonwealth of Official Use Only
/r Massachusetts
Permit No. BLDE-22-006485
' BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked
[Rev.1/07]
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:5/11/2022
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 83 IROQUOIS BLVD
Owner or Tenant Timothy Laughlin Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(12 Panels 4.08 KW)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total
Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiatine Devices
No.of Ranges No.of Air Cond. Total No.of Alerting Devices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alertine Devices
No.of Dishwashers Space/Area Heating KW Local ❑ Municipal ❑ Other:
Connection
No.of Dryers Heating Appliances Kai' Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of [No.of Ballasts Data Wiring:
Heaters Siens No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
Estimated Value of Electrical Work: (When required by municipal policy.)
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE:INSURANCE 0 BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.) Bus.Tel.No.:
Address: 166 Hunt Rd,Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $150.00
•
/t2,tv 44 "
�lf
(
' — ' Commonwealth.o//YlaSsachudetti � Official Use Only
to—' -it �—'C.Z—(Q`e
lid+— c� p c�- S Permit No.
-mil aLJepartment o ire Serviced
•e _C=F Occupancy and Fee Checked
BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: -Li -g6sEt
City or Town of: Ye,fY}(' h To the Inspector of Wires:
By this application the undersigned gives notice of his orj7errI 1intention to perform the electrical work described below.
Location(Street&Number) �� .l ro ` I S 1 4Ud
Owner or Tenant I f fl('- 1„2n N i n Telephone No.Kaa121C10
Owner's Address ` to - cr tove,
Is this permit in conjunction with a building permit? Yes+ No n (Check Appropriate Box)
Purpose of Building rL�t`j/ Utility Authorization No.
Existing Service Ai Amps / �V Undgrd Volts Overhead Und rd I I No.of Meters I
New Service Amps / Volts Overhead I 1 Undgrd n No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: inc{( I I GT ion n l cc r (�n-ed
cpT ovn«nlc. Mhr 5cpteM. 4 _pQnet LJJ8 KLJ
Completion of the following table may be waived by the Inspector of Wires.
No.
rano KVA
Total
No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Total No.of AlertingDevices
Tons
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other
Connection
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Data Wiring:
Heaters Signs Ballasts No.of Devices or Equivalent
No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring:
No.of Devices or Equivalent
OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
Estimated Valu of rical Work: 7120 z, (When required by municipal policy.)
Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such cove e is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE BOND ❑ OTHER ❑ (Specify:)
I certify,under t p 'ns and pen hies of perjury,that the information on this application is true and complete.
FIRM NAME: LIC.NO.:{9j n, 11
Licensee: Signature f LIC.NO.:
(If applicable enter "exempt"i thelice fensenu e berl4 „L.. y� Bus.Tel.No.•`I 1� qq '.
Address: 695. Mgie _ io/IUf_St1 t , 1owl/cy) r M11 , CN -y Y0 Alt.Tel.No.:
*Per M.G.L. c. 147, sf 57-61,security work requires Depailuient of Public Safety"S"License: Lic. No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑ owner ❑owner's agent.
Owner/Agent
Signature Telephone No. PERMIT FEE: $
1.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS
PAGE# DESCRIPTION
•SYSTEM SIZE:4080W DC,3800W AC •ALL WORK SHALL COMPLY WITH MA 9th Ed.CMR 780(2015 IRC/IBC/IEBC), p SOLAR MODULES PV-1.0 COVER SHEET
•MODULES:(12)JA SOLAR:JAM60S10-340/MR MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION SERVICE ENTRANCE
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. 6..WA
-9 PV-2.0 SITE PLAN
SE3800H-USS3 •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2020. I
PV-3.0 LAYOUT
•RACKING:SNAPNRACK RLU;RL UNIVERSAL,SPEEDSEAL MP MAIN PANEL
TRACK ON COMP,SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2020. PV-4.0 ELECTRICAL
SNR MOUNT
•PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY SP SUB-PANEL SNR MOUNT 8 SKIRT PV-5.0 SIGNAGE
GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
. •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. LC PV LOAD CENTER
CHIMNEY
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. ATTIC VENT
•SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II PM DEDICATED PV METER .] FLUSH ATTIC VENT
MODULES,ARE CLASS A FIRE RATED. ,, PVC PIPE VENT
•RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL INV INVERTER(S) .x METAL PIPE VENT
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). ® T-VENT
AC
•CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). AC DISCONNECT(S)
CP SATELLITE DISH
•ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. OC
FIRE SETBACKS
•10.46 AMPS MODULE SHORT CIRCUIT CURRENT. DC DISCONNECT(S)
�.
