Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND X 99• 1 EXIST. SPOT ELEV. --[99]--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 } TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 2500 GAL. SEPTIC TANK/PUMP CHAMBER COMBINATION LEACHING: 220 GPD (.74) = 298 SF REQUIRED 20.0' X 22.0' = 440 SF OK 440 SF X .74 = 325 GPD OK USE A 20.0' X 22.0' PRESSURE DOSED PIPE AND STONE LEACHING FIELD MA APPROVED DATE BOARD OF HEALTH SYSTEM PROFILE `""' `' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR PROVIDE INSPECTION PORT TO GRADE COMPARABLE MEANS FOR FUTURE LOCATION. 4" SCH40 PERFORATED PVC DOWN TO DRILL LAST HOLE IN EACH SAND AT BOTTOM LEACHING FIELD, LATERAL ON TOP TO VENT PROVIDE MIN. 20" DIAM. WATERTIGHT PROVIDE 4" THREADED COVER AND AIR WHILE LATERAL FILLS ACCESS COVERS TO WITHIN 6" OF FIN. GRADE LEBARON 1 A910 CAST IRON ACCESS FEMALE ADAPTOR & THREADED PLUG PORT H-20 CONSTRUCTION, 2"0 THREADED END CONNECTION 6 7' SCH 40 PV MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER EM $.52' 1 /4" SHIELDED ORIFICES 7.77 --- - _7 ,� e INV. 7.6' 2" INVERTS LEVEL AT 7.6' '2" PRESSURE LINE ' o0 00 o O o� o 0 � 7.1' L0 0° 2500 GAL H-10 10" SEPTIC TANK/ ORIFICES 4' ON CENTER 1 _ TEE PUMP CHAMBER COMBINATION BOTTOM LEACHING LEVEL AT EL. 7.1' LIHEr1 \2" CENTRAL FED MANIFOLD SEE DETAIL BELOW WEEP HOLE PITCH TO DRAIN BACK TO CONNECT ENDS PUMP CHAMBER- NO LOW SPOTS. 5' e D O O O, O O O O O O `O 0 0 0 0 0 0 OIL D0000000000000000000°00000000000000°0 3/4" TO 1 1 /2" DOUBLE WASHED STONE no0°0o,�0�000000000°0�0n0�0„0„0000000. 6" CRUSHED STONE OR MECHANICAL SIDE ELEVATION VIEW COMPACTION. (15.221 [21) ( 2.5 % SLOPE MIN.) WATERPROOF LEACHING FOUNDATION 18' SEPTIC TANK/ 48' FACILITY PUMP CHAMBER :7. 1' PRECAST H-10 RISERS (TYP.) 2'0 4.65' BUOYANCY CALC: 2"0 SCH40 PVC MANIFOLD 2500 H-10 TANK WEIGHT: 24,250 LBS WATERTIGHT ACCESS COVERS TO GRADE FEMALE ADAPTOR & THREADED PLUG 2" TO SCH 40 PVC PUMP PIT 11.83 x 6.33 x 4.53 x 62.4 = 21,168 UP (OK) 900 GAL.± THIS SIDE (TYP. BOTH ENDS)'' PITCH 330+ GAL RESERVE _ 005 FT/FT MIN. _______ ___________________ ___- PROVIDE QUICK DISCONNECT FOR PUMP j 1 I 1 ALARM AND CONTROL PANEL, 1 TO BE INSTALLED INSIDE ,. ,. BUILDING. ALARM TO BE ON INV. IN 4.65' 4.00` o SEPARATE CIRCUIT FROM PUMP 2" PRESSURE LINE w ZABEL FILTER (A100) 19" TEE SLOPE TO DRAIN BACK a w FLOAT SWITCH ALARM ON OUTLET TEE W/EXTENSION 9 SETTINGS: 0.25" WEEP HOLES 4 0 PUMP ON 6" MIN. 1500 GAL. CHECK VALVE I � 5" WORKING RANGE THIS SIDE MYERS SRM 4 I LEACHING FIELD w 5" OF BAFFLE j PUMP OFF 12" SUBMERSIBLE 4/10 HP PUMP of l I SYSTEM (OR EQUAL) 11 o ON BLOCK ( ) o00 000 0000 0 0 000o V) WATERPROOF 6" BAFFLE I 2500 GAL. SEPTIC TANK/ ACCESS FOR ROUTINE MAINTENANCE PUMP CHAMBER COMBINATION MUST BE PROVIDED FOR ZABEL (NOT TO SCALE) FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER CONNECT ENDS INSTALLATION FEMALE ADAPTOR & THREADED PLUG SCH 40 PVC PLAN VIEW PIPING DETAIL COMPACT BACKFILL (5) LATERALS 4' CENTER TO CENTER SEE LAYOUT DETAIL MIRAFI 140N FABRIC OVER STONE EL. 7.77` °o°°o0 °° °°°Oo°°o°°o°°o°°o°°o°°o°°o°°o°o°O°o°°o°°o°°o°°o1010°O o o °°o°°0 2" INV. EL. 7.6' 8" °0°G°� 0°�°0o°0000.000°0°G°G°G°G°o 0°00000°G°o 10000 o o° 0000 00GOG00 o0G0G000o0o0G0o0o00000o0o0G0G0G0o000oaG0G00000 R02 0G °G0o 6. 