Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. l, ( Lot /O Zone of Contribution: In_ Out 'Acreage/0 pp - / Commercial: Residential: Street:_9 SI'v�` e/ Ael Village: (� Floor Plan: # Bedrooms: �S3 ! Owner: Installer: /�._.�i `) Address: Phone: Phone: Builder: Engineer: FJc L c,-7y jNc,i r-Om . Address: Phone Phone: N'A YES NO 1. Required#of copies received V. 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material; above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: V 5. Water line 10 ft from septic components Var.: l . 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: I ig 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I / .9. Leaching minimum 100 ft from wetlands Var.: fr 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: - 11.Tank/leaching minimum 10 ft from property line Var.: jV 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: _ 1 v 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.` 15. System not in top or subsoil (A,B horizons)or 5' removal I I . 16. Proposed contours are suitable v 17. System meets slope requirements-min. 1/8", '/"preferred I v __18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel L,/ 21. No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade ✓ 1 25. Inspection port on plastic chambers/leach field A/ 26. Electrical permit for pump chamber/Separate meter for duplexes ,/ 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size ✓ 28. Septic tank/pump chamber to be factory waterproofed I/ 29. Vent provided if leaching below 3 feet,under driveway/parking `/ 30. Buoyancy calculations for-tank/pump chamber 4/ 31. Engineer to inspect and certify soils: wall: commercial: I/ • 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature / 33.H-20 loading is subject to vehicular traffic,groundwater V 34.Title V Application and permit fee,installer signature t/ 35.Foundation footing min. 2 feet above adjusted ground water for new house V. 36. Deed Restriction required max. #bedrooms: max. flow: gpd v" 37. Check area lots for groundwater/Label groundwater in Assessor's Map ✓' Plan reviewed by: _ c;c: 3 _a,2 , a� -