•16.34 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(a)8 690.8(b)]. CB IQ COMBINER BOX L__:J HARDSCAPE
•PV INSTALLATION COMPLIES WITH THE NEC 2017 ARTICLE 690.12(B)(2).
CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE I- INTERIOR EQUIPMENT —PL— PROPERTY LINE
LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION LI SHOWN AS DASHED
SCALE:NTS
A AMPERE s u n r u n
AC ALTERNATING CURRENT
AFC! ARC FAULT CIRCUIT INTERRUPTER
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION
OP *..•' .,,C,,;Tv V
DC DIRECT CURRENT #180120
I@ '�I (E) EXISTING 605 MYLES sruwLsN Bwo,TAUNTON MA,027e0-7331
ESS ENERGY STORAGE SYSTEM 0
OiclMeRep,blwvee1 - EXT EXTERIOR
0y' - .` INT INTERIOR CUSTOMER RESIDENCE:
i MAG MAGNETIC TIMOTHY LAUGHLIN
MSP MAIN SERVICE PANEL 83 IROQUOIS BLVD,
a "' '' (N) NEW YARMOUTH,MA,02673
NTS NOT TO SCALE
sou OC ON CENTER TEL.(860)717-2790
r aPM M PRE-FAB PRE-FABRICATED APN:YARM-000024-000129
• PSF POUNDS PER SQUARE FOOT
See O PV PHOTOVOLTAIC
2e PROJECT NUMBER:
83 I/Oquc:' RSD RAPID SHUTDOWN DEVICE 223R-083LAUG
West Yar-t _ TL TRANSFORMERLESS DESIGNER: (415)580 6920 ex3
TYP TYPICAL
V VOLTS GERARD ANDES
W WATTS SHEET
REV NAME DATE COMMENTS COVER SHEET
REV:A 5/3/2022
PAGE PV-1.0
a
SITE PLAN-SCALE=1/16"=1'-0" ARRAY TRUE MAG PV AREA
PITCH AZIM AZIM (SOFT)
is AR-01 18° 242° 256° 217.3
es-
AMP 30
rev g po
l I PS'
n
L
•
O
/\
o` ° o
c IIE®
sti. ,
0.
...------"----- \
qv
...-----"----- \
t
(N)ARRAY AR-011
1 (E)RESIDENCE
1
I,,
sunrun
/ #180120
\ 4, / FAX
uncs sramsM sivp rnuNrw.NA oveo-»i
RAC.o
%0
CUSTOMER RESIDENCE:
TIMOTHY
g / 83 IROQUOIS BLVD,
YARMOUTH,MA,02673
W TEL.(660)717-2790
/ AP ECT-000024-00
PROJECT NUMBER::
223R-063LAUG
W
4 DESIGNER: (415)580-6920 ex3
GERARD ANDES
SHEET
es- SITE PLAN
REV:A 5/3/2022
PAGE PV-2.O
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION DESIGN CRITERIA
Max OC Max Landscape Max Landscape Max Portrait Max Portrait MAX DISTRIBUTED LOAD:3 PSF
Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration SNOW LOAD:30 PSF
11'- RL UNIVERSAL,SPEEDSEAL TRACK ON WIND SPEED:
AR-01 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11" 24" COMP,SEE DETAIL SNR-DC-00436 6'-0" 2'-4" 4'-0" 1'-10" STAGGERED 140 MPH 3-SEC GUST.
S.S.LAG SCREWS:
5/16":2.5"MIN EMBEDMENT
D1-AR-01-SCALE:1/4"=1.-0" STRUCTURAL NOTES:
AZIM:242° • INSTALLERS SHALL NOTIFY
PITCH:18° ENGINEER OF ANY POTENTIAL
STRUCTURAL ISSUES
OBSERVED PRIOR TO
PROCEEDING W/
INSTALLATION.