000000° 00o0o0oDa0o0o00000o0o0oDo0o0000000ooGa0o0oo°000o0o0oG Goo EL. 7.1' 00 0 0 0 0 0 O 0000000°OOOOo0o00°0000000OCf 0 0 0 0 0 0 0 O 2.0"0SCH40 PVC 8" TOTAL OF .75" - 1.5" STONE ORIFICE SHIELD OS200 WITH 1/4" ORIFICES DOUBLE WASHED ONLY ORENCO SYSTEMS INC DRILLED AT 4' O.C. PH. 1-800-348-9843 ALTERNATING UP AND DOWN CLEAN COMPACTED COARSE SAND FILL OR EQUAL SEE DETAIL DRILL DISTAL END ON TOP, UNDERNEATH LEACHING FIELD LEACHING FIELD SECTION NOT TO SCALE DEC DCE #22- > 74 7.4 /PA ED PA KING 50.M 0 PAVED o PARKING W �j W p 1J�� Wes- W i� -- W W W f--- -, 50 53.68 t \- / � OHE < - ° OHE OHE E 6.7 HE 0 0.0 - 100 J ' 000 BRIC I 1 CAUTION: H1 PATIO p �` 7 \ OVER HEAD ° ELECTRIC IN ' THIS AREA O o E'�SEMENT o EXISTING DWELLING U-) TOP OF FNDN EL. 6.8 CAUTION: #142 SEAVIEW GAS LINE IN � N THIS AREA c71 ' PATIO O N EXISTING DWELLING TOF = 7.1'/ (� 9 GILBERT J PATIO/ C� BENCHMARK PATIO CORNER EL. = 7.5' . BARN 100.00 G a 0 24.4 CAUTION: 8.52 LOTS 2 & 26 GAS LINE IN O c, THIS AREA $ 521 10,100± SEE PLANS FOR 7 8, PROPOSED SEPTIC 14 L7� TH1 142 SEAVIEW A SWALE 7.96 1 w "J / 0 0 O PRO E 116' MIL NER AT5' c, S p� E 5 V TG S S IN (AS TOP AT ELEV. 8' B�OF MAT EL. 3.6'± 1 5' REMOVAL F UNSUIT SOIL REQUIRED AROUND PER ETER OF CHING FACILITY, 100 •p0 DOWN TO SUI ABLE SOIL YER. REPLACE PROVIDE 132' OF 40 L LI ER AT 5' W CLEAN D. SAND, T MEET OFF SAS IN AREA E OPAT S CI 310 C R 15.255(3) ELEV. 7.6', AT EL 8T t 1 /4" 0 HOLE AT 4' O.C. ALTERNATE BETWEEN TOP & BOTTOM OF PIPE. EXACT DIAMETER HOLES SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS PRIOR TO PLACING PIPE. 20 �- tUj 15 w w z 0 w 10 J Q 0 ~ 5 ADJ. G.W. EL.= 2.1' G.W AT EL.= 1.0' 2.0" 0 SCH-40 PVC LATERAL SNAP -ON l C SHIELD \ DRAINAGE SLOTS ORIFICE SHIELD OS200 ORENCO SYSTEMS INC PH. 1-800-348-9843 OR EQUAL. 0 a 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP 114 " ORIFICE AT 4' O.0 (SEE ORIFICE DETAIL) CLEANOUT (TYP.) 0 N INSPECTION PORT c 0 �i „3 0' J. 0' > 14: > 4.0' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. to V to 2 f 0 O J 0 03 Cb P a Locus \ el Dr. o ore ��a q Nantucket Lewis Pond ,Sound / 10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCUS MAP CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & SCALE 1 "=2000'f OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. ASSESSORS MAP 25 PARCEL 327 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE LOCUS IS WITHIN FEMA FLOOD ZONE AE PROPOSED LEACHING FACILITY. (EL. 11) AS SHOWN ON COMMUNITY PANEL 12. EXISTING LEACHING FACILITY SHALL BE PUMPED #25001 CO589J DATED 7/16/2014 AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 15. ALL TANKS ARE TO BE INSTALLED WITH WATERTIGHT SLEEVES, BOOTS AND TANKS MUST BE WATERTIGHT. 16. REFERENCE THE 25' EASEMENT RECORDED AT BARNSTABLE REGISTRY OF DEEDS CERTIFICATE #231111. VARIANCE REQUESTED UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN GROUNDWATER ADJUSTMENT: USE 1.1' OF THE JULY 2.1' ADJUSTMENT 2" PRESSURE L/AF SACK TO PUMP 0 2'0 CENTRAL FED END MAINIFOLD VENT E 22.0' 210 LATERALS AT 4' O.0 LEACHING FIELD DETAIL FLOOR PLAN (NOT TO SCALE) NOT TO SCALE TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: JAY GARDINER DATE: 7/21 /2022 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Permit .slid for REPAIR OF SEPTIC SYSTEM ONLY. itue to State and Local septic variances. Board of health review and approval is required for any fuiure additionslrenovation s/aIterations to sewagr tacduies and/or structures/dwelling. Yarmouth Health Department APPROVED 01 r, f me Date ;) L C\ DATE DANIEL A. OJALA, P.E., P.L.S. 4 ELEV. 0" 1 6.7' A \ LS 1OYR 3/2 7" /L „ 10YR 5/6 20, - 5.3 PERC C MS 2.5Y 7/4 OB GROUNDWATER ADJ. DATA: WELL: MIW-29 ZONE: A ADJUSTMENT: 2.1' (JULY 25, 2022) UNSUITABLE SOIL 1.0' 84" I 10.0' OBS. GW @ EL. 68" EL. 1.0' TITLE 5 SITE PLANOF 9 GILBERT STREET SOUTH YARMOUTH PREPARED FOR MARK HANDY DATE: SEPTEMBER 9, 2022 REV: OCTOBER 17, 2022 (EASEMENT, ABUTTER SEPTIC) Scale: 1 "= 20' OCT 2 0 2022 10 20 30 40 50 FEET HEALTH DEPT. off 508-362-4541 fax 508-362-9880 downcape.com 170WO carpe ell fkeering, idc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 22-175 AMADUCCI.DWG