• IF ARRAY(EXCLUDING SKIRT)
IS WITHIN 12"BOUNDARY
REGION OF ANY ROOF PLANE
EDGES(EXCEPT VALLEYS),
THEN ATTACHMENTS NEED
TO BE ADDED AND OVERHANG
28' -—3'—, REDUCED WITHIN THE 12"
BOUNDARY REGION ONLY AS
FOLLOWS:
••ALLOWABLE ATTACHMENT
SPACING INDICATED ON
PLANS TO BE REDUCED BY
Ell— I. = WI •• _
50%
} ••ALLOWABLE OVERHANG
INDICATED ON PLANS TO BE
1/5TH OF ALLOWABLE
ATTACHMENT SPACING
INDICATED ON PLANS
9'-11"
_ _ _ MEI sunrun
4'-11" #180120
i • MI
6Mb MYLES ST NDIS"aLVD TAUNTON MA o2760-7331
PHONE 0
FAX 0
CUSTOMER RESIDENCE:
TIMOTHY LAUGHLIN
83 IROQUOIS BLVD,
11'-2" .__..__---. .__—.._. ____ .__._._-16'-10"_-----_. ,-3'— YARMOUTH,MA,02673
TEL.(860)717-2790
APN:YARM-000024-000129
PROJECT NUMBER:
STRUCT 223R-083LAUG
ONL
et
OF M4Sgq DESIGNER: (415)580-6920 ex3
GERARD ANDES
(! N1 \MWUMVANEZA N SHEET
CIVIL LAYOUT
SEE SITE PLAN FOR NORTH ARROW l ONRIEHG"' REV:A 5/3/2022
PAGE PV-3.0
120/240 VAC
SINGLE PHASE
SERVICE
OMETER#: NOTE:TOTAL PV BACKFEED=20A
EVERSOURCE 2305598 USED FOR INTERCONNECTION
UTILITY CALCULATIONS
GRID I
1 EXISTING
/ 100A MAIN ,
l BREAKER
I SOLAREDGE TECHNOLOGIES:
�� EXISTING SE3800H-US WITH REVENUE
iS. 100A (N)MA SMART GRADE METERING(PN
___ MAIN (N)LOCKABLE UTILITY SE3800H-USS3),3800 WATT
FACILITY PANEL BLADE TYPE REVENUE INVERTER
AC DISCONNECT METER 3800 WATT INVERTER JUNCTION BOX PV MODULES
LOADS
TC� 0 OR EQUIVALENT
O JA SOLAR:JAM60S10-340/MR
13 •Diu ® Z f — 4—/ F / (12)MODULES
WIRED IN:
• v v / OPTIMIZERS(1)SERIES OF(12)OPTIMIZERS
• I 1
(N)20Ar= SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT
PV BREAKER AT DU221RB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN —SOLAREDGE POWER OPTIMIZERS
OPPOSITE END 3R,30A,2P UTILITY SIDE OF CIRCUIT COMPLIANT P370
OF BUSBAR 120/240VAC CONNECTS TO TOP LUGS-
(LINE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
• # CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPERI
2- 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/THWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
SOS MYLES STANDISH BLVD,TAUNTON,MA,02 7 80-7 3 31
PHONED
FAX 0
CUSTOMER RESIDENCE:
TIMOTHY LAUGHLIN
83 IROQUOIS BLVD,
YARMOUTH,MA,02673
MODULE CHARACTERISTICS P370 OPTIMIZER CHARACTERISTICS: TEL.(860)717-2790
JA SOLAR:JAM60S10-340/MR: 340 W MIN INPUT VOLTAGE: 8 VDC APR:YARM-000024-000129
OPEN CIRCUIT VOLTAGE: 41.55 V MAX INPUT VOLTAGE: 60 VDC PROJECT NUMBER:
MAX POWER VOLTAGE: 34.73 V MAX INPUT ISC: 11 ADC 223R-083LAUG
SHORT CIRCUIT CURRENT: 10.46 A MAX OUTPUT CURRENT 15 ADC
DESIGNER: (415)580-6920 ex3
SYSTEM CHARACTERISTICS-INVERTER 1 GERARD ANDES
SYSTEM SIZE: 4080 W SHEET
SYSTEM OPEN CIRCUIT VOLTAGE: 12 V ELECTRICAL
SYSTEM OPERATING VOLTAGE: 380 V
MAX ALLOWABLE DC VOLTAGE 480 V
SYSTEM OPERATING CURRENT: 10.74 A
REV:A 5/3/2022
SYSTEM SHORT CIRCUIT CURRENT: 15 A PAGE
PV-4.0
AW A R N I N G INVERTER 1 NOTES AND SPECIFICATIONS:
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2020 ARTICLE
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC DC DISCONNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
IF REQUESTED BY THE LOCAL AHJ.
MAXIMUM SYSTEM VOLTAGE: 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
•LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
SIDES MAY BE ENERGIZED IN LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
THE OPEN POSITION INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABIUTY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2020:690.53 INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPUCABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2020:690.13(8)
WARNING: PHOTOVOLTAIC
\WARNING POWER SOURCE
LABEL LOCATION:
DUAL POWER SUPPLY INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
SOURCES:UTILITY GRID AT EACH TURN,ABOVE AND BELOW PENETRATIONS,
ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
AND PV SOLAR ELECTRIC PER CODE(S):NEC 2020:690.31(D)(2),IFC 2012:
SYSTEM 605.11.1.4
LABEL LOCATION: CAUTION :
UTILITY SERVICE METER AND MAIN
SERVICE PANEL.
PER CODE(S):NEC 2020:705.12(C)
/AWARNING � / MULTIPLE SOURCES OF POWER
rPIDSHUTDOWNSWITCH
OR SOLAR PV SYSTEM (1/0' DO NOT RELOCATE THIS
OVERCURRENT DEVICE LABEL LOCATION: I
INSTALLED WITHIN 3'OF RAPID SHUT DOWN Jl
LABEL LOCATION: SWITCH PER CODE(S):NEC 2020:690.56(C)(2).IFC S O LA R PANELS s u n r u n
ADJACENT TO PV BREAKER AND ESS 2012:605.11.1,IFC 2018:1204.5.3
OCPD(IF APPLICABLE). ON ROOF
PER CODE(S).NEC 2020: 4" t •
705.12(B)(3)(2)
/\WARNING SOLAR PV SYSTEM EQUIPPED INVERTER (EXT) n160120
NS Mn w rs STAnoi BLVD,T•UNTO.u•,02700-73.31
NE
PHOTOVOLTAIC
COMBINERPANELEM F
WITH RAPID SHUTDOWN PRODUCTION o
.0
DO NOT ADD LOADS METER MAIN PANEL CUSTOMER RESIDENCE:
• TIMOTHY LAUGHLIN
LABEL LOCATION: 83 IROQUOIS BLVD,
PHOTOVOLTAIC AC COMBINER(IF
• APPUCABLE).
YARMOUTH,MA,02673
PER CODE(S):NEC 2020:705.12(D)(2)(3)(c) 3" TURN RAPID SHUTDOWN
SWITCH TO THE"OFF" o"a. « I TEL.(860)717-2790
POSITION TO SHUT DOWN APN:YARM-000024-000129
PV SYSTEM DISCONNECT PV SYSTEM AND REDUCE AC DISCONNECT - SERVICE ENTRANCE PROJECT NUMBER:
MAXIMUM AC OPERATING CURRENT:15.83 AMPS SHOCK HAZARD IN THE
ARRAY. Iri
223R-083LAUG
ll DESIGNER: (415)580-6920 ex3
NOMINAL OPERATING AC VOLTAGE: 240 VAC
LABEL LOCATION: 83 IROQUOIS BLVD, YARMOUTH, MA, 02673 GERARD ANDES
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF
INTERCONNECTION. ` ' —— SHEET
PER CODE(S):NEC 2020:690.54 LABEL LOCATION:
ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE PER CODE(S):NEC 2020:705.10,710.10 SIGNAGE
DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
ARE CONNECTED. REV:A 5/3/2022
PER CODE(S):NEC 2020:690.56(C)
PAGE PV-5.0